Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ABB TRIP UNIT Search Results

    ABB TRIP UNIT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TMPM462F10FG
    Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 Datasheet
    TMPM4GNF20FG
    Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP100-1414-0.50-002 Datasheet
    TMPM4GRF10FG
    Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP176-2020-0.40-002 Datasheet
    TMPM4KLFWAFG
    Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP64-1414-0.80-002 Datasheet
    TMPM4MLFWAFG
    Toshiba Electronic Devices & Storage Corporation Arm Cortex-M4 processor with FPU Core Based Microcontroller/32bit/P-LQFP64-1414-0.80-002 Datasheet

    Documents mentioning ABB TRIP UNIT

    Document Partial File Text Tags Type PDF
    brown boveri
    ABB ASEA BROWN BOVERI ABB Relays High-speed tripping assembly Application The high-speed tripping assembly is used for several protective relays which do not have trip relays. The unit can trip a maximum of five breakers. Design The tripping assembly consists of a high-speed
    OCR Scan PDF
    Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract
    Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract Application Type REXA 101 Single or double-shot, single or three-phase reclosing relay for transmission and subtransmission lines • Automatic high speed or delayed breaker reclosing initiated by protective relay trip
    OCR Scan PDF
    ragpc
    Gil» Mil» ASEA BROWN BOVERI ABB Relays Abstract Application Design Type RAGPC B03-4013E Loss-of-excitation relay for . , synchronous generators Changed since January 1985 Data subject to change without notice » ■ • Alarm for underexcitation and trip for lossof-excitation
    OCR Scan PDF
    A »11 M W ASEA BROWN BOVERI ABB Relays Abstract
    A »11 M W ASEA BROWN BOVERI ABB Relays Abstract Application Type REXA 103 One to four shots, threephase reclosing relay for subtransmission and transmission lines • Automatic high speed or delayed breaker reclosing initiated by protective relay trip • Allows sequential reclosing of breakers in
    OCR Scan PDF
    rxtcb
    A 19 » ASEA BROWN BOVERI ABB Relays Abstract Application Type RXTCB 1 B03-9132E Page 1 January 1987 Changed since M ay 1983 Data subject to change without notice Battery ground-fault desensitizing filter • Superior surge protection, prevents incor­ rect operation of trip relays without delay­
    OCR Scan PDF
    apf'f % I ® Illf Type REXA im d b io o o 6 - e n
    apf'f % I ® Illf Type REXA im d b io o o 6 - e n Auto-reclosing relay £¡22«**.,,** Data subject to change without notice R* ABB Network Control & Protection (SE 90638) Features •A u to m a tic high speed or delayed breaker reclosing initiated by protective relay trip
    OCR Scan PDF
    T2 100A, 480V ∆
    T2 100A, 480V ∆ Thermal-magnetic/electronic/current limiting Dimensions 3P Fixed Version 5.12H x 3.54W x 2.76D Weight 2.84 (Ibs) T M ma CC x Bs T2 General The T2 breaker family ranges from 15 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays
    Original PDF
    reb 551
    A l l l i REB 551 * 1.2 Breaker protection terminal ■ , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner (SE950214) Features • Breaker related protection and associated func­ tions in a numerical unit
    OCR Scan PDF
    rec316
    Numerical control and protection unit REC316*4 1MRK511016-Ben Page 1 Issued: February 2002 Changed: since December 1999 Data subject to change without notice Features Application • MV and HV systems for power transmission and distribution and for the power
    Original PDF
    reg216
    Auxiliary unit for REG216/316*4 for 100% stator and rotor earth fault protection REX010/011 1MRB520123-Ben Page 1 Issued: March 2003 Changed since: June 2002 Data subject to change without notice Features • Compact design • Perfectly matched for the REG216/
    Original PDF
    REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December
    REC 561 * 1.1 1MAK 511 DOg-BEN Page 1 December 1997 Changed since October 1997 Data subject to change without nolice Contra I terminal ABB Network Partner Features .Controi functions in a numerical unit sl3parated from the object protection units .Is an advantage to use in the followin~1 applications:
    Original PDF
    Low voltage circuit breakers Working with trip
    Low voltage circuit breakers Working with trip characteristic curves Index 1. Introduction… 2 2. Main Definitions… 3
    Original PDF
    fau810
    We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden.  ABB Power System Division 2008 Flame Analysis Unit FAU810 Instruction Manual
    Original PDF
    Technical catalog ABB molded case circuit
    Technical catalog ABB molded case circuit breakers UL 489 and CSA C22.2 Standard ABB SACE S.p.A An ABB Group company L.V. Breakers Via Baioni, 35 24123 Bergamo, Italy Tel.: +39 035.395.111 - Telefax: +39 035.395.306-433 http://www.abb.com ABB molded case circuit breakers - UL 489 and CSA C22.2 Standard
    Original PDF
    insum
    MNS Motor Management INSUM® P MCU Parameter Description Version 3.0d ABB ® INSUM MCU Parameter Description Software revision 2.1 ABB ® INSUM MCU Parameter Description Software Version 3.0d 1TGC 901027 M0201 Edition August 2006 ® INSUM MCU Parameter Description Software Version 2.1
    Original PDF
    1sdc210004d0203
    Technical catalogue Tmax Low voltage moulded-case circuit-breakers up to 630 A Preliminary - 1SDC210004D0203 OVERVIEW MAIN CHARACTERISTICS THE RANGES ACCESSORIES CHARACTERISTIC CURVES AND TECHNICAL INFORMATION WIRING DIAGRAMS OVERALL DIMENSIONS ORDERING CODES
    Original PDF
    insum
    IT Protect – MNS Motor Management INSUM MCU Parameter Description Version 3.0 ABB ® INSUM MCU Parameter Description Software revision 2.1 ® INSUM MCU Parameter Description Software Version 3.0 1 1TGC 901026 M0201 Edition August 2003 ® INSUM MCU Parameter Description Software Version 2.1
    Original PDF
    ep010
    EP010 Modbus / FBP Interface User and Operator Manual ABB SACE EP010 1SDH000510R0001 L2388 INDEX 1 PAGE INTRODUCTION… 3 2. 3. 1.1 1.2 Applicability… 3
    Original PDF
    Pro M Miniature circuit breakers General
    Pro M Miniature circuit breakers General information General information CSA C22.2 Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard
    Original PDF
    reb500
    Numerical Station Protection System REB500 / REB500sys 1MRB520308-Ben Busbar Protection with integrated Breaker Failure, Line and Transformer Protection Page 1 Issued: December 2008 Changed since October 2007 Data subject to change without notice REB500sys - Station protection with distributed architecture
    Original PDF
    Isomax Molded case circuit breakers S3 – S8 15 Is
    Isomax Molded case circuit breakers S3 – S8 15 Is M oma CC x Bs S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = BA = BA3 = S_ = U_ = Auxiliary Switch Bell Alarm Bell Alarm (S6/S7 only) Shunt trip with voltage code Undervoltage release with voltage code
    Original PDF
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three phase overcurrent and ground-fault relay independent of auxiliary power supply B03-2314E Page 1 January 1989 Changed since January 1987 Data subject to change without notic (860567; Abstract Overcurrent and ground-fault protection
    OCR Scan PDF
    i | l l I I f * l » I P RALZA an d RALZB im rk
    i | l l I I f * l » I P RALZA an d RALZB im rk 506 009-ben Combined directional-wave and ■ ___ impedance baCKlip relay Page 1 February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (SE 82 21 61) Features
    OCR Scan PDF
    4021e
    Jk mm Type REG 100 Microprocessor based ASEA BROWN BOVERI Q © ri0 r3 tO r pfOt*©CtiOH °?3'4021E S s » **« , Dat3sub*ect t0chan9e without notice ABB Relays (SE900261) Abstract Application • Protection functions included: - Phase short-circuit - Stator ground-fault
    OCR Scan PDF
    razoa
    ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se­ quential measurement distance relay for overhead lines and cables • Independent X and R reach settings
    OCR Scan PDF