4-20MA TH Search Results
4-20MA TH Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| XTR101AU/1K | Texas Instruments | Precision, Low Drift 4-20mA Two-Wire Transmitter 16-SOIC -40 to 85 |
|
|
|
| XTR112U | Texas Instruments | 4-20mA Current Transmitters with Sensor Excitation and Linearization 14-SOIC |
|
|
|
| XTR116UA/2K5 | Texas Instruments | 4-20mA Current Loop Transmitters 8-SOIC -40 to 85 |
|
|
|
| XTR117AIDRBT | Texas Instruments | XTR117 4-20mA Current Loop Transmitter 8-SON -40 to 125 |
|
|
Documents mentioning 4-20MA TH
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| eps5544-1 | EPS5544-1 Hazardous area MTL5544 REPEATER POWER SUPPLY Safe area Ch 2 two channel, 4/20mA, smart, for 2- or 3- wire transmitters 6 4/20mA 4 3 2 1 + Ch 2 Load 4/20mA + Ch 1 Load 4/20mA + Vs Vs+ 13 14 Ch 1 20 to 35V dc Terminal SPECIFICATION Function |
Original | ||||
| Maxim > App Notes > INTERFACE CIRCUITS | Maxim > App Notes > INTERFACE CIRCUITS POWER-SUPPLY CIRCUITS Keywords: Power Supply From 4-20mA Transmission Line Jul 29, 2002 APPLICATION NOTE 1158 Power Supply From 4-20mA Transmission Line When using a 4-20mA two-wire transmission system, it is useful to steal power for the remote device directly |
Original | ||||
| dms-an-20 | Application Note www.murata-ps.com 4-20mA Current Loop Primer DMS-AN-20 Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA |
Original | ||||
| mtl4544 | MTL4544/S MTL4544/S – MTL5544/S REPEATER POWER SUPPLY 2-channel, 4/20mA, HART®, 2- or 3- wire transmitters Hazardous area Safe area MTL4544 Ch 2 + 6 5 4 I I 4/20mA The MTLx544 provides fully-floating dc supplies for energising two conventional 2-wire or 3-wire 4/20mA or HART transmitters located in |
Original | ||||
| 4-20ma current loop | Maxim/Dallas > App Notes > CIRCUIT PROTECTION INTERFACE CIRCUITS Keywords: 4-20mA current loop, fault protection, current limiting, current-sense amplifiers Apr 22, 2004 APPLICATION NOTE 3195 Add Fault Protection to 4-20mA Loop Supply This circuit provides flexible fault protection for a 4-20mA current loop. In addition, it includes circuitry for |
Original | ||||
| 3b10 | 3B Series I/O Subsystems I______________ I Input Module Selection Input Type/Span Voltage Output Current Output Nonisolated Modules Isolated Modules dc, ± lOmV, ± 50m V , ± lOOmV ±10V 4-20mA/0-20mA 3B10 3B30 dc, ± IV , ± 5V + 10V 4-20mA/0-20mA 3B10 3B31 |
OCR Scan | ||||
| ® DMS APPLICATION NOTE 4-20mA Current Loop Primer | ® DMS APPLICATION NOTE 4-20mA Current Loop Primer Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA current loops are used; |
Original | ||||
| 4-20ma | DSCL23 4-20mA Isolator with DC Supply DIN or Panel Mount FEATURES DESCRIPTION Á FEEDS DC POWER TO 4-20MA TRANSMITTER, Each DSCL23 loop powered isolator provides 1 or 2 channels of analog signal protection by electrically isolating its input from output for any DC process signal in the range 4-20mA. The |
Original | ||||
| Maxim > App Notes > A/D and D/A | Maxim > App Notes > A/D and D/A CONVERSION/SAMPLING CIRCUITS AMPLIFIER AND COMPARATOR CIRCUITS INTERFACE CIRCUITS SENSOR SIGNAL CONDITIONERS Keywords: 4-20mA transducers, 4-20mA translator, 4 to 20mA converter, A/D, ADC, a to d, analog digital, analog to digital converters, convertor |
Original | ||||
| Maxim > App Notes > A/D and D/A | Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Amplifier and Comparator Circuits Interface Circuits Sensors Keywords: 4-20mA transducers, 4-20mA translator, 4 to 20mA converter, A/D, ADC, a to d, analog digital, analog to digital converters, |
Original | ||||
| ad420 | ANALOG DEVICES Evaluation Board AD420 16-Bit 4-20mA DAC GENERAL DESCRIPTION The AD420-EB is an evaluation board for the AD420 16 bit serial input 4 - 20mA, 0 - 20mA DAC. The evaluation board is configured with two AD420s. Both devices are indepen dently controlled with an IBM PC or compatible, via its |
OCR Scan | ||||
| pcir101 | PCIR101 - PCIR102 SIGNAL CONDITIONER WITH VOLTAGE (101), CURRENT 4…20mA (102) OUTPUT FOR DISPLACEMENT TRANSDUCERS Main features • Interface module integrated in the connector • Standard output 0…10Vdc (PCIR 101) • Standard output 4…20mA(PCIR 102) |
Original | ||||
| inclinometer | SPECTROTILTtm ñ 4-20mA Electronic Inclinometer The SPECTROTILTtm 4-20mA Electronic Inclinometer is a fully signal conditioned, single axis tilt sensor. By combining a proprietary glass/ceramic hybrid electrolytic tilt sensor, with custom electronics, the SPECTROTILTtm rivals both the |
Original | ||||
| ACTIVE SIGNAL AMPLIFIER Iin &Iout | ACTIVE SIGNAL AMPLIFIER Iin &Iout T11/12/21/22_D/S DESCRIPTION PRODUCT PROGRAM The series is a high integration, high efficiency polygonal - line active isolation Part Number amplifier module, with anterior circuit current T1133D/S 24V 4-20mA 4-20mA 24V 1 |
Original | ||||
|
|
||||||
| dms-40pc | ® DMS-40PC-4/20S 4-20mA Input 4½ Digit Process Monitors with Full-Size LED Displays Order on-line at www.datel.com New +24V Isolated-Power Models Features The DMS-40PC-4/20S Series' superior design makes them ideal for use in demanding 4-20mA process monitoring applications requiring a full 4½ digits (0-19999) |
Original | ||||
| 4-20ma transmitter | Maxim > App Notes > MICROCONTROLLERS Keywords: MAXQ, microcontroller, current loop, process-monitoring Dec 22, 2005 APPLICATION NOTE 3653 MAXQ Microcontroller Drives a Smart and Intelligent 4-20mA Transmitter Abstract: The 4-20mA current loop is a common technique for transmitting sensor information in industrial |
Original | ||||
| ® DMS-40PC-4/20S 4-20mA Input 4½ Digit Process | ® DMS-40PC-4/20S 4-20mA Input 4½ Digit Process Monitors with Full-Size LED Displays New +24V Isolated-Power Models Order on-line at www.datel.com Features The DMS-40PC-4/20S Series' superior design makes them ideal for use in demanding 4-20mA process monitoring applications requiring a full 4½ digits (0-19999) |
Original | ||||
| DMS-30LCDA-4/20 Series Loop-Powered, 1.8V Drop, | DMS-30LCDA-4/20 Series Loop-Powered, 1.8V Drop, 4-20mA Process Monitors with Full-Size LCD Displays FEATURES Murata Power Solution’s new DMS-30LCDA-4/20 Series’ 1.8V nominal loop-drop is the lowest of any comparably priced, 4-20mA input, 3½-digit process monitors with full-size |
Original | ||||
| Data Sheet 2101107-AC Analog Output (AO) Module | Data Sheet 2101107-AC Analog Output (AO) Module (2100415) XSeries Products TFIO Module INTRODUCTION The 2100415 TFIO Module is a configurable 4 channel, 4-20mA analog output module. Each point can be configured to either sink or source a 4-20mA signal using either an internal or external power |
Original | ||||
| 4-20ma | ® DMS APPLICATION NOTE 4-20mA Current Loop Configurations and FAQ’s Introduction Since loop-powered process monitors must function accurately with currents between 4 and 20mA, low-power liquid crystal displays (LCD’s), similar to the type found in inexpensive hand-held calculators, |
Original | ||||