Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    415V AND Search Results

    415V AND Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    AV-THLIN2BNCM-005
    Amphenol Cables on Demand Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft PDF
    CN-DSUB25PIN0-000
    Amphenol Cables on Demand Amphenol CN-DSUB25PIN0-000 D-Subminiature (DB25 Male D-Sub) Connector, 25-Position Pin Contacts, Solder-Cup Terminals PDF
    CN-DSUBHD26PN-000
    Amphenol Cables on Demand Amphenol CN-DSUBHD26PN-000 High-Density D-Subminiature (HD26 Male D-Sub) Connector, 26-Position Pin Contacts, Solder-Cup Terminals PDF
    CO-058BNCRBNC-010
    Amphenol Cables on Demand Amphenol CO-058BNCRBNC-010 BNC Male to BNC Right Angle Male (RG58) 50 Ohm Coaxial Cable Assembly 10ft PDF
    CO-058BNCX200-012
    Amphenol Cables on Demand Amphenol CO-058BNCX200-012 BNC Male to BNC Male (RG58) 50 Ohm Coaxial Cable Assembly 12ft PDF

    Documents mentioning 415V AND

    Document Partial File Text Tags Type PDF
    3 phase
    Star / Delta selections for 415v 3 phase motors Motor F.L.C. against power at 415v based on average typical motors Star / delta components for customer assembly Note: Star / delta kit includes timer, power connections and mechanical interlock Complete starters
    Original PDF
    o
    Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC… lth /A le /AC22A, ≤ 415V le /AC23A, ≤ 415V OT16F OT25F OT40F OT63F OT80F OT100F OT125F OT160E 25 32 40 16 25 40 16 20 23 63 80
    Original PDF
    distribution board
    Isobar 4 TP&N type B distribution boards - incomers Switch disconnectors Part No. MGI1253N MGI1254 Rating 125A 125A Voltage 415V 415V No of poles 3+N 4 Specification: ■ MGI1254 ■ BS EN 60947-3. Category of duty AC22. Positive contact indication in accordance with
    Original PDF
    ce E-Pack installation Instructions Starters Type
    ce E-Pack installation Instructions Starters Type EXS2-S and EXS2-SI Issue 1 Installation ie c 947 4-1 - Ratings 1. Remove cover by releasing catches with a screwdriver. Star-Delta 22kW 415V max. Coil voltages (50Hz) 240V 415V Recommended Approximate motor rating max. fuse
    OCR Scan PDF
    ot16f
    Low Voltage Switches Switches Switch-disconnectors Switch-disconnector IEC lth /A le /AC22A, ≤ 415V le /AC23A, ≤ 415V OT16F OT25F OT40F OT63F OT80F 25 32 40 63 80 16 25 40 63 80 16 20 23 45 75 OT100F OT125F OT160E 115 125 100 125 80 90 200 160 135 OT200E
    Original PDF
    Issued / Herausgegeben / Publicado / Publication
    Issued / Herausgegeben / Publicado / Publication Publicatto / Udgivet / Afgegeven / Utgiven 04/2002 V8721 0.5 to 10hp 415V Direct on Line Starter Direktstarter, 0,5-10 PS, 415 V Instruction Leaflet Bedienungsanleitung Hojas de instrucciones Feuille d’instructions
    Original PDF
    a9s60232
    Product data sheet Characteristics A9S60232 switch Acti9 iSW - 2 poles - 32 A - 415V Product or component type Switch Range of product ISW Device short name ISW Switch application Control Poles description 2P Utilisation category AC-22A Suitability for isolation
    Original PDF
    x10701
    200A HAC RANGE THYRISTOR POWER REGULATORS 200HAC SERIES X10701 INTRODUCTION The HAC range of Thyristor stacks is available for single and three phase 240/415V applications (other voltages can be accommodated). They control loads up to 200A, with a number of control options. They are assembled to
    Original PDF
    iec269
    Bussmann ® BS88, IEC269 Industrial HRC Fuse Links ED Centre Bolted Tags 415V and 550V ac 250 - 400 Amps Time-Current Characteristic Curves Non Motor Rated Motor Rated 315M400 400M500 Dimensional Data Centre Bolted Tag Catalog' Number I2t (Amps2 Seconds) Amp
    Original PDF
    Lubricated for life sintered bearings Ball
    Lubricated for life sintered bearings Ball bearings Precision die-cast bearing housings 4.76mm or 6mm steel shaft, stainless steel and other diameters to special order Voltage range 24 to 415V AC Insulation grade to class B Resetting or non-resetting thermal protection
    Original PDF
    bussmann
    Bussmann ® BS88, IEC269 CD Industrial HRC Fuse Links Centre Bolted Tags 550V ac and 415V ac Time-Current Characteristic Curves Non Motor Rated Motor Rated 80A 100A 100M125 100M160 100M200 Dimensional Data Centre Bolted Tag Catalog' Number CD80 CD100 I2t (Amps2 Seconds)
    Original PDF
    a9s60491
    Product data sheet Characteristics A9S60491 switch Acti9 iSW - 4 poles - 100 A - 415V Product or component type Switch disconnector Range of product ISW Device short name ISW Switch application Isolation Control Poles description 4P Utilisation category AC-22A conforming to EN 60947-3
    Original PDF
    a9s60263
    Product data sheet Characteristics A9S60263 switch Acti9 iSW - 2 poles - 63A - 415V Product or component type Switch disconnector Range of product ISW Device short name ISW Switch application Isolation Control Poles description 2P Utilisation category AC-22A conforming to EN 60947-3
    Original PDF
    bussmann
    Bussmann ® BS88, IEC269 Industrial HRC Fuse Links EF Centre Bolted Tags 415V ac and 550V ac for Motor Rated Time-Current Characteristic Curves Non Motor Rated Motor Rated Dimensional Data Centre Bolted Tag Catalog' Number I2t (Amps2 Secondsx 103) Nom. Rated
    Original PDF
    iec269
    BS88, IEC269 Bussmann® Industrial HRC Fuse Links OSD Offset Bolted Tags 550V ac and Motor Rated 415V Time-Current Characteristic Curves Motor Rated Non Motor Rated 80A 100A 100M125 100M160 Dimensional Data Offset Bolted Tag I t (Amps Seconds) Number OSD80
    Original PDF
    iec269
    Bussmann ® BS88, IEC269 Industrial HRC Fuse Links CEO Offset Bolted Tags 550V ac and Motor Rated 415V ac Time-Current Characteristic Curves Motor Rated Non Motor Rated 32A 40A 50A 63A 80A 100A 100M125 100M160 100M200 Dimensional Data Offset Bolted Tag Catalog'
    Original PDF
    C€ E-Pack Installation Instructions Starters Type
    C€ E-Pack Installation Instructions Starters Type EXS2-DI Issue 6 Installation ie c 947 4-1 - Ratings 1. Remove cover from starter by releasing catches with a screwdriver. Direct-On-Line up to 15kW 415V max. 2. Check operating coil voltage and frequency.
    OCR Scan PDF
    cpc5603c
    CPC5603C N Channel Depletion Mode FET Features • Low on resistance 8 ohms • Breakdown voltage 415V minimum • High input impedance • Low input and output leakage • Small package size SOT-223 • PC Card (PCMCIA) Compatible • PCB Space and Cost Savings
    Original PDF
    iec269
    Bussmann ® BS88, IEC269 Industrial HRC Fuse Links EFS Centre Bolted Tags 415V ac 125-315 Amps Time-Current Characteristic Curves Non Motor Rated Dimensional Data Centre Bolted Tag 2 hole 125-250A Catalog' Number EFS125 I2t (Amps2 Seconds) Nom. Rated Amp PreTotal at Watts Voltage
    Original PDF
    a9s60420
    Product data sheet Characteristics A9S60420 switch Acti9 iSW - 4 poles - 20 A - 415V Product or component type Switch Range of product ISW Device short name ISW Switch application Control Poles description 4P Utilisation category AC-22A Suitability for isolation
    Original PDF
    a9s60432
    Product data sheet Characteristics A9S60432 switch Acti9 iSW - 4 poles - 32 A - 415V Product or component type Switch Range of product ISW Device short name ISW Switch application Control Poles description 4P Utilisation category AC-22A Suitability for isolation
    Original PDF
    a9s60220
    Product data sheet Characteristics A9S60220 switch Acti9 iSW - 2 poles - 20 A - 415V Product or component type Switch Range of product ISW Device short name ISW Switch application Control Poles description 2P Utilisation category AC-22A Suitability for isolation
    Original PDF
    telemecanique gv2
    Telemecanique GV2-M and K range with spring terminals References GV2-M motor circuit breakers References GV2-M013 GV2-M023 GV2-M033 GV2-M043 GV2-M053 GV2-M063 GV2-M073 Power (kW) 400/415V <0.06 0.06 0.09 0.12 0.25 0.37 0.75 Rating (A) 0.1 - 0.16 0.16 - 0.25
    Original PDF
    382.073.468 3120-…-..T1-.. sheet 1 of 37 one and
    382.073.468 3120-…-..T1-.. sheet 1 of 37 one and two pole Replacing data sheet dated 382.073.468 24. Oct. 1997 Technical data to EN 60 934 Max.voltage rating Rated insulation voltage Current rating range AC 240V / DC 50 V, AC 415V AC 415 V 0.1… 20A 1 and 2 pole
    Original PDF