    ABB SINGLE-PHASE OVERCURRENT Search Results

    ABB SINGLE-PHASE OVERCURRENT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    FO-9LPBMTRJ00-001
    Amphenol Cables on Demand Amphenol FO-9LPBMTRJ00-001 MT-RJ Connector Loopback Cable: Single-Mode 9/125 Fiber Optic Port Testing .1m PDF
    AV-THLIN2RCAM-005
    Amphenol Cables on Demand Amphenol AV-THLIN2RCAM-005 Thin-line Single RCA Coaxial Cable - RCA Male / RCA Male (Coaxial Digital Audio Compatible) 5ft PDF
    CS-SASSDP8282-001
    Amphenol Cables on Demand Amphenol CS-SASSDP8282-001 29 position SAS to SATA Drive Connector Single Data Lane Cable 1m PDF
    FO-DLSCDLLC00-001
    Amphenol Cables on Demand Amphenol FO-DLSCDLLC00-001 SC-LC Duplex Single-Mode 9/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x SC Male to 2 x LC Male 1m PDF
    FO-DLSCDLLC00-002
    Amphenol Cables on Demand Amphenol FO-DLSCDLLC00-002 SC-LC Duplex Single-Mode 9/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x SC Male to 2 x LC Male 2m PDF

    Documents mentioning ABB SINGLE-PHASE OVERCURRENT

    Document Partial File Text Tags Type PDF
    rxig 21
    A IIII | l | | l l ASEA BROWN BOVERI Instantaneous or definitetime ac overcurrent relay assemblies (RXIG 21, 22, 28) B03-2035E ^ ; 1989 Data subject to change without notice ABB Relays (830504) Abstract Application • Single-phase, two-phase or three-phase
    OCR Scan PDF
    rxil 2
    A S p Sp ASEA BROWN BOVERI ABB Relays Abstract Application Instantaneous or definite­ time electromechanical ac overcurrent relay assemblies (RXIL 23, 24) • Single-phase, tw o-phase or three-phase overcurrent or ground-fault protection • Type RXIL 23 or 24 relay module used for
    OCR Scan PDF
    b03-2016
    Jinn m m B03-2016 __________ ASEA BROWN BOVERI ABB Relays Page Single-phase therm al overload relay assem b ly (RVAB) Data subject to change without notice • High accuracy • Thermal replica of protected object Abstract Application Design Type RVAB , • 8 -1 2 0 minutes time constant
    OCR Scan PDF
    b03-3210
    Ik » 1 1 Type RXZF21 f | | | | B03-32106 r Pagel Single-phase im pedance relay ASEA BROWN BOVERI ABB Relays Data subject to change without notice r) CANCELLED ' Abstract - . •■‘ 1 « • « • if . ' I • Jumper selectable circular or oval operat­
    OCR Scan PDF
    4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û
    4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û a tB R F R , December 19S3 ABB Refays IjîFû'Nd. RK 511-300 E fie g . P ag« 5625 1 Edition i Directional relay type R X PE k o Single phase directional current relay using voltage reference o Different current ranges available for operate values from 3 nriA
    OCR Scan PDF
    rxidf 2h
    A i m F l I P I P ” — A SEA B R O W N B O V E R I . AC tim e-overcurrent relay assem blies (RXIDF 2H) B03-2211E S T ,,» Charmed since October 1985 D a ta lu b ,ect to change without notice ABB Relays (8 00894) Abstract Application • Type RXIDF 2H relays used for currentmeasuring function
    OCR Scan PDF
    reb500
    Numerical Station Protection System REB500 / REB500sys 1MRB520308-Ben Busbar Protection with integrated Breaker Failure, Line and Transformer Protection Page 1 Issued: December 2008 Changed since October 2007 Data subject to change without notice REB500sys - Station protection with distributed architecture
    Original PDF
    reg216
    Numerical Generator Protection REG216 / REG216 Classic 1MRB520004-Ben Page 1 Issued: May 2005 Changed since: January 2005 Data subject to change without notice REG216 System Features • Modular hardware • Display of measured values • Selectable protection functions
    Original PDF
    be1-50/51b-219
    BE1-50/51B BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS BE1-50/51B in S1 Case BE1-50/51B-219, 226 CO Retrofit BE1-50/51B-214, 225 IAC Retrofit The BE1-50/51B Time Overcurrent Relay provides economical overload and fault protection for generators, transformers, lines and motors.
    Original PDF
    1 User’s Guide contents 2 Introduction 3
    1 User’s Guide contents 2 Introduction 3 Installation 4 General functions 5 Protection functions 6 Control functions 7 Monitoring functions 8 Index 9 Diagrams ABB Network Partner AB User’s Guide REC 561 Bay level control terminal 1MRK 511 009-UEN Version 1.0-00
    Original PDF
    reg316
    Numerical generator protection REG316*4 1MRK502004-Ben Page 1 Issued: February 2002 Changed: since December 1999 Data subject to change without notice Features • Selectable protection functions • Multitude of applications • Setting menu-assisted with personal computer by means of the Windows-based
    Original PDF
    rec316
    Numerical control and protection unit REC316*4 1MRK511016-Ben Page 1 Issued: February 2002 Changed: since December 1999 Data subject to change without notice Features Application • MV and HV systems for power transmission and distribution and for the power
    Original PDF
    ABB Solutions Low Voltage Products & Systems
    ABB Solutions Low Voltage Products & Systems Industrial Controls Contactors Overload Relays Starters Electronic Motor Protectors Manual Motor Protectors Miniature Controls Softstarters & Electronic Brakes Liquid Level Controls Electronic Timers / Controls, Flashers
    Original PDF
    s
    Pro M Miniature circuit breakers General information General information CSA C22.2 Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard
    Original PDF
    Line distance protection terminal REL 501*2.0
    Line distance protection terminal REL 501*2.0 1MRK 606 002-BEN Page 1 Issued May 2002 Changed since October 1998 Data subject to change without notice (SE 95 02 07) Features • Line distance functionality comprises; - simultaneous measurement of the different phase - phase impedances within
    Original PDF
    ABB string inverters Solar inverters ABB string
    ABB string inverters Solar inverters ABB string inverters UNO-2.0/2.5-I-OUTD UNO-2.0/2.5-I-OUTD 2 to 2.5kW kW 2 to 2.5 The UNO-2.0-I and UNO-2.5-I are packed with ABB’s proven high performing technology. The smallest of ABB’s outdoor range, these products are the right size for the
    Original PDF
    rxidf
    Type RXIDF a n d RXIDG 1MDB09005-EN Tim e-overcurrent_relays and _, protection 3SSGmbll6S E SS,'.«* Changed since August 1990 Data subject to change without notice ABB Network Control & Protection Features Application RXIDG 2H RXIDF 2H Three-phase OC assembly
    OCR Scan PDF
    Numerical Line Protection REL316*4 1MRK506013-Ben Page 1 Issued: May 2003 Changed: since February 2002 Data subject to change without notice Features Application • MV and HV systems with distance or longitudinal differential protection as main protection as well as combined in a terminal
    Original PDF
    Solar inverters ABB string inverters
    Solar inverters ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kW This isolated inverter is optimized for use in residential applications requiring PV array grounding, such as some thin-film modules. This inverter has also been designed to serve all countries and regions with specific
    Original PDF
    razoa
    ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se­ quential measurement distance relay for overhead lines and cables • Independent X and R reach settings
    OCR Scan PDF
    ret316
    Numerical transformer protection RET316*4 1MRK504007-Ben Page 1 Issued: February 2002 Changed since: December 1999 Data subject to change without notice Features • One three-phase differential function for two- or three-winding transformers • No interposing CTs
    Original PDF
    rel 551
    ~ction pervision munication vith REL 551 * 1.2 1MRK Line differE~ntial protection OOS-BEN Page 1 terminal November 1997 Changed since October Data subject to change 1997 without nariGe ABB Network Partner (SE 95 02 13) Features .Phase segregateclline differential protection
    Original PDF
    REL 517 Line protection terminal for railway
    REL 517 Line protection terminal for railway systems 1MRK 506 017-BEN Page 1 Issued August 1998 Changed since July 1998 Data subject to change without notice (SE970142) Features • Complete line protection terminal for railway systems • Intended for both catenary- and line
    Original PDF
    rel 561
    - REL 561 * 1.2 Line differential 1MRK 506 006-BEN Pan" 1 November 1997 Changed since October 1997 Dala subjecI lo change without nolice protec:tion terminal ABB Network Partner (SE 95 02 12) Features .Phase segregated line differential protection .Current differential measurement evaluating
    Original PDF
    radss
    Ä, AS'i Type RADSS K i v .. 8 fiW ,‘-f %gä? 1MDB05003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice Busbar protection ABB Network Control & Protection (810258) I (810260) Features Application (880568) • Percentage restraint bus differential relay
    OCR Scan PDF