    PEF24628EV1X
    Rochester Electronics LLC PEF24628 - SOCRATES Four-channel SHDSL EFM system-on-chip PDF Buy
    SF-SFPP2EPASS-001
    Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-001 1m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (3.3 ft) PDF
    SF-SFPP2EPASS-000.5
    Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-000.5 0.5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (1.6 ft) PDF
    SF-SFPP2EPASS-003
    Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-003 3m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (9.8 ft) PDF
    SF-SFPP2EPASS-007
    Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-007 7m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (23 ft) PDF

    CABLE TRAY SPECIFICATION Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    s-61-402

    Abstract: S-66-524 S-95-658 T-29-520 UL 1685 S-73-532 technical information of xlpe cables 66524 icea S-95-658 29520
    Contextual Info: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.63 UL Control Cable 600V Type TC Cables — Overview Tray Cable Construction Options Belden offers a wide selection of UL-rated 600V Tray Cable for a variety of control applications. Multi-conductor versions are available as


    Original
    1-800-BELDEN-1 s-61-402 S-66-524 S-95-658 T-29-520 UL 1685 S-73-532 technical information of xlpe cables 66524 icea S-95-658 29520 PDF

    ICEA S-82-552

    Abstract: S-66-524 s-61-402 S-82-552 S-73-532 T-29-520 6 awg thhn wire for grounding 16 TFFN THHN UL1685
    Contextual Info: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.56 UL Instrumentation Cable 600V Tray Cables – Overview Tray Cable Construction Options Specifications UL Listed for MC and TC Insulation/Jacket Max. Temp Rating Wet Dry PVC-Nylon/PVC THHN or THWN 14 AWG & larger


    Original
    S-73-532 S-61-402 1-800-BELDEN-1. ICEA S-82-552 S-66-524 s-61-402 S-82-552 S-73-532 T-29-520 6 awg thhn wire for grounding 16 TFFN THHN UL1685 PDF

    Contextual Info: FIBER OPTIC PRODUCTS Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-69 Adapter Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 Fiber Splice Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 Fiber Optic Cable Assemblies . . . . . . . . . . . . . . . .71-72


    Original
    PDF

    Contextual Info: Industrial Fiber Optic Cables, LSZH Tray-Rated, Single-Jacket Cable, 12-288 Fibers Features and Benefits Low-smoke, zero-halogen sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated per UL 13; UL 444; UL 1277; UL 1666; CSA


    Original
    PDF

    Contextual Info: Mining and Petrochemical Tray-Rated, Loose Tube, Gel-Free Cable 60 F, 50 µm multimode OM3 229.5012 Corning dielectric, low-temperature, tray-rated, mining and petrochemical fiber optic cables are designed for indoor and outdoor use in mining and petrochemical backbones (aerial and duct) and horizontal intrabuilding and


    Original
    060TUL-T3680D2M 060TUL-T3680D2M PDF

    Contextual Info: Mining and Petrochemical Tray-Rated, Loose Tube, Gel-Free Cable 288 F, 50 µm multimode OM3 229.5012 Corning dielectric, low-temperature, tray-rated, mining and petrochemical fiber optic cables are designed for indoor and outdoor use in mining and petrochemical backbones (aerial and duct) and horizontal intrabuilding and


    Original
    288TUL-T3680D2M 288TUL-T3680D2M PDF

    Contextual Info: Mining and Petrochemical Tray-Rated, Loose Tube, Gel-Free Cable 192 F, 50 µm multimode OM3 235.51 Corning dielectric, low-temperature, tray-rated, mining and petrochemical fiber optic cables are designed for indoor and outdoor use in mining and petrochemical backbones (aerial and duct) and horizontal intrabuilding and


    Original
    192TUL-T3680D2M 192TUL-T3680D2M PDF

    Contextual Info: Mining and Petrochemical Tray-Rated, Loose Tube, Gel-Free Cable 48 F, 50 µm multimode, extended 10G distance OM4 229.5012 Corning dielectric, low-temperature, tray-rated, mining and petrochemical fiber optic cables are designed for indoor and outdoor use in mining and petrochemical backbones (aerial and duct) and horizontal intrabuilding and


    Original
    048TUL-T3691D2M 048TUL-T3691D2M PDF

    s-61-402

    Abstract: 2012 NEC
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1066A Multi-Conductor - 600V Tray Cable For more Information please call 1-800-Belden1 Description: 18 AWG pairs stranded 7x26 bare copper conductors, twisted pairs, PVC/Nylon insulation, overall


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. 66-1066A-5000-10 s-61-402 2012 NEC PDF

    s-61-402

    Abstract: at 9341
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9341 Multi-Conductor - 600V Tray Cable For more Information please call 1-800-Belden1 Description: 18 AWG pairs stranded 19x30 tinned copper conductors, twisted pairs, PVC/Nylon insulation, overall


    Original
    1-800-Belden1 19x30) 19x30 73/23/EEC) 93/68/EEC. s-61-402 at 9341 PDF

    s-61-402

    Abstract: chloride ups
    Contextual Info: Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9343 Multi-Conductor - 600V Tray Cable For more Information please call 1-800-Belden1 Description: 14 AWG pairs stranded 42x30 tinned copper conductors, twisted pairs, PVC/Nylon insulation, overall


    Original
    1-800-Belden1 42x30) 42x30 73/23/EEC) 93/68/EEC. s-61-402 chloride ups PDF

    Contextual Info: SPEC 9400 July, 2014 CCW Armored Instrumentation, Pairs/Triads, Individual and Overall Shield UL Type MC-HL, 600 V or UL Type ITC-HL, 300 V, XLPE, 90°C, Cable Tray Use Sunlight-Resistant, Direct Burial, UL Marine Shipboard Cable, ABS CWCMC, Arctic-Grade


    Original
    PDF

    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9330 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 22 AWG pairs stranded 7x30 tinned copper conductors, twisted pairs, PVC insulation, individually


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. PDF

    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9369 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 18 AWG pairs stranded 19x30 tinned copper conductors, twisted pairs, PVC insulation, individually


    Original
    1-800-Belden1 19x30) 19x30 73/23/EEC) 93/68/EEC. PDF

    UPS chloride

    Abstract: chloride ups awm 2464 300v cable specification Belden AWM 2464 80c 300v UL-1685
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9363 Triad - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 22 AWG triads stranded 7x30 tinned copper conductors, twisted triads, PVC insulation, overall Beldfoil


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. UPS chloride chloride ups awm 2464 300v cable specification Belden AWM 2464 80c 300v UL-1685 PDF

    Belden AWM 2464 80c 300v

    Abstract: Belden AWM 2464 16 AWG 1030A awm 2464 300v cable specification
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1030A Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 16 AWG pairs stranded 7x24 bare copper conductors, twisted pairs, overall Beldfoil shield (100%


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. Belden AWM 2464 80c 300v Belden AWM 2464 16 AWG 1030A awm 2464 300v cable specification PDF

    1030a

    Abstract: ul 2464 CSA AWM 01010000 awm 2464 300v cable specification
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1030A Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 16 AWG pairs stranded 7x24 bare copper conductors, twisted pairs, overall Beldfoil shield (100%


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. 1030a ul 2464 CSA AWM 01010000 awm 2464 300v cable specification PDF

    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1033A Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 20 AWG pairs stranded 7x28 bare copper conductors, twisted pairs, PVC insulation, overall Beldfoil


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. 66-1033A-1000-10 PDF

    belden 2464

    Abstract: Belden AWM 2464 16 AWG 9366
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9366 Triad - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 16 AWG triads stranded 19x29 tinned copper conductors, twisted triads, overall Beldfoil shield (100%


    Original
    1-800-Belden1 19x29) 19x29 73/23/EEC) 93/68/EEC. belden 2464 Belden AWM 2464 16 AWG 9366 PDF

    9409

    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9409 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 18 AWG pairs stranded 19x30 tinned copper conductors, twisted pairs, PVC insulation, unshielded, PVC


    Original
    1-800-Belden1 19x30) 19x30 73/23/EEC) 93/68/EEC. 9409 PDF

    CL3R

    Abstract: UL-1685
    Contextual Info: Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 9412 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 12 AWG pairs stranded 65x30 tinned copper conductors, twisted pairs, PVC insulation, unshielded, PVC


    Original
    1-800-Belden1 65x30) 65x30 73/23/EEC) 93/68/EEC. CL3R UL-1685 PDF

    T-29-520

    Abstract: 1-800-BELDEN-1
    Contextual Info: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.41 UL Instrumentation Cable 300V Power-Limited Tray Cables — Overview Construction Application Specifications Soft annealed bare or tinned copper with PVC flame retardant insulation and jacket. Other insulation and jacket options are


    Original
    PDF

    Belden AWM 2464 80c 300v

    Abstract: nec 9552 awm 2464 300v cable specification
    Contextual Info: Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9552 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 18 AWG pairs stranded 19x30 tinned copper conductors, twisted pairs, PVC insulation, overall Beldfoil


    Original
    1-800-Belden1 19x30) 19x30 73/23/EEC) 93/68/EEC. Belden AWM 2464 80c 300v nec 9552 awm 2464 300v cable specification PDF

    Contextual Info: Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 9526 Multi-Conductor - 300V Power-Limited Tray Cable For more Information please call 1-800-Belden1 Description: 22 AWG pairs stranded 7x30 tinned copper conductors, twisted pairs, PVC insulation, overall Beldfoil


    Original
    1-800-Belden1 73/23/EEC) 93/68/EEC. PDF