4-20MA CURRENT LOOP CONVERTER Search Results
4-20MA CURRENT LOOP CONVERTER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-QSFPLOOPBK-003 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] | |||
| SF-QSFPLOOPBK-002 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-002 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 0W Power Consumption [Copper+Optical Ready] | |||
| SF-SFPPLOOPBK-0DB | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption | |||
| SF-SFPPLOOPBK-003.5 | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation | |||
| SF-QSFPLOOPBK-001 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-001 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] |
Documents mentioning 4-20MA CURRENT LOOP CONVERTER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 4-20ma current loop | Maxim/Dallas > App Notes > CIRCUIT PROTECTION INTERFACE CIRCUITS Keywords: 4-20mA current loop, fault protection, current limiting, current-sense amplifiers Apr 22, 2004 APPLICATION NOTE 3195 Add Fault Protection to 4-20mA Loop Supply This circuit provides flexible fault protection for a 4-20mA current loop. In addition, it includes circuitry for |
Original | ||||
| xtr115 | BURR-BROWN XTR115 XTR116 For most current data sheet and other product information, visit www.burr-brown.com 4-20mA CURRENT LOOP TRANSMITTERS FEATURES APPLICATIONS • LOW QUIESCENT CURRENT: 200fiA • 5V REGULATOR FOR EXTERNAL CIRCUITS • 2-WIRE, 4-20mA CURRENT LOOP |
OCR Scan | ||||
| max1459 | Maxim > App Notes > SENSOR SIGNAL CONDITIONERS Keywords: 4-20mA loop, 2-wire interface, current loop, MAX1459, sensor signal conditioner May 01, 2002 APPLICATION NOTE 1064 Designing a 4-20mA Current Loop Using the MAX1459 Sensor Signal Conditioner Abstract: Current-mode data transmission is the preferred technique in many environments, particularly in |
Original | ||||
| XTR117 SBOS344C − SEPTEMBER 2005 − REVISED MAY | XTR117 SBOS344C − SEPTEMBER 2005 − REVISED MAY 2012 4-20mA Current-Loop Transmitter FEATURES DESCRIPTION D D D D D D The XTR117 is a precision current output converter designed to transmit analog 4-20mA signals over an industry-standard current loop. It provides accurate current scaling and output |
Original | ||||
| XTR117 SBOS344C − SEPTEMBER 2005 − REVISED MAY | XTR117 SBOS344C − SEPTEMBER 2005 − REVISED MAY 2012 4-20mA Current-Loop Transmitter FEATURES DESCRIPTION D D D D D D The XTR117 is a precision current output converter designed to transmit analog 4-20mA signals over an industry-standard current loop. It provides accurate current scaling and output |
Original | ||||
| sbos344c | XTR117 SBOS344C − SEPTEMBER 2005 − REVISED MAY 2012 4-20mA Current-Loop Transmitter FEATURES DESCRIPTION D D D D D D The XTR117 is a precision current output converter designed to transmit analog 4-20mA signals over an industry-standard current loop. It provides accurate current scaling and output |
Original | ||||
| xtr115 | ® XTR115 XTR116 XTR 116 XTR 115 For most current data sheet and other product information, visit www.burr-brown.com 4-20mA CURRENT LOOP TRANSMITTERS FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 200µA ● 2-WIRE, 4-20mA CURRENT LOOP TRANSMITTER ● 5V REGULATOR FOR EXTERNAL CIRCUITS |
Original | ||||
| xtr115 | ® XTR115 XTR116 XTR 116 XTR 115 For most current data sheet and other product information, visit www.burr-brown.com 4-20mA CURRENT LOOP TRANSMITTERS FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 200µA ● 2-WIRE, 4-20mA CURRENT LOOP TRANSMITTER ● 5V REGULATOR FOR EXTERNAL CIRCUITS |
Original | ||||
| xtr115 | ® XTR115 XTR116 XTR 116 XTR 115 For most current data sheet and other product information, visit www.burr-brown.com 4-20mA CURRENT LOOP TRANSMITTERS FEATURES APPLICATIONS ● LOW QUIESCENT CURRENT: 200µA ● 2-WIRE, 4-20mA CURRENT LOOP TRANSMITTER ● 5V REGULATOR FOR EXTERNAL CIRCUITS |
Original | ||||
| 4-20ma transmitter | Maxim > App Notes > MICROCONTROLLERS Keywords: MAXQ, microcontroller, current loop, process-monitoring Dec 22, 2005 APPLICATION NOTE 3653 MAXQ Microcontroller Drives a Smart and Intelligent 4-20mA Transmitter Abstract: The 4-20mA current loop is a common technique for transmitting sensor information in industrial |
Original | ||||
| 0-20ma | Maxim > App Notes > A/D and D/A CONVERSION/SAMPLING CIRCUITS AMPLIFIER AND COMPARATOR CIRCUITS SWITCHES AND MULTIPLEXERS Keywords: 4-20mA, 0-20mA, current loop, current loop transmission, DAC, V/I, V to I, converter, digital to analog converter May 31, 2002 |
Original | ||||
| 232cldr | Documentation Number 232CLDR0602 – pg. 1/4 DIN Rail Mountable RS-232 to Current Loop With Terminal Blocks Model 232CLDR The 232CLDR is a DIN rail mountable version of B&B’s RS-232 to current loop converter. This unit has one optically isolated 20mA transmit loop and one optically isolated 20mA receive |
Original | ||||
| 4-20ma | A/D and D/A CONVERSION/SAMPLING CIRCUITS VOLTAGE REFERENCES Application Note 1085: May 31, 2002 AMPLIFIER AND COMPARATOR CIRCUITS SWITCHES AND MULTIPLEXERS Selectable-Range Current Loop This article shows an example of implementing a 4-20mA or 0-20mA current-loop |
Original | ||||
| 4-20ma | ® DMS APPLICATION NOTE 4-20mA Current Loop Configurations and FAQ’s Introduction Since loop-powered process monitors must function accurately with currents between 4 and 20mA, low-power liquid crystal displays (LCD’s), similar to the type found in inexpensive hand-held calculators, |
Original | ||||
|
|
||||||
| ® DMS APPLICATION NOTE 4-20mA Current Loop | ® DMS APPLICATION NOTE 4-20mA Current Loop Configurations and FAQ’s Introduction Since loop-powered process monitors must function accurately with currents between 4 and 20mA, low-power liquid crystal displays (LCD’s), similar to the type found in inexpensive hand-held calculators, |
Original | ||||
| an1015 | Application notes AN1015 AM462 – How to convert a 0…5V input signal into a 4…20mA current loop output The task on hand An input signal of 0 to 5V is to be converted with sufficient accuracy (<0,5%FS) into an output current of 4 to 20mA for 2-wire application (current loop). |
Original | ||||
| ® DMS APPLICATION NOTE 4-20mA Current Loop Primer | ® DMS APPLICATION NOTE 4-20mA Current Loop Primer Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA current loops are used; |
Original | ||||
| The 4-20mA Current Loop Introduction It is now | The 4-20mA Current Loop Introduction It is now over 50 years since the 4-20mA current loop was introduced as a means of transmitting an analog signal in an industrial environment. Based on the fact that new silicon is still being designed, it appears to be holding its own against challenges from the |
OCR Scan | ||||
| dms-an-20 | Application Note www.murata-ps.com 4-20mA Current Loop Primer DMS-AN-20 Introduction This application note’s primary goal is to provide an easy-tounderstand primer for users who are not familiar with 4-20mA current-loops and their applications. Some of the many topics discussed include: why, and where, 4-20mA |
Original | ||||
| rcv420 | ® RCV420 Precision 4mA to 20mA CURRENT LOOP RECEIVER FEATURES APPLICATIONS ● COMPLETE 4-20mA TO 0-5V CONVERSION ● PROCESS CONTROL ● INTERNAL SENSE RESISTORS ● PRECISION 10V REFERENCE ● BUILT-IN LEVEL-SHIFTING ● INDUSTRIAL CONTROL ● FACTORY AUTOMATION |
Original | ||||