Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BLOWN FUSE INDICATOR Search Results

    BLOWN FUSE INDICATOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCK305G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK321G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet
    TCK304G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK301G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK323G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet

    BLOWN FUSE INDICATOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    e05a marking

    Abstract: 1616460000 e05a E-05A
    Contextual Info: ZSI 2.5/2 Circuit Protection Terminals with blown fuse indicator for AC or DC voltage Warning: •Install ZAP TNHE fuse cover plate after last ZSI 2.5/2. •Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indica­


    OCR Scan
    30-70VDC/AC 13/32x e05a marking 1616460000 e05a E-05A PDF

    Fuse T 2.5

    Contextual Info: Circuit Protection Terminals KDKS 1/PE with blown fuse indicator BFI and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which


    OCR Scan
    PDF

    TAM fuse

    Abstract: l4 tam
    Contextual Info: WSI 6/2 Circuit Protection Terminals with blown fuse indicator Warning: for AC or DC voltage. • Install WAP partition after last WSI 6/2. • Disconnect power before replacing the fuse. Fuse terminals are available with I LED blown fuse indicators, which


    OCR Scan
    PDF

    c 33740

    Abstract: 110VDC LED Driver 16164-2 161644 220vac LED driver T 10A H 250V fuse 33740 blown fuse C 337-40
    Contextual Info: Tension Clamp 35 mm DIN-Rail Terminals Circuit Protection Fuse, Single Level ZSI 2.5 For Circuit Breakers, see with blown fuse indicator with 2 blown fuse Indicators for AC or DC voltage for DC voltage page 2/20-26 Warning: • Install ZAP TNHE fuse cover


    OCR Scan
    PDF

    Fuse 0430900000

    Abstract: thermal fuse vdc 0474560000
    Contextual Info: Circuit Protection Terminals ASK 1 combi-foot with blown fuse indicator BFI Warning: and circuit disconnect • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which


    OCR Scan
    PDF

    2SD28

    Contextual Info: Circuit Protection Terminals WSI 6 with blown fuse indicator Warning: for AC or DC voltage • Install WAP partition after last WSI 6. • Disconnect power before replacing the fuse. ï Fuse terminals are available with it i n *“ 1,1 ï • r I' LED blown fuse indicators, which


    OCR Scan
    PDF

    ATQ Fuses

    Abstract: blown fuse indicator FLQ 6 fuse KLK Fuses A25Z-2 LR21455 A60Q
    Contextual Info: Product Data Sheet 6SM30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Midget Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. 2.0 N•m


    Original
    6SM30AXI A13X-2, A25Z-2, A60Q-2, E35113 M1987, LR21455 MN35-2 ATQ Fuses blown fuse indicator FLQ 6 fuse KLK Fuses A25Z-2 LR21455 A60Q PDF

    blown fuse indicator

    Abstract: ATQR Fuses can we replace ac fuse with dc fuse LR21455
    Contextual Info: Product Data Sheet 6SC30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Class CC Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. 2.0 N•m


    Original
    6SC30AXI E35113 M1987, LR21455 MN35-2 blown fuse indicator ATQR Fuses can we replace ac fuse with dc fuse LR21455 PDF

    BJS131

    Abstract: FU520 PR30 FEM13U 14-26AWG T01088 26201
    Contextual Info: T01088 020128 MU 10/13.SF1 Fuse holder terminal blocks for 5 x 20 mm and 5 x 25 mm fuses Compression clamp MU 10/14,5.SF1 Spacing 13 mm .512" Spacing 14,5 mm (.571") 13 mm block for blown fuse indicator (to be ordered separately). 14,5 mm block for blown fuse indicator (to be ordered separately).


    Original
    T01088 FU520 FU525 BJS131 FU520 PR30 FEM13U 14-26AWG T01088 26201 PDF

    ask 1 ld

    Contextual Info: Circuit Protection Terminals ASK 1 LD ASK 1 W arning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly


    OCR Scan
    PDF

    9802730000

    Contextual Info: KDKS 1 Circuit Protection Terminals KDKS 1 KDKS 1 PE Combi-foot Warning: • Install AP partition after last or KDKS 1. • Disconnect power before replacing the fuse. . Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures


    OCR Scan
    PDF

    0430700000

    Abstract: 0430500000 Fuse 0430900000 9503330000 04-3070-0000 043050
    Contextual Info: Circuit Protection Terminals KDKS 1 with power on indication combi-foot Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures


    Original
    PDF

    Accessories

    Abstract: Fuses A
    Contextual Info: DIAZED AND NEOZED ACCESSORIES SCREW CAP The Screw Cap types offered fit the various fuse and Fuse Base sizes. They hold the fuses in place and connect the head of the fuse with the load side of the Fuse Holder. The colored blown fuse indicator on the head of the fuse is


    Original
    5/250V NHTC00 NHB00-1-3 Accessories Fuses A PDF

    Contextual Info: Circuit Protection Terminals ZSI 2.5 with blown fuse indicator Warning: for AC or DC voltage • Install ZAP TNHE fuse cover and ZAP end plate after last ZSI 2.5. W . • Disconnect power before replacing the fuse. \ j- Fuse terminals are available it . tsrfefD ISM .


    OCR Scan
    PDF

    33740

    Abstract: 337-40 blown fuse indicator 9134531111
    Contextual Info: Circuit Protection Terminals KDKS 1 with power on indication combi-foot Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures


    Original
    PDF

    6SC30A3

    Abstract: 6SC30A1 ATQR Fuses LR21455 KTK Fuses 6SC30A1I blown fuse indicator Marathon 6SC30A4 ATQR ATDR Fuses
    Contextual Info: Class CC Enclosed Fuse Holders - 600 Volt Specifications: Tested and Approved for 200,000 Amps Short Circuit Withstand Rating Touchsafe IEC Type Design IP20 DIN Rail Mount (35mm - symmetrical) Blown Fuse Indication Available Red dual LED indicator - range of operating


    Original
    10-600V E35113 LR21455 6SC30A3I-D 6SC30A1I-D 6SC30A1-D 6SC30A2-D 6SC30A3-D 6SC30A3 6SC30A1 ATQR Fuses LR21455 KTK Fuses 6SC30A1I blown fuse indicator Marathon 6SC30A4 ATQR ATDR Fuses PDF

    24VAC LED Lamp

    Abstract: H-12V H9907 VU-MX Neon Lamp
    Contextual Info: Terminal Blocks with Components W SI6LD Blown Fuse Indication Fuse cartridge, 5 x 2 0 WSI 6/2 LD DISC Fuse cartridge, VUmx 1/4M 5x25 5x30 with LED indicator with LED indicator for DC or A C voltage Note: Note: In the event of a faulty fuse, the connected circuit has a max


    OCR Scan
    230VAC 11VAC 24VAC LED Lamp H-12V H9907 VU-MX Neon Lamp PDF

    i2t motor protection

    Abstract: THERMAL Fuse 220v ac fan termoswitch fuse t6 scr 220v GOA94020 GOA95020 06A50
    Contextual Info: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx20 THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    GOA9xx20 GOA94020 GOA95020 GOA9xx20T001 i2t motor protection THERMAL Fuse 220v ac fan termoswitch fuse t6 scr 220v GOA94020 GOA95020 06A50 PDF

    Contextual Info: Circuit Protection Terminals ZDL 2.5/SI/DU/PE ZTR 2.5/SI ZDL 2.5/SI/DU Warning: 1 •Disconnect power before % ii B replacing the fuse. Fuse terminals are available with LED blown fuse indica­ • tors, which speed identifica­ tion of fuse failures and reduce costly down time. The


    OCR Scan
    PDF

    Contextual Info: Cartridge Fuse Holders Enclosed Fuseholders > Panel Mounted 344/348 Series Blown Fuse Indicating / Low Profile Holders for 3AG Fuses 344 Series Indicating 348 Series (Low Profile) Product Characteristics Compatible Fuses For 3AG Type Fuses Features Low profile design


    Original
    PDF

    220v ac fan

    Abstract: termoswitch GOA94024 GOA95024 AC 220v fan motor
    Contextual Info: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx24 THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    GOA9xx24 GOA94024 GOA95024 GOA9xx24T001 220v ac fan termoswitch GOA94024 GOA95024 AC 220v fan motor PDF

    220v ac fan

    Abstract: GPTP2220-16 fuses 1400a thyristor 230 V 5 kW GOA94014
    Contextual Info: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx14 1400A AC SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    GOA9xx14 GOA94014 GOA9xx14T001 220v ac fan GPTP2220-16 fuses 1400a thyristor 230 V 5 kW PDF

    220v ac fan

    Abstract: GOA94010 GOA95010 termoswitch fuse f3 fuse t6
    Contextual Info: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx10 THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    GOA9xx10 GOA94010 GOA95010 GOA9xx10T001 220v ac fan GOA94010 GOA95010 termoswitch fuse f3 fuse t6 PDF

    3 phase fuse board

    Abstract: 600A thyristor scr microswitch v3 scr snubber design snubber of scr
    Contextual Info: Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx06C THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches


    Original
    GOA9xx06C GOA94006C GOA95006C GOA9xx06CT002 3 phase fuse board 600A thyristor scr microswitch v3 scr snubber design snubber of scr PDF