    BLOWN F Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LM2907N/NOPB
    Texas Instruments Frequency to Voltage Converter 14-PDIP -40 to 85 Visit Texas Instruments Buy
    LM2907M-8/NOPB
    Texas Instruments Frequency to Voltage Converter 8-SOIC -40 to 85 Visit Texas Instruments Buy
    LM2907MX-8/NOPB
    Texas Instruments Frequency to Voltage Converter 8-SOIC -40 to 85 Visit Texas Instruments Buy
    LM2907M-8
    Texas Instruments Frequency to Voltage Converter 8-SOIC -40 to 85 Visit Texas Instruments
    LM2907N-8/NOPB
    Texas Instruments Frequency to Voltage Converter 8-PDIP -40 to 85 Visit Texas Instruments Buy
    SF Impression Pixel

    BLOWN F Price and Stock

    Select Manufacturer

    Eaton Cutler-Hammer BLOWNF0001R

    BLOWN FUSE KIT, 800-4000A
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS BLOWNF0001R Bulk 5 Weeks 1
    • 1 $2188.96
    • 10 $2188.96
    • 100 $2188.96
    • 1000 $2188.96
    • 10000 $2188.96
    Get Quote

    Littelfuse Inc 03440125H

    Fuse Holder BLOWN FUSE INDICATING 3AG/3AB
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03440125H Kit 85 5
    • 1 -
    • 10 $28.89
    • 100 $23.70
    • 1000 $23.23
    • 10000 $23.23
    Buy Now

    Littelfuse Inc 03440024H

    Fuse Holder - Use 576-03440024H
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03440024H Kit 52 1
    • 1 $42.38
    • 10 $34.27
    • 100 $30.78
    • 1000 $30.46
    • 10000 $30.46
    Buy Now

    Littelfuse Inc 03440250H

    Fuse Holder BLOWN FUSE INDICATING 3AG/3AB
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI 03440250H Kit 5
    • 1 -
    • 10 $28.30
    • 100 $21.79
    • 1000 $21.15
    • 10000 $21.15
    Buy Now

    Documents mentioning BLOWN F

    Document Partial File Text Tags Type PDF
    Bussmann® Pin Indicating Type FNA Dual-Element,
    Bussmann® Pin Indicating Type FNA Dual-Element, Time-Delay 1/10–30 Amps Dimensional Data Time-Current Characteristic CurvesÐAverage Melt 0.406" (blown) AMPERE RATING 15 20 100 0.343" (blown) 0.343" 1 (‫ע‬0.004) 0.063" 1.5" (‫ע‬0.031) (not blown)
    Original PDF
    Bussmann® Pin Indicating Type FNA Dual-Element,
    Bussmann® Pin Indicating Type FNA Dual-Element, Time-Delay 1/10–30 Amps Dimensional Data Time-Current Characteristic Curves–Average Melt 0.406" (blown) AMPERE RATING 15 20 100 0.343" (blown) 0.343" 1 (‫ע‬0.004) 0.063" 1.5" (‫ע‬0.031) (not blown)
    Original PDF
    ZSI 2.5/2 Circuit Protection Terminals with blown
    ZSI 2.5/2 Circuit Protection Terminals with blown fuse indicator for AC or DC voltage Warning: •Install ZAP TNHE fuse cover plate after last ZSI 2.5/2. •Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indica­
    OCR Scan PDF
    Circuit Protection Terminals KDKS 1/PE with blown
    Circuit Protection Terminals KDKS 1/PE with blown fuse indicator (BFI) and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which
    OCR Scan PDF
    WSI 6/2 Circuit Protection Terminals with blown
    WSI 6/2 Circuit Protection Terminals with blown fuse indicator Warning: for AC or DC voltage. • Install WAP partition after last WSI 6/2. • Disconnect power before replacing the fuse. Fuse terminals are available with I LED blown fuse indicators, which
    OCR Scan PDF
    Pin-Indicating Type GLD/GBA Fast-Acting 1 ⁄4˝ x 1
    Pin-Indicating Type GLD/GBA Fast-Acting 1 ⁄4˝ x 1 1⁄4˝ (6.3mm x 32mm) Dimensions - in 1.27" (±0.031) (32.2mm) (not blown) 15 8 10 5 3 2 100 0.75 1 Time-Current Characteristic Curves–Average Melt AMP RATING 1.44" (36.5mm) (blown) 1 CURRENT IN AMPS
    Original PDF
    Circuit Protection Terminals ASK 1 combi-foot
    Circuit Protection Terminals ASK 1 combi-foot with blown fuse indicator (BFI) Warning: and circuit disconnect • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which
    OCR Scan PDF
    Circuit Protection Terminals WSI 6 with blown
    Circuit Protection Terminals WSI 6 with blown fuse indicator Warning: for AC or DC voltage • Install WAP partition after last WSI 6. • Disconnect power before replacing the fuse. ï Fuse terminals are available with it i n *“ 1,1 ï ■ r I' LED blown fuse indicators, which
    OCR Scan PDF
    blown fuse indicator
    Product Data Sheet 6SM30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Midget Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m)
    Original PDF
    blown fuse indicator
    Product Data Sheet 6SC30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Class CC Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m)
    Original PDF
    t01088
    T01088 020128 MU 10/13.SF1 Fuse holder terminal blocks for 5 x 20 mm and 5 x 25 mm fuses Compression clamp MU 10/14,5.SF1 Spacing 13 mm (.512") Spacing 14,5 mm (.571") 13 mm block for blown fuse indicator (to be ordered separately). 14,5 mm block for blown fuse indicator (to be ordered separately).
    Original PDF
    Pre-Engineered Solutions LCP Fused Coordination
    Pre-Engineered Solutions LCP Fused Coordination Panel Standard Features • 3 Different Voltage Ratings • Copper Bus • Branch Circuit Breakers Coordinated w/ Class CC Fuses • Class CC Fuse Holders have Built-In Blown Fuse Indication • Multiple NEMA Enclosures
    Original PDF
    high-performance custom bulk cable for interconnect applications
    SERIES 96 High-Performance Custom Bulk Cable for Interconnect Applications Rugged environmental jacketing in a broad range of material types and colors „„ Extruded, blown-on and heat shrink jacketing for harsh application environments „„ General purpose polyurethane
    Original PDF
    tricore
    Preliminary DProbeTriCore The Modular Tool Chain HiLights Sophisticated HLL-debugging software: - easy to use - watch/examine for variables - full-blown symbol manager - save execution trace to disk - batch/macro file processing - on-line help function - generator for creating user-defined
    Original PDF
    Class CC Enclosed Fuse Holders - 600 Volt
    Class CC Enclosed Fuse Holders - 600 Volt Specifications: Tested and Approved for 200,000 Amps Short Circuit Withstand Rating Touchsafe IEC Type Design (IP20) DIN Rail Mount (35mm - symmetrical) Blown Fuse Indication Available Red dual LED indicator - range of operating
    Original PDF
    Circuit Protection Terminals KDKS 1 with power on
    Circuit Protection Terminals KDKS 1 with power on indication with blown fuse indicator (BFI) and circuit disconnect Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with
    OCR Scan PDF
    Phone: +39-010-659 1869 Fax: +39-010-659 1870
    Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx20 THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches
    Original PDF
    Phone: +39-010-659 1869 Fax: +39-010-659 1870
    Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy GOA9xx24 THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches
    Original PDF