Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ABB PHASE CON Search Results

    ABB PHASE CON Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-54RJ45UNNE-001
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-001 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 1ft PDF
    MP-54RJ45UNNE-002
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-002 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 2ft PDF
    CN-ACPRREDAA0
    Amphenol Cables on Demand RCA Male Plug Cable Connector (Red) - Amphenol ACPR-RED - Gold Plated Diecast Shell PDF
    CN-AC3MMDZBAU
    Amphenol Cables on Demand 3-Pin XLR Male Panel Mount Connector - Amphenol AC3MMDZB-AU - Solder Type (Black + Gold Contacts) PDF
    CN-DSUB25PIN0-000
    Amphenol Cables on Demand Amphenol CN-DSUB25PIN0-000 D-Subminiature (DB25 Male D-Sub) Connector, 25-Position Pin Contacts, Solder-Cup Terminals PDF

    Documents mentioning ABB PHASE CON

    Document Partial File Text Tags Type PDF
    cewe
    MINI Meter Single phase energymeter from ABB Cewe MINI Meter General description ABB Cewe’s MINI Meter is a single-phase active energy meter for applications that do not demand a certified meter. It is a robust meter with LED display that can be read even
    Original PDF
    razoa
    ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se­ quential measurement distance relay for overhead lines and cables • Independent X and R reach settings
    OCR Scan PDF
    reverse power relay
    ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current
    OCR Scan PDF
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three
    ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three phase overcurrent and ground-fault relay independent of auxiliary power supply B03-2314E Page 1 January 1989 Changed since January 1987 Data subject to change without notic (860567; Abstract Overcurrent and ground-fault protection
    OCR Scan PDF
    Phase Control and Bi-directionally Controlled
    Phase Control and Bi-directionally Controlled Thyristors ABB Switzerland Ltd, Semiconductors The work-horse of power conversion remains vital and is ready to conquer new applications and setting new power records. Since its introduction in the 1960s, the phase control thyristor
    Original PDF
    2610e
    F lI P I»I19 ASEA BROWN BOVERI ABB Relays Abstract B03-2610E Positive phase-sequence time-undervoltage relay assembly (RXODB 4) • Measures positive-phase-sequence vol­ tage • Inverse-time characteristic with definiteminimum time • Operate value continuously adjustable 0.4
    OCR Scan PDF
    rxig 21
    A IIII | l | | l l ASEA BROWN BOVERI Instantaneous or definitetime ac overcurrent relay assemblies (RXIG 21, 22, 28) B03-2035E ^ ; 1989 Data subject to change without notice ABB Relays (830504) Abstract Application • Single-phase, two-phase or three-phase
    OCR Scan PDF
    rxpe 4
    JF\MPIP ______________________ ■…• __________ aseabrownboveri Directional overcurrent and B03-3020 ABB Relays Abstract Application ground-fault relay assemblies (RXPE 42, 47 and RXPF 4) <Two-phase or three-phase directional over­ current protection for cables and overhead
    OCR Scan PDF
    rxil 2
    A S p Sp ASEA BROWN BOVERI ABB Relays Abstract Application Instantaneous or definite­ time electromechanical ac overcurrent relay assemblies (RXIL 23, 24) • Single-phase, tw o-phase or three-phase overcurrent or ground-fault protection • Type RXIL 23 or 24 relay module used for
    OCR Scan PDF
    gs-d250m
    * 7#» SGS-THOMSON GS-D250M 2.5A MICROSTEP DRIVE BOARD FOR STEPPER MOTORS FEATURES ■ 2.5A/phase peak current ■ 5, 10, 25, 45, 90, 100, 127, microsteps/step selection ■ Full step selection possibility ■ User programmable phase current ■ Userprogram m abb phase current ripple
    OCR Scan PDF
    REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance
    REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance protection terminal ~ Page 1 November 199 Changed since Data subject lo ctober 1997 ange wilhout nolice ABB Network Partner (SE950207) Features .Simultaneous measurement of the different phase-phase loop impedances within the
    Original PDF
    razfe
    i l II II aseabrownboveri ABB Relays Abstract Application Type RAZFE Three-zone, phase and ground distance relay for transm ission lines B03-7014E Page 1 SSySS.»», Datasubjecttochangewithoutnone. • Complete simultaneous measurement three-zone, phase and ground distance re­
    OCR Scan PDF
    Phase Control and Bi-directionally Controlled
    Phase Control and Bi-directionally Controlled Thyristors ABB Semiconductors The work-horse of power conversion Since its introduction almost 50 years ago, the Phase Control Thyristor has been the back-bone of the high power electronics industry. Its field of application ranges from kW DC-drives
    Original PDF
    fuse failure relay
    fM P IP ASEA BROWN BOVERI ABB Relays Abstract Type RXETA 1 B03-8311E Page 1 January 1985 Data subject to change without notice Fuse failure relay for threephase systems Operates at one- or two-phase fuse failures Two mercurywetted transfer contacts Not phase-sequence dependent
    OCR Scan PDF
    racid
    it m i ASEA BROWN BOVERI ABB Relays Type RACID Micro processor based timeovercurrent and ground fault relay B03-2312 Page 1 January 1989 Changed since October 1986 Data subject to change without notice (SE900263) General Application • Two-phase or three-phase time-overcurrent
    OCR Scan PDF
    abb drives
    ;A B B DRIVES 24E D ABB Drives------------------------------------ ■ DDlLaSS □□□□□□4 5 ■ — , --------------------- ’ TH YRISTO RS — Phase controlled thyristors / TH YRISTO REN - Netzthyristoren ^ TH YRISTO RS —Thyristors 3 Qommutation pane reseau
    OCR Scan PDF
    razfe
    Type RAZFE ÂSEA 8ROWN BOVE Hi Three-zone, phase and earth distance relay for transmission lines ~ 1MDB06018-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (820575) Features Application
    OCR Scan PDF
    b03-2611
    A Slip ASEA BROWN BOVERI Type RXOTD 4 B03-2611E Page 1 January 1987 Three-phase undervoltage relay Changed since January 1985 Data subject to change without notic ABB Relays Abstract s' • Used in networks with or without neutral • Operates for single-, two-, or three-phase
    OCR Scan PDF
    Type RE L 100/RELZ 100 ~ .., .~ 1MPBO600~EN ~
    Type RE L 100/RELZ 100 ~ .., .~ 1MPBO600~EN ~ page March 992 Chan since August 1990 Data s bject to change wilhoul nolice Line protection ABB Network Controi & Protection (90642) Features Application -Simultaneous phase and earth distance measurement with individual numerical
    Original PDF
    razfe
    Inlo-No. ABB INFORMATION RK G13~30Û E From/Date Reg. ÏÏFR, November 1979 Edition 5 À-SÊA B R O W N S C - Y fR r ABB Relays Raya 7^33 1 File EK 00-90 E sectio n o Distance relay type RAZFel ASÉA; s-rsi 9Î V5&t$rô& Swiden o Static three-phase design
    OCR Scan PDF
    rxidf
    Type RXIDF a n d RXIDG 1MDB09005-EN Tim e-overcurrent_relays and _, protection 3SSGmbll6S E SS,'.«* Changed since August 1990 Data subject to change without notice ABB Network Control & Protection Features Application RXIDG 2H RXIDF 2H Three-phase OC assembly
    OCR Scan PDF
    rel 511
    REL 511 * 1.2 1 MR~ 506 002-BEN Line distance protection terminal ~ Page 1 November 1 7 Changed si October 1997 Dala subject Ichange wilhoul nolice ABB Network Partner (SE 95 02 08) - Features .Simultaneous measurement of the different phase-phase and ph ase-earth loop impedances
    Original PDF
    abb semiconductors
    Phase Control Thyristors ABB Semiconductors AG I II V DSM •t a v m < t y p e and ordering n um ber Patentierter freier Druckkontakt. Ausgelegt für Hochleistungsanwendungen in der Industrie und Energieübertragung. Optimiert für tiefe Durchlaßspannungen.
    OCR Scan PDF
    razog
    V Al l i l i A* IP IP ASEA BROWN BOVERI ABB Relays Type RAZOG B03-7013E Three-zone, phase and ground distance relay for transmission lines Abstract Application Data subject to change without notice >Three-phase and ground sequential mea­ surement distance relay for overhead lines
    OCR Scan PDF
    Type RACIF ASEA BROWN BGVERI 1MDB07007-EN Phase
    Type RACIF ASEA BROWN BGVERI 1MDB07007-EN Phase and neutral overcurrent protection independent of auxiliary supply Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB N etw ork Control & Protection (SE 90632) Features Application
    OCR Scan PDF