Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AIR MASS Search Results

    AIR MASS Result Highlights (4)

    Part ECAD Model Manufacturer Description Download Buy
    UE36C1620005D6A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 21.5mm high fin pin style heat sink, front to back air flow PDF
    UE36C1650005A3A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 6.5mm height fin pin style heat sink, front to back air flow PDF
    UE36-C26200-05C3A
    Amphenol Communications Solutions 1x2 QSFP-DD cage with SAN height fin pin style heat sink, side to side air flow PDF
    UE36C162000511A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 10.4mm height fin pin style heat sink, front to back air flow PDF

    Documents mentioning AIR MASS

    Document Partial File Text Tags Type PDF
    CONNECTEURS COMPOSITE Série 544 Groupe AIR LB
    CONNECTEURS COMPOSITE Série 544 Groupe AIR LB Series 544 PLASTIC CONNECTOR AIR LB Group Edition 12 / 99 SYSTÈMES DE CONNEXIONS ÉLECTRIQUES ET ÉLECTRONIQUES ELECTRIC AND ELECTRONIC CONNECTION SYSTEMS Amphenol Amphenol Air LB Direction des Ventes / Sales office
    Original PDF
    amphenol air lb
    CONNECTEURS SUB-D ETANCHES Amphenol Air LB SEALED SUB-D CONNECTORS Amphenol Air LB Edition 09 / 01 Amphenol Air LB SYSTÈMES DE CONNEXIONS ÉLECTRIQUES ET ÉLECTRONIQUES ELECTRIC AND ELECTRONIC CONNECTION SYSTEMS DESCRIPTION DESCRIPTION Les connecteurs subminiatures rectangulaires étanches, pour
    Original PDF
    kp22x
    Product Brief KP22x/Turbo MAP Integrated Pressure Sensor IC for Manifold Air Pressure Measurement Applications Application The manifold air pressure (Turbo MAP) is an important parameter to compute the air-fuel ratio provided to the engine for lower emission due to better combustion
    Original PDF
    18f2539
    AN861 Smart Air Handler using ProMPT™ and the PIC18F2539 Author: Jon Burroughs Microchip Technology Inc. INTRODUCTION In many heating, ventilation, and air conditioning (HVAC) applications, air handler motors are either off, or on at full speed. However, by adding variable speed
    Original PDF
    vent-captor
    C vent-captor vent-captor air flow monitors are solid state switch and monitoring devices for use in industrial air handling applications. vent-captor air flow monitors are self-contained switching devices without any mechanical moving parts, which convert flow conditions into electrical switching signals.
    Original PDF
    thermal mass
    Data Sheet 10/14-6.63-EN Thermal Mass Flowmeter Sensyflow FMT200-ECO2 for air, compact design Direct mass flow measurement of air - No additional pressure and temperature compensation required - Mass flow or standard volume flow measuring values Wide measuring range of 1:100
    Original PDF
    yj1540
    YJ1540 YJ1540-1 YJ1540-2 A . NATIONAL Page 1 of 9 6/91 Descriptions of Three Mechanical Variations YJ1540 is air cooled without thermoswitch YJ1540-1 is water cooled with thermoswitch YJ1540-2 is air cooled with thermoswitch CONTINUOUS-WAVE MAGNETRON Packaged, metal-ceramic, forced-air cooled, continuous-wave magnetron with integral r.f. cathode filter.
    OCR Scan PDF
    ul1430
    ■ Dimensions (unit : mm) Air Flow Direction 35±1 27.8±1 +30 300 0 ° ±1 45° (10) Lead Wire AWG24 UL1430 ∅150±1 ∅105±1 51.2±1 8.5±1 4-M4 Centrifugal Fan ■ Features ∅89 .4±1 ∅6 4± 0.3 Large air flow and high static pressure ・Maximum air flow : 3.83 m3/min (135 CFM)
    Original PDF
    air lb
    CO NNECTEUR S CO M PO SITE Série 544 Groupe AIR LB Serie s 544 PLASTIC CONNECTO R AIR LB Grou p Edition 12 / 99 SYSTÈM ES D E CO NNEXIO NS ÉLECTRIQUES ET ÉLECTRO NIQUES ELECTRIC A N D E LECTRO NIC CO NNECTIO N SYSTEM S Groupe Group AIR LB Siège Social
    Original PDF
    Precision Thermistor Thermistors Glass
    Precision Thermistor Thermistors Glass Encapsulated Thermistors 0.075 (1.91) Specifications: • Thermal Time Constant: 5 seconds (still air); 0.5 seconds (stirred liquid) • Dissipation Constant: 2mW/°C (still air) Resistance @ 25°C (Ω) 2500 5000 10000
    Original PDF
    flow sensor
    D6F D6F MEMS Flow Sensor High accuracy mass flow sensing ■ Small size ■ Fast response ■ Applicable to air, non-corrosive gas, LNG Ordering Information Model D6F-01A1-110 Case Gsa PPS Air* Aluminum LNG* (13A) Flow Range Notes 0-1L/min D6F-02A1-110 Integral orifice
    Original PDF
    PRECISION PRESSURE TRANSDUCERS FOR AIR DATA
    PRECISION PRESSURE TRANSDUCERS FOR AIR DATA MEASUREMENTS AN–104 Larry Bashaw and Peter Nussbaum This technical note briefly describes the fundamentals of utilizing pressure measurements for aircraft air data instrumentation, and the factors to be considered when
    Original PDF
    Remote control receiver Modules Photo Link
    Remote control receiver Modules Photo Link Modules (Surface mount type) zRecommended soldering conditions [Recommended mounting conditions] Hot air reflow condition Package surface temperature (°C) Temp.(°C) Hot air reflow (Heat) frequency is allowed 2-times or less
    Original PDF
    CEWfrMfTE MOTOR START PSC SINGLE PHASE MOTOR
    CEWfrMfTE MOTOR START PSC SINGLE PHASE MOTOR START ASSIST Economical Solid State Torque Assist for Heat Pumps, Room Air, Commercial and Residential Air Conditioning and Refrigeration Systems Positive Temperature Coefficient Resistors have been used for many years
    OCR Scan PDF
    d6f-w01a1
    MEMS Air Velocity Sensor D6F-W01A1/04A1 Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection RoHS / Lead-free and lead solder compatible Precision uni-directional air velocity detection Integral passive Dust Segregation System (DSS)
    Original PDF
    305c series
    305C Series Vishay Cera-Mite PTCR Motor Start Packages PSC Single Phase Motor Start Assist ECONOMICAL SOLID STATE TORQUE ASSIST FOR HEAT PUMPS, ROOM AIR, COMMERCIAL AND RESIDENTIAL AIR CONDITIONING AND REFRIGERATION SYSTEMS Positive Temperature Coefficient Resistors have been
    Original PDF
    velocity sensor
    MEMS Air Velocity Sensor D6F-W MEMS precision technology for repeatable airflow velocity detection. • Precision uni-directional air velocity detection with ±5% full-scale repeatable accuracy. • Integral passive Dust Segregation System (DSS) prevents contamination of sensor element.
    Original PDF
    sw112
    Miniature Flow Monitor SW112 for air and inert gases Description The Miniature Flow Monitor SW112 operates on the proven calorimetric principle and is designed to operate with air or inert gases. Self-contained sensor head with integral electronic circuitry.
    Original PDF
    305C Series Vishay Cera-Mite PTCR Motor Start
    305C Series Vishay Cera-Mite PTCR Motor Start Packages PSC Single Phase Motor Start Assist • ECONOMICAL SOLID STATE TORQUE ASSIST FOR HEAT PUMPS, ROOM AIR, COMMERCIAL AND RESIDENTIAL AIR CONDITIONING AND REFRIGERATION SYSTEMS Positive Temperature Coefficient Resistors have been used
    Original PDF
    305c
    305C Series Vishay Cera-Mite PTCR Motor Start Packages PSC Single Phase Motor Start Assist ECONOMICAL SOLID STATE TORQUE ASSIST FOR HEAT PUMPS, ROOM AIR, COMMERCIAL AND RESIDENTIAL AIR CONDITIONING AND REFRIGERATION SYSTEMS Positive Temperature Coefficient Resistors have been used
    Original PDF
    velocity sensor
    Text MEMS Air Velocity Sensor – D6F-W01A1/04A1 Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection ■ RoHS / Lead-free and lead solder compatible ■ Precision uni-directional air velocity detection ■ Integral passive Dust Segregation
    Original PDF
    305C Series Vishay Cera-Mite PTCR Motor Start
    305C Series Vishay Cera-Mite PTCR Motor Start Packages PSC Single Phase Motor Start Assist • ECONOMICAL SOLID STATE TORQUE ASSIST FOR HEAT PUMPS, ROOM AIR, COMMERCIAL AND RESIDENTIAL AIR CONDITIONING AND REFRIGERATION SYSTEMS Positive Temperature Coefficient Resistors have been used
    Original PDF
    How Air Velocity Affects The Thermal Performance
    How Air Velocity Affects The Thermal Performance of Heat Sinks: A Comparison of Straight Fin, Pin Fin and maxiFLOWTM Architectures Introduction A device’s temperature affects its op- Air, Ta erational performance and lifetime. To achieve a desired device temperature,
    Original PDF
    Centrifugal Fan 100mm Centrifugal Fan C100 ■
    Centrifugal Fan 100mm Centrifugal Fan C100 ■ Features Energy-saving ・Power consumption: 10.56 W Low noise ・Sound Pressure Level: 60 dB(A) Large air flow and high static pressure ・Maximum air flow : 1.77 m3/min ・Maximum static pressure : 560 Pa φ
    Original PDF