Untitled
Abstract: No abstract text available
Text: SERIES 23 MIL-STD-1560 contact arrangements Reference information Environmental and Hermetic Contact Arrangements A Contact Size #23 High-Density HD 5 Amp Max. Current #22-#28 AWG Size #22D 5 Amp Max. Current #22-#24 AWG Size #20 7.5 Amp Max. Current #20-#24 AWG
|
Original
|
PDF
|
MIL-STD-1560
25-18of
|
Untitled
Abstract: No abstract text available
Text: CON-C5 5-Pin Standard Connector Page 1 of 1 Description Standard AMP MTA female connector and 5 pins for 22-26 AWG wires. Ordering Information CON-C5 Wire Gauge Color, AMP # 22 =22 (Red, 640440-5) 24 =24 (Natural, 640441-5) 26 =26 (Blue, 640442-5) Notes
|
Original
|
PDF
|
|
electrical load
Abstract: No abstract text available
Text: E307105 6-7 3 Pole with Ground, 10 AMP 14-15 16 Pole with Ground, 16 AMP 8-9 4 Pole with Ground, 10 AMP 16-17 24 Pole with Ground, 16 AMP 10-11 6 Pole with Ground, 16 AMP 18-19 32 Pole with Ground, 16 AMP 12-13 10 Pole with Ground, 16 AMP 20-21 48 Pole with Ground, 16 AMP
|
Original
|
PDF
|
E307105
29015M
300-012010-5M
electrical load
|
Series 80 Mighty Mouse Contact Arrangements
Abstract: No abstract text available
Text: Mil-Spec Series 80 Mighty Mouse Contact Arrangements Contact Size B Size #23 Contacts 5 Amp Max. Current 500 VAC #22-#28 AWG #23 3 4 6 7 10 13 19 26 37 55 85 130 Size #20HD Contacts 7.5 Amp Max. Current 750 VAC #20-#24 AWG Size #16 Contacts 13 Amp Max. Current
|
Original
|
PDF
|
|
AWG 26 copper wire
Abstract: 1003B-10P10C
Text: Modular Plugs, EMC Shielded 1003B-8P8C For 24 & 26 AWG wire 1003B-10P10C (For 24 & 26 AWG wire) 1004B-8P8C (For 28 AWG wire) ELECTRICAL: • Current rating: 2 AMP maximum • Contact resistance: 20 milliohms maximum • Insulation resistance: 10 Megohms minimum
|
Original
|
PDF
|
1003B-8P8C
1003B-10P10C
1004B-8P8C
1000VAC
UL94V-0
P1003B-10P10C
AWG 26 copper wire
1003B-10P10C
|
idc connector 10 pin mta 156
Abstract: transistor n y amp mta 100 3.96 2.54 CONNECTOR EP 1408 MTA-156 16 position idc connector 3.96 Card Edge Connectors idc connector 10 pin MTA 156
Text: MTA, CST-100 II, SL-156 and AMP Economy Power EP Connectors Page_Head .156 [3.96] Centerline (Continued) MTA-156 IDC Connectors and Headers Product Facts Connectors and headers for 2 through 24 positions; wire sizes of 18, 20, 22, 24 and 26 AWG [0 .9– 0.12 mm2]
|
Original
|
PDF
|
CST-100
SL-156
MTA-156
UL94V-0,
idc connector 10 pin mta 156
transistor n y
amp mta 100
3.96 2.54 CONNECTOR
EP 1408
16 position idc connector
3.96 Card Edge Connectors
idc connector 10 pin
MTA 156
|
108-1051
Abstract: 82056 KPH 141 CST-100 LR7189 MTA-156 MTA 170 85 03 6414 tube EP 1408 amp tyco applicator
Text: MTA, CST-100 II, SL-156 and AMP Economy Power EP Connectors Page_Head .156 [3.96] Centerline (Continued) MTA-156 IDC Connectors and Headers Product Facts Connectors and headers for 2 through 24 positions; wire sizes of 18, 20, 22, 24 and 26 AWG [0 .9– 0.12 mm2]
|
Original
|
PDF
|
CST-100
SL-156
MTA-156
UL94V-0,
108-1051
82056
KPH 141
LR7189
MTA 170 85 03
6414 tube
EP 1408
amp tyco applicator
|
108-1051 product specification
Abstract: No abstract text available
Text: MTA, CST-100 II, SL-156 and AMP Economy Power EP Connectors .156 [3.96] Centerline MTA-156 IDC Connectors and Headers Product Facts Connectors and headers for 2 through 24 positions; wire sizes of 18, 20, 22, 24 and 26 AWG [0 .9– 0.12 mm2] • Connectors and headers,
|
Original
|
PDF
|
CST-100
SL-156
MTA-156
108-1051 product specification
|
MIL-STD-1560 Combo Contact Arrangements
Abstract: No abstract text available
Text: SERIES 23 MIL-STD-1560 combo contact arrangements Reference information Combo Contact Arrangements Number of Contacts #16 #12 1 4 2 2 1 2 8 12 12 23 20 Contact Size Size #20 Contacts 7.5 Amp Max. Current #20-#24 AWG Size #16 Contacts 13 Amp Max. Current #16-#20 AWG
|
Original
|
PDF
|
MIL-STD-1560
MIL-STD-1560 Combo Contact Arrangements
|
Untitled
Abstract: No abstract text available
Text: Soft Shell Pin and Socket Connectors AMP AMP-DUAC Connectors Continued Plug Housings L 4.00 1.6 2-24 Position Housings Accept male contacts. [.098] 10.0 5.6 [.394] [.220] 9.6 Material 2.5 [.157] [.063] M [.38] Recommended Cutout for 2.00 [.079] Max. Thick Panel
|
Original
|
PDF
|
|
ME50151V3
Abstract: ME50152V1 ME50151V1-000U-A99 ME50151V2-000U-A99
Text: 50x50x15 mm 12.9~18.6 CFM P/N Bearing VAPO ME50151V1-000U-A99 ME50151V2-000U-A99 ME50151V3-000U-A99 ME50152V1-000U-A99 ME50152V2-000U-A99 Rating Voltage VDC 12 12 12 24 24 Power Current Power Consumption Speed (AMP) (mA) (WATTS) 1.74 1.50 0.78 2.28 1.92
|
Original
|
PDF
|
50x50x15
ME50151V1-000U-A99
ME50151V2-000U-A99
ME50151V3-000U-A99
ME50152V1-000U-A99
ME50152V2-000U-A99
ME50151V3
ME50152V1
ME50151V1-000U-A99
ME50151V2-000U-A99
|
KT 508
Abstract: HYPERTAC PIN HYPERTAC CONTACT PIN Hypertac connector
Text: KT SERIES 8 AMP POWER PIN & SOCKET P.C. BOARD CONNECTORS 24 & 32 CONTACTS 8 amp rating each contact Very low mating forces Two row on .100” 2.54mm centers Fixed contacts on both plug and receptacle halves Mounting accessories available Æ.040” (1.02mm) contacts
|
Original
|
PDF
|
1--888--HYPERTAC
KT 508
HYPERTAC PIN
HYPERTAC CONTACT PIN
Hypertac connector
|
CMF-300
Abstract: S2424 FCPS-24RB D-110 FCPS-2404 relay module 24 volts 12 volts, 7 ah battery charging circuit DF-52202 24 volt 300 AH bat-1270
Text: DF-52202 • D-110 July 13, 2004 FCPS-2404 24 Volt, 4 Amp NAC Power Expander www.firelite.com Section: Power Supplies/Accessories GENERAL The Fire•Lite FCPS-2404 is a compact, cost-effective, NAC power expander. Its filtered 24 VDC output can provide up
|
Original
|
PDF
|
DF-52202
D-110
FCPS-2404
FCPS-2404
141-01-E
S2424
2404app
CMF-300
S2424
FCPS-24RB
D-110
relay module 24 volts
12 volts, 7 ah battery charging circuit
DF-52202
24 volt 300 AH
bat-1270
|
block diagram for fire alarm system
Abstract: A77-716B block fire alarm system block diagram FCPS-24S8 FCPS-24S6 DN-6927 DN-6933 fire alarm system block diagram DN-1109 charger 24volt
Text: July 20, 2004 DN-6927 • E-30 FCPS-24S6 and FCPS-24S8 6-Amp and 8-Amp 24-Volt Remote Power Supplies Section: Power Supplies GENERAL The FCPS-24S6 6-amp and FCPS-24S8 (8-amp) are compact, cost-effective remote power supplies with battery charger. The FCPS-24S6/-24S8 may be connected to any 12- or 24volt Fire Alarm Control Panel (FACP) or may be used as a
|
Original
|
PDF
|
DN-6927
FCPS-24S6
FCPS-24S8
24-Volt
FCPS-24S6
FCPS-24S6/-24S8
24volt
FCPS-24S6/-24S8
block diagram for fire alarm system
A77-716B
block fire alarm system block diagram
FCPS-24S8
DN-6927
DN-6933
fire alarm system block diagram
DN-1109
charger 24volt
|
|
Untitled
Abstract: No abstract text available
Text: HPF24S6 and HPF24S8 Description Power Supplies with Battery Chargers The HPF24S6 and HPF24S8 are compact, cost-effective, 6 amp. or 8 amp. remote power supplies with integral battery chargers. These adaptable power supplies may be connected to any 12 or 24 volt Fire Alarm Control Panel
|
Original
|
PDF
|
HPF24S6
HPF24S8
HPF24S8
HPF24S6:
HPF24S8:
CS-60062
|
Sh124
Abstract: BB624 BB724 amp cat 5 cable T1318 LH-324 CH824 CH924 LH124 MS224
Text: Industrial Connectors Series B 16 AMP 24 position + ground Screw connection: 18/14 AWG; 16 AMP, 600V Technical Information: see page T1317/T1318. Connector Inserts Hoods 13 1 1 13 14 2 2 14 15 3 3 15 16 4 4 16 17 5 5 17 18 6 6 18 19 7 7 19 20 8 8 20 21 9
|
Original
|
PDF
|
T1317/T1318.
PB124
PB324
PB224
PB424
BB024
BB124
BB624
BB724
BB224
Sh124
BB624
BB724
amp cat 5 cable
T1318
LH-324
CH824
CH924
LH124
MS224
|
CMTB-MC101-508-XX-GN
Abstract: 2000M AC300V MC101
Text: 1 2 3 4 5 6 7 SPECIFICATIONS Current Rating: Wire Range: Wire Strip Length: Screw Torque: Contact Material: A Insulation Material: B Insulation Resistance: Cage Clamp: Screw: Withstanding: Operating Temperature: C 16 Amp AC300V 12 ~ 24 AWG 4mm ~ 5mm 7.0 lb-inch
|
Original
|
PDF
|
AC300V
UL94V-0
2000M
MC101
CMTB-MC101-508-XX-GN
CMTB-MC101-508-XX-GN
AC300V
MC101
|
Untitled
Abstract: No abstract text available
Text: Modular Plugs EMC Shielded ELECTRO NICS,IN C . 1003B-8P8C For 24 & 26 AWG wire 1003B-10P10C (For 24 & 26 AWG wire) 1004B-8P8C (For 28 AWG wire) ELECTRICAL: • • • • Current rating: 2 AMP maximum Contact resistance: 20 milliohms maximum Insulation resistance: 10 Megohms minimum
|
OCR Scan
|
PDF
|
1003B-8P8C
1003B-10P10C
1004B-8P8C
1000VAC
UL94V-0
|
camshaft
Abstract: assembly instruction 9006 211914-1 66750-3 52491
Text: AM R IS 7703 AMP* CR SERIES ZERO-ENTRY-FORCE 156-POSITION CONNECTOR AMP INCORPORATED HARRISBURG, PA 17105 CUSTOMER HOTLINE 1 800 722-1111 IDC MODULE CONTACTS LOCKING FOR RIBBON LATCH CABLE Cover Included CAM LOCKING EDGE RELEASED 5-24-91 CAMSHAFT HANDLE'S^
|
OCR Scan
|
PDF
|
156-POSITION
156-POSN
camshaft
assembly instruction 9006
211914-1
66750-3
52491
|
Untitled
Abstract: No abstract text available
Text: 4 THIS DRAWING C 3 15 U N P U B L IS H E D . C O P Y R IG H T RELEASED 19 BY WIRING pi AMP IN COR PO RA TE D. ALL PUBLICATION R IG H T S ,19 R ES ER V ED . DIAGRAM WIRE COLOR A WG 1 RED 24 2 WH I T E 28 3 GREEN 28 4 BLACK 24 SHELL 5HI ELD — D FOR C A AMP
|
OCR Scan
|
PDF
|
27JUN96
p45876
45876/edm
0B20-0515-99
S/6/98
|
Untitled
Abstract: No abstract text available
Text: 2 WORKSTATION OUTLETS AMP Com m unications O utlet Twisted Pair Cables Pages 24, 25 Single Port Installation Kits Page 67, 81 Attachment Cable Pages 127-133 Mixed Media Outlets Page 35 Flush Mount / HOW TO ORDER AN AMP COMMUNICATIONS OUTLET SYSTEM • Choose the appropriate installation kit to meet your
|
OCR Scan
|
PDF
|
110-style
556805-11to
|
Untitled
Abstract: No abstract text available
Text: .250" 6.35mm Power Connector This unique general purpose wire to wire connector features insulation displacement termination in a hermaphroditic housing. This high current (12 AMP) connector, accepts a wire range of #16 thru #24 AWG, and can be adapted to most free-hanging
|
OCR Scan
|
PDF
|
2300-XXX-2XX
2300-001-2XX
|
6297
Abstract: No abstract text available
Text: 7 UNPUBLI 5HED COPYRIGHT 443118-1 D 19 RELEASED BY AMP ALL LOC 19 INTERNATIONAL RI GHTS DI ST R EV I 5 I 0 N 5 50 RESERVED. INSULATION ZONE LTR D E SCR I F T ION REV PER 0 G 3 D - 0 2 5 7 - 0 1 1 RED #24 AWG TEFLON . 0 5 0 [1 . 3] 2 ORANGE #24 AWG TEFLON . 0 5 0 [1 . 3]
|
OCR Scan
|
PDF
|
13-JUN-01
/home/ampl6412/edrnmod
6297
|
instruction sheet 408-7424
Abstract: 408-7497 408-7424 RS1019 RS-1019-5LP 90202-4 crimp 408-7424 AMP crimper Dies
Text: Instruction Sheet Hand Crimping Tool 90202-4 408-4574 24 n o v 99 Rev o PROPER USE GUIDELINES Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. AMP hand tools are intended for occasional use and low volume applications. AMP offers a wide selection of powered application equipment for extended-use, production operations.
|
OCR Scan
|
PDF
|
|