| ade7752 | The World Leader in High Performance Signal Processing Solutions Three Phase Energy Metering IC with Pulse Output ADE7752 Energy Measurement Group Precision Converters (PRC) Division ADE7752 Overview 2 www.analog.com/energymeter a ADE7752 Overview • Surpasses IEC1036 Class 1 meter requirement. Less than 0.1% error |
Original | ||||
| FS6611<Preliminary> Energy Metering IC with | FS6611<Preliminary> Energy Metering IC with Impulse Output General Description z A PGA (Programmable Gain Amplifier) in the The FS6611 is a high accuracy electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC1036 |
Original | ||||
| iec1036 | a FEATURES 3-Phase, 4-Wire Metering IC High Accuracy Support for 50 Hz/60 Hz, IEC1036 Design Accuracy: 0.5% over 5% of Ib to 6% of Ib 0.65% over 2% of Ib to 5% of Ib Measures: kWh kW rms Voltage of Each Phase rms Current of Each Phase Phase and Nonlinearity Compensation for CTs |
Original | ||||
| PRELIMINARY TECHNICAL DATA a Energy Metering IC | PRELIMINARY TECHNICAL DATA a Energy Metering IC with Integrated Oscillator ADE7757* Preliminary Technical Data The ADE7757 specifications surpass the accuracy requirements as quoted in the IEC1036 standard. Due to the similarity between the ADE7757 and AD7755, the Application Note AN-559 can be used as a basis for a description of an IEC1036 low cost watt-hour meter reference |
Original | ||||
| ade7755 | a Energy Metering IC with Pulse Output ADE7755* The ADE7755 is a high accuracy electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC1036 standard. See Analog Devices’ Application Note AN-559 for a description of an IEC1036 watt-hour |
Original | ||||
| ade7757 | PRELIMINARY TECHNICAL DATA a Energy Metering IC with Integrated Oscillator ADE7757* Preliminary Technical Data The ADE7757 specifications surpass the accuracy requirements as quoted in the IEC1036 standard. Due to the similarity between the ADE7757 and AD7755, the Application Note AN-559 can be used as a basis for a description of an IEC1036 low cost watt-hour meter reference |
Original | ||||
| ad7755 | ANALOG ► DEVICES AD7755* f S E ii 50Hz/60Hz I EC 687/1036 g : £ , 4 500: 1 AD7755 0. 1% # H ^ ® i l 7 l E C l O 3 6 M ^ 0 t l ? H i j S ® ^ . W ^ : IEC1036 * A AD7755 31® FI *P F2 H w j s l a d i ^ / s ^ i g i s AN- 5 5 9 . ^ v m m m n tk k ^ m c F fi |
OCR Scan | ||||
| mcp3905a | MCP3905A/06A Evaluation Board User’s Guide © 2009 Microchip Technology Inc. DS51567B Note the following details of the code protection feature on Microchip devices: • Microchip products meet the specification contained in their particular Microchip Data Sheet. |
Original | ||||
| ad7751 | a FEATURES High Accuracy, Supports 50 Hz/60 Hz IEC 521/1036 Less than 0.1% Error Over a Dynamic Range of 500 to 1 The AD7751 Supplies Average Real Power On the Frequency Outputs F1 and F2 The High Frequency Output CF Is Intended for Calibration and Supplies Instantaneous Real Power Data |
Original | ||||
| Energy Data Converters Reduce Cost and Simplify | Energy Data Converters Reduce Cost and Simplify Meter Design Etienne Moulin, Analog Devices Presentation outline Introduction: Energy Metering requirements and Market Trend Energy Meter Architectures: Pros and Cons 1. Multi-Chip solution 2. Multi-Chip solution |
Original | ||||
| PRELIMINARY TECHNICAL DATA a Active and Apparent | PRELIMINARY TECHNICAL DATA a Active and Apparent Energy Metering IC with di/dt sensor interface Preliminary Technical Data ADE7753* FEATURES High Accuracy, supports IEC 61036 and IEC61268 On-Chip Digital Integrator enables direct interface with current sensors with di/dt output |
Original | ||||
| MSP430FE42x MIXED SIGNAL MICROCONTROLLER SLAS396A | MSP430FE42x MIXED SIGNAL MICROCONTROLLER SLAS396A − JULY 2003 − REVISED APRIL 2004 D Low Supply-Voltage Range, 2.7 V… 3.6 V D Ultralow-Power Consumption: D D D D D D D D D Brownout Detector D Supply Voltage Supervisor/Monitor With − Active Mode: 400 µA at 1 MHz, 3.0 V |
Original | ||||
| meter | METER COMPONENTS How solid is your solid-state energy meter? Not all ICs are created equal D id you know that the quality of an integrated circuit (IC) depends on the failure rate of the process it is manufactured from? Even if a device is fully functional, one made from a process with a |
Original | ||||
| energy meter | The World Leader in High Performance Signal Processing Solutions Energy Meter Seminar: Designing a EMC Compatible Electronic Meter using AD7755 http://www.analog.com/energymeter Design For Immunity to Electromagnetic Disturbances “the meter shall be designed in such a way |
Original | ||||
|
|
||||||
| ade77 | Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as |
Original | ||||
| ade7754 | The World Leader in High Performance Signal Processing Solutions Multi-functional Polyphase Energy Metering IC with Serial Port Interface ADE7754 Energy Measurement Group Precision Converters (PRC) Division ADE7754: A programmable solution for Polyphase Energy measurementTransducers |
Original | ||||
| an994 | AN994 IEC Compliant Active-Energy Meter Design Using The MCP3905A/06A Author: GOALS Craig L. King Microchip Technology Inc. OVERVIEW The MCP3905A/06A energy-metering Integrate Circuits (ICs) supply active real power measurements for single-phase residential meter designs. These |
Original | ||||
| ade7763 | Single-Phase Active and Apparent Energy Metering IC ADE7763 line-voltage period measurements, and rms calculation on the voltage and current channels. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as Rogowski coils, eliminating the need for an external analog |
Original | ||||
| ™ SALEM -1P SINGLE-PHASE ELECTRONIC ENERGY METER | ™ SALEM -1P SINGLE-PHASE ELECTRONIC ENERGY METER OVERVIEW HIGHLIGHTS Analog Devices’ SALEM-1P low-cost reference design for a microcontroller-based single-phase energy meter includes tamper detection and resistance. The design is based on an ADSST-EM-1010 |
Original | ||||