Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IEC1036 Search Results

    Documents mentioning IEC1036

    Document Partial File Text Tags Type PDF
    ade7752
    The World Leader in High Performance Signal Processing Solutions Three Phase Energy Metering IC with Pulse Output ADE7752 Energy Measurement Group Precision Converters (PRC) Division ADE7752 Overview 2 www.analog.com/energymeter a ADE7752 Overview • Surpasses IEC1036 Class 1 meter requirement. Less than 0.1% error
    Original PDF
    FS6611<Preliminary> Energy Metering IC with
    FS6611<Preliminary> Energy Metering IC with Impulse Output General Description z A PGA (Programmable Gain Amplifier) in the The FS6611 is a high accuracy electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC1036
    Original PDF
    iec1036
    a FEATURES 3-Phase, 4-Wire Metering IC High Accuracy Support for 50 Hz/60 Hz, IEC1036 Design Accuracy: 0.5% over 5% of Ib to 6% of Ib 0.65% over 2% of Ib to 5% of Ib Measures: kWh kW rms Voltage of Each Phase rms Current of Each Phase Phase and Nonlinearity Compensation for CTs
    Original PDF
    PRELIMINARY TECHNICAL DATA a Energy Metering IC
    PRELIMINARY TECHNICAL DATA a Energy Metering IC with Integrated Oscillator ADE7757* Preliminary Technical Data The ADE7757 specifications surpass the accuracy requirements as quoted in the IEC1036 standard. Due to the similarity between the ADE7757 and AD7755, the Application Note AN-559 can be used as a basis for a description of an IEC1036 low cost watt-hour meter reference
    Original PDF
    ade7755
    a Energy Metering IC with Pulse Output ADE7755* The ADE7755 is a high accuracy electrical energy measurement IC. The part specifications surpass the accuracy requirements as quoted in the IEC1036 standard. See Analog Devices’ Application Note AN-559 for a description of an IEC1036 watt-hour
    Original PDF
    ade7757
    PRELIMINARY TECHNICAL DATA a Energy Metering IC with Integrated Oscillator ADE7757* Preliminary Technical Data The ADE7757 specifications surpass the accuracy requirements as quoted in the IEC1036 standard. Due to the similarity between the ADE7757 and AD7755, the Application Note AN-559 can be used as a basis for a description of an IEC1036 low cost watt-hour meter reference
    Original PDF
    ad7755
    ANALOG ► DEVICES AD7755* f S E ii 50Hz/60Hz I EC 687/1036 g : £ , 4 500: 1 AD7755 0. 1% # H ^ ® i l 7 l E C l O 3 6 M ^ 0 t l ? H i j S ® ^ . W ^ : IEC1036 * A AD7755 31® FI *P F2 H w j s l a d i ^ / s ^ i g i s AN- 5 5 9 . ^ v m m m n tk k ^ m c F fi
    OCR Scan PDF
    mcp3905a
    MCP3905A/06A Evaluation Board User’s Guide © 2009 Microchip Technology Inc. DS51567B Note the following details of the code protection feature on Microchip devices: • Microchip products meet the specification contained in their particular Microchip Data Sheet.
    Original PDF
    ad7751
    a FEATURES High Accuracy, Supports 50 Hz/60 Hz IEC 521/1036 Less than 0.1% Error Over a Dynamic Range of 500 to 1 The AD7751 Supplies Average Real Power On the Frequency Outputs F1 and F2 The High Frequency Output CF Is Intended for Calibration and Supplies Instantaneous Real Power Data
    Original PDF
    Energy Data Converters Reduce Cost and Simplify
    Energy Data Converters Reduce Cost and Simplify Meter Design Etienne Moulin, Analog Devices Presentation outline „ Introduction: Energy Metering requirements and Market Trend „ Energy Meter Architectures: Pros and Cons 1. Multi-Chip solution 2. Multi-Chip solution
    Original PDF
    PRELIMINARY TECHNICAL DATA a Active and Apparent
    PRELIMINARY TECHNICAL DATA a Active and Apparent Energy Metering IC with di/dt sensor interface Preliminary Technical Data ADE7753* FEATURES High Accuracy, supports IEC 61036 and IEC61268 On-Chip Digital Integrator enables direct interface with current sensors with di/dt output
    Original PDF
    MSP430FE42x MIXED SIGNAL MICROCONTROLLER SLAS396A
    MSP430FE42x MIXED SIGNAL MICROCONTROLLER SLAS396A − JULY 2003 − REVISED APRIL 2004 D Low Supply-Voltage Range, 2.7 V… 3.6 V D Ultralow-Power Consumption: D D D D D D D D D Brownout Detector D Supply Voltage Supervisor/Monitor With − Active Mode: 400 µA at 1 MHz, 3.0 V
    Original PDF
    meter
    METER COMPONENTS How solid is your solid-state energy meter? Not all ICs are created equal D id you know that the quality of an integrated circuit (IC) depends on the failure rate of the process it is manufactured from? Even if a device is fully functional, one made from a process with a
    Original PDF
    energy meter
    The World Leader in High Performance Signal Processing Solutions Energy Meter Seminar: Designing a EMC Compatible Electronic Meter using AD7755 http://www.analog.com/energymeter Design For Immunity to Electromagnetic Disturbances “the meter shall be designed in such a way
    Original PDF
    ade77
    Single-Phase Multifunction Metering IC with di/dt Sensor Interface ADE7753 line-voltage period measurement, and rms calculation on the voltage and current. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as
    Original PDF
    ade7754
    The World Leader in High Performance Signal Processing Solutions Multi-functional Polyphase Energy Metering IC with Serial Port Interface ADE7754 Energy Measurement Group Precision Converters (PRC) Division ADE7754: A programmable solution for Polyphase Energy measurementTransducers
    Original PDF
    an994
    AN994 IEC Compliant Active-Energy Meter Design Using The MCP3905A/06A Author: GOALS Craig L. King Microchip Technology Inc. OVERVIEW The MCP3905A/06A energy-metering Integrate Circuits (ICs) supply active real power measurements for single-phase residential meter designs. These
    Original PDF
    ade7763
    Single-Phase Active and Apparent Energy Metering IC ADE7763 line-voltage period measurements, and rms calculation on the voltage and current channels. The selectable on-chip digital integrator provides direct interface to di/dt current sensors such as Rogowski coils, eliminating the need for an external analog
    Original PDF
    ™ SALEM -1P SINGLE-PHASE ELECTRONIC ENERGY METER
    ™ SALEM -1P SINGLE-PHASE ELECTRONIC ENERGY METER OVERVIEW HIGHLIGHTS Analog Devices’ SALEM-1P low-cost reference design for a microcontroller-based single-phase energy meter includes tamper detection and resistance. The design is based on an ADSST-EM-1010
    Original PDF