Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AIR FLOW DETECTOR Search Results

    AIR FLOW DETECTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UE36C1620005D6A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 21.5mm high fin pin style heat sink, front to back air flow PDF
    UE36C1650005A3A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 6.5mm height fin pin style heat sink, front to back air flow PDF
    UE36-C26200-05C3A
    Amphenol Communications Solutions 1x2 QSFP-DD cage with SAN height fin pin style heat sink, side to side air flow PDF
    UE36C162000511A
    Amphenol Communications Solutions 1x1 QSFP-DD cage with 10.4mm height fin pin style heat sink, front to back air flow PDF
    MHM320-31
    Murata Manufacturing Co Ltd Sensors/Detector Modules PDF

    AIR FLOW DETECTOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    AIR FLOW DETECTOR

    Abstract: air flow detector sensor NRP-345 wind velocity sensor
    Contextual Info: Air Flow Detector D6A-N Air Flow detector specifically to detect clogged conditions in air filters on servers and other types of computer equipment • Detects the clogged conditions of air filters more efficiently than a conventional time totalling meter


    Original
    NRP-345 AIR FLOW DETECTOR air flow detector sensor wind velocity sensor PDF

    QBM81-3

    Abstract: QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529
    Contextual Info: 1 Differential Pressure Detector 552 QBM81-. for monitoring of air pressure Differential pressure detector for ventilation and air conditioning systems • For monitoring of air filters, air flow, fan belts • For monitoring of pressure in clean rooms, kitchens etc.


    Original
    QBM81-. CA1N1552E QBM81-3 QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529 PDF

    Heating, Ventilation and Air Conditioning

    Contextual Info: 565C1 Hotwire Air Velocity Meter APPLICATIONS • Air flow measurements in heating, ventilation and air conditioning systems • Where low and high feet per minute readings are critical - you must use a hot wire below 80 feet per minute. Comes hardwired with protective boot A604


    Original
    RS-232 565C5-0905 Heating, Ventilation and Air Conditioning PDF

    PF2W740

    Abstract: PF2W704 PF2A551 PF2A31 PF2A20 PF2W300 PF2A200 Nitrogen Relief Valve PF2A703H-69 PF2W720
    Contextual Info: CAT.ES100-54 A -UK Digital Flow Switches For Air Series PF2A For Water Series PF2W For De-ionised Water and Chemicals Body and Sensor New PFA Tube Super PFA Series PF2D 4-channel Flow Monitor 1 2 4 3 Series PF2 २200 Flow rate setting and monitoring are possible


    Original
    ES100-54 SLO-8360 PF2W740 PF2W704 PF2A551 PF2A31 PF2A20 PF2W300 PF2A200 Nitrogen Relief Valve PF2A703H-69 PF2W720 PDF

    AIR FLOW DETECTOR circuit

    Abstract: huba Differential pressure transmitter AIR high pressure pressure transmitter "Pressure transmitter"
    Contextual Info: Differential pressure transmitter Type 698 Technical The type 698 series of differential pressure modules is especially suitable for monitoring air flow and differential pressure in air conditioning systems. data The versions with and without liwith switches are supplied in casings of different sizes.


    Original
    PDF

    air bubbler level control

    Abstract: water level sensor bubbler water level control bubbler air pressure sensor tube by-pass valve BLS100 5K25A 7490 JIS-10K-100A level measurement bubbler
    Contextual Info: BLS Series – Air Bubbler Level Measurement System Rev. 4.02 • Applications The BLS is ideal for measuring drainage, night soil or sewage water with high viscosity and/or suspended solids. ■ The BLS system operates by bubbling a small flow of air from


    Original
    BLS1000 air bubbler level control water level sensor bubbler water level control bubbler air pressure sensor tube by-pass valve BLS100 5K25A 7490 JIS-10K-100A level measurement bubbler PDF

    Contextual Info: SL-DA4R Series Analog Addressable Duct Smoke Detectors Hi-Temp, Low-FLow & No-Tools Description The SL-DA4R Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving


    Original
    STN-10 24VAC 24VDC PDF

    Contextual Info: Flow DS 400 Flow measurement for compressed air and gases New chart recorder DS 400 ‡ 3.5“ graphic display with touch screen shows the progression of the measured values in graphic form ‡ VHQVRULQSXWVIRUÀRZVHQVRUVGHZSRLQW sensors ‡ USB interface for reading out the data


    Original
    PDF

    RDM4010S

    Abstract: RDH4010S RDL4010S RDL4010B RDL4010S5 RDM4010B5 RDL4010B2 RDH4010B2 RDH4010S5 RDM4010S2
    Contextual Info: Rotation 40x40x10mm Air Flow Unit: mm Performance Curves 4.00 General Specification: Frame and Impeller : Thermal Plastic , UL 94V-0 Lead Wires : UL Type + : Red ( - ) : Black Operation Temperature : -10 70 35% 85%RH Storage Temperature : -40 80 35% 85%RH


    Original
    40x40x10mm RDH4010S5 M4010S5 RDL4010S5 RDH4010B5 RDM4010B5 RDM4010S RDL4010S RDH4010B RDM4010B RDM4010S RDH4010S RDL4010S RDL4010B RDL4010S5 RDM4010B5 RDL4010B2 RDH4010B2 RDH4010S5 RDM4010S2 PDF

    RBM5015B2

    Abstract: RBH5015B RBH5015B2 RBL5015S5 RBH5015S RBH5015S5 RBM5015S RBM5015B RBH5015S2 RBL5015B
    Contextual Info: 51x51x15mm Blower Rotation Air Flow Unit: mm Performance Curves General Specification: Frame and Impeller : Thermal Plastic , UL 94V-0 Lead Wires : UL Type ( + ) : Red ( - ) : Black Operation Temperature : -10 70 35% 85%RH Storage Temperature : -40 80 35% 85%RH


    Original
    51x51x15mm RBH5015S5 RBM5015S5 RBL5015S5 RBH5015B5 RBM5015B5 RBL5015B5 RBH5015S RBM5015S RBL5015S RBM5015B2 RBH5015B RBH5015B2 RBH5015S5 RBM5015B RBH5015S2 RBL5015B PDF

    sunon fan gm1203pfv1-8

    Abstract: SMR-02V-B 2510 connector molex AMP PBT connector 5263PBT XHP-2 sph-002t GM0503PFV2-8 GM1203PFV1-8 h jst 10 connector
    Contextual Info: 30x30x10 mm MagLev Green Motor Fan 4.6~5.5 CFM Model P/N GM0503PFV1-8 GM0503PFV2-8 GM1203PFV1-8 GM1203PFV2-8 Rating Voltage Power Current Power Consumption Speed Air Flow Static Pressure Noise VAPO 2BALL VDC (AMP) (WATTS) (RPM) (CFM) (Inch-H2O) (dBA) (g)


    Original
    30x30x10 GM0503PFV1-8 GM0503PFV2-8 GM1203PFV1-8 GM1203PFV2-8 UL1571, 28AWG DF13-2S-1 2695-02RP 2695-03RP sunon fan gm1203pfv1-8 SMR-02V-B 2510 connector molex AMP PBT connector 5263PBT XHP-2 sph-002t GM0503PFV2-8 GM1203PFV1-8 h jst 10 connector PDF

    FMA-902-V-R

    Contextual Info: FLOW & LEVEL INSTRUMENTATION General-Purpose Air Velocity Transducers Models with Remote Electronics add “-R” Suffix MADE IN USA FMA-900 Series $ 822 Model FMA-902-V-R, $852 Shown smaller than actual size Basic Unit FMA-900 Shown Smaller Than Actual Size


    Original
    FMA-900 FMA-902-V-R, FMA-900 accurat82 FMA-904-I, FMA-902-V-R PDF

    Connector 2510-02

    Abstract: eci 2510 molex 2759T molex Connector 5264 JST, SPH-002T-P0.5S AMP PBT connector SC25-02HG SEH-001T-P0.6 SMR-02V-B 2510 connector molex
    Contextual Info: 25x25x6 mm MagLev Green Motor Fan 2.2~3.0 CFM Model P/N GM0502PEV1-8 GM0502PEV2-8 VAPO Rating Voltage Power Current Power Consumption 2BALL VDC (AMP) (WATTS) Bearing N.GN N.GN 5 5 0.11 0.08 0.6 0.4 Speed Air Flow Static Pressure Noise Weight (RPM) (CFM)


    Original
    25x25x6 GM0502PEV1-8 GM0502PEV2-8 UL3265, 28AWG DF13-2S-1 2695-02RP 2695-03RP SC25-02HG SMR-02V-B Connector 2510-02 eci 2510 molex 2759T molex Connector 5264 JST, SPH-002T-P0.5S AMP PBT connector SC25-02HG SEH-001T-P0.6 SMR-02V-B 2510 connector molex PDF

    GM0501PFV1-8

    Abstract: ul1571 SYM-001T-P0.6 SHF-001T-0.8BS SEH-001T-P0.6 molex 2759T JWT Connector Connector 2510-02 molex Connector 5264 SMR-02V-B
    Contextual Info: 20x20x10 mm MagLev Green Motor Fan 1.5~1.9 CFM Model P/N GM0501PFV1-8 GM0501PFV2-8 VAPO Rating Voltage Power Current Power Consumption 2BALL VDC (AMP) (WATTS) Bearing N.GN N.GN 5 5 1.1 0.9 0.21 0.18 Air Flow Static Pressure Noise (RPM) (CFM) (Inch-H2O) (dBA)


    Original
    20x20x10 GM0501PFV1-8 GM0501PFV2-8 UL1571, 28AWG DF13-2S-1 2695-02RP 2695-03RP SC25-02HG SMR-02V-B GM0501PFV1-8 ul1571 SYM-001T-P0.6 SHF-001T-0.8BS SEH-001T-P0.6 molex 2759T JWT Connector Connector 2510-02 molex Connector 5264 SMR-02V-B PDF

    Contextual Info: date 10/15/2012 page 1 of 4 SERIES: CFM 50 │ DESCRIPTION: DC AXIAL FAN FEATURES • • • • 50 x 50 mm frame high fan speed for greater air flow two ball bearing construction auto restart protection standard on all models RoHS operating voltage rated


    Original
    CFM-5010-03-10 CFM-5010-03-11 CFM-5010-03-20 CFM-5010-03-22 CFM-5010-13-10 CFM-5010-13-11 CFM-5010-13-20 CFM-5010-13-22 PDF

    Contextual Info: date 10/15/2012 page 1 of 5 SERIES: CFM 80 │ DESCRIPTION: DC AXIAL FAN FEATURES • • • • 80 x 80 mm frame high fan speed for greater air flow two ball bearing construction auto restart protection standard on all models RoHS operating voltage rated


    Original
    CFM-8010-13-10 CFM-8010-13-11 CFM-8010-13-20 CFM-8010-13-22 CFM-8015-13-10 CFM-8015-13-11 CFM-8015-13-20 CFM-8015-13-22 CFM-8025-13-10 CFM-8025-13-11 PDF

    Contextual Info: date 10/15/2012 page 1 of 4 SERIES: CFM 40 │ DESCRIPTION: DC AXIAL FAN FEATURES • • • • 40 x 40 mm frame high fan speed for greater air flow two ball bearing construction auto restart protection standard on all models RoHS operating voltage rated


    Original
    CFM-4010-03-10 CFM-4010-03-11 CFM-4010-03-20 CFM-4010-03-22 CFM-4010-13-10 CFM-4010-13-11 CFM-4010-13-20 CFM-4010-13-22 PDF

    Contextual Info: date 10/15/2012 page 1 of 4 SERIES: CFM 92 │ DESCRIPTION: DC AXIAL FAN FEATURES • • • • 92 x 92 mm frame high fan speed for greater air flow two ball bearing construction auto restart protection standard on all models RoHS operating voltage rated


    Original
    CFM-9225-13-10 CFM-9225-13-11 CFM-9225-13-20 CFM-9225-13-22 CFM-9225-23-10 CFM-9225-23-11 CFM-9225-23-20 CFM-9225-23-22 PDF

    PF2W704

    Abstract: PF2W740 3-digit object counter circuit PF2A PF2W720 Yamatake 3000 flow elements PF2D540 PF2D300-A ifw51 PF2A711
    Contextual Info: Flow Switches Series PF2 „, IF „ ZSE„ ISE„ Digital Flow Switch PSE Digital Flow Switch for Air: Series PF2A •························································ Refer to page 16-11-7. Digital Flow Switch for Water: Series PF2W ··················································· Refer to page 16-11-17.


    Original
    IFW510 IFW520 IFW550 Jeddah-21471, PF2W704 PF2W740 3-digit object counter circuit PF2A PF2W720 Yamatake 3000 flow elements PF2D540 PF2D300-A ifw51 PF2A711 PDF

    PF2A

    Abstract: PF2A751 1F33 PF2A710 PF2A721 PF2A711 PF2W704 air detection IFW510 706H
    Contextual Info: Flow Switches Series PF2 „, IF „ ZSE„ ISE„ Digital Flow Switch PSE Digital Flow Switch for Air: Series PF2A •························································ Refer to page 16-11-7. Digital Flow Switch for Water: Series PF2W ··················································· Refer to page 16-11-17.


    Original
    IFW510 IFW520 IFW550 PF2A511 PF2A550 PF2A551 PF2W504 PF2W504T PF2W520 PF2W520T PF2A PF2A751 1F33 PF2A710 PF2A721 PF2A711 PF2W704 air detection IFW510 706H PDF

    ZBD42203

    Abstract: SCH40 5K80A JIS10K NSH4 blow down valve gas detector 200VA SUS304 15ASGP
    Contextual Info: IN-SITU ZIRCONIA OXYGEN ANALYZER <ZIRCOMAT-P> DATA SHEET This oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control. The detector ZFK used with the analyzer is directly


    Original
    10K65ARF) ZBD42203 SCH40 5K80A JIS10K NSH4 blow down valve gas detector 200VA SUS304 15ASGP PDF

    uras26 gas module sensor

    Abstract: Uras26 Magnos206 uras26 manual ZO23 EL3020 AO2000-Magnos206 EL3040 Limas23 Caldos27
    Contextual Info: EasyLine Continuous Gas Analyzers EL3000 Series Models EL3020, EL3040 Data Sheet 10/24 4.10 EN November 2009 „ Detectors with different measurement principles for „ Customizable analog outputs, digital inputs and numerous process and emission monitoring


    Original
    EL3000 EL3020, EL3040 CSA-C22 uras26 gas module sensor Uras26 Magnos206 uras26 manual ZO23 EL3020 AO2000-Magnos206 EL3040 Limas23 Caldos27 PDF

    Contextual Info: LG01-2000Axxx Liquid Flow Switch and Bubble Detector Detection of low liquid flow in the ml-Range Totally non invasive Ultra fast response time of 100 ms • •  1 Introduction LG01 The LG01 Liquid Flow Switch enables detection of flow of liquid in the range of ml/min. The output signal is 5V when


    Original
    LG01-2000Axxx CH-8712 PDF

    fire alarm design

    Contextual Info: AAD-8100 Intelligent FAAST Fire Alarm Aspiration Sensing Technology Description The Gamewell-FCI, Intelligent FAAST , AAD-8100 Aspirating Smoke Detector combines dual source blue LED and infrared laser , optical smoke detection with the fire alarm control panel connectivity, via the Velociti mode to


    Original
    AAD-8100 AAD-8100 F-A3384-000 fire alarm design PDF