ABB TRIP UNIT Search Results
ABB TRIP UNIT Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TMPM462F10FG | Toshiba Electronic Devices & Storage Corporation | Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 | Datasheet | ||
| TMPM4GNF20FG | Toshiba Electronic Devices & Storage Corporation | Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP100-1414-0.50-002 | Datasheet | ||
| TMPM4GRF10FG | Toshiba Electronic Devices & Storage Corporation | Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 | Datasheet | ||
| TMPM4KLFWAFG | Toshiba Electronic Devices & Storage Corporation | Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP64-1414-0.80-002 | Datasheet | ||
| TMPM4MLFWAFG | Toshiba Electronic Devices & Storage Corporation | Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP64-1414-0.80-002 | Datasheet |
Documents mentioning ABB TRIP UNIT
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| brown boveri | ABB ASEA BROWN BOVERI ABB Relays High-speed tripping assembly Application The high-speed tripping assembly is used for several protective relays which do not have trip relays. The unit can trip a maximum of five breakers. Design The tripping assembly consists of a high-speed |
OCR Scan | ||||
| Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract | Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract Application Type REXA 101 Single or double-shot, single or three-phase reclosing relay for transmission and subtransmission lines • Automatic high speed or delayed breaker reclosing initiated by protective relay trip |
OCR Scan | ||||
| ragpc | Gil» Mil» ASEA BROWN BOVERI ABB Relays Abstract Application Design Type RAGPC B03-4013E Loss-of-excitation relay for . , synchronous generators Changed since January 1985 Data subject to change without notice » ■ • Alarm for underexcitation and trip for lossof-excitation |
OCR Scan | ||||
| A »11 M W ASEA BROWN BOVERI ABB Relays Abstract | A »11 M W ASEA BROWN BOVERI ABB Relays Abstract Application Type REXA 103 One to four shots, threephase reclosing relay for subtransmission and transmission lines • Automatic high speed or delayed breaker reclosing initiated by protective relay trip • Allows sequential reclosing of breakers in |
OCR Scan | ||||
| rxtcb | A 19 » ASEA BROWN BOVERI ABB Relays Abstract Application Type RXTCB 1 B03-9132E Page 1 January 1987 Changed since M ay 1983 Data subject to change without notice Battery ground-fault desensitizing filter • Superior surge protection, prevents incor rect operation of trip relays without delay |
OCR Scan | ||||
| apf'f % I ® Illf Type REXA im d b io o o 6 - e n | apf'f % I ® Illf Type REXA im d b io o o 6 - e n Auto-reclosing relay £¡22«**.,,** Data subject to change without notice R* ABB Network Control & Protection (SE 90638) Features •A u to m a tic high speed or delayed breaker reclosing initiated by protective relay trip |
OCR Scan | ||||
| T2 100A, 480V ∆ | T2 100A, 480V ∆ Thermal-magnetic/electronic/current limiting Dimensions 3P Fixed Version 5.12H x 3.54W x 2.76D Weight 2.84 (Ibs) T M ma CC x Bs T2 General The T2 breaker family ranges from 15 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays |
Original | ||||
| reb 551 | A l l l i REB 551 * 1.2 Breaker protection terminal ■ , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner (SE950214) Features • Breaker related protection and associated func tions in a numerical unit |
OCR Scan | ||||
| rec316 | Numerical control and protection unit REC316*4 1MRK511016-Ben Page 1 Issued: February 2002 Changed: since December 1999 Data subject to change without notice Features Application • MV and HV systems for power transmission and distribution and for the power |
Original | ||||
| reg216 | Auxiliary unit for REG216/316*4 for 100% stator and rotor earth fault protection REX010/011 1MRB520123-Ben Page 1 Issued: March 2003 Changed since: June 2002 Data subject to change without notice Features • Compact design • Perfectly matched for the REG216/ |
Original | ||||
| REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December | REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December 1997 Changed since October 1997 Data subject to change without nolice Contra I terminal ABB Network Partner Features .Controi functions in a numerical unit sl3parated from the object protection units .Is an advantage to use in the followin~1 applications: |
Original | ||||
| Low voltage circuit breakers Working with trip | Low voltage circuit breakers Working with trip characteristic curves Index 1. Introduction… 2 2. Main Definitions… 3 |
Original | ||||
| fau810 | We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Power System Division 2008 Flame Analysis Unit FAU810 Instruction Manual |
Original | ||||
| Technical catalog ABB molded case circuit | Technical catalog ABB molded case circuit breakers UL 489 and CSA C22.2 Standard ABB SACE S.p.A An ABB Group company L.V. Breakers Via Baioni, 35 24123 Bergamo, Italy Tel.: +39 035.395.111 - Telefax: +39 035.395.306-433 http://www.abb.com ABB molded case circuit breakers - UL 489 and CSA C22.2 Standard |
Original | ||||
|
|
||||||
| insum | MNS Motor Management INSUM® P MCU Parameter Description Version 3.0d ABB ® INSUM MCU Parameter Description Software revision 2.1 ABB ® INSUM MCU Parameter Description Software Version 3.0d 1TGC 901027 M0201 Edition August 2006 ® INSUM MCU Parameter Description Software Version 2.1 |
Original | ||||
| 1sdc210004d0203 | Technical catalogue Tmax Low voltage moulded-case circuit-breakers up to 630 A Preliminary - 1SDC210004D0203 OVERVIEW MAIN CHARACTERISTICS THE RANGES ACCESSORIES CHARACTERISTIC CURVES AND TECHNICAL INFORMATION WIRING DIAGRAMS OVERALL DIMENSIONS ORDERING CODES |
Original | ||||
| insum | IT Protect – MNS Motor Management INSUM MCU Parameter Description Version 3.0 ABB ® INSUM MCU Parameter Description Software revision 2.1 ® INSUM MCU Parameter Description Software Version 3.0 1 1TGC 901026 M0201 Edition August 2003 ® INSUM MCU Parameter Description Software Version 2.1 |
Original | ||||
| ep010 | EP010 Modbus / FBP Interface User and Operator Manual ABB SACE EP010 1SDH000510R0001 L2388 INDEX 1 PAGE INTRODUCTION… 3 2. 3. 1.1 1.2 Applicability… 3 |
Original | ||||
| Pro M Miniature circuit breakers General | Pro M Miniature circuit breakers General information General information CSA C22.2 Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard |
Original | ||||
| reb500 | Numerical Station Protection System REB500 / REB500sys 1MRB520308-Ben Busbar Protection with integrated Breaker Failure, Line and Transformer Protection Page 1 Issued: December 2008 Changed since October 2007 Data subject to change without notice REB500sys - Station protection with distributed architecture |
Original | ||||
| Isomax Molded case circuit breakers S3 – S8 15 Is | Isomax Molded case circuit breakers S3 – S8 15 Is M oma CC x Bs S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = BA = BA3 = S_ = U_ = Auxiliary Switch Bell Alarm Bell Alarm (S6/S7 only) Shunt trip with voltage code Undervoltage release with voltage code |
Original | ||||
| ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three | ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three phase overcurrent and ground-fault relay independent of auxiliary power supply B03-2314E Page 1 January 1989 Changed since January 1987 Data subject to change without notic (860567; Abstract Overcurrent and ground-fault protection |
OCR Scan | ||||
| i | l l I I f * l » I P RALZA an d RALZB im rk | i | l l I I f * l » I P RALZA an d RALZB im rk 506 009-ben Combined directional-wave and ■ ___ impedance baCKlip relay Page 1 February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (SE 82 21 61) Features |
OCR Scan | ||||
| 4021e | Jk mm Type REG 100 Microprocessor based ASEA BROWN BOVERI Q © ri0 r3 tO r pfOt*©CtiOH °?3'4021E S s » **« , Dat3sub*ect t0chan9e without notice ABB Relays (SE900261) Abstract Application • Protection functions included: - Phase short-circuit - Stator ground-fault |
OCR Scan | ||||
| razoa | ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se quential measurement distance relay for overhead lines and cables • Independent X and R reach settings |
OCR Scan | ||||