ALTERNATE KEY POSITIONS Search Results
ALTERNATE KEY POSITIONS Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
D1U54T-M-2500-12-HB4C | Murata Manufacturing Co Ltd | 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR | |||
D1U74T-W-1600-12-HB4AC | Murata Manufacturing Co Ltd | AC/DC 1600W, Titanium Efficiency, 74 MM , 12V, 12VSB, Inlet C20, Airflow Back to Front, RoHs | |||
PQU650-12P | Murata Manufacturing Co Ltd | AC/DC 650W, 6”X4” U-CHANNEL, 12V O/P | |||
LBEE5XV2BZ-883 | Murata Manufacturing Co Ltd | Shielded Small Wi-Fi® 11a/b/g/n/ac/ax 2x2 MIMO + Bluetooth® 5.2 Module - CCATS N/A(self classification) | |||
LBEE5ZZ2XS-846 | Murata Manufacturing Co Ltd | Shielded Small Wi-Fi® 11a/b/g/n/ac/ax 2x2 MIMO + Bluetooth® 5.3 Module - CCATS N/A(self classification) |
ALTERNATE KEY POSITIONS Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
y 803Contextual Info: Series 803 “Mighty Mouse” Bayonet Connectors Normal and Alternate Key Positions Series 803 Links Series 803 Series 803 Bayonet Connectors are available in four keying positions: N — Normal X — Alternate Key #1 Y — Alternate Key #2 Z — Alternate Key #3 |
Original |
818-te y 803 | |
mighty mouseContextual Info: Series 80 Mighty Mouse Series 80 “Mighty Mouse” Filter Connector Normal and Alternate Key Positions and Panel Cut-Out Dimensions A — Normal Keying B — Alternate #1 C — Alternate #2 Plug Key Positions Receptacle Key Positions A° B° |
Original |
||
Normal and Alternate Key Positions
Abstract: Filter Connectors
|
Original |
||
alternate key positionsContextual Info: MIL-DTL-5015 Type MIL-DTL-5015 Type Hermetic Power and Signal Connectors Alternate Key Positions Alternate Key Positions Alternate Key Positions Dash Number W° X° Y° Z° Dash Number W° X° Y° Z° 8S-1 – – – – 20-22 80 110 250 280 10S-2 – – |
Original |
MIL-DTL-5015 MIL-DTL-5015 10S-2 10SL-3 10SL-4 12S-3 12S-4 14S-1 alternate key positions | |
14S-5
Abstract: 14S-7 14S-6
|
Original |
MIL-DTL-5015 10S-2 10SL-3 10SL-4 12S-3 12S-4 14S-1 14S-2 14S-5 14S-7 14S-6 | |
Normal and Alternate Key PositionsContextual Info: Mighty Mouse Series 80 Mighty Mouse Filter Connector Normal and Alternate Key Positions SERIES Plug Key Positions Receptacle Keyway Positions 801 804 805 C A° A° B° B° Series 80 Mighty Mouse Alternate Key Positions Key Notes A° Position B° A Normal 150° |
Original |
||
Contextual Info: Amphenol Aerospace MIL-DTL-83723, Series III, Matrix Insert Availability and Identification, Alternate Keying Positions, Alternate Rotations INSERT ARRANGEMENTS ALTERNATE KEYING POSITIONS Rotation of key/keyway of shell Contact Size To avoid cross-plugging problems in |
Original |
MIL-DTL-83723, | |
0 280 130 122
Abstract: 32A48 32-B22 40A21 32-A48 stegmann+AG+110 GMPM2-B112RCBSXU.110
|
OCR Scan |
14S-2 14S-5 14S-6 14S-7 14S-9 16S-1 16S-4 16S-5 16S-8 6A-10 0 280 130 122 32A48 32-B22 40A21 32-A48 stegmann+AG+110 GMPM2-B112RCBSXU.110 | |
Contextual Info: Miniature Cylindrical MIL-C-83723, Series III alternate positioning ALTERNATE KEYING POSITIONS Rotation of key/keyway of shell ALTERNATE CLOCKING POSITIONS (Rotation of insert) To avoid cross-plugging problems in applications requiring the use of more than one connector of the same size and arrangement, alternate keying positions are available as indicated in the |
Original |
MIL-C-83723, alter15 MIL-STD-1554. | |
Contextual Info: Series 801 “Mighty Mouse” Double-Start Receptacle Connectors Normal and Alternate Key Positions Series 801 Links Series 801 Double-Start Plugs and Receptacles feature a Master Key and two Secondary Keys for positive mating. Four key positions are available: |
Original |
||
VDE0660
Abstract: Airpax 5003 Z151 288-1315-ND Airpax Z15-20 Z1533-ND A22S-3M-20 Airpax motor A22S-2M
|
Original |
110VAC 24VDC 288-1339-ND 288-1329-ND 288-1330-ND 288-1340-ND 288-1341-ND 288-1342-ND 288-1331-ND 288-1337-ND VDE0660 Airpax 5003 Z151 288-1315-ND Airpax Z15-20 Z1533-ND A22S-3M-20 Airpax motor A22S-2M | |
Alternate Keying PositionsContextual Info: SERIES 23 Filter connectors Alternate keying positions MIL-DTL-38999 Series III type PLUG RECEPTACLE MASTER KEY MASTER KEYWAY W° W° Z° Z° X° X° Y° Y° NOTE: ALL MINOR KEYS AND KEYWAYS ARE ROTATED TO PROVIDE POLARIZATION WHILE MASTER KEY AND KEYWAY REMAIN FIXED. |
Original |
MIL-DTL-38999 Alternate Keying Positions | |
patt 602
Abstract: SAV-CON
|
Original |
||
m2-v hydraulic fluid
Abstract: AE833 MS3186 m85049 instructions AE83384
|
Original |
MIL-DTL-83723 MIL-DTL-26500 AE833 MIL-STD-1554 m2-v hydraulic fluid MS3186 m85049 instructions AE83384 | |
|
|||
Contextual Info: MIL-DTL-83723 Series III Features and Application Bayonet and Threaded Coupling Features and Application Shell Polarization – Alternate key/keyway positions prevent cross mating of adjacent connectors having same insert arrangement. MIL-DTL-83723 Series III family offers connectors with |
Original |
MIL-DTL-83723 MIL-DTL-26500 | |
multimod
Abstract: harness assembly
|
Original |
||
Contextual Info: CD00272690 Rev 1.1 IN APPROVAL PAGE A ft 15 Watt regulated Triac-dimmable LED driver for the North American 115 V market -D ra Technical Literature Alternate Identifier(s) Key process 17474 Product Development Dr ISO Definition aft CUSTOM ATTRIBUTES ft - |
Original |
CD00272690 STEVAL-ILL016V2, | |
B4750Contextual Info: m o l e x " Circular Industriar Connectors Spirit In field insert keying is achieved by alignment of a molded key Front Shell Assembly letter on the rear of the insert with an indicator on the rear of the shell during assembly. Eight alternate keying positions are |
OCR Scan |
||
Contextual Info: MIL-C-26482 SERIES II POLARIZING POSITIONS t The normal position N has the insert centerline coinciding with the centerline of the master key (or keyway) of the shell. The alternate clocking positions (W,X,Y, and Z) are accom plished by rotating the pin insert clockwise. The socket insert |
OCR Scan |
MIL-C-26482 AE770* AE772* AE774* MS3470* MS3471* MS3472* MS3474* AE775* | |
Contextual Info: /T V m o l e x Circular Industrial Connectors Spirit™ In field insert keying is achieved by alignment of a molded key letter on the rear of the insert with an indicator on the rear of Front Shell Assembly the shell during assembly. Eight alternate keying positions are |
OCR Scan |
606I-T6 36203M03 36103M03 | |
Mighty Mouse to AlphaLink Flex JumpersContextual Info: mighty mouse to alphalink flex jumpers Contact arrangements • dimensions • alternate key positions Mighty Mouse to AlphaLink Flex Jumpers Glenair Series 801 double-start ACME thread and Series 804 quick-disconnect Mighty Mouse receptacles in 8 contact arrangements terminated with rugged polyimide-based flex to highperformance AlphaLink SL board level connectors. |
Original |
||
Contextual Info: MIL-C-83723 III AERO ELECTRIC MIL-C-83723 SERIES III POLARIZING LOCKSMITH KEYED POSITIONS MACHINED IN THE SHELL In the normal position (N) the centerline of the insert is the same as the master key or keyway of the shell. In the alternate positions (6,7,8,9, and Y) the minor keys, or |
OCR Scan |
MIL-C-83723 POSITI20Â | |
Contextual Info: c=iP MIL-C-26500 1 = ^ 1 / — r AERO ELECTRIC MIL-C-26500 POLARIZING LOCKSMITH KEYED POSITIONS (MACHINED IN THE SHELL In the normal position (N) the centerline of the insert is the same as the master key or keyway of the shell. In the alternate positions (6,7,8,9, and Y) the minor keys, or |
OCR Scan |
MIL-C-26500 MIL-C-26500 | |
GC443Contextual Info: Sav-Con connector savers MIL-DTL-38999 Series I GC443 In-Line Bayonet Coupling Gender Changer HOW TO ORDER Sample Part Number GC443 Series GC443 Style A - In-line Finish See Table I Shell Size See Table II Alternate Key Position A, B, C, D, Omit for Normal; See Table III |
Original |
MIL-DTL-38999 GC443 GC443 MIL-C-38999 |