A41 TRANSFORMER Search Results
A41 TRANSFORMER Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TUSS4440TRTJT |
![]() |
Transformer drive ultrasonic sensor IC with logarithmic amplifier |
![]() |
![]() |
|
ISO1176TDWR |
![]() |
Isolated ProfiBus Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
![]() |
![]() |
|
ISO3086TDWR |
![]() |
Isolated 485 Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
![]() |
![]() |
|
ISO3086TDW |
![]() |
Isolated 485 Transceiver with integrated transformer driver 16-SOIC -40 to 85 |
![]() |
![]() |
|
SN6501QDBVRQ1 |
![]() |
Automotive low-noise 350-mA, 410-kHz transformer driver 5-SOT-23 -40 to 125 |
![]() |
![]() |
A41 TRANSFORMER Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
EN60742
Abstract: EN60950
|
Original |
A41-061333-A000G A41-071140-A000G A41-081000-A000G A41-090700-A000G A41-100800-A000G A41-110727-A000G A41-120667-A000G A41-140700-A000G A41-150533-A000G A41-160250-A000G EN60742 EN60950 | |
Contextual Info: For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Which Require International Safety Certification Signal’s A41 triple output transformers have chassis mount capability plus ail of the performance features of our split bobbin A41 series. G en eral S p ecificatio n s |
OCR Scan |
4000VRMS Rati00" 24hrs) | |
a41-25-24
Abstract: SM 63A a41-175-24 A41-43-36 signal transformer a41-80-24 A41-130-24 lr51265
|
Original |
4000VRMS 24hrs) a41-25-24 SM 63A a41-175-24 A41-43-36 signal transformer a41-80-24 A41-130-24 lr51265 | |
Contextual Info: Series A41 International Power Transformers International High Power Transformers These transformers are built on dual bobbins with insulating shrouds to provide 4000V RMS isolation between primary and secondary. Non-concentric construction reduces primary-to-secondary |
Original |
E73539 | |
A41-80-20
Abstract: A41-25-24
|
OCR Scan |
4000VRMS 24hrs) A41-80-20 A41-25-24 | |
Transformer 115V 24V
Abstract: A41-25-24 A41-175-16 a41-175-24 A41-130-24 A41-80-28 A41-80-24 A41-80-36 A41-43-24 Transformer 230V 24V a41-43-24
|
Original |
UL94V-0 50/60Hz A41-130-28 A41-175-28 A41-25-36 A41-43-36 A41-80-36 A41-130-36 A41-175-36 Transformer 115V 24V A41-25-24 A41-175-16 a41-175-24 A41-130-24 A41-80-28 A41-80-24 A41-80-36 A41-43-24 Transformer 230V 24V a41-43-24 | |
PF20
Abstract: LM-340K-12 transformer 230v to 5v 2A 50 Hz LM340K-15 LM 555 National A41-25-512 A41-25-515 A41-43-512 A41-43-515 A41-80
|
Original |
115/230V PF20 LM-340K-12 transformer 230v to 5v 2A 50 Hz LM340K-15 LM 555 National A41-25-512 A41-25-515 A41-43-512 A41-43-515 A41-80 | |
Contextual Info: All-4-One International Triple Output Transformers • Chassis Mount SM For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Which Require International Safety Certification CV Part Number VA Size f Signal’s A41 triple output transformers have chassis mount capability |
Original |
4000VRMS 24hrs) | |
DIRIS A40
Abstract: transformador transformador 120 v a 24 v DIRIS C fonction iec 62053-21 3 FASE WIRE a40 diris 3NBL socomec iec 62053-21 kwh
|
Original |
A40/A41 DIRIS A40 transformador transformador 120 v a 24 v DIRIS C fonction iec 62053-21 3 FASE WIRE a40 diris 3NBL socomec iec 62053-21 kwh | |
Contextual Info: All-4-One International Triple Output Transformers - Chassis Mount SM For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Requiring International Safety Certification Triple output transformers with chassis mount capability plus all of the performance features of our split bobbin A41 series. |
Original |
115/230V | |
Contextual Info: A II-4 -O n e In t e r n a t io n a l T ra n s fo rm e rs C h a s s is M o u n t International Standards at Lower Cost and Better Performance Signal's A41 transformers provide the high isolation, creepage and clearance necessary to comply with international safety standards. |
OCR Scan |
4000VRMS 10VCT 24hrs) | |
HIGHWAY 09AContextual Info: Power Transformers .t o Recognized Component Underwriters Labs, Inc. INTERNATIONAL SERIES POWER TRANSFORMERS UL, VDE, IEC and C SA certified. In addition to being certified to VDE 0806, IEC 380, CSA 22.2 No. 66 and UL506, the EWC series of International Transformers is designed |
OCR Scan |
UL506, 175VA, RT25A HIGHWAY 09A | |
12A31
Abstract: abb voltage transformer 5P 5P GMT_G680LT1_SOT23_5P 20 kV Transformer dimensions
|
Original |
1VLC000515 12A31 abb voltage transformer 5P 5P GMT_G680LT1_SOT23_5P 20 kV Transformer dimensions | |
Contextual Info: one-4-all international MEETS UL, VDE, IEC, CSA AND ALL COST & BETTER PERFORMANCE THAN Part No. 14A-2.5-10 14A-5.0-10 14A-10-10 14A-20-10 14A-30-10 14A-56-10 14A-2.5-12 14A-5.0-12 14A-10-12 14A-20-12 14A-30*12 14A-56-12 14A-2.5-16 14A-5.0-16 14A-10-16 14A-20-16 |
OCR Scan |
4A-10-10 4A-20-10 4A-30-10 4A-56-10 4A-10-12 4A-20-12 4A-30 4A-56-12 4A-10-16 4A-20-16 | |
|
|||
Contextual Info: Selector Chart This selector chart was created to assist you in finding the corresponding page for the transformer needed for your application. How to use: • • • • • Select type of unit required, i.e. printed circuit, chassis mount, etc. Select power range more than one family may be available . |
OCR Scan |
UL1585, 241/DP241 12VDC 15VDC 12-1000m 24hrs) | |
Contextual Info: This selector chart was created to assist you in finding the corresponding page for the transformer needed for your application. How to use: • • • • • Select type of unit required, i.e. printed circuit, chassis mount, etc. Select power range more than one family may be available . |
OCR Scan |
UL1585, 12VDC 15VDC -120V 241/O 12V424V 12-1000m 24hrs) | |
ds04 nfc
Abstract: OS32GD12P 1SCA114581R1001 1SCA115641R1001 OS63GD12P OS125GD12P OS100GJ12P 1SCA114766R1001 1SCA115643R1001 1SCA115207R1001
|
Original |
networ28 FI-65101 OS10GB 1SCC311005B0201 ds04 nfc OS32GD12P 1SCA114581R1001 1SCA115641R1001 OS63GD12P OS125GD12P OS100GJ12P 1SCA114766R1001 1SCA115643R1001 1SCA115207R1001 | |
CPA4
Abstract: Jumper JP2e LEDTX CPD14 A41 transformer PCD-15 a4510 CPD11 MCS 96 users manual CPA17
|
Original |
DK86967 DK86967-ISA DK86967-PCC CPA4 Jumper JP2e LEDTX CPD14 A41 transformer PCD-15 a4510 CPD11 MCS 96 users manual CPA17 | |
transformer 15v 500mA
Abstract: 12v and 500ma transformer 51265 transformer 230v to 5v 2A 50 Hz lm 338 h lr51265 ic lm IC LM 320K PF20 transformer 15v 500mA datasheet
|
Original |
115/230V transformer 15v 500mA 12v and 500ma transformer 51265 transformer 230v to 5v 2A 50 Hz lm 338 h lr51265 ic lm IC LM 320K PF20 transformer 15v 500mA datasheet | |
Contextual Info: Class 2 Transformers PC BOARD MOUNT D esigned W ith T he S am e C o nstru ction As O ur 14A S eries Intern ational Transform ers. Isolation is 4000V. 7 115 /2 3 0 V 5 0 /6 0 H z DUAL P R IM A R IE S D in te n sio n s VA L W H 2.5 1 5/8 1 5/16 1 1/8 5.0 1 5/8 1 5/16 1 3/8 |
OCR Scan |
5-12B1 5-24B2 0-12B3 0-24B4 CL2-10-12B5 CL2-10-24B6 CL2-20-24B8 CL2-30-12B9 CL2-25-12A1 CL2-25-24A2 | |
Contextual Info: All-4-One International Transformers Chassis Mount SM International Standards at Lower Cost and Better Performance Designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. General Specifications |
Original |
94-V0 E66312 | |
signal transformer a41-80-24
Abstract: A41-130-24 a41-25-24 230V Transformer specification a41-175-16 Transformer a41-175-16 A41-80-24 a41-175-24 A41-80-36 A41-43-12 a41-43-36
|
Original |
94-V0 E66312 E63829 signal transformer a41-80-24 A41-130-24 a41-25-24 230V Transformer specification a41-175-16 Transformer a41-175-16 A41-80-24 a41-175-24 A41-80-36 A41-43-12 a41-43-36 | |
Contextual Info: Design and Construction Without Equal At Signal Transformer, we are committed to providing the highest grade magnetics for customers who demand total reliability, on-time delivery and competitive pricing. Year after year, independent brand preference studies |
OCR Scan |
24hrs) | |
Contextual Info: The Signal Way of Doing Business… Often imitated, but NEVER equalled At Signal Transformer, we are committed to providing the highest grade magnetics for customers who demand total reliability, on-time delivery and competitive pricing. Year after year, independent brand preference studies |
Original |
24hrs) |