    AMPMODU INTERMEDIATE PRESSURE Search Results

    AMPMODU INTERMEDIATE PRESSURE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TRF37C32IRTVT
    Texas Instruments 1700M-3800MHz Dual Down Converter Mixer with Integrated IF Amp 32-WQFN -40 to 85 Visit Texas Instruments Buy
    TRF37C32IRTVR
    Texas Instruments 1700M-3800MHz Dual Down Converter Mixer with Integrated IF Amp 32-WQFN -40 to 85 Visit Texas Instruments
    TRF37B32IRTVR
    Texas Instruments 700M-2700MHz dual Down Converter Mixer with Integrated IF Amp & RF Baluns 32-WQFN -40 to 85 Visit Texas Instruments
    TRF37A32IRTVT
    Texas Instruments 400M-1700MHz Dual Down Converter Mixer with Integrated IF Amp & RF Baluns 32-WQFN -40 to 85 Visit Texas Instruments Buy
    AFE8221IRFPQ1
    Texas Instruments Automotive Catalog Dual IF Interface for Digital Radio 144-HTQFP -40 to 85 Visit Texas Instruments Buy

    Documents mentioning AMPMODU INTERMEDIATE PRESSURE

    Document Partial File Text Tags Type PDF
    AMPMODU Interconnection System Mod IV Receptacle
    AMPMODU Interconnection System Mod IV Receptacle Contacts Crimp Snap-In Receptacles with Insulation Support (Standard, Intermediate and High Pressure) Standard Pressure A .058 [1.47] Material and Finish Mod IV Contacts Beryllium copper, phosphor bronze or
    Original PDF
    AMPMODU Interconnection System Mod IV Receptacle
    AMPMODU Interconnection System Mod IV Receptacle Contacts Crimp Snap-In Receptacles with Insulation Support (Standard, Intermediate and High Pressure) Standard Pressure A .058 [1.47] Material and Finish: Beryllium copper, phosphor bronze or copper-tin-phosphor bronze (see charts,
    Original PDF
    AMPMODU .025 Square Interconnection System
    AMPMODU .025 Square Interconnection System Specifications subject to change. For latest design specifications… 1 -8 0 0 -5 2 2 -6 7 5 2 of packaging," the AMPMODU .025 square interconnection system is primarily used in levels three and four. In level three it is used as a
    OCR Scan PDF
    AMPMODU Interconnection System European Standard
    AMPMODU Interconnection System European Standard Products AMPMODU Interconnection System METRIC Catalogue 1773393 Dimensions are millimetres over inches 3.96mm [.156”] Centerline Interconnection System 2.54mm [.100”] Centerline Interconnection System Italian Range
    Original PDF
    Catalog 1307612 AMPMODU .100 [2.54] Centerline
    Catalog 1307612 AMPMODU .100 [2.54] Centerline Revised 7-01 Technical Documents for Board-to-Board Products Various technical documents are available for your use. Product Specifications describe technical performance characteristics and verification tests,
    OCR Scan PDF
    Interconnection Systems .025 Square
    Interconnection Systems .025 Square Interconnection System (AMPMODU) Selection Guide 82750 Revised 7-95 Receptacle Assemblies, Vertical Mount Printed Circuit Board Connectors .025 Square Interconnection System (AMPMODll) Product Facts ■ Dual-cantilever beam contact
    OCR Scan PDF
    AMPMODU Interconnection System Technical
    AMPMODU Interconnection System Technical Documents for Board-to-Board Products Technical Documents Various technical documents are available for your use. Product Specifications describe technical performance characteristics and verification tests. They are intended for the Design, Component and Quality Engineers.
    Original PDF
    AMPMODU Interconnection System Wire-to-Board,
    AMPMODU Interconnection System Wire-to-Board, .100 [2.54] Centerline Products Wire Sizes Contact Platings Wire-to-Board Products Mating Post Lengths Wire Size AWG [mm2] 20 0.5-0.6 22-30 0.3-0.05 32 0.03 Platings .000015 [0.00038] Gold .000030 [0.00076] Gold
    Original PDF
    1-215299-2 Products for Industrial Applications
    1-215299-2 Products for Industrial Applications Search By TYCO Part Number Pages 1206-1296 AMPMODU 3.96 mm [.156"] Centerline Interconnection System METRIC Catalogue 1654741 Dimensions are millimetres over inches Revised 7-07 Product Facts Rugged connector system
    Original PDF
    AMP INCORPOR ATED EOE D ■ 07T731E ODlflTOS S ■ P
    AMP INCORPOR ATED EOE D ■ 07T731E ODlflTOS S ■ P l'D 't S AMPMODU MT Replacement Receptacle Contacts Dimensioning: Dim ensions are in inches and m illim eters. Values in brackets are m etric equivalents. (Continued) Charts contain dim ensions in inches over
    OCR Scan PDF
    AMP Catalog 1307612 AMPMODU Interconnection
    AMP Catalog 1307612 AMPMODU Interconnection System Revised 7-01 Mating Post Selection Guide The following selection guide is provided to help in choosing a mating product after a receptacle, header or post has been selected. Posts With Shoulders For drawn wire products
    OCR Scan PDF
    AMP EOE D INCORPORATED ■ 07T731S OGIÔTOS S ■ Pl’D
    AMP EOE D INCORPORATED ■ 07T731S OGIÔTOS S ■ Pl’D 'tS JUMP AMPMODU MT Replacement Receptacle Contacts Dimensioning: Dim ensions are in inches and m illim eters. Values in brackets are m etric equivalents. (C o n tin u e d ) Charts contain dim ensions In inches over
    OCR Scan PDF
    25003
    Application Specification 114-- 25003 AMPMODU* MOD IV, IV1/2, and V Receptacles and Housings NOTE i 02 NOV 09 Rev L All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Specifications subject to change. ACTION PIN
    Specifications subject to change. ACTION PIN Headers— Unshrouded and Shrouded For latest design specifications… 1-800-522-6752 Dimensioning: Dimensions are in inches Product Facts ■ Straight posted unshrouded and shrouded versions ■ .025 square posts with
    OCR Scan PDF
    AMPMODU Interconnection System Application
    AMPMODU Interconnection System Application Tooling for Wire Crimp Contacts Tooling shown on this page is designed to terminate wire crimp contacts used in various AMPMODU wire-toboard connectors. Refer to page 87 to determine the applicable connectors. AMP-O-LECTRIC Model “G” Terminating Machine
    Original PDF
    AMPMODU Interconnection System Locking Clip
    AMPMODU Interconnection System Locking Clip Contacts and Housings Product Facts ■ Self-retaining contacts provide permanent connection with quick connect and disconnect ■ Fast, easy installation with no additional locking hardware required ■ Mates with .025 [0.64]
    Original PDF