BUSBAR CALCULATION FR Search Results
BUSBAR CALCULATION FR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| 69144-210LF | Amphenol Communications Solutions | Low Profile Jumper , Single Row, Multi Position Busbar , 10 Positions, 2.54mm (0.100in) Pitch | |||
| 69145-112LF | Amphenol Communications Solutions | Low Profile Jumper , Double Row, Multi Position Busbar , 12 Positions, 2.54mm (0.100in) Pitch | |||
| 69145-210LF | Amphenol Communications Solutions | Low Profile Jumper , Double Row, Multi Position Busbar , 10 Positions, 2.54mm (0.100in) Pitch | |||
| 69145-314LF | Amphenol Communications Solutions | Low Profile Jumper , Double Row, Multi Position Busbar , 14 Positions, 2.54mm (0.100in) Pitch | |||
| 69144-208LF | Amphenol Communications Solutions | Low Profile Jumper , Single Row, Multi Position Busbar , 8 Positions, 2.54mm (0.100in) Pitch |
Documents mentioning BUSBAR CALCULATION FR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| Thermal Properties of Power Terminals in High | Thermal Properties of Power Terminals in High Power IGBT Modules A. Cosaert1, M. Beulque1, M. Wölz2, O. Schilling2, H. Sandmann2, R. Spanke2, K. Appelhoff2 1 2 Rogers NV, Gent, Belgium eupec GmbH, Warstein, Germany Abstract Power dissipation in the leads of IGBT modules has to be taken into account for modern inverter design. This is |
Original | ||||
| REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December | REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December 1997 Changed since October 1997 Data subject to change without nolice Contra I terminal ABB Network Partner Features .Controi functions in a numerical unit sl3parated from the object protection units .Is an advantage to use in the followin~1 applications: |
Original | ||||
| European PowerSemiconductor and Electronics | European PowerSemiconductor and Electronics Company GmbH + Co. KG Design Aspects for Inverters with IGBT High Power Modules Dr.-Ing. Th. Schütze, eupec GmbH & Co KG, Warstein, Germany Abstract With regard to the blocking ability and efficiency of the new 3.3 kV IGBT high voltage modules (IHV) with nominal |
Original | ||||
| Properties of a New PrimePACK™ IGBT Module | Properties of a New PrimePACK™ IGBT Module Concept for Optimized Electrical and Thermal Interconnection to a Modern Converter Environment O. Schilling, M. Wölz, G. Borghoff, Th. Nübel, G. Bräker, Chr. Lübke, eupec GmbH , Warstein Abstract: II PrimePACK™ module line-up |
Original | ||||
| PowerDesign v1.0 GE Consumer & Industrial Power | PowerDesign v1.0 GE Consumer & Industrial Power Protection Design and Quotation software New features - Copy/Paste enclosures or functions - Display selected devices in Device explorer, add/remove devices from this section - Manage the enclosures in subproject groups |
Original | ||||
| ahr-b420 | AC/DC Current transducer AHR-B420 IPN = 500 .. 2000 A The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True r.m.s. 4-20 mA current output. |
Original | ||||
| ahr-b10 | IPN = 500 .. 2000 A AC/DC Current transducer AHR-B10 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-10 V voltage output. |
Original | ||||
| AC/DC Current transducer AHR-B5 IPN = 500 .. 2000 | AC/DC Current transducer AHR-B5 IPN = 500 .. 2000 A The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-5 V voltage output. |
Original | ||||
| GE Consumer & Industrial Power Protection New | GE Consumer & Industrial Power Protection New QuiXtra™630 Low Voltage distribution boards up to 630A GE imagination at work QuiXtra™630 Introduction A.2 Advantages A.4 Applications A.5 Product description A.7 Features and benefits A.8 Kit structure A.10 |
Original | ||||
| current transducer | AC/DC Current transducer AHR-B420 IPN = 500 .. 2000 A The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 4-20 mA current output. |
Original | ||||
| GE Energy Industrial Solutions New ™ QuiXtra 630 | GE Energy Industrial Solutions New ™ QuiXtra 630 Low Voltage distribution boards up to 630A GE imagination at work QuiXtra™630 Introduction A.2 Advantages A.4 Applications A.5 Product description A.7 Features and benefits A.8 Kit structure A.10 Main technical characteristics |
Original | ||||
| ahr-b10 | IPN = 500 .. 2000 A AC/DC Current transducer AHR-B10 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-10 V voltage output. |
Original | ||||
| REB 103 and REB 101 1wirk 505 002-BEN Busbar | REB 103 and REB 101 1wirk 505 002-BEN Busbar protection Page 1 November 1995 Changed since March 1992 Replaces 1MDB05006-EN Data subject to change without notice ABB Network Partner (SE 90 00 20) Features • Based upon a previous design with long experience |
OCR Scan | ||||
| T y p e R E B 1MDB05006—EN 100 Page 1 March 1992 | T y p e R E B 1MDB05006—EN 100 Page 1 March 1992 Data subject to change without notice • New Busbar protection ASF A BROWN «OVER» ABB Network Control & Protection —,---- r— Features Application • Based upon a previous design with long experience |
OCR Scan | ||||
|
|
||||||
| 899.05.26 | INVERTRON DBU Dynamic Braking Unit Instruction Manual C Manual P/N. UL R 899.05.26 User Manual: 49‘1328e (06) Publication INVDBU-UM006F-EN-P . TABLE OF CONTENTS 1. DESCRIPTION 1-1…1-2 Operation… 1-1 |
Original | ||||
| dhr-c420 | IPN = 100..1000 A AC/DC Current transducer DHR-C420 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 4-20mA current output. |
Original | ||||
| AC/DC Current transducer DHR-C5 IPN = 100..1000 A | AC/DC Current transducer DHR-C5 IPN = 100..1000 A The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-5V voltage output. |
Original | ||||
| dhr-c10 | IPN = 100..1000 A AC/DC Current transducer DHR-C10 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 0-10V voltage output. |
Original | ||||
| reb 670 | Busbar differential protection IED REB 670 Buyer's Guide Pre-configured 1MRK 505 172-BEN Revision: A Issued: February 2007 Data subject to change without notice Page 1 Features • IED for differential protection of busbars, meshed corners and T-protection |
Original | ||||
| KkfH % 4 Type RES 010 Synchronizing relay im d | KkfH % 4 Type RES 010 Synchronizing relay im d bio o o s - e n Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (SE 90623) Features Application RES 010 is a microprocessor based relay performing synchronizing, paralleling and |
OCR Scan | ||||
| an4999 | AN4999 Application Note AN4999 Turn-On Performance Of Thyristors In Parallel Application Note Replaces September 2000 version, AN4999-4.0 AN4999-4.1 July 2002 The selection of thyristors for connection in parallel in high power circuits follows many of the same rules as used for rectifier |
Original | ||||