3-PHASE 230V Search Results
3-PHASE 230V Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TB6551FAG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=12/Sine Wave | Datasheet | ||
| TB6586FG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave | Datasheet | ||
| TB62213AFNG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=3/Phase Interface | Datasheet | ||
| TB62261FTG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.8/Phase Interface | Datasheet | ||
| TB67S141NG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Unipolar Type/Vout(V)=84/Iout(A)=3/Phase Interface | Datasheet |
Documents mentioning 3-PHASE 230V
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| sitop | SITOP Power Supplies Technical European Applications Only 6EP1336-1SH01 6EP1732-0AA00 6EP1437-1SL01 6EP1437-1SL11 SITOP Power Single-Phase/3-Phase Technical Specification Euro Line SITOP power DC 24V/2A Single-Phase 230V 24V/20A 3-Phase 400V 24V/30A 3-Phase 400V |
Original | ||||
| PRODUCT INDEX Line Interactive • Modified | PRODUCT INDEX Line Interactive • Modified Sinewave (T1) • Pure Sinewave (T2) Online Double Conversion • 1 Phase Input / 1 Phase Output (T3) • 3 Phase Input / 1 Phase Output (T4) • 3 Phase Input / 3 Phase Output (T5) Specialist Networking Distributor |
Original | ||||
| Three-phase Voltage Relay K8AB-PW | Three-phase Voltage Relay K8AB-PW CSM_K8AB-PW_DS_E_3_1 Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies. DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power |
Original | ||||
| Three-phase Phase-sequence Phase-loss Relay | Three-phase Phase-sequence Phase-loss Relay K8AB-PM CSM_K8AB-PM_DS_E_4_1 Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with |
Original | ||||
| Three-phase Phase-sequence Phase-loss Relay | Three-phase Phase-sequence Phase-loss Relay K8AB-PM CSM_K8AB-PM_DS_E_5_1 Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with |
Original | ||||
| phase asymmetry | Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA CSM_K8AB-PA_DS_E_3_1 Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. • Monitor voltage asymmetry, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with just one |
Original | ||||
| Three-phase Voltage and Phase-sequence Phase-loss | Three-phase Voltage and Phase-sequence Phase-loss Relay K8AK-PM Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. • Greater resistance to inverter noise. • Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power |
Original | ||||
| x10642 | BURST FIRING TRIGGER MODULES BFTM-1 BFTM-3 X10642 1 & 3 PHASE INTRODUCTION The BFTM-1 and BFTM-3 single and three phase burst firing trigger modules designed to drive our full range of thyristors and triacs. The BFTM-1 is a single phase or 2-wire format capability where as the BFTM-3 has a one-phase supply controlling |
Original | ||||
| SmartOnline 10kVA On-Line Double-Conversion UPS, | SmartOnline 10kVA On-Line Double-Conversion UPS, 3 Phase Input, Single Phase Output Highlights 10,000 VA (10kVA) extended run tower UPS MODEL NUMBER: SU10K3/1X 3-phase hardwire input (220/380, 230/400, 240/415 VAC) Single-phase hardwire output (user-selectable 220 or 230 or |
Original | ||||
| sl10 | 10 A 3-phase SL10.300 SL10.309 (Conformal Coated) CB scheme Data sheet IEC60950 • Input: 3 AC 400-500V (2-phase and 3-phase operation) • Output: 24-28V / 240W • Power Boost up to 288W • External primary fuse not necessary • Switchable operating mode |
Original | ||||
| 750w | 12 1-800-735-6200 Off-Line Front Ends Single or Three Phase Strappable Features ■ 250W, 500W, 750W, 115/230Vac Strappable Single-Phase ■ 1.5, 3, 5 kW, 208Vac Three-Phase ■ 20-50 mS Holdup ■ UL, CSA, TÜV, VDE, BABT ■ FCC/VDE Class B (single-phase) |
Original | ||||
| phase failure | G2PI1 400V Voltage measurement in 3-phase mains for 3- and 4-wire circuit Connection of neutral wire optional Monitoring of phase sequence and phase failure Monitoring of asymmetry Reinforced insulation of the measuring circuit Measured value transmitting via standard bus |
Original | ||||
| E1YF, E1YU Monitoring relays - ENYA series | E1YF, E1YU Monitoring relays - ENYA series Voltage monitoring in 3-phase mains Undervoltage monitoring Supply voltage = measured voltage 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions Switching frequency: Undervoltage monitoring in 3-phase mains (each phase against the |
Original | ||||
| E1YM Monitoring relays - ENYA series Voltage | E1YM Monitoring relays - ENYA series Voltage monitoring in 3-phase and 1-phase mains Multifunction Monitoring of phase failure Monitoring of phase sequence selectable Connection of neutral wire optional 1 change over contact Width 17.5 mm Installation design |
Original | ||||
|
|
||||||
| k3ym400vsy20 | K3YM400VSY20 Monitoring relays - KAPPA series Voltage monitoring in 3-phase- and 1-phase mains Multifunction Monitoring of phase failure and asymmetry Monitoring of phase sequence selectable Connection of neutral wire optional 2 change over contacts Plug-in housing |
Original | ||||
| sl10 | 10 A 3-phase CB scheme SL10.300 IEC60950 Data sheet UL508 LISTED IND. CONT. EQ. 18 WM, 60°C • Input: 3 AC 400-500V (2-phase and 3-phase operation) • Output: 24-28V / 240W • Power Boost up to 288W • External primary fuse not necessary • Switchable operating mode |
Original | ||||
| ARTESSrN ft E C H N O L Oi M I G g I M3000 and | ARTESSrN ft E C H N O L Oi M I G g I M3000 and M4000 SERIES E Single output S • Load currents up to 800A • 3 phase or single phase input • Shutdown on phase loss • 3 phase power factor correction • Single wire current share to 5% • Ideal for N+1 applications |
OCR Scan | ||||
| d65par | TAB49.BOO Page 84 Thursday, March 5, 2009 7:36 PM Control Relays & Timers Phase Monitoring Relays 3-84 April 2009 D65 Series — Phase Loss, Reversal and Undervoltage Phase Loss, Reversal and Undervoltage Product Selection Table 3-133. Product Selection — D65PAR Series |
Original | ||||
| step down transformer | Datasheet Compact Power Supply with 3 Phase Input This switchmode power supply eliminates the need for a step down transformer in 360 - 480V, 3 phase applications. It is powered by the three phase mains and produces 24Vdc @ 2.3A. • |
Original | ||||
| ARTESSrN ft E C H N O L O>V mG g iI L2000 SERIES | ARTESSrN ft E C H N O L O>V mG g iI L2000 SERIES E Single output S • Load currents up to 400A • 3 phase or single phase input • Shutdown on phase loss • 3 phase power factor correction • Single wire current share to 5% • Ideal for N+1 applications |
OCR Scan | ||||
| ir2137 | IRMDAC4 IR2137/IR2171 Reference Design Kit For 3-phase/230V 3HP AC Motor Drives IR2137/IR2171 Power Board • 230V AC input / 2.2kW output IR2137Q monolithic 3-phase HVIC driver. IR2171S monolithic linear current sensing IC |
Original | ||||