Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ADXL50 DATA SHEET Search Results

    ADXL50 DATA SHEET Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-52RJ11SNNE-010
    Amphenol Cables on Demand Amphenol MP-52RJ11SNNE-010 Shielded CAT5e 2-Pair RJ11 Data Cable [AT&T U-Verse & Verizon FiOS Data Cable] - CAT5e PBX Patch Cable with 6P6C RJ11 Connectors (Straight-Thru) 10ft PDF
    MP-52RJ11UNNE-015
    Amphenol Cables on Demand Amphenol MP-52RJ11UNNE-015 CAT5e 2-Pair RJ11 Data Cable [AT&T U-Verse & Verizon FiOS Data Cable] - CAT5e PBX Patch Cable with 6P6C RJ11 Connectors (Straight-Thru) 15ft PDF
    MP-52RJ11SNNE-007
    Amphenol Cables on Demand Amphenol MP-52RJ11SNNE-007 Shielded CAT5e 2-Pair RJ11 Data Cable [AT&T U-Verse & Verizon FiOS Data Cable] - CAT5e PBX Patch Cable with 6P6C RJ11 Connectors (Straight-Thru) 7ft PDF
    MP-52RJ11UNNE-010
    Amphenol Cables on Demand Amphenol MP-52RJ11UNNE-010 CAT5e 2-Pair RJ11 Data Cable [AT&T U-Verse & Verizon FiOS Data Cable] - CAT5e PBX Patch Cable with 6P6C RJ11 Connectors (Straight-Thru) 10ft PDF
    MP-52RJ11SNNE-015
    Amphenol Cables on Demand Amphenol MP-52RJ11SNNE-015 Shielded CAT5e 2-Pair RJ11 Data Cable [AT&T U-Verse & Verizon FiOS Data Cable] - CAT5e PBX Patch Cable with 6P6C RJ11 Connectors (Straight-Thru) 15ft PDF

    Documents mentioning ADXL50 DATA SHEET

    Document Partial File Text Tags Type PDF
    adxl50
    a Monolithic Accelerometer With Signal Conditioning ADXL50* For convenience, the ADXL50 has an internal buffer amplifier with a full 0.25 V to 4.75 V output range. This may be used to set the zero-g level and change the output sensitivity by using external resistors. External capacitors may be added to the resistor network to provide 1 or 2 poles of filtering. No external
    Original PDF
    BACK a Monolithic Accelerometer With Signal
    BACK a Monolithic Accelerometer With Signal Conditioning ADXL50* For convenience, the ADXL50 has an internal buffer amplifier with a full 0.25 V to 4.75 V output range. This may be used to set the zero-g level and change the output sensitivity by using external resistors. External capacitors may be added to the resistor network to provide 1 or 2 poles of filtering. No external
    Original PDF
    an-377
    ANALOG ► DEVICES AN-377 APPLICATION NOTE ONE TECHNOLOGY WAY • P.O. BOX 9106 • NORWOOD, MASSACHUSETTS 02062-9106 • 617/329-4700 Increasing the Frequency Response of the ADXL50 by Mike Shuster and Bob Briano The ADXL50 is specified and tested for operation over
    OCR Scan PDF
    an-377
    a ONE TECHNOLOGY WAY AN-377 APPLICATION NOTE • P.O. BOX 9106 • NORWOOD, MASSACHUSETTS 02062-9106 • 617/329-4700 Increasing the Frequency Response of the ADXL Series Accelerometers by Mike Shuster, Bob Briano and Charles Kitchin The ADXL series of accelerometers are specified and
    Original PDF
    an-396
    a ONE TECHNOLOGY WAY • P.O. AN-396 APPLICATION NOTE BOX 9106 • NORWOOD, • 617/329-4700 MASSACHUSETTS 02062-9106 Understanding Accelerometer Scale Factor and Offset Adjustments by Charles Kitchin INTRODUCTION The ADXL50 and ADXL05 accelerometers are small, low
    Original PDF
    a Monolithic Accelerometer With Signal
    a Monolithic Accelerometer With Signal Conditioning ADXL50* For convenience, the ADXL50 has an internal buffer amplifier with a full 0.25 V to 4.75 V output range. This may be used to set the zero-g level and change the output sensitivity by using external resistors. External capacitors may be added to the resistor network to provide 1 or 2 poles of filtering. No external
    Original PDF
    an-376
    ANALOG ► DEVICES AN-376 APPLICATION NOTE ONE TECHNOLOGY WAY • P.O. BOX 9106 • NORWOOD, MASSACHUSETTS 02062-9106 • 617/329-4700 Using the ADXL50EM Accelerometer Evaluation Module by Charles Kitchin, Bob Briano, and Mike Shuster IMPORTANT FEATURES 1. Com plete Mechanically Assembled Acceleration
    OCR Scan PDF
    adxl50
    ADXL50/ADXL05 Evaluation Modules ADXL50EM-1, ADXL05EM-1/EM-3 a FEATURES High Performance Prepackaged Accelerometers Complete Acceleration Measurement System Single and Multiaxis Versions Small, Low Cost, Ready-to-Use Available in ؎4 g or ؎25 g Full-Scale Ranges
    Original PDF
    ORCA-2: Old Dog, New Tricks Joshua F. Apgar,
    ORCA-2: Old Dog, New Tricks Joshua F. Apgar, Katrina L. Berube, Matthew D. Hancher, Andrew S. Huang, Linda E. Kiley, Frank Lee, Marisa J. Kirschbaum, Ara N. Knaian, Jacky Mallett, Seth O. Newburg, Hongshen Ma, Matthew S. Reynolds, Martin T. Stiaszny Massachusetts Institute of Technology
    Original PDF
    adxl05
    a ؎1 g to ؎5 g Single Chip Accelerometer with Signal Conditioning ADXL05* floor is 500 µg/√Hz, (12× less than the ADXL50), allowing signals below 5 milli-g to be resolved. The ADXL05 is a force balanced capacitive accelerometer with the capability to measure
    Original PDF
    a ؎1 g to ؎5 g Single Chip Accelerometer with
    a ؎1 g to ؎5 g Single Chip Accelerometer with Signal Conditioning ADXL05* floor is 500 µg/√Hz, (12× less than the ADXL50), allowing signals below 5 milli-g to be resolved. The ADXL05 is a force balanced capacitive accelerometer with the capability to measure
    Original PDF
    xl05
    BACK a ؎1 g to ؎5 g Single Chip Accelerometer with Signal Conditioning ADXL05* floor is 500 µg/√Hz, (12× less than the ADXL50), allowing signals below 5 milli-g to be resolved. The ADXL05 is a force balanced capacitive accelerometer with the capability to measure
    Original PDF
    adxl05
    ± 1 g to ±5 g Single Chip Accelerometer with Signal Conditioning ANALOG ► DEVICES ADXL05* FEATURES 5 milli-g Resolution Noise Level 12x Less than the ADXL50 User Selectable Full Scale from ±1 g to ±5 g Output Scale Selectable from 200 m V /g to 1 VI g
    OCR Scan PDF
    1the exchange of circuits, systems, and software
    1the exchange of circuits, systems, and software for real-world signal processing A NEW DIRECT-CONVERSION RADIO CHIPSET ELIMINATES IF STAGES (page 3) Logarithmic Amplifiers Explained— Ask the Applications Engineer— 28 (page 30] ll-Electronic Power and Energy Meters (page 64)
    OCR Scan PDF