Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    71M6531 IC Search Results

    71M6531 IC Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TA75W393FU
    Toshiba Electronic Devices & Storage Corporation Comparator, Bipolar (393) type Dual Comparator, 2V to 36V, SOT-25 Datasheet
    TC75S59F
    Toshiba Electronic Devices & Storage Corporation Comparator, 1.8V to 7.0V, IDD=100μA, Open-drain output, SOT-25/SOT-353 Datasheet
    TA75S393F
    Toshiba Electronic Devices & Storage Corporation Comparator, Bipolar (393) type, 2V to 36V, SOT-25 Datasheet
    TC75S58F
    Toshiba Electronic Devices & Storage Corporation Comparator, 1.8V to 7.0V, IDD=10μA, Open-drain output, SOT-25/SOT-353 Datasheet
    TC75S70L6X
    Toshiba Electronic Devices & Storage Corporation Comparator, 1.3V to 5.5V, IDD=18μA, MP6C(1.0x1.45mm) Datasheet

    Documents mentioning 71M6531 IC

    Document Partial File Text Tags Type PDF
    71m6531
    71M6531 Demo Board QUICK START GUIDE Getting Started The TERIDIAN Semiconductor Corporation (TSC) 71M65131 Demo Board is a demonstration board for evaluating the 71M6531 IC for single-phase electronic energy metering applications on a two-layer PCB. It incorporates a
    Original PDF
    71m6531
    71M6531 Demo Board User’s Manual 71M6531 Demo Board USER’S MANUAL 6/2/2008 5:23:00 PM v1.5 TERIDIAN Semiconductor Corporation 6440 Oak Canyon Rd., Suite 100 Irvine, CA 92618-5201 Phone: (714) 508-8800 ▪ Fax: (714) 508-8878 http://www.teridian.com/ meter.support@teridian.com
    Original PDF
    71m653x
    71M653X Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_653X_016 December 2010 Field Download of Code to the 71M653x ICs This document describes three methods to reliably download code to a 71M6531, 71M6533 or 71M6534 ICs. Introduction
    Original PDF
    71m653x
    71M653X Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_653X_006 OCTOBER 2008 Code for Bank-Switching with the 653X-Series This document describes how to use banked code with a 71M6531. Similar principles apply for the 71M6533 and 71M6534.
    Original PDF
    71m6531
    71M6531/71M6533/71M6534 Energy Meter IC Family SOFTWARE USER’S GUIDE 5/8/2008 TERIDIAN Semiconductor Corporation 6440 Oak Canyon Rd., Suite 100 Irvine, CA 92618-5201 Ph: (714) 508-8800 ▪ Fax: (714) 508-8878 Meter.support@teridian.com http://www.teridian.com/
    Original PDF
    71m6531
    CT/SHUNT \ fW&Wi Ü LOAD NEUTRAL CT JB LOAD ■fSMW o ADC IAP* IAN* VA IBP* IBN* VB V3.3A V3.3 SYS TERIDIAN 71M6531 71M6532 GNDA GNDD PWR MODE CONTROL WAKE-UP REGULATOR VBAT V2.5 Ì VOLTAGE REF VREF VBIAS SERIAL PORTS TX TEMP SENSOR IR POWER FAULT TX/D I02
    OCR Scan PDF
    71m65xx
    71M65XX Energy Meter ICs A Maxim Integrated Products Brand Application Note AN_65XX_044 JANUARY 2011 Meter Design for Power Failure Events This document describes hardware and firmware methods that can be used in TERIDIAN meter chips to cope with sag and power-failure events. The sample code discussed in this Application Note was written for the Demo
    Original PDF
    teridian
    Metering IC Solutions Four Generations of Energy Meter SOC Ingenuity Empowering the Next Generation Teridian’s solutions for energy metering are comprised of a wide array of system-on-ship (SOC) devices which provide a highly accurate, reliable, and cost effective alternative to multi-chip implementations. Teridian’s
    Original PDF
    71m653x
    71M65xx Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_65XX_018 APRIL 2011 The SPI Interfaces of the 71M65xx Introduction Both the 71M653x and 71M654x families of electricity metering ICs offer SPI interfaces. These interfaces are described only briefly in the data sheets.
    Original PDF
    71m6531
    71M6531D/F, 71M6532D/F Energy Meter IC Simplifying System IntegrationTM DATA SHEET October 2009 GENERAL DESCRIPTION FEATURES The Teridian 71M6531D/F and 71M6532D/F are highly integrated SOCs with an MPU core, RTC, FLASH and LCD driver. Teridian’s patented Single Converter Technology® with a 22-bit
    Original PDF
    metering
    Meet Worldwide Metering Requirements Fourth-Generation SoCs Accelerate Meter Certification With four generations of metering SoCs and more than 50M units shipped to date, Maxim’s metrology products are found at the heart of the world’s most trusted energy meters. Our energy metering portfolio comprises a wide array of system-on-chip (SoC) devices
    Original PDF
    71m65xx
    71M65XX Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_65XX_061 OCTOBER 2009 Teridian 71M65XX Using DC-Tolerant CTs by J&D Electronics Introduction DC-tolerant CTs are gaining importance in the metering marketplace. As compared to general-purpose CTs, DCtolerant CTs have a much larger phase angle and can also be less linear than general-purpose CTs at low currents. J&D Electronics Co Ltd, Korea, has introduced a series of DC-tolerant CTs that can be successfully used
    Original PDF
    71m6532
    71M6531D/F, 71M6532D/F Energy Meter IC Simplifying System Integration TM DATA SHEET 19-5374; Rev 1; 4/13 GENERAL DESCRIPTION FEATURES The 71M6531D/F and 71M6532D/F are highly integrated SOCs with an MPU core, RTC, FLASH and LCD driver. The patented Single Converter Technology® with a
    Original PDF
    71m65xx
    71M65xx A Maxim Integrated Products Brand APPLICATION NOTE AN_65XX_045 FEBRUARY 2011 Power Monitoring Applications Introduction Monitoring momentary power and energy use becomes increasingly important in data centers, industrial equipment, power distribution units (PDUs), household appliances and other applications.
    Original PDF
    71m6531
    71M6531D/F, 71M6532D/F Energy Meter IC Simplifying System IntegrationTM DATA SHEET June 2010 GENERAL DESCRIPTION FEATURES The Teridian 71M6531D/F and 71M6532D/F are highly integrated SOCs with an MPU core, RTC, FLASH and LCD driver. Teridian’s patented Single Converter Technology®
    Original PDF
    71m65xx
    71M65XX A Maxim Integrated Products Brand APPLICATION NOTE AN_65XX_063 OCTOBER 2009 A Low-Current Power Supply for the 71M65XX Metering ICs Introduction Capacitor-coupled power supplies have been used for a long time in low-cost residential single-phase meters.
    Original PDF
    71m65xx
    71M65XX Energy Meter ICs A Maxim Integrated Products Brand Application Note AN_65XX_063 APRIL 2011 A Low-Current Power Supply for the 71M65XX Metering ICs Introduction Capacitor-coupled power supplies have been used for a long time in low-cost residential single-phase meters.
    Original PDF
    71m653x
    71M653X Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_653X_005 JANUARY 2009 Operating the 71M653X with External Serial SRAM Introduction This Application Note demonstrates methods for extending the internal 4KB XRAM of the 71M653X Energy
    Original PDF
    71m651x
    71M651x Energy Meter ICs A Maxim Integrated Products Brand APPLICATION NOTE AN_651X_009 MAY 2010 Temperature Compensation for the 71M651x/651xH, 71M652x, and 71M653x Energy Meter ICs Meters based on the 71M6511H, 71M6513H, 71M6533H, and 71M6534H are expected to be accurate within
    Original PDF
    71m653x
    71M653X A Maxim Integrated Products Brand APPLICATION NOTE AN_653X_003 AUGUST 2010 RTC Compensation Introduction This document describes methods to create an accurate real time clock (RTC) using the 653X-family Teridian Energy Meter ICs. The sample code discussed is from the released Demo Code for the 71M6533, but similar
    Original PDF
    71m653x
    71M653X A Maxim Integrated Products Brand APPLICATION NOTE AN_653X_003 JUNE 2011 RTC Compensation Introduction This document describes methods to create an accurate real time clock (RTC) using the 71M653x-family Teridian Energy Meter ICs. The sample code discussed is from the released Demo Code for the 71M6533, but similar
    Original PDF
    71m65xx
    71M65XX A Maxim Integrated Products Brand APPLICATION NOTE AN_65XX_057 JUNE 2009 Programming Teridian Meter ICs This Application Note describes interfaces, tools, precautions, and processes that are to be used for programming the flash memories of the Teridian 71M651X, 71M652X, and 71M653X Energy Meter ICs.
    Original PDF