CAPTEUR GAS SENSOR Search Results
CAPTEUR GAS SENSOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| 73725-0010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 73725-1010BLF | Amphenol Communications Solutions | USB 2.0, Input Output Connectors, Receptacle, Type A, Up Right, Right Angle, Through Hole, Single Deck, 4 Positions, With Sensor Contact | |||
| 72313-4010BPLF | Amphenol Communications Solutions | USB 2.0, Input Output Connector, Single Deck Receptacle, Type A, Through Hole, Right Angle, 4 Positions with Sensor Contact |
Documents mentioning CAPTEUR GAS SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ngl07 | NGL07 SPECIFICATION Carbon Monoxide Sensor for use within residential CO Detectors 2x2 mm Low Power NGL07 Heater Resistance at 21°C Typical Value 16 ± 3Ω KEY FEATURES Heater Resistance at 405 ± 15°C Typical Value 37.1 ± 7.5 Ω Baseline Sensor Resistance in |
Original | ||||
| cts03 | CT Series CTS03 - Propane / LPG Features · Fast response Long life and low cost High resistance to poisoning Low power consumption Temperature stabilisation inherent in design of Heater Driver General Interface Board also available Capteur’s ‘CT’ Series Propane / LPG sensor is |
Original | ||||
| gs22 | GS22 Sulphur Dioxide Sensor SPECIFICATION 3x3 mm Standard Power GS22 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 475 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 25 ± 5 kΩ |
Original | ||||
| toluene | AAL25 Toluene Sensor SPECIFICATION 2 x 2 mm Low Power AAS25 Heater Resistance at 21°C KEY FEATURES Typical Value 16 ± 3Ω Fast response • Heater Resistance at 380 ± 30°C Typical Value 37.1 ± 7.5Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| lgs09 | LGS09 Chlorine Sensor SPECIFICATION 3x3 mm Standard Power LGS09 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 400 ± 20°C Typical Value 13 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 2kΩ |
Original | ||||
| gs05 | GS05 Hydrogen Sulphide Sensor SPECIFICATION 3x3 mm Standard Power GS05 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 475 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| aas20 | AAS20 Iso Propyl Alcohol Sensor SPECIFICATION 3x3 mm Standard Power AAS20 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 380 ± 30°C Typical Value 12 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| lgs10 | LGS10 Nitrogen Dioxide Sensor SPECIFICATION 3x3 mm Standard Power LGS10 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 410 ± 30°C Typical Value 12 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH |
Original | ||||
| ngl07 | General information on the Capteur NGL07 Carbon Monoxide sensors Principle of Operation The Capteur ‘G’ series sensor is a Mixed Metal Oxide semiconductor based on Chromium Titanium Oxide. When heated to a high temperature the material behaves towards reducing gases as a p-type semiconductor and increases in |
Original | ||||
| gs06 | GS06 Ammonia Sensor SPECIFICATION 3x3 mm Standard Power GS06 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 410 ± 30°C Typical Value 13 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 53 ± 5 kΩ |
Original | ||||
| ozone sensor | Technical Note: TN LG.R.1.1-99 A Guide to using the Ozone Sensor with a low level Ozone generator 1. Introduction 1.1. Capteur Ozone sensors are supplied mounted on a PPS header with or without a 3mm hole in the base, and packed in trays of 100. Each sensor is |
Original | ||||
| cts23 | CTS23 Hydrogen Sensor SPECIFICATION 3x3 mm Standard Power CTS23 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 380 ± 30°C Typical Value 12 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 85 ± 5 kΩ |
Original | ||||
| aas14 | AAS14 Ethanol Sensor SPECIFICATION 3x3 mm Standard Power AAS14 Heater Resistance at 21°C KEY FEATURES Typical Value 4.67 ± 0.39Ω Heater Resistance at 385 ± 30°C Typical Value 12 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 85kΩ |
Original | ||||
| cts04 | CTS04 Butane Sensor SPECIFICATION 3x3 mm Standard Power CTS04 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 475 ± 20°C Typical Value 15 ± 2Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 25 ± 5 kΩ |
Original | ||||
|
|
||||||
| aas13 | AAS13 Methanol Sensor SPECIFICATION 3x3 mm Standard Power AAS13 Heater Resistance at 21°C KEY FEATURES Typical Value 10.6 ± 1Ω Heater Resistance at 410 ± 30°C Typical Value 14 ± 3Ω Baseline Sensor Resistance in clean air1 at 21°C 50%RH Typical Value 75 ± 5 kΩ |
Original | ||||
| v10980 | V10980 Issued / Herausgegeben / Publication / Publicatto V10980 05/2005 Flow Sensor Dual Range Zweibereichs-Durchflusssensor Instruction Leaflet Bedienungsanleitung Feuille d’instructions Foglio d’instruzioni Capteur de débit dual range Sensore di flusso a doppia portata |
Original | ||||
| 21 037-02 PSEN 1.2p-23 ATEX 4 4 4 D | 21 037-02 PSEN 1.2p-23 ATEX 4 4 4 D Betriebsanleitung GB Operating instructions F Manuel d`utilisation Sicherheitsbestimmungen Safety Regulations Conseils préliminaires • Das Gerät darf nur von Personen installiert und in Betrieb genommen werden, die mit |
Original | ||||
| psen 1.1p-23 | 21 098-03 PSEN 1.1p-23 ATEX 4 4 4 D Betriebsanleitung GB Operating instructions F Manuel d`utilisation Sicherheitsbestimmungen Safety Regulations Conseils préliminaires • Das Gerät darf nur von Personen installiert und in Betrieb genommen werden, die mit |
Original | ||||
| Protección contra sobreten- Proteção contra | Protección contra sobreten- Proteção contra sobretensão siones directamente en la diretamente na sonda de sonda de medida medição FRANÇAIS ENGLISH DEUTSCH Protection antisurtension directement sur le capteur de mesure Surge protection directly on the measuring sensor |
Original | ||||
| Operators instructions CleverLevel switch, LBFS | Operators instructions CleverLevel switch, LBFS English CleverLevel switch, type LBFS is an universal level switch, which can be used for all applications in liquids and solids with a DK-value above 1,5 English page 1…5 Deutsch Seite 6…13 Français page 14…20 |
Original | ||||
| fex300 | SM/FEX300/FEX500/ATEX/IECEX-X1 ProcessMaster / HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche gemäß Richtlinie 94/9/EG (ATEX) und IEC60079-0 (IECEx) Magnetisch-induktiver Durchflussmesser |
Original | ||||
| Short-form Operating Instruction SOI/266-XC Rev. | Short-form Operating Instruction SOI/266-XC Rev. A Short-form Instruction Manual for 266 pressure transmitters 2600T Series Pressure Transmitters Engineered solutions for all applications Language Page English…1 |
Original | ||||
| sensyflow | CI/FMT400-VTS/VTCS-X1 Sensyflow FMT400-VTS, FMT400-VTCS Inbetriebnahmeanleitung Thermischer Masse-Durchflussmesser Sensyflow FMT400-VTS, FMT400-VTCS Commissioning Instructions Thermal Mass Flowmeter Sensyflow FMT400-VTS, FMT400-VTCS Notice de mise en exploitation |
Original | ||||
| fex300 | CI/FEX300/FEX500-X1 Inbetriebnahmeanleitung Magnetisch-induktiver Durchflussmesser Commissioning Instruction Electromagnetic Flowmeter Notice de mise en exploitation Débitmètre électromagnétique Instrucciónes de Puesta en Marcha Medidor electromagnético de caudal |
Original | ||||
| GB DIMENSIONS D DIMENSIONS I All dimensions in mm | GB DIMENSIONS D DIMENSIONS I All dimensions in mm (inches) F ABMESSUNGEN Alle Abmessungen in mm (Zoll) DIMENSIONI Tutte le dimensioni sono espresse in mm (pollici) Toutes les dimensions sont en mm (pouces) 9.0 (0.35) 15.2 (0.60) 12.0 (0.47) 3.0 (0.12) 1 Ultra-Miniature, Low Power, |
Original | ||||