2-DIGIT DOOR Search Results
2-DIGIT DOOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| AV-THLIN2RCAM-005 | Amphenol Cables on Demand | Amphenol AV-THLIN2RCAM-005 Thin-line Single RCA Coaxial Cable - RCA Male / RCA Male (Coaxial Digital Audio Compatible) 5ft | |||
| AD-CSMAJMMCXP-000 | Amphenol Cables on Demand | Amphenol AD-CSMAJMMCXP-000 SMA Jack to MMCX Plug Adapter - Amphenol Connex RF Adapter (SMA Female / MMCX Male) 2 | |||
| AD-CONNPBNCJK-000 | Amphenol Cables on Demand | Amphenol AD-CONNPBNCJK-000 N Plug to BNC Jack Adapter - Amphenol Connex RF Adapter (N Male / BNC Female) 2 | |||
| AD-COSMAJSMBP-000 | Amphenol Cables on Demand | Amphenol AD-COSMAJSMBP-000 SMA Jack to SMB Plug Adapter - Amphenol Connex RF Adapter (SMA Female / SMB Male) 2 | |||
| DCL540C01 | Toshiba Electronic Devices & Storage Corporation | Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: Low | Datasheet |
Documents mentioning 2-DIGIT DOOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 1- or 2-Channel Circular Recorders MADE IN | 1- or 2-Channel Circular Recorders MADE IN Optional USA Model CT5100 $ 655 Basic Unit ߜ 254 mm (10") Chart ߜ 1- or 2-Pen Versions, ߜ Thermocouple, RTD, dc Current, or Voltage Input ߜ Programmable Inputs ߜ 4-Digit 14 mm (0.56") Display CT5100 Series Circular Chart |
Original | ||||
| Dupline® Field- and Installationbus Display | Dupline® Field- and Installationbus Display Receiver with Limit Outputs Type D 6369 6475 • 4-digit 7-segment LED-display with sign Freely scaleable 2 relay limit outputs (HI, LO) 2 NPN transistor limit outputs (HIHI, LOLO) LED-indication for all limit outputs |
Original | ||||
| 4-digit 7-segment | Display Receiver with Limit Outputs Type D 6369 6475 Du line ® Fieldbus Installationbus • 4-digit 7-segment LED-display with sign Freely scaleable 2 relay limit outputs (HI, LO) 2 NPN transistor limit outputs (HIHI, LOLO) LED-indication for all limit outputs |
Original | ||||
| visipak | VISIPAKTM V560 Loop Powered LCD Indicator Provides a 3-1/2 Digit Liquid Crystal Display (LCD) in Proportion to a 4-20mA Current Input Description Benefits Eliminates Extra Power Supply LCD Readable from 30ft. Switch Selectable mA Inputs and Decimal Points |
Original | ||||
| IF TELEPHONE TWISTED PAIR TYPE CABLE IS USED, | IF TELEPHONE TWISTED PAIR TYPE CABLE IS USED, LINES 1 & 2 TO THE KEYPAD SHOULD CONSIST OF A PAIR FOR BOTH 1 & 2. RTE. DOOR 1 ONLY N/O. PUSH SWT (COMMON TO 1) 10 9 8 7 6 5 4 3 2 1 NOT USED NOT USED NORMALLY OPEN PAIR DOOR 2 NORMALLY CLOSED DOOR 1 COMMON NORMALLY OPEN |
Original | ||||
| v10013 | V10013 Issued 02/2002 Programmable Access Keypad Instruction Leaflet Figures 1 3 Connecting a d.c. electric door lock to the keypad supply Connection terminals and allowed jumper positions This DIODE must be added Keypad Electric door lock 1 Power (+) Red LED control |
Original | ||||
| APPLICATION NOTE CODED LOCK USING THE | APPLICATION NOTE CODED LOCK USING THE ST6-REALIZER by Olivier Rouy INTRODUCTION The trend is to provide more and more applications with security features. This is requested to insure data confidentiality, access control, or simply user identification. Non Volatile Memory is usually required to |
Original | ||||
| APPLICATION NOTE CODED LOCK USING THE | APPLICATION NOTE CODED LOCK USING THE ST6-REALIZER by Olivier Rouy INTRODUCTION The trend is to provide more and more applications with security features. This is requested to insure data confidentiality, access control, or simply user identification. Non Volatile Memory is usually required to |
Original | ||||
| Motor Control Centers–Low Voltage Section 12: | Motor Control Centers–Low Voltage Section 12: Motor Control Centers—Low Voltage E9000 Evolution/8000/Spectra Low Voltage Motor Control Centers Product References: Engineered Products Catalog Application and Selection Guide Application and Selection Guide |
Original | ||||
| an840 | AN840 APPLICATION NOTE Coded lock using the ST6-REALIZER INTRODUCTION The trend is to provide more and more applications with security features. This is requested to insure data confidentiality, access control, or simply user identification. Non Volatile Memory is usually required to |
Original | ||||
| Application Note AN2264/D Rev. 0, 3/2002 LIN Node | Application Note AN2264/D Rev. 0, 3/2002 LIN Node Temperature Display by Peter Topping 8/16 Bit Applications Engineering Motorola, East Kilbride Introduction Many of the problems of excessive wiring within a car can be resolved by using a serial multiplex bus like CAN or LIN. The LIN (Local Interconnect Network, |
Original | ||||
| &/&/$ Microprocessor Controlled Digital | &/&/$ Microprocessor Controlled Digital Keypads Installation Instructions '(6&5,37,21 6\VWHPDQG$SSOLFDWLRQ The CL-8 is a self-contained, versatile microprocessor-controlled digital keypad for indoor access control and remote control applications in security systems. Its main purpose is to limit |
Original | ||||
| Freescale Semiconductor, Inc… Freescale | Freescale Semiconductor, Inc… Freescale Semiconductor, Inc. Application Note AN2264/D Rev. 0, 3/2002 LIN Node Temperature Display by Peter Topping 8/16 Bit Applications Engineering Motorola, East Kilbride Introduction Many of the problems of excessive wiring within a car can be resolved by using |
Original | ||||
| an2264 | Freescale Semiconductor Application Note Document Number: AN2264 Rev. 1, 01/2007 LIN Node Temperature Display by: Peter Topping East Kilbride 1 Introduction Many of the problems of excessive wiring within a car can be resolved by using a serial multiplex bus like CAN |
Original | ||||
|
|
||||||
| ground tester | Fluke 1623 and 1625 GEO Earth Ground Testers Technical Data The new Fluke 1623 and 1625 GEO Earth Ground Testers offer an innovative solution, called Stakeless testing, to make your earth ground loop resistance testing quicker and easier. No need for a separate earth |
Original | ||||
| Fluke 1625/1623 GEO Earth Ground Testers Advanced | Fluke 1625/1623 GEO Earth Ground Testers Advanced technology for all your earth ground testing applications 1623 • One-button measurement concept 3- and 4-pole earth ground measurement 4-Pole soil resistivity testing 2-pole resistance measurement AC |
Original | ||||
| pro3000 | PRO3000 2-Door Intelligent Controller The PRO3000 IP-enabled controller is an advanced access control panel capable of providing solutions for medium to large applications. The PRO3000 provides power and flexibility with its 32-bit CPU architecture, TCP/IP protocol support, flash memory for firmware and |
Original | ||||
| rfid reader | 599 Menlo Drive, Suite 100 Rocklin, California 95765, USA Office: (916) 624-8333 Fax: (916) 624-8003 General: info@parallax.com Technical: support@parallax.com Web Site: www.parallax.com Educational: www.stampsinclass.com RFID Reader Module (#28140) RFID 54 mm x 85 mm Rectangle Tag (#28141) |
Original | ||||
| rfid reader | 599 Menlo Drive, Suite 100 Rocklin, California 95765, USA Office: (916) 624-8333 Fax: (916) 624-8003 General: info@parallax.com Technical: support@parallax.com Web Site: www.parallax.com Educational: www.stampsinclass.com RFID Reader Module (#28140) RFID 54 mm x 85 mm Rectangle Tag (#28141) |
Original | ||||
| an1552 | MOTOROLA Order this document by AN1552/D SEMICONDUCTOR APPLICATION NOTE MPX7100AP: The Sensor at the Heart of Solid-State Altimeter Applications AN1552 By Chris Winkler and Jeff Baum Sensor Systems Engineering Group Motorola Semiconductor Products Sector Phoenix, Arizona |
Original | ||||