    CN-DSUB50PIN0-000 Amphenol Cables on Demand Amphenol CN-DSUB50PIN0-000 D-Subminiature (DB50 Male D-Sub) Connector, 50-Position Pin Contacts, Solder-Cup Terminals Datasheet
    CN-DSUBHD62PN-000 Amphenol Cables on Demand Amphenol CN-DSUBHD62PN-000 High-Density D-Subminiature (HD62 Male D-Sub) Connector, 62-Position Pin Contacts, Solder-Cup Terminals Datasheet
    CN-DSUB25SKT0-000 Amphenol Cables on Demand Amphenol CN-DSUB25SKT0-000 D-Subminiature (DB25 Female D-Sub) Connector, 25-Position Socket Contacts, Solder-Cup Terminals Datasheet
    CN-DSUBHD26SK-000 Amphenol Cables on Demand Amphenol CN-DSUBHD26SK-000 High-Density D-Subminiature (HD26 Female D-Sub) Connector, 26-Position Socket Contacts, Solder-Cup Terminals Datasheet
    CN-DSUB15PIN0-000 Amphenol Cables on Demand Amphenol CN-DSUB15PIN0-000 D-Subminiature (DB15 Male D-Sub) Connector, 15-Position Pin Contacts, Solder-Cup Terminals Datasheet

    AUXILIARY CONTACTS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    1SBC100122C0201

    Abstract: R1008 R3311 AF MARKING CODE contactors
    Text: Auxiliary Contact Blocks Side Mounting Application The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. Description SB7375C2 Types of auxiliary contacts blocks in standard version for general use: CAL 5-11 ●


    Original
    PDF SB7375C2 5-11B R1011 5-11B R3311 R1008 1SBC100122C0201 1SBC100122C0201 R1008 R3311 AF MARKING CODE contactors

    T3-4-15682

    Abstract: MOTOR CONTROL SWITCHES MOELLER IEC 60947 VDE 0660 moeller VDE 0660 AC-21A IEC/EN 60947-3 VDE 0660 IEC EN 60947-3 IEC 60947-3 MOELLER AC21A
    Text: Type: T3−4−15682/I2/SVB Article No.: 207210 Ordering information Design Surface mounting Description With auxiliary contacts Main conducting paths No. of poles M 6 Auxiliary contacts N/O 1 Auxiliary contacts B 1 Max. three−phase motor rating per set


    Original
    PDF T3-4-15682/I2/SVB T8-3-8342/. AC-21A D-53115 HPL-C2006GB-INT T3-4-15682 MOTOR CONTROL SWITCHES MOELLER IEC 60947 VDE 0660 moeller VDE 0660 IEC/EN 60947-3 VDE 0660 IEC EN 60947-3 IEC 60947-3 MOELLER AC21A

    KW ac motor

    Abstract: 37 KW motor 50 KW dc motor IEC 60947-3 MOELLER
    Text: Type: P5−315/V/SVB Article No.: 280956 Ordering information Design Rear mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-315/V/SVB D-53115 HPL-C2006GB-INT KW ac motor 37 KW motor 50 KW dc motor IEC 60947-3 MOELLER

    moeller VDE 0660 iec 947-3

    Abstract: VDE 0660 iec 947-3 moeller VDE 0660 iec 947 P3100EA IEC 947-3 VDE 0660 90 KW motor P3-100 AC-21A
    Text: Type: P3−100/EA/SVB Article No.: 074320 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P3-100/EA/SVB NEMA12, NEMA13 AC-21A D-53115 HPL-C2006GB-INT moeller VDE 0660 iec 947-3 VDE 0660 iec 947-3 moeller VDE 0660 iec 947 P3100EA IEC 947-3 VDE 0660 90 KW motor P3-100

    3RV29011A

    Abstract: 220VA DC-13
    Text: Product data sheet 3RV2901-1A LATERAL AUXILIARY SWITCH 1NO+1NC, SCREW CONNECTION, FOR CIRCUIT-BREAKERS, SZ S00/S0 General technical data: Product brand name SIRIUS Product designation auxiliary switch, lateral Design of the product lateral auxiliary switches


    Original
    PDF 3RV2901-1A S00/S0 com/WW/view/en/3RV2901-1A/all 3RV29011A 220VA DC-13

    220VA

    Abstract: DC-13 3RV2901-2B
    Text: Product data sheet 3RV2901-2B LATERAL AUXILIARY SWITCH 2S, SPRING-L. CONNECTION, FOR CIRCUIT-BREAKERS, SZ S00/S0 General technical data: Product brand name SIRIUS Product designation auxiliary switch, lateral Design of the product lateral auxiliary switches


    Original
    PDF 3RV2901-2B S00/S0 com/WW/view/en/3RV2901-2B/all 220VA DC-13 3RV2901-2B

    DC-13

    Abstract: 220VA
    Text: Product data sheet 3RV2901-2C LATERAL AUXILIARY SWITCH 2NC, SPRING-L. CONNECTION, FOR CIRCUIT-BREAKERS, SZ S00/S0 General technical data: Product brand name SIRIUS Product designation auxiliary switch, lateral Design of the product lateral auxiliary switches


    Original
    PDF 3RV2901-2C S00/S0 com/WW/view/en/3RV2901-2C/all DC-13 220VA

    3RV2901-2A

    Abstract: 220VA DC-13
    Text: Product data sheet 3RV2901-2A LATERAL AUXILIARY SWITCH 1NO+1NC, SPRING-L. CONNECTION, FOR CIRCUIT-BREAKERS, SZ S00/S0 General technical data: Product brand name SIRIUS Product designation auxiliary switch, lateral Design of the product lateral auxiliary switches


    Original
    PDF 3RV2901-2A S00/S0 com/WW/view/en/3RV2901-2A/all 3RV2901-2A 220VA DC-13

    IEC 60947-3 MOELLER

    Abstract: P5-160 50 KW dc motor
    Text: Type: P5−160/V/SVB Article No.: 280928 Ordering information Design Rear mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-160/V/SVB D-53115 HPL-C2006GB-INT IEC 60947-3 MOELLER P5-160 50 KW dc motor

    50 KW dc motor

    Abstract: 110 KW motor .37 KW motor DC23a Moeller HPL AC-21A
    Text: Type: P5−315/EA/SVB Article No.: 280950 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-315/EA/SVB D-53115 HPL-C2006GB-INT 50 KW dc motor 110 KW motor .37 KW motor DC23a Moeller HPL AC-21A

    90 KW motor

    Abstract: 37 KW motor 50 KW dc motor
    Text: Type: P5−250/E Article No.: 280935 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-250/E D-53115 HPL-C2006GB-INT 90 KW motor 37 KW motor 50 KW dc motor

    EN 60947-3

    Abstract: 37 KW motor P5-160
    Text: Type: P5−160/EA/SVB Article No.: 280922 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-160/EA/SVB D-53115 HPL-C2006GB-INT EN 60947-3 37 KW motor P5-160

    37 KW motor

    Abstract: No abstract text available
    Text: Type: P5−160/E Article No.: 280921 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-160/E D-53115 HPL-C2006GB-INT 37 KW motor

    AC21A

    Abstract: IEC 60947-3 MOELLER AC-21A IEC EN 60947-3 EN60204
    Text: Type: P3−100/E Article No.: 067201 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P3-100/E AC-21A D-53115 HPL-C2006GB-INT AC21A IEC 60947-3 MOELLER IEC EN 60947-3 EN60204

    catalogue of torque switch

    Abstract: No abstract text available
    Text: Type: P5−125/V/SVB Article No.: 280914 Ordering information Design Rear mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-125/V/SVB D-53115 HPL-C2006GB-INT catalogue of torque switch

    90 KW motor

    Abstract: 50 KW dc motor 37 KW motor moeller 1250 DC-23A
    Text: Type: P5−250/V/SVB Article No.: 280942 Ordering information Design Rear mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-250/V/SVB D-53115 HPL-C2006GB-INT 90 KW motor 50 KW dc motor 37 KW motor moeller 1250 DC-23A

    190 KW ac motor

    Abstract: AC21A AC-21A 150 KW dc motor IEC/EN 60947-3 150 KW motor 60947-3 90 KW motor VDE 0660 iec 60947-3
    Text: Type: P1−25/E Article No.: 038724 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P1-25/E AC-21A D-53115 HPL-C2006GB-INT 190 KW ac motor AC21A 150 KW dc motor IEC/EN 60947-3 150 KW motor 60947-3 90 KW motor VDE 0660 iec 60947-3

    IEC 60947-3 MOELLER

    Abstract: No abstract text available
    Text: Type: P3−100/I5/SVB Article No.: 207373 Ordering information Design Surface mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P3-100/I5/SVB AC-21A D-53115 HPL-C2006GB-INT IEC 60947-3 MOELLER

    90 KW motor

    Abstract: 50 KW dc motor AC21A
    Text: Type: P5−250/EA/SVB Article No.: 280936 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-250/EA/SVB D-53115 HPL-C2006GB-INT 90 KW motor 50 KW dc motor AC21A

    P5125

    Abstract: 37 KW motor
    Text: Type: P5−125/EA/SVB Article No.: 280898 Ordering information Design Flush mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-125/EA/SVB D-53115 HPL-C2006GB-INT P5125 37 KW motor

    IEC/EN 60947-3

    Abstract: AC-21A 150 KW motor 90 KW motor IEC 60947 VDE 0660 NFEN60947-2 iec 60947-3 15 KW motor VDE 0660 moeller VDE 0660 en 60204-1
    Text: Type: P1−25/I2/SVB Article No.: 207293 Ordering information Design Surface mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P1-25/I2/SVB AC-21A D-53115 HPL-C2006GB-INT IEC/EN 60947-3 150 KW motor 90 KW motor IEC 60947 VDE 0660 NFEN60947-2 iec 60947-3 15 KW motor VDE 0660 moeller VDE 0660 en 60204-1

    AC-21A

    Abstract: No abstract text available
    Text: Type: P3−63/I4 Article No.: 207356 Ordering information Design Surface mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P3-63/I4 AC-21A D-53115 HPL-C2006GB-INT

    catalogue of torque switch

    Abstract: 37 KW motor 15 KW motor 50 KW dc motor
    Text: Type: P5−160/EA/SVB/HI10 Article No.: 280923 Ordering information Design Flush mounting Description With auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    PDF P5-160/EA/SVB/HI10 D-53115 HPL-C2006GB-INT catalogue of torque switch 37 KW motor 15 KW motor 50 KW dc motor

    ESSEX ss9 5ls

    Abstract: CETA
    Text: O&ÜE Installation - CETA auxiliary contacts When fitting to CETA25/32 contactors depress bridge slightly when sliding contact block into position. lock into position. Ratings: auxiliary contacts Maximum number of auxiliary contacts = 4 10A Ith max_


    OCR Scan
    PDF CETA25/32 ESSEX ss9 5ls CETA