    SE1006023111111
    Amphenol Communications Solutions Slim Cool Edge 0.65mm, Surface mount, 60 signal pins, Vertical PDF
    SE1016023111111
    Amphenol Communications Solutions Slim Cool Edge 0.65mm, Surface mount, 160 signal pins, Vertical PDF
    SE1004023111111
    Amphenol Communications Solutions Slim Cool Edge 0.65mm, Surface mount, 40 signal pins, Vertical PDF
    SE1012023111111
    Amphenol Communications Solutions Slim Cool Edge 0.65mm, Surface mount, 120 signal pins, Vertical PDF
    SE1022026111211
    Amphenol Communications Solutions Cool Edge,Surface mount,220 signal pins, 0.65 mm, Vertical PDF

    Documents mentioning AIR COOLING

    Document Partial File Text Tags Type PDF
    Thermal Management: Air Conditioners Air
    Thermal Management: Air Conditioners Air Conditioners Spec-00181 EPH (763) 422-2211 FX 422-2600 Air (763) Conditioners Thermal Management Air Conditioners Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. Application Outdoor Air Conditioners provide high-efficiency positive cooling
    Original PDF
    br 161
    BR 161/FEB. 1955 ) Triode Type BR 161 HF AMPLIFIER AND OSCILLATOR General. The BR 161 is a forced-air-cooled transmit­ ting triode fitted with a thoriated tungsten filament. Cooling. The anode requires forced air cooling. The air flow and air cooling characteristics given show air
    OCR Scan PDF
    transmitting triode
    BR 129/JULY 1954 Triode Type BR 129 HF AMPLIFIER AND OSCILLATOR General. The BR 129 is a forced-air-cooled transmitting triode fitted with a tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the
    OCR Scan PDF
    BR 179/FEB. 1955 aironi Triode Type BR 179
    BR 179/FEB. 1955 aironi Triode Type BR 179 General. The BR 179 is a forced-air-cooled transmit­ ting triode fitted with a thoriated tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the
    OCR Scan PDF
    aa-024-12-22
    AA PowerCool Series, AA-024-12-22 Thermoelectric Assembly Innovative Technology for a Connected World PowerCool series air-to-air thermoelectric assembly The AA PowerCool Series is an Air-to-Air thermoelectric assembly (TEA) that uses impingement flow to transfer heat. It offers dependable, compact performance by cooling objects via
    Original PDF
    137b
    BR137B/JULY 1954 v in o n i Triode Type BR 137B HF AMPLIFIER AND OSCILLATOR _4 703_ . DIA.. General. The BR 137B is a forced-air-cooled trans­ mitting triode fitted with a tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the
    OCR Scan PDF
    BR 137/JULY 1954 Â v in o n i I \ \ \ \ ■ Triode
    BR 137/JULY 1954 Â v in o n i I \ \ \ \ ■ Triode Type BRI 37 HF AMPLIFIER AND OSCILLATOR General. The BR 137 is a forced-air-cooled transmit­ ting triode fitted with a tungsten filament. Cooling. The anode requires forced air cooling. The air cooling and air flow characteristics given show the
    OCR Scan PDF
    Application Note Sensors for Air-conditioning in
    Application Note Sensors for Air-conditioning in Automobiles www.epcos.com Notes Application Note Sensors for air-conditioning in automobiles Contents Sensors for air-conditioning in automobiles…3
    Original PDF
    BR 175/JULY 1954 Triode TypeBR175 H F A M PLIFIER
    BR 175/JULY 1954 Triode TypeBR175 H F A M PLIFIER AND OSCILLATOR General. The BR 175 is a forced-air-cooled transm it­ ting triode fitted with a tungsten fijament. Cooling. The anode requires forced air cooling. The characteristics given show the air inlet temperature
    OCR Scan PDF
    AA Tunnel Series, AA-035-24-22 Thermoelectric
    AA Tunnel Series, AA-035-24-22 Thermoelectric Assembly Innovative Technology for a Connected World Tunnel series air-to-air thermoelectric assembly The AA Tunnel Series is an Air-to-Air thermoelectric assembly (TEA) that minimizes the number of airflow paths required to operate. It offers dependable, compact performance
    Original PDF
    AA Tunnel Series, AA-027-12-22 Thermoelectric
    AA Tunnel Series, AA-027-12-22 Thermoelectric Assembly Innovative Technology for a Connected World Tunnel series air-to-air thermoelectric assembly The AA Tunnel Series is an Air-to-Air thermoelectric assembly (TEA) that minimizes the number of airflow paths required to operate. It offers dependable, compact performance
    Original PDF
    ACT 14/JULY 1954 Triode Type ACT 14 H F A M
    ACT 14/JULY 1954 Triode Type ACT 14 H F A M PLIFIER AN D OSCILLATOR General. A forced-air cooled transmitting triode fitted with a tungsten filament. Cooling. The anode requires cooling by air blast and the volume of air necessary is 600 cu. ft. per minute at
    OCR Scan PDF
    Quality Products. Service Excellence. 105-550 CFM
    Quality Products. Service Excellence. 105-550 CFM Filtered Fan Boxes XF Series Description In a typical cooling arrangement, the filtered fan box pulls air into the enclosures and the filter grill is used as an air outlet. The washable aluminum filter grill and the air filter are easily accessible
    Original PDF
    3-1000h
    3-1000H HIGH MU POWER TRIODE The 3-1000H is cooled by radiation from the plate and by circulation of forced air through the base, around the envelope and over the plate seal. Cooling is simplified by using the SK-510 Air-system Socket and SK-516 Air Chimney.