Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ALARM DISTANCE Search Results

    ALARM DISTANCE Result Highlights (4)

    Part ECAD Model Manufacturer Description Download Buy
    G17DD1504231SHR
    Amphenol Communications Solutions Dsub Slim RighAngle Dip, High Density 15 Position Receptacle VGA, Sunk 3.8mm, 10u\\ Au, Footprint 1.2mm, 2 Rows, Pitch 1.5mm, Post distance 3.2mm, PCB hole distance 2.4mm, Tail 2.0mm, Tape and Reel with Cap, Blue 661C, PIP, Halogon Free PDF
    G17DC15023313HR
    Amphenol Communications Solutions Dsub Slim R/A Dip, High Density 15 Position Receptacle VGA, Sunk 4.27mm, 15u\\ Au, Footprint 1.6mm, 2 Rows, Pitch 1.0mm, Post distance 1.4mm, PCB hole distance 2.3mm, Tail 3.05mm, Tape and Reel with Cap, Blue 661C, PIP, Halogon Free PDF
    G17DD1504231RHR
    Amphenol Communications Solutions Dsub Slim RighAngle Dip, High Density 15 Position Receptacle VGA, Sunk 3.8mm, 10u\\ Au, Footprint 1.2mm, 2 Rows, Pitch 1.5mm, Post distance 3.2mm, PCB hole distance 2.4mm, Tail 2.65mm, Tape and Reel with Cap, Blue 661C, PIP, Halogon Free PDF
    G17DD1504231GHR
    Amphenol Communications Solutions Dsub Slim RighAngle Dip, High Density 15 Position Receptacle VGA, Sunk 3.8mm, 10u\\ Au, Footprint 1.2mm, 2 Rows, Pitch 1.5mm, Post distance 3.2mm, PCB hole distance 2.4mm, Tail 3.0mm, Tape and Reel with Cap, Blue 661C, PIP, Halogon Free PDF

    ALARM DISTANCE Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: FireVac IV Emergency Voice Evacuation System Description The FireVac®IV is a fully automatic combination fire alarm and emergency voice evacuation system. When it is combined with an FCI fire alarm control, it provides automatic and manual alarm signaling per the National Fire Alarm


    Original
    FVIV-X70) FVIV-50-ZS, FVIV-X70, FVIV-B450, PDF

    shock sensor

    Abstract: shock sensor 801 alcohol sensor Ultrasonic Transducer for gas meter distance measurement ultrasonic sensor resistive Humidity Sensor VS-801 UTEC4012 VS-102 ultrasonic sensor for distance measurement
    Contextual Info: Item Picture ft* Dimensions Name Model shock sensor VS-102 Alarm, Electric Lock & other shock detector shock sensor VS-801 Alarm, Electric Lock & other shock detector shock sensor VS-801 S Alarm, Electric Lock & other shock detector shock sensor VS-801 P Alarm, Electric Lock


    OCR Scan
    VS-102 VS-801 VS-603 TS-TR4010 TS-TR4012 TS-TR4016 UTEC4010 UTEC4012 shock sensor shock sensor 801 alcohol sensor Ultrasonic Transducer for gas meter distance measurement ultrasonic sensor resistive Humidity Sensor ultrasonic sensor for distance measurement PDF

    fire alarm design

    Abstract: circuit diagram for fire alarm system fire alarm 74HC132 AN047 HC132 PLS168 pls168a detector fire circuit of fire alarm system
    Contextual Info: Philips Semiconductors Programmable Logic Products Application Note Alarm Controller AN047 A Programmable Alarm System – PLS168 A basic alarm controller can be considered as a black box with several inputs and several outputs Figure 1 . Some inputs are


    Original
    AN047 PLS168 fire alarm design circuit diagram for fire alarm system fire alarm 74HC132 AN047 HC132 PLS168 pls168a detector fire circuit of fire alarm system PDF

    conclusion of the light alarm project

    Abstract: Light-sensitive Alarm Project burglar alarm system abstract schematic photoelectric sensor photoelectric burglar alarm small burglar alarm project Keyence PZ-G61B keyence Keyence OP-84219 keyence reflector
    Contextual Info: Maxim > App Notes > MICROCONTROLLERS Keywords: MAXQ3210, MAXQ3212, alarm, photoelectric, sensor, light-beam, light beam, alarm, RISC, microcontroller, uC, retroreflective, diffuse, through-beam, opposed Feb 26, 2008 APPLICATION NOTE 4153 Using the MAXQ3210 in a Light-Beam Alarm System


    Original
    MAXQ3210, MAXQ3212, MAXQ3210 com/an4153 MAXQ3210: MAXQ3212: AN4153, APP4153, Appnote4153, conclusion of the light alarm project Light-sensitive Alarm Project burglar alarm system abstract schematic photoelectric sensor photoelectric burglar alarm small burglar alarm project Keyence PZ-G61B keyence Keyence OP-84219 keyence reflector PDF

    AN3818-1

    Contextual Info: p p jp jl G £ C P L E S S E Y AN3818-1.2 DA5813 Application Note MICROWAVE CAR ALARM SENSOR GENERAL DESCRIPTION The DA5813 microwave car alarm sensor is designed to be compatible with the majority of alarm systems currently in production that have a volumetric sensor input (usually for an


    OCR Scan
    AN3818-1 DA5813 DA5813 PDF

    panasonic kt4

    Abstract: KT4H Matsushita Electric Works kt4 nais relay 24V r relay diagram i phase heater with temperature controller AKT4810 PLC nais diagram 3 phase heater nais relay 24V high speed NAIS RELAY PANASONIC
    Contextual Info: KT4H Temperature Controller KT4H Temperature Controller PRODUCT TYPES DIMENSIONS 1. KT4H Series Base model AKT4H Power supply Rubber gasket Sensor input Control output Alarm output Heating/ Heater Communications cooling control burnout alarm function 1 2 1


    Original
    ARCT1B257E-2 ARCT1B257E-2 200603-1YT panasonic kt4 KT4H Matsushita Electric Works kt4 nais relay 24V r relay diagram i phase heater with temperature controller AKT4810 PLC nais diagram 3 phase heater nais relay 24V high speed NAIS RELAY PANASONIC PDF

    2N3904

    Abstract: 2N3906 ADM1032 ADT7481 ADT7481ARMZ ADT7481ARMZ-R7 ADT7481ARMZ-REEL
    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3−channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the


    Original
    ADT7481 ADT7481 ADM1032, ADT7481/D 2N3904 2N3906 ADM1032 ADT7481ARMZ ADT7481ARMZ-R7 ADT7481ARMZ-REEL PDF

    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3−channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the


    Original
    ADT7481 ADM1032, ADT7481/D PDF

    ANN-80

    Abstract: GFANN-80
    Contextual Info: GFANN-80 80-Character LCD Description The GFANN-80 annunciator is a compact, backlit 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel FACP display. It provides system Status indicators for AC power, Alarm, Trouble, Supervisory, and


    Original
    GFANN-80 80-Character GFANN-80 GFANN-80-W) GFANN-80-W ANN-80 PDF

    2N3904

    Abstract: 2N3906 ADM1032 ADT7481 ADT7481ARMZ ADT7481ARMZ-R7 ADT7481ARMZ-REEL
    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3−channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the


    Original
    ADT7481 ADT7481 ADM1032, ADT7481/D 2N3904 2N3906 ADM1032 ADT7481ARMZ ADT7481ARMZ-R7 ADT7481ARMZ-REEL PDF

    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Over Temperature Alarm The ADT7481 is a 3−channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the


    Original
    ADT7481 ADM1032, ADT7481/D PDF

    Contextual Info: Type: E-FLC3 Floatless Level Controller with Alarm Output q q q q q q q q Designed to monitor the level of a liquid within a tank or container 3 levels of monitoring - Low, High and Alarm levels Fixed Operate and Release Resistance Up to 1km distance between controller and probes


    Original
    160mS E-FLC3-A2002-11-12 PDF

    siren with light

    Abstract: fire alarm file fire alarm fire alarm system fire monitor L208 heidelberg circuit
    Contextual Info: 2CDC541017D0201.qxd 11.03.2002 20:47 Uhr Seite 1 Technical Data Security Technology Combination Signalling Device SSF SK 105B01 Brief description: Signalgeber SSF/GB The signalling devices SSF/G and SSF/GB are used for external and local alarm signals by intruder alarm systems.


    Original
    2CDC541017D0201 105B01 D-69006 D-69123 R0001 EAN40 D0201 siren with light fire alarm file fire alarm fire alarm system fire monitor L208 heidelberg circuit PDF

    alarm distance

    Abstract: sensor Baumer Teac* baumer light dark sensor circuit 18P6460 pnp diode 103068
    Contextual Info: Diffuse sensor Series 18 Diffuse sensor with Teach-in Tw 430 mm Tw 430 mm cable connector PNP light operate dark operate light/dark operate alarm FZAM 18P6460 FZAM 18P6460/S14 NPN light operate dark operate light/dark operate alarm FZAM 18N6460 FZAM 18N6460/S14


    Original
    18P6460 18P6460/S14 18N6460 18N6460/S14 33AP2 34AP2 alarm distance sensor Baumer Teac* baumer light dark sensor circuit 18P6460 pnp diode 103068 PDF

    finder delay relay

    Contextual Info: AE20 Dimensions ● Operation Unit ANE2010 / ANE2020 / ANE2030 ANE11 000000 Matsushita Electric works, Ltd. Made in Japan IN-COM Black READY White IN-COM Black READY TRIGGER WH&YE ALARM Red TRIGGER WH&YE ALARM Gray TEACH WH&BN OUT1 Gray TEACH Orange TYPE1


    Original
    ANE2010 ANE2020 ANE2030 ANE11 ARCT1B250E-1 ARCT1B250E-1 200606-5YT finder delay relay PDF

    WATER LEVEL DETECTOR WITh ALARM

    Abstract: water level indicator using led and buzzer 61F-GPN-V50 omron liquid level sensor metal detector sensor 61GPN-V50 PF113A-E PL11 61f-gp-n leak detector sensor
    Contextual Info: Water Leak Alarm/Detector 61F-WLA/-GPN-V50 • Eliminate Problems Caused from Water Leakage • 0 to 50 k: variable operating resistance to detect virtually any liquid. • Two types available: Water Leak Alarm 61F-WLA and plug-in Water Leak Detector (61F-GPN-V50).


    Original
    61F-WLA/-GPN-V50 61F-WLA) 61F-GPN-V50) 61F-WLA 61F-GPN-V50 WATER LEVEL DETECTOR WITh ALARM water level indicator using led and buzzer 61F-GPN-V50 omron liquid level sensor metal detector sensor 61GPN-V50 PF113A-E PL11 61f-gp-n leak detector sensor PDF

    BB-400A

    Contextual Info: B.D.I. BU RST DI SC IN D ICATO R The B.D.I. Burst Disc Indicator Alarm System is designed for use with Continental Disc ® rupture discs. The B.D.I. Alarm System signals the system operator when a rupture disc has burst to relieve an overpressure or vacuum condition.


    Original
    423/P/11, TCH1284DS BB-400A PDF

    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3-channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the temperature of two remote thermal diodes. These thermal diodes can


    Original
    ADT7481 ADT7481 ADM1032, ADT7481/D PDF

    Contextual Info: NetSOLO Broadband Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System Description The NetSOLO® Broadband is a revolutionary advance in fire detection and emergency voice evacuation system design. NetSOLO® Broadband employs the proven technology of the 7100 Series fire alarm control panel and


    Original
    PDF

    Contextual Info: 600 Series SmartLink Peer-to-Peer Fire Alarm Network Description The Gamewell-FCI SmartLink™ Network provides a peerto-peer interface that allows up to 250 Gamewell-FCI, 600 Series Fire Alarm Control Panels FACPs to be linked in a network. Each FACP (node) maintains its own program


    Original
    CS-2073 PDF

    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3-channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the temperature of two remote thermal diodes. These thermal diodes can


    Original
    ADT7481 ADM1032, ADT7481/D PDF

    adt7481a

    Contextual Info: ADT7481 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7481 is a 3-channel digital thermometer and under/ over temperature alarm, intended for use in PCs and thermal management systems. It can measure its own ambient temperature or the temperature of two remote thermal diodes. These thermal diodes can


    Original
    ADT7481 ADM1032, ADT7481/D adt7481a PDF

    sensor optico

    Abstract: H160 RL28-55 Kunststoffstecker C1102
    Contextual Info: Adressen/Addresses Electrical connection /47 Option: /82b /47 Option: 1 +UB 1 +UB 2 Q 2 Q 3 0V 3 0V 4 Q 4 Q Reflection light beam switch with polarisation filter /82b Deutschland: Great Britain: USA: France: España Alarm 5 Alarm I/O 5 Italia I/O Singapore


    Original
    PDF

    Contextual Info: ADT7482 Dual Channel Temperature Sensor and Overtemperature Alarm The ADT7482 is a three-channel digital thermometer and under/overtemperature alarm for PCs and thermal management systems. It can measure the temperature in two remote locations, such as in the remote thermal diode in a CPU or GPU, or using a discrete


    Original
    ADT7482 ADT7482 ADT7482/D PDF