Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ASEA SETTING RELAY INDICATOR Search Results

    ASEA SETTING RELAY INDICATOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCK301G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK304G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK305G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK321G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet
    TCK323G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet

    Documents mentioning ASEA SETTING RELAY INDICATOR

    Document Partial File Text Tags Type PDF
    asea
    Al lili **IPIP ASEA B R O W N BOVERI ABB Relays Over- or under-frequency relay assem blies ( T r r \ ^ I r r y Abstract Application • Wide setting ranges, 50 Hz relay: 44.41 -50 .7 3 Hz or 44.41-59.15 Hz 60 Hz relay: 53.07-60.62 Hz or 53.07-70.68 Hz • Settings in steps w ith the resolution,
    OCR Scan PDF
    asea
    A S !» ASEA B R O W N BO VERI ------------------ — ABB Relays Abstract • ----------------------“ , ■ Type RATUB B03-5011 V/Hz overexcitation relay for transformers £ ^ ^ « *5 Two versions available 1.5 to 3 V/Hz setting range
    OCR Scan PDF
    Inie-No, AS EA RK 615-302 E Rag. Page 7433 1 Filé
    Inie-No, AS EA RK 615-302 E Rag. Page 7433 1 Filé RK 00-90 E Section 6 IHF0EMATI0H From/Dal« R3?R, Dec. 1975 Edit ioti 1 Reiay Division Distance relay type KAZOG o Static three-phase design o Switched scheme o Minimum operating time 20 m3 o Suitable for both overhead
    OCR Scan PDF
    rxih 2
    Info-N o. ASEA INFORMATION RK 413-300 E From /D ate Reg. Relay Division RFR, April 1970 Edition 1 5623 Page 1 Over-current relay type RXIH 2 Over-current relay RXIH 2 OUTSTANDING FEATURES • is built-up of static components • has out-put matched for a separate output relay
    OCR Scan PDF
    ASEA Catalogue RK 31-10 E Edition 2 November 1974
    ASEA Catalogue RK 31-10 E Edition 2 November 1974 Time-lag relay type RXKT 2 □ is available with tim e scales 0.2—2 s, 1—10 s, 6 -6 0 s and 0 .5 -5 min Is suitable fo r d.c. supply Requires no auxiliary voltage □ Is used in, for example, relay protections and automatic equipment for
    OCR Scan PDF
    rxkh
    ASEA Catalogue RK 31-11 E _ ^ LI Time-lag relay type RXKH • Pick-up de'ay with time-lag scales of 0 .3 -2 s up to 15-100 s • Belongs to the COMBI FLEX* modular system • For d.c. supply • Great accuracy; with time-lag scales of 3—20 s the dispersion is ± i % of
    OCR Scan PDF
    ASEA IriiO'Mu. RK 549-300 E ' ■ IINFORMATION R
    ASEA IriiO'Mu. RK 549-300 E ' ■ IINFORMATION R eg. FromrfQato Relay Division . T1TR, September 1977 Edition 1 Paga 5626 1 File RK 00“90 1 Section 5 Frequency relay type TFF 60 o Ability to supervise up to seven frequency levels o Dnder- or overfrequency design
    OCR Scan PDF
    , Catalogue RK 31-3 E A S E A ¥< ¿si. - February
    , Catalogue RK 31-3 E A S E A ¥< ¿si. - February 1971 Time-lag relay type RRKO m ■ Drop-out delayed relay with time-lag scales 0.4—2, 1.5—6 and 4—20 s ■ For d.c. or a.c. supply ■ Short recovery time Intended primarily for relay protections in power plants and similar equipment
    OCR Scan PDF
    asea
    ii B i n M llll ASEA BROWN BOVERI ABB Relays Abstract Application Type RANCE Microprocessor-controlled signal system with 4 to 128 indicators B03-8412E Page 1 January 1987 Changed since January 1985 Data subject to change without notice • Type RANCE is highly immune to interfer­
    OCR Scan PDF
    rxko
    A SEA Catalogue RK 31-13 E Drop-out-delayed time-lag relay type RXKO ■ Time-lag scales 0.4—2 s, 1.5—6 s and 4 -2 0 s ■ D.C. or a.c. supply, 15—60 Hz ■ Provided with a two-way contact ■ Short total resetting tim e ■ Designed for protective relay schemes
    OCR Scan PDF
    asea transformer
    ^■■r-vz ¡*L<: ‘ :.ÍS March 1968 Edition 1 ASEA Transformer differential protection RYDSA 20 C o n te n ts Outstanding features 3 Introduction 4 Operation S,7 ThTCygh-laiil; restraint 8,9 Three'ptiase Connection diagrams 10 ,1 1 Current transformers
    OCR Scan PDF
    asea
    Ak li li M IP IP ASEA BROW N BOVERI ABB Relays Voltage relay data table B03-2503E Page 1 January 1985 Changed since June 30, 1982 Data subject to change without notice Undervoltage relays Permitted auxiliary voltaqe deviation Static %^j [ Electromechanical
    OCR Scan PDF
    radhl
    ABB # * ü l» 1nfO‘Wü. ILK612-301 INFORMATION FiontfDitB Reg. E P4£6 ASEft B R O W N BOVÊRI RFR, January 1978 Edition 1 Relay Division 7434 1 Pile RK 00-90 E Section 6 Pilot-vire differential relay type RADHL for cables and overhead lines ___________________________________
    OCR Scan PDF
    raaak
    ASEA Relay Division Info-No. INFORMATION RK 851-300 From/Date Reg. RFR, September 1972 Edition 1 5651 E Page 1 Relay equipment type RAAAK for single-phase and three-phase auto-reclosing of high voltage circuit-breakers GENERAL The relay equipment for single-phase and three-phase auto­
    OCR Scan PDF
    razoa
    RE 615 001 ASEA TECHNICAL DATA FOE DISTANCE RELAY TYPE RAZOA GENERAL Rated frequency f 50 or 60 Hz Rated voltage U. n 100-110 V + 10 110-130 V + 10 Rated current I n 1 A, 2 A or 5 A Auxiliary voltage 48 or 110, 125 or 220, 250 T dc + 10 % - 20 % Tripping mode
    OCR Scan PDF
    razfe
    Inlo-No. ABB INFORMATION RK G13~30Û E From/Date Reg. ÏÏFR, November 1979 Edition 5 À-SÊA B R O W N S C - Y fR r ABB Relays Raya 7^33 1 File EK 00-90 E sectio n o Distance relay type RAZFel ASÉA; s-rsi 9Î V5&t$rô& Swiden o Static three-phase design
    OCR Scan PDF
    II II MilIP II ASEA BROWN BOVERI ABB Relays
    II II MilIP II ASEA BROWN BOVERI ABB Relays Abstract Application • Measures direct current, for instance at the voltage transformers’ neutral point connec­ tion to ground • Adjustable operate value 1 0 -1 5 mA • Adjustable operate time 0.3—3 s Page 1
    OCR Scan PDF
    47-1e
    C Î? E * JK Catalogue RK 47-1E H iM Edition 2 O ctober 1972 File R, Part 2 Time-lag overcurrent relays with inverse characteristic type Rl, RIS, RIDI and RIDSI • Operating tim e decreasing as the current increases, but practically constant tim e at very high currents.
    OCR Scan PDF
    Catalogue RK 65-17 E Edition 2 A p r ili 961 File
    Catalogue RK 65-17 E Edition 2 A p r ili 961 File R, Part 1 ■ Time-overcurrent protective relays • Used as short-circuit and earth-fault re lays for cables, power lines, machines and transformers • independent or inverse time-iag characteristic • One, two and three phase protection with separale m eas­
    OCR Scan PDF
    Catalogue RK 3 2 E ASEA Edition 2 February 1972
    Catalogue RK 3 2 E ASEA Edition 2 February 1972 File Ft, Part 2 Time-lag relay type RRKP • Tim e-lag scale 0.3 s to 60 h on the same relay. The scale is divided up into 6 scale ranges w ith progressive fine adjustm ent. External adjustm ents to the operating tim e and scale range
    OCR Scan PDF
    il Bill ASEA B R O W N BOVERI Type RXPF 4 *
    il Bill ASEA B R O W N BOVERI Type RXPF 4 * B03-3014E 1 P age 1 Directional ground-fault relay D a ta subject to c h a n g e without notte • N ew , Abstract v • Directional ground-fault relay for networks with isolated neutral point or networks with resistance grounded neutral point with or
    OCR Scan PDF
    Jk » 1 1 ' m. MFOHMTION fro n tfD a to
    Jk » 1 1 ' m. MFOHMTION fro n tfD a to aseasrownsoteri , _ ABB Relays Reg. HFR, A p ril 197© Edition 1 4S 1-300 3 Page 5627 1 F ile EK 00-90 Section 4 Thermal over current relay "type BXVE 4 For protection of motors, generators} transformers} and lines Eor d,c, or a.c, measurement
    OCR Scan PDF
    ~ Catalogue Edition 2 RK 32-10 May 1975 E File R,
    ~ Catalogue Edition 2 RK 32-10 May 1975 E File R, Part 1 0.3 s to 60 h for a.c. or d.c. supply .Pick-up delayed synchronous motordriven relay for a.c. supply or d.c. supply via a separate invertor .Time-lag scale 0.3 s to 60 h on the same relay. The scale is divided into 6
    Original PDF
    razog
    V Al l i l i A* IP IP ASEA BROWN BOVERI ABB Relays Type RAZOG B03-7013E Three-zone, phase and ground distance relay for transmission lines Abstract Application Data subject to change without notice >Three-phase and ground sequential mea­ surement distance relay for overhead lines
    OCR Scan PDF
    breaker failure relay
    41 » 1 ! M l » ASEA BROW N BOVERl INFORMATION FHS May 1989 RF 637 375E 1. Type RAICC Breaker Failure Relay (BFR) Introduction The RQDT 040 plug-in unit is a simple, but very effective and versatile, 3-phase current decting element incor­ porated in a new BFR-scheme. It can be used with ease in
    OCR Scan PDF