AJT 300 Search Results
AJT 300 Datasheets (1)
Ferraz Shawmut
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| AJT300 | Ferraz Shawmut | Fuse 300A 600V CURRENT LIMITING | Original | 351.5KB | 3 |
AJT 300 Price and Stock
Select Manufacturer
Mersen Electrical Power AJT300EIFuse: fuse; 300A; 600VAC; time-lag; AJT; brass |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
AJT300EI | 1 |
|
Get Quote | |||||||
Mersen Electrical Power AJT300Fuse: fuse; 300A; 600VAC; time-lag; AJT; brass |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
AJT300 | 1 |
|
Get Quote | |||||||
SEI Stackpole Electronics Inc WRC2AJT300RResistor, 300 ohm, ? 5%, 2 W, Axial Leaded, 24.49 V, Wirewound, Flame Proof - Tape and Reel (Alt: WRC2AJT300R) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
WRC2AJT300R | Tape & Reel | 22 Weeks | 2,000 |
|
Buy Now | |||||
SEI Stackpole Electronics Inc WRC4AJT300RResistor, 300 ohm, ? 5%, 4 W, Axial Leaded, 34.64 V, Wirewound, Flame Proof - Tape and Reel (Alt: WRC4AJT300R) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
WRC4AJT300R | Tape & Reel | 22 Weeks | 2,000 |
|
Buy Now | |||||
SEI Stackpole Electronics Inc WRC3AJT300RResistor, 300 ohm, ? 5%, 3 W, Axial Leaded, 30 V, Wirewound, Flame Proof - Tape and Reel (Alt: WRC3AJT300R) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
WRC3AJT300R | Tape & Reel | 22 Weeks | 2,000 |
|
Buy Now | |||||
Documents mentioning AJT 300
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ajt fuse | SMARTSPOT INDICATOR AMP-TRAP 2000® AJT Time Delay/Class J SMARTSPOT® WITH Maximum circuit PROTECTION Amp-trap 2000® SmartSpot® AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type “2” (No Damage) |
Original | ||||
| ajt fuse | SMARTSPOT INDICATOR AMP-TRAP 2000® AJT TIME DELAY / CLASS J SMARTSPOT™ WITH MAXIMUM CIRCUIT PROTECTION Amp-trap 2000® SmartSpot™ AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type “2” (No Damage) |
Original | ||||
| General Purpose US US Fuses General Purpose Fuses | General Purpose US US Fuses General Purpose Fuses American Power Fuses AMP-TRAP 2000 AJT (Class J TD) ® SMARTSPOT® with Maximum circuit protection Amp-trap 2000® SmartSpot® AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line |
Original | ||||
| Product Guide Product Guide Amp-Trap 2000® Fuses | Product Guide Product Guide Amp-Trap 2000® Fuses AJT A2D & A6D A4BQ ATDR & ATQR Class J Time Delay 1 to 600A 600V AC, 200kA I.R. 300kA I.R. UL Witnessed 500V DC, 100kA I.R. Current Limiting UL Listed CSA Certified Smart Spot Indicator Motor, motor controller, control |
Original | ||||
| APPLICATION INFORMATION FUSE LET-THRU TABLES | APPLICATION INFORMATION FUSE LET-THRU TABLES (Continued) Apparent RMS Symmetrical Let-Thru Current Table 7 - Class J, AJT Fuses at 600 Volts AC, 15% Power Factor PROSPECTIVE SHORT CIRCUIT RMS. SYM AMPERES irms lp 5,000 10,000 15,000 20,000 25,000 30,000 35,000 |
Original | ||||
| Product Data Sheet 6J400AXB FBD Replace “X” with | Product Data Sheet 6J400AXB FBD Replace “X” with 1 or 3 for number of poles Class J Fuse Holder Bolt-Down Construction 400 Amps, 600 Volts AC Wire Range: (1) 350 kcmil - #6 AWG and (1) 600 kcmil - #2 AWG Holds fuse size 2 1/8” diameter X 7 1/8” Commonly used fuses in this holder: A4J, AJT, JKS, JLS, JTD, JTD_ID, LPJ |
Original | ||||
| 6j200axb | Product Data Sheet 6J200AXB FBD Replace “X” with 1 or 3 for number of poles Class J Fuse Holder Bolt-Down Construction 200 Amps, 600 Volts AC Wire Range: 350 kcmil - #6 AWG Holds fuse size 1 5/8” diameter X 5 3/4” Commonly used fuses in this holder: A4J, AJT, JKS, JLS, JTD, JTD_ID, LPJ |
Original | ||||
| Product Data Sheet 6J600AXB FBD Replace “X” with | Product Data Sheet 6J600AXB FBD Replace “X” with 1 or 3 for number of poles Class J Fuse Holder Bolt-Down Construction 600 Amps, 600 Volts AC Wire Range: (2) 500 kcmil - #4 AWG Holds fuse size 2 1/2” diameter X 3 3/4” Commonly used fuses in this holder: A4J, AJT, JKS, JLS, JTD, JTD_ID, LPJ |
Original | ||||
| 8 7 4 5 3 2 6 .500 .005 2.490 F 1 ITEM NO. QTY. | 8 7 4 5 3 2 6 .500 .005 2.490 F 1 ITEM NO. QTY. DESCRIPTION DRAWING # REF 1 1 B92HN-A353 10120 2 184 E_B-DHH 10011 .590 F 1.645 1.550 .005 2.400 .005 .050 .070 .050 .075 CARDSLOT .060 E .124 E .124 5.040 .370 1 A .300 INSERTION DEPTH .758 D D A 49 POSITION |
Original | ||||
| 8 7 4 5 3 2 6 1 ITEM NO. QTY. DESCRIPTION 1 1 | 8 7 4 5 3 2 6 1 ITEM NO. QTY. DESCRIPTION 1 1 B92CD-A351 2 184 EZB-DHM 2.490 63.25 DRAW ING # REF 10127 256 1.657 42.09 .590 14.99 F F .500 12.70 2.400 60.96 1.550 39.37 .080 2.03 CARDSLOT E .070 1.78 .050 1.27 .150 3.81 .150 3.81 .370 9.40 5.040 128.02 .300[7.62] |
Original | ||||
| ferraz shawmut | it’s your responsibility To learn more, visit the Arc Flash Info Center™ Ferraz Shawmut offers other ways to improve electrical safety. To learn more about our finger-safe devices, customizable circuit protection safety training, and inventory analysis and upgrade services, visit the Arc Flash Info Center |
Original | ||||
| Amp-Trap 2000® Your electrical system is your | Amp-Trap 2000® Your electrical system is your lifeline. A lifeline that can be cut by an arc flash can disintegrate. Conductors can vaporize. Bus bars can break. And components like switchgear, MCC buckets and motor starters can be destroyed, bringing your operation to a halt. |
Original | ||||
| Product Data CENTERLINE® Motor Control Centers | Product Data CENTERLINE® Motor Control Centers Power Fuses Application The information in this publication applies to the selection of 3-phase motor power fuses when used in 460V and 575V applications, as well as to the selection of power fuses in branch circuit or non-motor applications. |
Original | ||||
| us.ferrazshawmut.com Upgrade to A4BQ, 600V, CLASS | us.ferrazshawmut.com Upgrade to A4BQ, 600V, CLASS L CHART CL CLL A4BY CLU KLLU KLP-C WCL KLU A4BQ (amp) 600V NCL KRP-C KRPC-L (OVER 600A) LCL LCU Ampere Rating 100 - 800 801 - 1200 1201 - 1600 1601 - 2000 2001 - 2500 2501 - 3000 3001 - 4000 4001 - 5000 5001 - 6000 |
Original | ||||
|
|
||||||
| Tech Topics: Component Protection Note 2, Issue 1 | Tech Topics: Component Protection Note 2, Issue 1 Enhancing Short Circuit Safety with Type 2 Coordination for Motor Starters Michael J. Lang Field Engineering Manager Introduction As of April 26, 2006, suppliers of UL listed Industrial Control Panels (ICP) must clearly label |
Original | ||||
| Tech Topics: Arc Flash Note 2, Issue 1 Reducing | Tech Topics: Arc Flash Note 2, Issue 1 Reducing Arc Energies with Current Limiting Fuses Michael J. Lang Field Engineering Manager Why Use Current Limiting Fuses Current limiting fuses can reduce both the magnitude and duration of a fault current. A UL Listed, current limiting fuse must clear a short circuit current in less than one half cycle in its |
Original | ||||
| b92hn-a352 | 8 7 4 5 3 2 6 .592 15.04 2.490 63.25 .500 12.70 1 ITEM NO. QTY. DESCRIPTION 1 1 B92HN-A352 2 184 EZB-DHH 3 2 BOARD LOCK 1.650 41.91 DRAWING # REF 10133 10011 10131 F F 1.550 39.37 2.400 60.96 .150 3.81 E .050 1.27 .070 1.78 E .150 3.81 5.040 128.02 .370 9.40 |
Original | ||||
| ferraz shawmut | Ferraz Shawmut SCCR Quick Select Guide ITEM 1MSC 1SC 20300 - 22053R TYPE DESCRIPTION Form 101 Modular Semiconductor Fuse Blocks Form 101 Modular Semiconductor Fuse Blocks 250V Open Style Fuseholder for Class H, K and R Fuses H For use with Class H K For use with Class K |
Original | ||||
| 8 7 F A D G M N O P R S T V W X Y Z CONTACT | 8 7 F A D G M N O P R S T V W X Y Z CONTACT .000015" GOLD .00003" GOLD .00001" GOLD .00003" GOLD .00005" GOLD .00003" GOLD GOLD FLASH .00002" GOLD .00001" GOLD .0001" TIN/LEAD .00003" GOLD GOLD FLASH .00003" GOLD .00003" GOLD .00001" GOLD 4 5 6 PLATING SPECIFICATIONS |
Original | ||||
| cross reference | FUSE CROSS REFERENCES & UPGRADE Amp-Trap 2000® Family - For total system protection Class CC Fuses 3 AMPS & Above* Existing 511 CLASS RK1 250V Existing Upgrade 10KOTN ATDR (amp) Upgrade A2D (amp) R 50KOTN 512 A2KR 5AG AT-DE 6JX CH-G AGU CRN A6Y-2 CSN-R A6Y-2B |
Original | ||||
| gl6eg11t | GL6D ~1 IT Series LED Lamps GL6DU11 T Series f~~~~~.x) Cy’inder ‘ ■ Outline Dimensions ■ Model No. GL6LIR11T GL6EG11T P1 Red (Super-luminosity) GaA1.4s/GaALAs Yellow-green GaP Ype (IJnit: mm) L’olorle*s” trcins[]arellcy ■ Features 1. $5mm(T–l X) all resin mold |
Original | ||||