Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    APPLICATION ORIFICE PLATE Search Results

    APPLICATION ORIFICE PLATE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CN-ACPRREDAA0
    Amphenol Cables on Demand RCA Male Plug Cable Connector (Red) - Amphenol ACPR-RED - Gold Plated Diecast Shell PDF
    143-4142-11H
    Amphenol Communications Solutions Paladin RPO, DC, 4-Pair, 4 Column, APP PDF
    143-6262-11H
    Amphenol Communications Solutions Paladin RPO, DC, 6-Pair, 6 Column, APP PDF
    144-411D-11H
    Amphenol Communications Solutions Paladin RPO, DO, 4-Pair, 10 Column, 1.5mm Wipe, APP PDF
    144-411G-21H
    Amphenol Communications Solutions Paladin RPO, DO, 4-Pair, 16 Column, 2.25mm Wipe, APP PDF

    Documents mentioning APPLICATION ORIFICE PLATE

    Document Partial File Text Tags Type PDF
    orifice plate
    Data Sheet SS/DP Differential Pressure Flow Elements Issue 4  Comprehensive range of DP primary elements – including orifice plates, carrier assemblies, metering runs, nozzles, Venturi tubes, Torbar averaging pitot tubes, Wedge meters and meters for subsea use
    Original PDF
    Series 1 Inert isolation soleniod valves FEATURES
    Series 1 Inert isolation soleniod valves FEATURES · 3-way diaphragm valves · PTFE body and PTFE-insulated lead wires (also uses borosilicate glass wetted parts) · Offers coils rated for 100 % duty and contained in a nickel-plated steel housing · Uses low power
    Original PDF
    Data Sheet DS/OM Issue 2 Compact Orifice Flow
    Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster „ Integrated DP Flow measurement system – combines primary element with DP Transmitter in a single flowmeter assembly „ One-piece flowmeter, pressure tested as an assembly – improved reliability with no leaks to trace and rectify
    Original PDF
    Energy Saving Type 2 Port Solenoid Valve 1/3 For
    Energy Saving Type 2 Port Solenoid Valve 1/3 For Air/Water/Oil Power consumption (SMC comparison) Reduction of ng costs runni Reduction of supply capac r e w i po for facilities ty Reduction of CO2 Reduction of temperature increase New generation valve corresponding to energy-saving needs
    Original PDF
    CAT.EUS70-26 A -UK Direct Operated 3 Port
    CAT.EUS70-26 A -UK Direct Operated 3 Port Solenoid Valve For Water, Oil, Steam, Air Reduction of power consumption (DC specification) 4.5 W 8 W 7 W 11.5 W  10.5 W 6 W New VX 3 Series VX31/32 /33 Reduction of power consumption Improvement of corrosion
    Original PDF
    8032 INLINE Flow Switch with On/Off indicator •
    8032 INLINE Flow Switch with On/Off indicator • DN 5/16“ to 2“ orifice • Local indicator • Adjustable switching contact (transistor or relay) • Adjustable hysterisis and delay time Type 8032 can be combined with… Type S030 Fitting Type 6013 Type 6213
    Original PDF
    LG Series Flow Measurement Throttle Devices
    LG Series Flow Measurement Throttle Devices Throttle orifice Injecting nozzle device Direct-reading throttle orifice flow meter Venturi tube throttling device Part one Summary Preface Throttle device is the most historic and most extensively used flow measurement instrument. It features itself
    Original PDF
    CAT.EUS70-23 A -UK Direct Operated 2 Port
    CAT.EUS70-23 A -UK Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air New Series VX21/22 /23 Reduction of power consumption (DC specification) 4.5 W 4. 8 WǞ 7 W 10. 0.5 W 11.5 1.5 W Ǟ 10.5 6 WǞ Low power consumption type: 0. W 0.8 (Held at 24 VDC)
    Original PDF
    User Guide IM/OMM Issue 2 Compact Orifice Flow
    User Guide IM/OMM Issue 2 Compact Orifice Flow Meter OriMaster M ABB The Company EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental
    Original PDF
    vdw200
    CAT.ES70-20 A Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Series VDW VDW10/20/30: 2 Port, VDW200/300: 3 Port Compact/Light weight (compared to series VX) Single valve volume: Reduced 75% (VDW20) 100g: Reduced approx. 50% (for orifice size equivalent to ø2)
    Original PDF
    solenoid valve
    VSO® Normally closed proportional solenoid valve FEATURES · 2-way normally closed · Offers operating pressure up to 150 psig and a range of orifice sizes · Satisfies a 0.2 sccm leakage specification of He for 100 million life cycles and offers high repeatability
    Original PDF
    vxz22
    Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve For Air, Water, Oil Reduced power consumption (DC spec.) 7W VXZ23: 11.5 W → 10.5 W VXZ22: 8 W → New VX Z Series VXZ22/23 CAT.EUS70-31A-UK Solenoid valves for various fluids used in a wide variety of
    Original PDF
    Notice of Intellectual Property Rights The OMEGA®
    Notice of Intellectual Property Rights The OMEGA® Handbook Series is based upon original intellectual property rights that were created and developed by OMEGA. These rights are protected under applicable copyright, trade dress, patent and trademark laws. The distinctive, composite appearance of these Handbooks is uniquely identified with
    Original PDF
    Direct Operated 2 Port Solenoid Valve For Air
    Direct Operated 2 Port Solenoid Valve For Air Series VCA Improved durability (Nearly twice the life of the previous series) VC„ Resistance of moving parts has been reduced. Service life and wear resistance are improved. VDW Large flow rate: TV factor 0.33 to 2.11
    Original PDF
    2600t
    Operating instructions 2600T Series Pressure Transmitters Model 267C Model 269C Contents 1 1 Safety Page Safety… 2 General safety precautions and health protection… 2
    Original PDF
    267cs
    Data Sheet SS/267CS/269CS Series 2600T Pressure Transmitters Model 267CS/269CS Multivariable for mass flow, selectable maximum working pressure up to 41 MPa, 5945 psi ■ Base accuracy: ± 0.075 %/± 0.04 % ■ Span limits – 0.05 to 2000 kPa; 0.2 in H2O to 290 psi
    Original PDF
    269cs
    Data Sheet FieldIT SS/269CS_4 2600T Series Pressure Transmitters Model 269CS Multivariable for mass flow selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.04% ■ Span limits – 0.05 to 2000kPa, 0.2inH2O to 290psi differential
    Original PDF
    267cs
    Data Sheet FieldIT SS/267CS_4 2600T Series Pressure Transmitters Model 267CS Multivariable for mass flow selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.075% ■ Span limits – 0.05 to 2000kPa, 0.2inH2O to 290psi differential
    Original PDF
    Issued March 1997 232-4184 Data Pack G Dashpot
    Issued March 1997 232-4184 Data Pack G Dashpot dampers Data Sheet RS stock numbers 751-146, 751-152, 751-168, 751-174, 751-180, 751-196, 751-203 Applications ● Prevent damage to sensitive equipment from shock and vibration ● Reduce impact noise ● Damping extreme movements
    Original PDF
    2-Colour Display Digital Flow Switch Flow rate
    2-Colour Display Digital Flow Switch Flow rate range: 10, 25, 50,100 l/min. Minimum unit setting: 0.01 l/min. Fluid (0.1 l/min when the flow rate range is 25, 50, 100 l/min.) Air, N2, Ar, CO2 Repeatability: ±1%F.S. or less Grease-free Flow adjustment valve is integrated.
    Original PDF
    Issued March 1997 232-3721 Data Pack G Vacuum
    Issued March 1997 232-3721 Data Pack G Vacuum generators Data Sheet Specifications Fluid ________________________________________Air Operating pressure range ____________2.5~6kgf/cm2 Max. operating pressure__________________7kgf/cm2 Operating temperature range ______________5~60°C
    Original PDF
    G21/GSR21 Corp. 9815−L9 Revised 10−2001 Service
    G21/GSR21 Corp. 9815−L9 Revised 10−2001 Service Literature G21/GSR21 SERIES UNITS G21 and GSR21 units are condensing furnaces utilizing the pulse combustion process. Initially, combustion takes place in an enclosed chamber. Then, as combusĆ tion products pass through the heat exchanger system
    Original PDF