    1SS352
    Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.1 A, USC, AEC-Q101 Datasheet
    1SS307E
    Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.1 A, ESC, AEC-Q101 Datasheet
    1SS302A
    Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.1 A, USM, AEC-Q101 Datasheet
    1SS361FV
    Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.1 A, VESM, AEC-Q101 Datasheet
    TB6551FAG
    Toshiba Electronic Devices & Storage Corporation Brushless Motor Driver/3 Phases Controller/Vout(V)=12/Sine Wave Datasheet

    Documents mentioning BREAKER CONTROL SWITCH

    Document Partial File Text Tags Type PDF
    breaker
    Remote Control Circuit Breaker 4930 (RCCB) Description Single pole remote control circuit breaker (RCCB), temperature compensated, either with or without auxiliary contacts, and featuring a bimetal actuator which trips the circuit breaker mechanism within
    Original PDF
    240-241.qxp 7/22/2010 3:06 PM Page 241 Fiberglass
    240-241.qxp 7/22/2010 3:06 PM Page 241 Fiberglass Enclosures Disconnect and Circuit Breaker Series Breaker Series The Cooper Crouse-Hinds Disconnect and Circuit Breaker Series are used in larger industrial control systems and machine tool control panels where a disconnect is desirable in extreme environmental
    Original PDF
    crouse-hinds
    Fiberglass Enclosures Disconnect and Circuit Breaker Series 5E The Cooper Crouse-Hinds Disconnect and Circuit Breaker Series are used in larger industrial control systems and machine tool control panels where a disconnect is desirable in extreme environmental
    Original PDF
    terminal block
    Circuit Protection & Control Plug-in circuit breaker type 1180 with terminal block. For trouble-free system protection. Technical Information. Circuit Breaker Type 1180 for plug in terminal block mounting. The E-T-A thermal circuit breaker type 1180 reduces stoppages and downtime.
    Original PDF
    DN-30 UNITRODE Design Note PROGRAMMABLE
    DN-30 UNITRODE Design Note PROGRAMMABLE ELECTRONIC CIRCUIT BREAKER The design of a programmable electronic circuit breaker is shown below which utilizes the UC3843A control 1C to facilitate a high speed turn-off following an overcurrent condition. This low cost, industry standard 1C contains
    OCR Scan PDF
    Control terminal REC 561*2.0 1MRK 606 009-BEN
    Control terminal REC 561*2.0 1MRK 606 009-BEN Page 1 Issued May 2002 Changed since October 1999 Data subject to change without notice (SE 95 02 22) Features • Control functionality for; - single, double and triple busbar arrangements - double breaker arrangements
    Original PDF
    %UHDNHU SURWHFWLRQ WHUPLQDO ZLWK DXWRPDWLF
    %UHDNHU SURWHFWLRQ WHUPLQDO ZLWK DXWRPDWLF UHFORVLQJ DQG V\QFKURFKHFN )HDWXUHV • Current - Breaker failure protection (BFP) • Secondary system supervision - Fuse failure supervision (FUSE) • Control - Synchrocheck (SYN) - Automatic reclosing function (AR)
    Original PDF
    axc-102
    AXC-102 ACTIVE FILTER FOR RIPPLE ATTENUATION 20A PRELIMINARY Features : ? ? ? ? ? ? ? ? ? High Efficiency. Superior Performance at Low Frequencies. Output Impedance Less Than 5mΩ. Retriggerable / Non-retriggerable Circuit Breaker. Shut Down. Sense Input Control.
    Original PDF
    V-EA and MA Circuit Breaker Accessories
    V-EA and MA Circuit Breaker Accessories Accessories can be factory or field mounted on V-EA miniature circuit breakers and MA motor protection switches for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories
    Original PDF
    y UCC1913 UCC2913 UCC3913 INTEGRATED CIRCUITS U N
    y UCC1913 UCC2913 UCC3913 INTEGRATED CIRCUITS U N IT R O D E Negative Voltage Circuit Breaker FEATURES Precision Fault Threshold Programmable Average Power Limiting Programmable Linear Current Control Programmable Overcurrent Limit Programmable Fault Time
    OCR Scan PDF
    E209569 up to 12 Amps UL1077 Recognized
    E209569 up to 12 Amps UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to overload conditions. Current Rating 0.5 -16.0A Rated Voltage
    Original PDF
    td230
    TD230  ELECTRONIC CIRCUIT BREAKER… TWO N-CHANNEL MOSFETs CONTROL AND DUAL INDEPENDANT CURRENT SUPERVISION FOR OVER CURRENT PROTECTION DUAL SUPPLY OPERATION FROM +3/-5 TO +18/-18V OPERATING VOLTAGE STEP-UPCONVERTER : VCC +13.5V OUTPUT VOLTAGE
    Original PDF
    td230
    TD230  ELECTRONIC CIRCUIT BREAKER… TWO N-CHANNEL MOSFETs CONTROL AND DUAL INDEPENDANT CURRENT SUPERVISION FOR OVER CURRENT PROTECTION DUAL SUPPLY OPERATION FROM +3/-5 TO +18/-18V OPERATING VOLTAGE STEP-UPCONVERTER : VCC +13.5V OUTPUT VOLTAGE
    Original PDF
    Type RANCI m fm . Æ f -3 1MDB11006-EN Page 1
    Type RANCI m fm . Æ f -3 1MDB11006-EN Page 1 March 1992 Dual frequency signal tranceiver Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (880137) Features Application • Remote breaker tripping, remote signalling
    OCR Scan PDF
    td230
    TD230 ELECTRONIC CIRCUIT BREAKER ■ TWO N-CHANNEL MOSFETs CONTROL ■ AND DUAL INDEPENDENT CURRENT SUPERVISION FOR OVER CURRENT PROTECTION DUAL SUPPLY OPERATION FROM +3/-5V OPERATING VOLTAGE STEP-UP CONVERTER : VCC +13.5V OUTPUT VOLTAGE
    Original PDF
    rec 670
    Bay control IED REC 670 Buyer's Guide Pre-configured 1MRK 511 176-BEN Revision: H Issued: February 2007 Data subject to change without notice Page 1 Features • Three configuration alternatives for single- or multi-breaker arrangements available – ready to
    Original PDF
    td230
    TD230 ELECTRONIC CIRCUIT BREAKER ■ TWO N-CHANNEL MOSFETs CONTROL ■ AND DUAL INDEPENDENT CURRENT SUPERVISION FOR OVER CURRENT PROTECTION DUAL SUPPLY OPERATION FROM +3/-5V OPERATING VOLTAGE STEP-UP CONVERTER : VCC +13.5V OUTPUT VOLTAGE
    Original PDF
    breaker failure relay
    I Type REB 010 Breaker failure relay 1M DB05007-EN Pag© 1 September 1992 Changed since March 1992 Data subject to change without notice ASEA BROWN BOVERI, ABB Network Control & Protection T Features Application •Local redundant protection when the circuit
    OCR Scan PDF
    June 17, 2002 TECH BRIEF RE-DESIGNED 808 magnetic
    June 17, 2002 TECH BRIEF RE-DESIGNED 808 magnetic circuit breaker Attractive modern styled housing The 808 is designed to be instantly recognized as a product of E-T-A. IDEALLY SUITED FOR: • Telecommunications systems • Process control • Semiconductor protection
    Original PDF
    NIS5101 Advance Information SMART HotPlugt
    NIS5101 Advance Information SMART HotPlugt IC/Inrush Limiter/Circuit Breaker The SMART HotPlug Integrated Circuit combines the control function and power FET into a single IC that saves design time and reduces the number of components required for a complete hot swap
    Original PDF
    1264-2012.qxp:QuarkCatalogTempNew 9/4/12 7:00 AM
    1264-2012.qxp:QuarkCatalogTempNew 9/4/12 7:00 AM Page 1264 POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 14 Fuse Holders Applications. Marathon Fuse Holders can be used in various applications, including control panels, lighting and heating circuits, motor circuits, circuit breaker protection, switchgear equipment, appliances, electric heat, air conditioning and refrigeration
    Original PDF
    r r w m TECHNOLOGY LTC1421 Hot Swap Controller
    r r w m TECHNOLOGY LTC1421 Hot Swap Controller f€flTUR€S DCSCRIPTIOfl ■ Allows Safe Board Insertion and Removal from a Live Backplane ■ System Reset and Power Good Control Outputs ■ Programmable Electronic Circuit Breaker ■ User Programmable Supply Voltage Power-Up Rate
    OCR Scan PDF