BOLT ON BREAKERS Search Results
BOLT ON BREAKERS Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| AV-THLIN2BNCM-005 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft | |||
| CN-DSUB25PIN0-000 | Amphenol Cables on Demand | Amphenol CN-DSUB25PIN0-000 D-Subminiature (DB25 Male D-Sub) Connector, 25-Position Pin Contacts, Solder-Cup Terminals | |||
| CN-DSUBHD26PN-000 | Amphenol Cables on Demand | Amphenol CN-DSUBHD26PN-000 High-Density D-Subminiature (HD26 Male D-Sub) Connector, 26-Position Pin Contacts, Solder-Cup Terminals | |||
| CO-058BNCRBNC-010 | Amphenol Cables on Demand | Amphenol CO-058BNCRBNC-010 BNC Male to BNC Right Angle Male (RG58) 50 Ohm Coaxial Cable Assembly 10ft | |||
| CO-058BNCX200-012 | Amphenol Cables on Demand | Amphenol CO-058BNCX200-012 BNC Male to BNC Male (RG58) 50 Ohm Coaxial Cable Assembly 12ft |
Documents mentioning BOLT ON BREAKERS
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| quicklag | 11-6 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0438] QUICKLAG — Bolt-On Ground Fault and Equipment Protectors Bolt-On Types BAB, QBHW, HBAX, HBAW Product Selection Table 11-6. Breaker Catalog Numbers Continuous Ampere Rating @ 40°C 1-Pole |
Original | ||||
| Molded Case Circuit Breakers List of products | Molded Case Circuit Breakers List of products G-TWIN Standard Series (IEC/EN/GB/JIS conformed) Line protection Motor protection AC415V BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 AC415V BW32 BW50 BW63 BW100 BW125 BW250 Icu Icu 1.5kA AAG AAG 2.5kA |
Original | ||||
| nzm7 | 10/001 Moeller HPL0211-2001/2002 NZM7 40 to 250 A NZM10 250 to 630 A Circuit-Breakers, Switch-Disconnectors up to 1600 A NZM Circuit-Breakers, NZM, P Switch-Disconnectors Overview NZM14 800 to 1600 A Technical overview Page 10/002 Technical overview Page 10/002 |
Original | ||||
| current transformer | Pr o du ct 42 Bushing Current Transformer Low Voltage Instrument Transformer Multi-Ratio, Externally Mounted 25 through 60 Hertz Application Externally mounted bushing current transformers are designed for use on existing power transformers or circuit breakers for |
Original | ||||
| quicklag | 11- Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0445] QUICKLAG — Cable-In/Cable-Out Ground Fault and Equipment Protectors Cable-In/Cable-Out Ground Fault and Equipment Protectors, Types QCGF, QCHGF, QCGFEP, QCHGFEP Wiring Diagram Blue Ground |
Original | ||||
| quicklag | 11-4 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0436] QUICKLAG — Plug-On Types QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW Product Selection Table 11-2. Breaker Catalog Numbers Continuous Ampere Rating @ 40°C 1-Pole 120/240V AC Catalog |
Original | ||||
| DILL BLOX MODULAR POWER DISTRIBUTION SYSTEMS | DILL BLOX MODULAR POWER DISTRIBUTION SYSTEMS PROVIDING SOLUTIONS FOR: POWER DISTRIBUTION DESIGNED FOR: FUSES CIRCUIT PROTECTION TERMINAL PROTECTION CIRCUIT BREAKERS RELAYS FLASHERS LIGHTS POWER TAPS DIODES CUSTOM COMPONENTS… Fargo Assembly of PA., Inc. 800 West Washington St. P.O. Box 550 |
Original | ||||
| Type: NZMN2−M125 Article No.: 265723 Sales text | Type: NZMN2−M125 Article No.: 265723 Sales text Circuit−breaker 3p 125A motor protection Ordering information Number of poles 3−pole Description Terminal screws standard, terminals as accessories Rated current = rated uninterrupted current Iu A 125 Ir |
Original | ||||
| nzmb1 | Type: NZMB1−A40 Article No.: 259075 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 40 Ir A 32…40 |
Original | ||||
| nzmb1 | Type: NZMB1−A100 Article No.: 259079 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 100 Ir A |
Original | ||||
| nzmb1 | Type: NZMB1−A63 Article No.: 259077 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 63 Ir A 50…63 |
Original | ||||
| nzmb1 | Type: NZMB1−A50 Article No.: 259076 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 50 Ir A 40…50 |
Original | ||||
| nzmb1 | Type: NZMB1−A80 Article No.: 259078 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 80 Ir A 63…80 |
Original | ||||
| $22.00 BURNDY PRODUCTS www.fciconnect.com CALL | $22.00 BURNDY PRODUCTS www.fciconnect.com CALL 1-800-346-4175 FOR YOUR LOCAL SALES REPRESENTATIVE Connector Theory and Application Experience. Technology. Answers. Customer Service Dept. 7 Aviation Park Drive Londonderry, NH 03053 1-800-346-4175 Quebec & Eastern Ontario |
Original | ||||
|
|
||||||
| a125 | Type: NZMB1−A125 Article No.: 259080 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 125 Ir A |
Original | ||||
| a125 | Type: NZMN1−A125 Article No.: 259086 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 125 Ir A |
Original | ||||
| nzmn | Type: NZMN1−A50 Article No.: 259082 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 50 Ir A 40…50 |
Original | ||||
| Type: NZMN1−A80 Article No.: 259084 Sales text | Type: NZMN1−A80 Article No.: 259084 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 80 Ir A 63…80 |
Original | ||||
| Type: NZMN1−A100 Article No.: 259085 Sales text | Type: NZMN1−A100 Article No.: 259085 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 100 Ir A |
Original | ||||
| Type: NZMN1−A40 Article No.: 259081 Sales text | Type: NZMN1−A40 Article No.: 259081 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 40 Ir A 32…40 |
Original | ||||
| Type: NZMN1−A63 Article No.: 259083 Sales text | Type: NZMN1−A63 Article No.: 259083 Sales text Circuit−breaker3p systems/cable prot. Ordering information Number of poles 3−pole Description Terminals standard, terminal screws as accessories Rated current = rated uninterrupted current Iu A 63 Ir A 50…63 |
Original | ||||
| 194R IEC Fused and Non-Fused Rotary Disconnect | 194R IEC Fused and Non-Fused Rotary Disconnect Switches 194R IEC Fused and Non-Fused Rotary Disconnect Switches Versatility The Bulletin 194R Disconnect switches offer unparalleled versatility. The switches offer a variety of fused and non-fused versions from 20A- up to 800A. All 194R’s possess the most-often |
Original | ||||
| 140u | TECHNICAL DATA BULLETIN 140U/UE Molded Case Circuit Breakers CATALOG NUMBERS 140U/UE Bulletin 140U/UE Molded Case Circuit Breakers Electrical Specifications • Standards 4 • Interrupting Ratings 4 • Rated Insulation Voltage 4 • Rated Impulse Withstand Voltage |
Original | ||||