Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    3 POLE CONTACTOR LIGHTING Search Results

    3 POLE CONTACTOR LIGHTING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCWA1225G
    Toshiba Electronic Devices & Storage Corporation High Power Switch / SPDT / WCSP14 Datasheet
    TC7USB42MU
    Toshiba Electronic Devices & Storage Corporation Dual SPDT USB switch, SPDT, UQFN10B, -40 to 85 degC Datasheet
    TC7MBL3125CFT
    Toshiba Electronic Devices & Storage Corporation Quad Bus Switch, SPST, TSSOP14, -40 to 85 degC Datasheet
    TC7MBL3257CFT
    Toshiba Electronic Devices & Storage Corporation Quad 1-of-2 Multiplexer/Demultiplexer, SPDT, TSSOP16, -40 to 85 degC Datasheet
    TC7PCI3212MT
    Toshiba Electronic Devices & Storage Corporation 2 Differential Channel, 2:1 multiplexer/demultiplexer, SPDT, TQFN20, -40 to 85 degC Datasheet

    Documents mentioning 3 POLE CONTACTOR LIGHTING

    Document Partial File Text Tags Type PDF
    a9c20833
    Product data sheet Characteristics A9C20833 contactor iCT - 3 poles - 3 NO - 25 A - 220..240 V AC Contactor application Motor-heating-lighting Range of product ICT Device short name ICT Poles description 3P Pole contact composition 3 NO Network type AC Utilisation category
    Original PDF
    De finit e Purpose Cont a c t ors 3 -pole Type
    De finit e Purpose Cont a c t ors 3 -pole Type CGDP • Definite Purpose Contactor Switching up to 40A inductive, 50A resistive Coils up to 575VAC, 50/60 Hz cRUus, CSA, CE, and RoHS Faston (standard) or box lug terminals Available configured as reversing definite
    Original PDF
    ct2000
    CT2000 Contactors CT Contactor For remote switching of power, heating, lighting and small utility motors. See page 172 for applications. Technical data ■ Installation in enclosures 15959 A1 1 3 A2 2 4 When installing several CT contactors side by side,
    Original PDF
    Control & Indication catalogue 15 Control &
    Control & Indication catalogue 15 Control & indication Switches, contactors, relays, push buttons & emergency lighting This section provides a selection of Isolating, changeover and selector switches, push buttons, indicator lights, delay timers, emergency lighting test packages, DIN socket outlets and contactors that
    Original PDF
    Lighting Contactors 37-1 Lighting Contactors June
    Lighting Contactors 37-1 Lighting Contactors June 2008 CA08102001E Contents Description Page Open Control CN35 Electrically Held… C30CN Mechanically Held…
    Original PDF
    Issued July 1993 B15333 Controlgear components
    Issued July 1993 B15333 Controlgear components ÔDIL M range The RS ÔDIL MÕ range of control gear components has been designed to meet modern requirements for heating, lighting and motor control. The components are manufactured to exceed the highest standards required in Europe and North America. They are suitable
    Original PDF
    XMC0 Series DEFINITE PURPOSE CONTACTORS
    XMC0 Series DEFINITE PURPOSE CONTACTORS DESCRIPTION American Zettlers XMC0 series of Definite Purpose Contactors are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air
    Original PDF
    Issued November 1991 012-384 Data Pack B Heating
    Issued November 1991 012-384 Data Pack B Heating and lighting contactors Data Sheet Figure 1 Circuit diagram 240V 50/60Hz 415V supply coil supply L1 L2 L3 N A1 1 3 5 13 * A2 2 4 6 14 Neutral bar E General A range of contactors in ratings up to 100A for switching three phase heating and lighting loads. All contactors have a 240Vac coil and are fitted into an IP55
    Original PDF
    b1238
    Issued November 1991 B12384 Heating and lighting contactors Features l Four ratings available, 25A, 45A, 80A and 100A (AC1), all with 240V, 50Hz coils l Suitable for switching heating and lighting loads l 25A and 45A contactors have 4 main poles, 80A and 100A contactors have 3 main poles
    Original PDF
    eh145
    Across the line contactors Type A, B & EH 1 B9 – B75, A95 – A110 • AC 1000 – 2/97 • CONTACTORS: Selection: 1.4 - 1.7 EH145 – EH800 Maximum UL/CSA horsepower ratings • Maximum UL/CSA horsepower ratings
    Original PDF
    vacuum circuit breaker
    Vacuum Circuit Breaker 1- ZW8-12, ZW8-12G series high voltage vacuum circuit breaker Summarize ZW8-12 senies vacuum circuit breaker is high voltage outdoor switch equipment of rated voltage 12KV, triphase AC50Hz, which is mainly applicable network, urban network and mini power system, The product’s
    Original PDF
    contactor
    iJ W M / Ç P O t The Durakool 60 Amp high performance contactor (norm ally open) is designed for resistive loads typical in industrial ovens, food processing and laboratory equipm ent, lighting and com puter power supplies, plus medical and com m unications
    OCR Scan PDF
    Accessories – Field Installable CA7 Contactors
    Accessories – Field Installable CA7 Contactors Contact Block Description NO NC Contact Arrangement Standard Contacts Catalog For use with… Number Bifurcated Contacts Catalog Price Number ➋ Price 51 61 2 CA7 all CS7-PV-02 27 CS7-PVB-02 42 CA7-30…97-✱-00
    Original PDF
    Contactors - AC Coil Four Pole - Series CA7 A
    Contactors - AC Coil Four Pole - Series CA7 A Non-Reversing, Four Pole Contactors With AC Coil, Series CA7 (Open type only) Contactors Ratings for Switching AC Motors (AC2 / AC3 / AC4) Open Type Contact Configuration, Ie [A] kW (50 Hz) UL/CSA HP (60 Hz) Main Pole Catalog
    Original PDF
    XMC0 Series Definite Purpose Contactors
    XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1-Pole, 1-Pole+1Shunt, 1-Pole+1NC, 1-Pole+1NO, 2-Pole, 3-Pole,3-Pole+1NC and 3-Pole+1NO ,from 12A to 90A ) are ideal for(HVAC)air conditioning, refrigeration, heating, data
    Original PDF
    60947
    22100_Ver2.00-EN.backup.fm Page 2 Thursday, October 25, 2001 4:40 PM Characteristics Contactors Mini-contactors types LC1-SK and LP1-SK Environment Rated insulation voltage (Ui) 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508
    Original PDF
    Control Overview 4 Contents Direct on Line Starters…4/2 - 4/3 Direct on Line Starters + Isolator…4/4
    Original PDF
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar
    CONTENT KIN AUTOMATI ON SDN. BHD. ANDELI Bus bar Support Power Supply MCB Bar Contactor / Thermal Overload Relay / Auxiliary Contact Terminal Block Din Rail Terminal Block C/W Cover Terminal Block Float Switch Foot Switch Warning Light / Tower Light Hour Run Meter / Time Switch / Weather Proof Isolating Switch
    Original PDF
    PROTECTIVE DEVICES & ACCESSORIES MEMERA A
    PROTECTIVE DEVICES & ACCESSORIES MEMERA A comprehensive range of protective devices and accessories to complement both the Memera 2000 and Memera 2000 AD consumer unit range. 250 Ancillary devices Contactors and impulse relays 253-254 253 Enclosures 255 HRC fuse modules
    Original PDF
    Accessories & Modification Codes 16-1 Accessories
    Accessories & Modification Codes 16-1 Accessories & Modification Codes April 2008 Contents 16 Description Page Accessories IT. NEMA… Freedom NEMA…
    Original PDF
    Definite Purpose Control Product Family Overview
    Definite Purpose Control Product Family Overview 1 May 2007 Application Description These Cutler-Hammer® ampere and horsepower rated devices from Eaton’s electrical business are designed for service in applications such as Refrigeration, Air Conditioning
    Original PDF
    b11404
    Issued March 1991 B11404 The Siemens range of motor control gear The RS Ô3TF3Õ is a versatile range of control gear covering contactor ratings from 4kW to 15kW in three frame sizes. Sizes 0 and 1 are 45mm wide (up to 11kW) and size 2 is 55mm wide. The range is designed for users of
    Original PDF
    a9c20132
    Product data sheet Characteristics A9C20132 iCT 25A 2NO 24V 50Hz contactor Contactor application Motor-heating-lighting Range of product ICT Device short name ICT Poles description 2P Pole contact composition 2 NO Network type AC Utilisation category AC-1 conforming to EN 60947-4-1
    Original PDF