60947-2 MAX Search Results
60947-2 MAX Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| HM2HN1P215LF | Amphenol Communications Solutions | Millipacs Accessories,Shrouds for Type A for 15.4 mm Max, Press Fit Header,ROHS Compliant | |||
| HM2HN1P209LF | Amphenol Communications Solutions | Millipacs Accessories,Shrouds for Type A for 15.4 mm Max, Press Fit Header,ROHS Compliant | |||
| HM2HN1P222LF | Amphenol Communications Solutions | Millipacs Accessories,Shrouds for Type A for 15.4 mm Max, Press Fit Header,ROHS Compliant | |||
| HM2HN2P109LF | Amphenol Communications Solutions | Millipacs Accessories,Shrouds for Type B for 15.4 mm Max, Press Fit Header,ROHS Compliant | |||
| HM2HN2P115LF | Amphenol Communications Solutions | Millipacs Accessories,Shrouds for Type B for 15.4 mm Max, Press Fit Header,ROHS Compliant |
Documents mentioning 60947-2 MAX
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| circuit-breakers | I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| circuit-breakers | I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| iec 60439-1 | TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control (1) 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K |
Original | ||||
| tesys | Characteristics, references TeSys enclosed starters 2 2 Star-delta starters (1) 7.5 to 75 kW with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Degree of protection conforming to IEC 60529 Ambient air temperature |
Original | ||||
| contactors mc | Contactors MC-Series Contactor 3 Pole UL508 E108780 Standards and Certifications • UL508 • IEC 60947-2 & IEC 60947-4-2 • CSA C22.2 No.14 Features • 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug Terminals Available) |
Original | ||||
| circuit-breakers | I12_004-005_b_G.fm Seite 4 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| Manual Motor Starters UL508 Type E MMS Series | Manual Motor Starters UL508 Type E MMS Series UL508 Type E E252942 Manual Motor Starters Standards and Certifications • UL508 (Manual Motor Controller) • UL508 (Type E self-protected Manual Motor Controller) • CSA C22.2 No.14 • IEC 60947-2 & IEC 60947-4-2 |
Original | ||||
| Limit Switches Osiswitch® Miniature, Metal | Limit Switches Osiswitch® Miniature, Metal Universal, XCMD Environment characteristics Conforming to standards Products Machine assemblies IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14 IEC 60204-1, EN 60204-1 Product certifications Protective treatment |
Original | ||||
| 60947 | 22100_Ver2.00-EN.backup.fm Page 2 Thursday, October 25, 2001 4:40 PM Characteristics Contactors Mini-contactors types LC1-SK and LP1-SK Environment Rated insulation voltage (Ui) 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508 |
Original | ||||
| Type: T0−2−15452/E Article No.: 091062 Front IP | Type: T0−2−15452/E Article No.: 091062 Front IP 65 Ordering information Design Flush mounting Pole 2 Contact sequence Front plate no. General IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch−disconnectors to IEC/EN 60947−3 Load−break switches to |
Original | ||||
| en 60947-4-1 | 22103 Page 10 Thursday, October 25, 2001 4:50 PM Characteristics Contactors Mini-contactors type LC1-SKGC for use in modular panels Environment Rated insulation voltage (Ui) 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508 |
Original | ||||
| iec 337-1 | Control Stations - Plastic Emergency Stop General Characteristics: Products Control stations Reference standard IEC 60947-5-1, EN 60947-5-1, IEC 337-1, UL 508, CSA C-22-2 n° 14 Approval Protection degree IP 65/IP 66 (as per IEC), NEMA 4/4X (special version) |
Original | ||||
| Characteristics 5 Control and signalling units 5 | Characteristics 5 Control and signalling units 5 Emergency stop trip wire switches, type XY2 C Environment Conformity to standards Products XY2 CB: IEC/EN 60947-5-1, CSA C 22-2 n° 14 (when specified) XY2 CE, CH: IEC/EN 60947-5-1, EN 418, UL 508 and CSA C 22-2 n° 14 (when specified) |
Original | ||||
| p2hz | Two-hand Relays EN 574, Type IIIC P2HZ 5, P2HZ 6 Technical Details Electrical Data Supply Voltage Tolerance Power Consumption Voltage and Current at the Input Circuits 1/2 Switching capability in accordance with EN 60947-4-1, 10/91 EN 60947-5-1, 10/91 (DC13: 6 cycles/min.) |
Original | ||||
|
|
||||||
| p2hz | Two-hand Relays EN 574, Type IIIC P2HZ 5, P2HZ 6 Technical Details Electrical Data Supply Voltage Tolerance Power Consumption Voltage and Current at the Input Circuits 1/2 Switching capability in accordance with EN 60947-4-1, 10/91 EN 60947-5-1, 10/91 (DC13: 6 cycles/min.) |
Original | ||||
| Characteristics 5 Safety dialogue solutions | Characteristics 5 Safety dialogue solutions Emergency stop trip wire switches, type XY2 C Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n° 14 (with suffix H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006, CSA C 22-2 n° 14 (with suffix H2) |
Original | ||||
Contents Loading… Cutler-Hammer Moulded Case Circuit Breakers 16-2500 Amperes for IEC 60947-2 Applications February 2001 Cutler-Hammer Frame Sizes G through R Contents Page Standards… 1 General Information… 2-3 |
Original | |||||
| sirius 3r | SIRIUS 3R Überlastrelais 3RU1.4 Overload Relay Relais de surcharge EN 60947, IEC 947 Bestell-Nr./Order No.: 3ZX1012-0RU11-1DA1 RU-00329 RU-00328 RU-00330 Montageanleitung/Assembly Instructions 1 2 3 1 1 1 RU-00331 2 2 2 RU-00332 max. + 60 °C Hand A RU-00333 |
Original | ||||
| sirius 3r | SIRIUS 3R Überlastrelais 3RU1.3 Overload Relay Relais de surcharge EN 60947, IEC 947 Bestell-Nr./Order No.: 3ZX1012-0RU11-1CA1 RU-00340 RU-00339 RU-00341 Montageanleitung/Assembly Instructions 1 2 1 1 1 2 3 RU-00342 2 2 RU-00343 max. + 60 °C Hand 1 A RU-00344 |
Original | ||||
| Product group data DILEM4 General Standards and | Product group data DILEM4 General Standards and specifications IEC/EN 60947, VDE 0660, CSA, UL Maximum operating frequency Mechanical Ops./h 9000 Damp heat, constant, to IEC 60 068-2-3, Damp heat, cyclical, to IEC 60 068-2-30 Climatic proofing Ambient temperature |
Original | ||||
| 3rg6 | Ultraschall-Schranke 3RG6243-.. DIN EN 60947 Teil 5-2 Deutsch Betriebsanleitung Bestell-Nr.: 3ZX1012-0RG62-1AA1 Anwendungsbereich Beispiel 2: Lückenerkennung, Bild IIIb Flaschenzählung Flaschen 0,33 l: Höhe: 23 cm, Durchmesser 6 cm Abstand zueinander: L > 0,35 cm |
Original | ||||
| sirius 3r | SIRIUS 3R Überlastrelais 3RU1.1 3RU1.2 Overload Relay Relais de surcharge EN 60947, IEC 947 Bestell-Nr./Order No.: 3ZX1012-0RU11-1AA1 RU-00207 RU-00208 Montageanleitung/Assembly Instructions RU-00200 3 3 1 1 3 2 2 Demontage RU-00202 A max. + 60 °C max. + 70 °C |
Original | ||||
| 3zx1012-0rt02-1aa1 | SIRIUS 3R Schütz 3RT1.2 Contactor Contacteur EN 60947, IEC 947 Bestell-Nr./Order No.: 3ZX1012-0RT02-1AA1 RT-00287 RT-00288 Montageanleitung/Assembly Instructions RT-00291 2 1 RT-00289 1 1 2 1 2 1 RT-00290 2 1 RT-00292 2 1 GWA 4NEB 507 0150-10 NC/NO: max. Stck. / pc. |
Original | ||||