    Bussmann ® Circuit Protection Solutions Bussmann
    Bussmann ® Circuit Protection Solutions Bussmann ® Worldwide Circuit Protection Solutions World’s leading supplier of fuses and fusible protection systems, Bussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry’s first
    Original PDF
    Cooper Bussmann® Services & Application Guide
    Cooper Bussmann® Services & Application Guide Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Cooper Bussmann Services Engineering…370
    Original PDF
    Bussmann electrical full line catalog Leadership
    Bussmann electrical full line catalog Leadership in Circuit Protection Introducing Bussmann by Eaton The protection you rely on. For more, visit Bussmann.com Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications.
    Original PDF
    zilox
    Bussmann INDICATOR SYSTEM Typower Zilox fuses are available with three different indicator systems. Visual Indicator The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for operating the indicator is 20V.
    Original PDF
    zilox
    Bussmann ® Square Body – Accessories Fuse Bases (Blocks) DIN 43 653 Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, the following fuse bases are available: Part Number 170H3003 170H3004 170H3005 170H3006 Max. Voltage 1000V 1000V 1400V 1400V
    Original PDF
    zilox
    Bussmann ® Square Body – Accessories Indicator System ® Indicators Typower ZILOX fuses are available with three different indicator systems. Visual Indicator The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for
    Original PDF
    Bussmann® Square Body - Flush End Contact 1000V
    Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 3 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 315–1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 315 350
    Original PDF
    Bussmann® Square Body - Flush End Contact 1000V
    Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160–630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 160 200 250 315 350 400 450
    Original PDF
    Bussmann® Square Body – DIN 43 653 1000V
    Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 3 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 900 315-1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 315 350
    Original PDF
    Bussmann® Square Body – DIN 43 653 1000V
    Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160-630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 160 200 250 315 350 400
    Original PDF
    Bussmann® Square Body - US-Style 1000V (IEC) Size
    Bussmann® Square Body - US-Style 1000V (IEC) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-1400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 250 315 350 400 450 500 550 630 700
    Original PDF
    Bussmann® Square Body - Flush End Contact 1000V
    Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 250–800A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 250 315 350 400 450 500 550
    Original PDF
    Bussmann® Square Body - Flush End Contact 1000V
    Bussmann® Square Body - Flush End Contact 1000V (IEC) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50–400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 50 63 80 100 125 160
    Original PDF
    Bussmann® Square Body - US-Style 1000V (IEC) Size
    Bussmann® Square Body - US-Style 1000V (IEC) Size 1 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 160-630A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 160 200 250 315 350 400 450 500 550
    Original PDF
    Bussmann® Square Body - US-Style 1000V (IEC) Size
    Bussmann® Square Body - US-Style 1000V (IEC) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated Pre-arc RMS-Amps Voltage 50 63 80 100 125 160 200 250 315
    Original PDF
    Bussmann® Square Body – DIN 43 653 1000V
    Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 2 Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 250-800A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 250 315 350 400 450 500
    Original PDF
    Bussmann® Square Body – DIN 43 653 1000V
    Bussmann® Square Body – DIN 43 653 1000V (IEC/U.L.) Size 1* Rated Voltage 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 50-400A Electrical Characteristics I2t (A2s) Rated Clearing Current at Rated RMS-Amps Pre-arc Voltage 50 63 80 100 125 160 200
    Original PDF
    Bussmann® High Speed Fuses North American Style —
    Bussmann® High Speed Fuses North American Style — General Information Voltage Rating 130V AC/DC 1000 to 4000 Amperes 150V AC/DC 70 to 1000 Amperes 250V AC/DC 35 to 2500 Amperes 500V AC/DC 35 to 1600 Amperes 600V AC 1 to 1000 Amperes 700V AC/DC 5 to 1200 Amperes
    Original PDF
    mikroschalter
    Sicherungshalter und Sicherungssysteme Sicherungshalter und Kennmelder für Halbleiterschutzsicherungen Mikroschalter und Adaptertyp MAI Ausgelöstmelder Bemessungsstrom: AC 50/60 Hz ohmsche Belastung @ 250 VRMS AC 50/60 Hz ohmsche Belastung @ 127 VRMS 4A
    Original PDF
    Circuit Protection Products for the Electrical
    Circuit Protection Products for the Electrical Industry New Products for All Markets For product data sheets, visit www.cooper.bussmann.com/products/datasheet.asp Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information
    Original PDF
    Circuit Protection Products for the Electrical
    Circuit Protection Products for the Electrical Industry New Products for All Markets For product data sheets, visit www.cooper.bussmann.com/products/datasheet.asp Circuit Protection Products for the Electrical Industry Table of Contents RED indicates NEW information
    Original PDF
    High Speed Fuses Square Body Fuses General
    High Speed Fuses Square Body Fuses General Information Introduction Square Body Contents Page Application Information 115-116 Volts (IEC/UL) Size 000,00 690/700 1*, 1, 2, 3 1*, 2, 3 4 23, 24 00, 1, 2, 3 00 1000 1*, 1, 2, 3 4 24 1*, 1, 2, 3 1250/1300 1000-2000
    Original PDF
    10129 LIST OF COMPANY IDENTIFICATIONS The List of
    10129 LIST OF COMPANY IDENTIFICATIONS The List of Company Identifications contains the trade names, trademarks, or other designations authorized for use in lieu of these Company names. ‘‘ ’’ — 2CS SRL ’’ — ACT CO LTD ‘‘‘ ’’ — 3E (HK) LTD