The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
PIC24HJ128GP506A-E/PT Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Temperature Range: 150C / 1hr w/l 24 hours
PIC24HJ128GP206A-E/PT Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Package: 64L TQFP 10x10x1mm; Temperature Range: 150C / 1hr w/l 24 hours
PIC24HJ128GP306AT-E/PT Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Package: 64L TQFP 10x10x1mm; Temperature Range: 150C / 1hr w/l 24 hours
PIC24HJ64GP210AT-E/PT Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Package: 100L TQFP 12x12x1mm; Temperature Range: 150C / 1hr w/l 24 hours
PIC24HJ128GP510A-E/PF Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Package: 100L TQFP 14x14x1mm; Temperature Range: 150C / 1hr w/l 24 hours
PIC24HJ128GP310AT-E/PT Microchip Technology Inc 16-bit PIC® MCUs & dsPIC® DSC; Package: 100L TQFP 12x12x1mm; Temperature Range: 150C / 1hr w/l 24 hours

12-hour Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
an618

Abstract: MAX6900 MAX6901 MAX6902
Text: Register: 12-hour format and 24- hour format. The interpretation of D5 depends on the hour format selected , , configures the hours counter for 12-hour format. D5 is used as the AM/PM indicator with 1 = PM and 0 = AM. Hours data in the 12-hour AM format or in the 12-hour PM format is contained in D4 through D0, and BCD , = 0). Table 6. Timekeeping Hours Register: 12-Hour AM Format Hours Register D7 D6 D5 D4 D3 D2 , 0 0 1 0 0 1 0 D1 D0 Note: Valid hour data ( 12-hour format) =01 to 12


Original
PDF com/an618 MAX6900: MAX6901: MAX6902: MAX6909: MAX6910: AN618, APP618, Appnote618, an618 MAX6900 MAX6901 MAX6902
12 Hour Digital Clock Circuit

Abstract: 24 hour Digital clock circuit 12 hour digital clock 500 hours timer circuit 24 hour timer application ECG1414 digital countdown timer block diagram of digital countdown timer ic timer 12v relay Fluorescent Indicator Tube
Text: ) (Second) indication. Minute indicates one digit, 12-Hour Mode AM/PM ( Hour ) (Second). Second colon , On-Off Timer, Sleep Timer—Reset. 12-Hour Mode: AM 12:00 Flash Indication, 2. On-Off Preset Timer 1 , Mode: Indication of ( Hour ) (Minute). 12-Hour Mode: Indication of AM or PM ( Hour ) (Minute). 3. Sleep , , Timer (CMOS) Features • 12 or 24 hour display operation • Input 50 or 60 Hz • Sleep timer to 1 hour and 59 minutes • Stopwatch to 1 hour and 59 minutes • Direct fluorescent drive • 24 hour


OCR Scan
PDF ECG1414 ECG1414 30l-dU-MAX. 10HRS-b G0GSM33 111111ii 12 Hour Digital Clock Circuit 24 hour Digital clock circuit 12 hour digital clock 500 hours timer circuit 24 hour timer application digital countdown timer block diagram of digital countdown timer ic timer 12v relay Fluorescent Indicator Tube
2005 - alarm Clock lm8560

Abstract: lm8560 lm8560 datasheet 12 Hour Digital Clock Circuit alarm Clock lm8560 FUNCTION pin configuration LM8560 7 segment 24 hr clock circuit duplex clock led display 7 segment led 12 Hour Digital Clock Circuit led display alarm clock
Text: voltage range *Built-in alarm function with 24- hour control *Supports changeover between 12-hour AM/PM and 24- hour displays *Built-in battery backup CR oscillator *Users 50Hz or 60Hz as standard frequency *Built-in automatic fast forward function for hour and minute settings *Built-in sleep timer , hour and minute digits as [0:00] when operating in 24- hour mode or [12:00] when operating in 12-hour , : When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables


Original
PDF LM8560 LM8560 24-hour 12-hour 24-hour QW-R502-005 alarm Clock lm8560 lm8560 datasheet 12 Hour Digital Clock Circuit alarm Clock lm8560 FUNCTION pin configuration LM8560 7 segment 24 hr clock circuit duplex clock led display 7 segment led 12 Hour Digital Clock Circuit led display alarm clock
12 Hour Digital Clock Circuit

Abstract: 24 hour Digital clock circuit 10HRS-b ECG1414
Text: . Minute indicates one digit, 12-Hour Mode AM /PM ( Hour ) (Second). Second colon flashing and (Minute , - Reset. 12-Hour Mode: A M 12:00 Flash In dication. 2. On-Off Preset Timer 1. On-Off time can be preset at , ) (Minute). 12-Hour Mode: Indication of A M or PM ( Hour ) (Minute). 3. Sleep Timer 1. 1 hour 59 minutes (max , hour display operation Input 60 or 60 Hz Sleep timer to 1 hour and 59 minutes Stopwatch to 1 hour and 59 minutes Direct fluorescent drive · 24 hour on/off timer Forward/reverse time set capability Power


OCR Scan
PDF ECG1414 ECG1414 12 Hour Digital Clock Circuit 24 hour Digital clock circuit 10HRS-b
SC8560

Abstract: 50 hz Oscillator Digital Alarm Clock sc8560 Digital Alarm Clock 12 Hour Digital Clock Circuit SC8560 DIGITAL ALARM CLOCK digital clock with alarm SC8560S led display alarm clock SC8560 circuit diagram
Text: ) * Wide operating power supply voltage range * Built-in alarm function with 24- hour control SDIP-28 * Supports changeover between 12-hour AM/PM and 24- hour displays * Built-in battery backup CR oscillator * Built-in automatic fast forward function for hour and minute ORDERING INFORMATION settings , unconnected (VDD) causes the 12-hour basis to be selected, 12/24H Select Input connecting this pin to , operating in 24- hour mode or [12:00] when operating in, 12-hour mode. Sets sleep counter to [0:59


Original
PDF SC8560 SC8560 OP-28 24-hour SDIP-28 12-hour 24-hour intervals10k 900Hz 50 hz Oscillator Digital Alarm Clock sc8560 Digital Alarm Clock 12 Hour Digital Clock Circuit SC8560 DIGITAL ALARM CLOCK digital clock with alarm SC8560S led display alarm clock SC8560 circuit diagram
SC8560

Abstract: Digital Alarm Clock sc8560 SC8560 circuit diagram SC8560 DIGITAL ALARM CLOCK digital clock ic SC8560S 12 Hour Digital Clock Circuit SDIP-28 Digital Alarm Clock 16 PIN duplex led display
Text: ) * Wide operating power supply voltage range * Built-in alarm function with 24- hour control SDIP-28 * Supports changeover between 12-hour AM/PM and 24- hour displays * Built-in battery backup CR oscillator * Built-in automatic fast forward function for hour and minute settings ORDERING INFORMATION Part No , unconnected (VDD) causes the 12-hour basis to be selected, 12/24H Select Input connecting this pin to , operating in 24- hour mode or [12:00] when operating in, 12-hour mode. Sets sleep counter to [0:59


Original
PDF SC8560 SC8560 OP-28 24-hour SDIP-28 12-hour 24-hour 900Hz Digital Alarm Clock sc8560 SC8560 circuit diagram SC8560 DIGITAL ALARM CLOCK digital clock ic SC8560S 12 Hour Digital Clock Circuit SDIP-28 Digital Alarm Clock 16 PIN duplex led display
alarm Clock lm8560

Abstract: sanyo lm8560 LM8560 alarm Clock lm8560 FUNCTION LM8560 USED 7 segment display with alarm 7 segment 24 hr clock circuit alarm Clock lm8560 count down circuits IL8560 50hz into 60hz circuit diagram
Text: operating voltage range · Alarm on a 24- hour basis · Time format: 12-hour AM/PM and 24hour · On-chip , second later. BOTH HOUR "Hours" and "Minutes" are reset to [0:00] (24- hour basis) or [12:00] ( 12-hour , : Leaiving this pin unconnected (VDD) causes the 12-hour basis to be selected; connecting this pin to VSS , automatically advance "hours", "minutes" · Sleep timer (max. 59 minutes or 1 hour 59 minutes) · Repeatedly , snooze · Sleep timer (max. 59 minutes or 1 hour 59 minutes) PIN CONNECTION 900Hz output for alarm


Original
PDF IL8560 24-hour 12-hour 24hour 900Hz OP-28 LM8560 50Hz/60Hz 50/601-tz alarm Clock lm8560 sanyo lm8560 LM8560 alarm Clock lm8560 FUNCTION LM8560 USED 7 segment display with alarm 7 segment 24 hr clock circuit alarm Clock lm8560 count down circuits IL8560 50hz into 60hz circuit diagram
2002 - P21096

Abstract: 208-MIL P2075
Text: 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 0 0 0 0 0 0 0 0 DEVICE HRS: 3.08E+07 300 1000 274 959 96 CYCL CYCL HOUR HOUR HOUR P20963 TEMP CYCLE -55 TO 125°C TOTAL: P20964 BIASED , VOLTS TOTALS: QUANTITY READPOINT UNITS 234 77 77 FAIL RATE (Fits): 30 40 40 77 77 40 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 0 0 0 0 0 0 0 0 DEVICE HRS: 3.08E+07 300 1000 274 959 96 CYCL CYCL HOUR HOUR HOUR P21489 TEMP CYCLE -55 TO 125°C TOTAL: P21490 BIASED MOISTURE 85/85


Original
PDF DS1000M-25 DS1000 DD711504ABA P20931 P20962 P21300 P21353 P21354 P21355 P21356 P21096 208-MIL P2075
2004 - lm8560

Abstract: alarm Clock lm8560 alarm Clock lm8560 FUNCTION pin configuration LM8560 7 segment 24 hr clock circuit 7 segment 24 hr clock circuit ic lm8560 DIGITAL CLOCK IC 60Hz to 50Hz circuit diagram "Digital Alarm Clock" lm8560 datasheet
Text: voltage range *Built-in alarm function with 24- hour control *Supports changeover between 12-hour AM/PM and 24- hour displays *Built-in battery backup CR oscillator *Users 50Hz or 60Hz as standard frequency *Built-in automatic fast forward function for hour and minute settings *Built-in sleep timer , hour and minute digits as [0:00] when operating in 24- hour mode or [12:00] when operating in 12-hour , : When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables


Original
PDF LM8560 LM8560 24-hour 12-hour 24-hour QW-R502-005 alarm Clock lm8560 alarm Clock lm8560 FUNCTION pin configuration LM8560 7 segment 24 hr clock circuit 7 segment 24 hr clock circuit ic lm8560 DIGITAL CLOCK IC 60Hz to 50Hz circuit diagram "Digital Alarm Clock" lm8560 datasheet
2009 - lm8560l

Abstract: LM8560 7 segment 24 hr clock circuit ic lm8560 alarm Clock lm8560 pin configuration LM8560 duplex led display alarm clock 12 hour digital clock with 7 segment displays and LM8560G digital clock ic alarm Clock lm8560 FUNCTION
Text: ) *Wide operating power supply voltage range *Built-in alarm function with 24- hour control *Supports changeover between 12-hour AM/PM and 24- hour displays *Built-in battery backup CR oscillator *Users 50Hz or 60Hz as standard frequency *Built-in automatic fast forward function for hour and minute , mode or [12:00] when operating in 12-hour mode. Sleep Sets sleep counter to [0:59] instantly when , ), a 12-hour display is enabled whereas connecting this pin to VSS enables the 24- hour display. A


Original
PDF LM8560 LM8560 24-hour 12-hour 24-hour QW-R502-005 lm8560l 7 segment 24 hr clock circuit ic lm8560 alarm Clock lm8560 pin configuration LM8560 duplex led display alarm clock 12 hour digital clock with 7 segment displays and LM8560G digital clock ic alarm Clock lm8560 FUNCTION
2005 - Not Available

Abstract: No abstract text available
Text: ) (IN) (IN) (IN) (IN) (IN) (IN) (IN) FUNCTION_ AM & 10’S HOUR AG & DE PM & 10’S HOUR B 10’S HOUR C & HOUR E HOUR B & G HOUR C & D HOUR A & F 10’S MINUTES A & F , RANGE SELECT RELAY DRIVE OUTPUT OFF INPUT AUTO TIME SET VDD(-) MINUTE SET HOUR SET MANUAL ON INPUT AUTO ON INPUT 50/60 HERTZ INPUT 50/60 HERTZ SELECT 2/4 OR 1/8 HOUR SELECT 12/24 HOUR DISPLAY , 010583 for 60Hz, 12 Hour Operation. POWER FAILURE INDICATION If the voltage drops below the Power Fail


Original
PDF RE221I WT2232 RE221 RE221r050928
2003 - 7 segment 24 hr clock circuit ic lm8560

Abstract: alarm Clock lm8560 FUNCTION 12 Hour Digital Clock Circuit alarm Clock lm8560 Digital alarm clock ic with 28 pin pin configuration LM8560 lm8560 7 segment 24 hr clock circuit 7 segment led 12 Hour Digital Clock Circuit Digital Alarm Clock
Text: voltage range *Built-in alarm function with 24- hour control *Supports changeover between 12-hour AM/PM and 24- hour displays *Built-in battery backup CR oscillator *Users 50Hz or 60Hz as standard frequency *Built-in automatic fast forward function for hour and minute settings *Built-in sleep timer , hour and minute digits as [0:00] when operating in 24- hour mode or [12:00] when operating in 12-hour , : When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables


Original
PDF LM8560 LM8560 24-hour 12-hour 24-hour 900Hz QW-R502-005 7 segment 24 hr clock circuit ic lm8560 alarm Clock lm8560 FUNCTION 12 Hour Digital Clock Circuit alarm Clock lm8560 Digital alarm clock ic with 28 pin pin configuration LM8560 7 segment 24 hr clock circuit 7 segment led 12 Hour Digital Clock Circuit Digital Alarm Clock
2003 - Not Available

Abstract: No abstract text available
Text: voltage range *Built-in alarm function with 24- hour control *Supports changeover between 12-hour AM/PM and 24- hour displays *Built-in battery backup CR oscillator *Users 50Hz or 60Hz as standard frequency *Built-in automatic fast forward function for hour and minute settings *Built-in sleep timer , digits as [0:00] when operating in 24- hour mode or [12:00] when operating in 12-hour mode. Sleep Sets , : When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables


Original
PDF LM8560 LM8560 24-hour 12-hour 24-hour 900Hz QW-R502-005
SC8560

Abstract: design 12 Hour Digital Clock Circuit Digital Alarm Clock sc8560 SC8560 circuit diagram 12 Hour Digital Clock Circuit SC8560 DIGITAL ALARM CLOCK 7 segment led 12 Hour Digital Clock Circuit digital clock ic 24 hour Digital clock circuit Digital alarm clock ic with 28 pin
Text: operating power supply voltage range SDIP-28 * Built-in alarm function with 24- hour control * Supports changeover between 12-hour AM/PM and 24- hour displays * Built-in battery backup CR oscillator * Built-in automatic fast forward function for hour and minute settings ORDERING INFORMATION Part No , pins. A pulldown resister is built-in. Leaving this pin unconnected (VDD) causes the 12-hour basis to , operating in, 12-hour mode. Sleep Sets sleep counter to [0:59] instantly when VDD is activated to


Original
PDF SC8560 SC8560 OP-28 SDIP-28 24-hour 12-hour 24-hour SDIP-28-400-1 design 12 Hour Digital Clock Circuit Digital Alarm Clock sc8560 SC8560 circuit diagram 12 Hour Digital Clock Circuit SC8560 DIGITAL ALARM CLOCK 7 segment led 12 Hour Digital Clock Circuit digital clock ic 24 hour Digital clock circuit Digital alarm clock ic with 28 pin
2009 - FF34H

Abstract: FF460 FF60MH FF60M FF312HH FF60MHC FF32H
Text: hour SPST Simulated brushed metal no FF12HHC 12 hour SPST Simulated brushed metal , Simulated brushed metal yes FF2H 2 hour SPST Simulated brushed metal no FF30MC 30 , yes FF312H 12 hour SPDT Simulated brushed metal no FF312HH 12 hour SPDT Simulated brushed metal yes FF32H 2 hour SPDT Simulated brushed metal no FF32HH 2 hour SPDT Simulated brushed metal yes FF34H 4 hour SPDT Simulated brushed metal


Original
PDF FF415M FF430M FF460M FF46H FF60MC FF60MHC FF34H FF460 FF60MH FF60M FF312HH FF60MHC FF32H
1997 - ic 4790 A

Abstract: chime circuit c 5929 7 segment display with alarm 4 digit lcd display for watch 32768-Hz 4790 alarm sound LCD 4digit piezo bz1
Text: battery operation An internal voltage doubler 32768Hz crystal oscillator 12-hour or 24- hour format. General Description seconds, month, date, use 12-hour /24- hour format, and generate chime sounds every , Description Operational flow chart 5 2nd Apr '97 HT1340 · Initial states · 12-hour /24- hour , : Selection of 12-hour or 24- hour format is available for display. When the IC enters the hour (Real-time , -year calendar Alarm/Chime enable/disable operation Chimes output on every hour 30-second alarm sound


Original
PDF HT1340 30-second 32768Hz 12-hour 24-hour 12-hour/24-hour HT1340 HT134 ic 4790 A chime circuit c 5929 7 segment display with alarm 4 digit lcd display for watch 32768-Hz 4790 alarm sound LCD 4digit piezo bz1
2002 - DS87520

Abstract: dm8304 P2271 DS2165Q
Text: 238 40 40 77 37 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 3 3 DEVICE HRS: 3.08E+07 1 24 168 3 300 1000 100 96 WEEK HOUR HOUR PASS CYCL CYCL HOUR HOUR P22673 P22674 ULTRASOUND HIGH TEMP , READPOINT UNITS 234 77 77 30 4 238 238 238 40 40 77 40 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 0 0 DEVICE HRS: 3.08E+07 1 24 168 3 300 1000 100 96 WEEK HOUR HOUR PASS CYCL CYCL HOUR HOUR P23062 P23063 , QUANTITY READPOINT UNITS 229 77 77 30 4 233 233 233 40 40 72 40 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0


Original
PDF DS1232L DL817678ABB P22755 P22778 J-STD-020 DS87520 DN825394AAB DS87C520 P23306 dm8304 P2271 DS2165Q
2010 - Not Available

Abstract: No abstract text available
Text: GENERAL DESCRIPTION The ML9098B is a 24- hour / 12-hour car clock IC that drives 1/2-duty dynamic or static , adjustment functions in hour , minute, and 30-minute units. FEATURES • 24- hour or 12-hour system â , the logic section. Power supply pin for the driver section. Ground pin. Pin for selecting the 12-hour or 24- hour system. “H” level: 24- hour system, “L” level: 12-hour system with AM/PM display , 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 0:00 12-hour display AM 1:00 AM 2:00 AM


Original
PDF FEDL9098B-01 ML9098B ML9098B 24-hour/ 12-hour 30-minute 24-hour 194304MHz
LM8569

Abstract: laf 0001 Supply Control LAF 0001 900Hz PIE20 LM85 sanyo Digital Alarm Clock 12 Hour Digital Clock Circuit pa 3029a duplex led display alarm clock
Text: * and 'Minutes' are reset to [0:001 (24- hour basis) or [12:00] ( 12-hour basis). Alarm HOUR MIN BOTH , to [0:00] (24- hour basis) or [12:00] ( 12-hour basis). Sleep HOUR MIN BOTH The moment Voo is applied , the 12-hour basis to be selected; connecting this pin to Vgs causes the 24- hour basis to be selected , /7 LM8569 Sample Application Circuit for Clock Radio Use( + power supply) 12-hour basis» 60Hiuse , hour 59 minutes) Features ® Single-chip P-channel ED MOS LSI (2) LED direct drive by time-sharing


OCR Scan
PDF LM8569 24-hour 900Hz 900Hz, 50/60Hz LM8569 laf 0001 Supply Control LAF 0001 PIE20 LM85 sanyo Digital Alarm Clock 12 Hour Digital Clock Circuit pa 3029a duplex led display alarm clock
lmb560

Abstract: 6560B Digital Alarm Clock 7 segment 24 hr clock circuit duplex led display alarm clock sanyo Digital Alarm Clock lmb560n LM8560B lm8560 d2095
Text: changeover between 12-hour AM/PM and 24- hour displays • Built-in battery backup CR oscillator • Uses , :00] when operating in 12-hour mode. Sleep HOUR MIN BOTH Sets sleep counter to [0:59] instantly when , (VDD), a 12-hour display is enabled whereas connecting this pin to Vss enables the 24- hour display. A , supply) 12-hour display and 60 Hz Circuit Diagram 0.001A« X- 100k JT 12HR Al NC 60Hz NC »I , Applied Circuit Diagram (- power supply) Unit (resistance: fì,capacitance:F) 12-hour display and Hz


OCR Scan
PDF EN3490B LM8560N, 8560B LM8560N LM8560B lmb560 6560B Digital Alarm Clock 7 segment 24 hr clock circuit duplex led display alarm clock sanyo Digital Alarm Clock lmb560n lm8560 d2095
2005 - Not Available

Abstract: No abstract text available
Text: ) (IN) (IN) (IN) (IN) (IN) (IN) FUNCTION_ AM & 10’S HOUR AG & DE PM & 10’S HOUR B 10’S HOUR C & HOUR E HOUR B & G HOUR C & D HOUR A & F 10’S MINUTES A & F 10’S , SELECT RELAY DRIVE OUTPUT NC AUTO TIME SET VDD(-) MINUTE SET HOUR SET MANUAL ON/OFF INPUT AUTO ON/OFF INPUT 50/60 HERTZ INPUT 50/60 HERTZ SELECT 2/4 OR 1/8 HOUR SELECT 12/24 HOUR DISPLAY SELECT , compatible with the circuit shown in Worldtronics Schematic 011366 for 60Hz, 12 Hour Operation. POWER


Original
PDF RE223I WT2233 RE223 RE223r050928
1997 - TMS3450NL

Abstract: "duplex led display" duplex clock led display sl-1042 SL-1042T 16 PIN duplex led display tms 3450nl 12 Hour Digital Clock Circuit 20 PIN duplex led display 30 PIN duplex led display
Text: of digital 1; otherwise, it is connected to dot3 when the system is in the 12-hour format. Refer , Pull-Low 12-hour or 24- hour format display selection input 12-hour format (MODE is open) is the normal , format display mode. Normally the display mode is the 12-hour format when the MODE is open. 50/60Hz AC , to dot3 for 12-hour format. Note: The display module is used such as SL-1042T (TOTTORI SANYO , Direct drive piezo 4 display modes 1 hour and 59 minutes alarm sound 9 minute snooze time Back up


Original
PDF HT1391 3450NL 300mil) 50/60Hz 12/24-hour HT1391 AM/24 24-hour TMS3450NL "duplex led display" duplex clock led display sl-1042 SL-1042T 16 PIN duplex led display tms 3450nl 12 Hour Digital Clock Circuit 20 PIN duplex led display 30 PIN duplex led display
2002 - P22243

Abstract: DS1267E DN7-36 P22154 P21256
Text: 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 0 0 0 0 0 0 0 0 DEVICE HRS: 3.08E+07 300 1000 274 959 96 CYCL CYCL HOUR HOUR HOUR P21489 TEMP CYCLE -55 TO 125°C TOTAL: P21490 BIASED , (Fits): 30 238 238 238 40 40 40 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 DEVICE HRS: 3.08E+07 24 168 3 300 1000 96 HOUR HOUR PASS CYCL CYCL HOUR P21287 HIGH TEMP STORAGE MOISTURE SOAK , 238 38 38 38 48 336 1000 HOUR HOUR HOUR NO OF FAILS 0 0 0 0 DEVICE HRS: 3.08E+07 24 168 3 400


Original
PDF DS1000M-25 DS1000 DD740614ABA P21467 P21488 P21893 P21964 P21965 P21966 P21967 P22243 DS1267E DN7-36 P22154 P21256
2008 - Digital Alarm Clock sc8560

Abstract: SC8560 circuit diagram 24 hour Digital clock circuit SC8560 duplex led display alarm clock
Text: operating power supply voltage range SDIP-28 * Built-in alarm function with 24- hour control * Supports changeover between 12-hour AM/PM and 24- hour displays * Built-in battery backup CR oscillator * Built-in automatic fast forward function for hour and minute settings ORDERING INFORMATION Part No , . Leaving this pin unconnected (VDD) causes the 12-hour basis to be selected, 12/24H Select Input , and minute digits to [0:00] when operating in 24- hour mode or [12:00] when operating in, 12-hour mode


Original
PDF SC8560 SC8560 OP-28 SDIP-28 24-hour 12-hour 24-hour SDIP-28-400-1 Digital Alarm Clock sc8560 SC8560 circuit diagram 24 hour Digital clock circuit duplex led display alarm clock
2010 - 7-segment-display pin configuration

Abstract: SEG22 SEG23
Text: GENERAL DESCRIPTION The ML9098B is a 24- hour / 12-hour car clock IC that drives 1/2-duty dynamic or static , adjustment functions in hour , minute, and 30-minute units. FEATURES · 24- hour or 12-hour system · Power , supply pin for the driver section. Ground pin. Pin for selecting the 12-hour or 24- hour system. "H" level: 24- hour system, "L" level: 12-hour system with AM/PM display. Adjustment enable pin. "L" level , 19:00 20:00 21:00 22:00 23:00 0:00 12-hour display AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5


Original
PDF FEDL9098B-01 ML9098B ML9098B 24-hour/ 12-hour 30-minute 24-hour 194304MHz 7-segment-display pin configuration SEG22 SEG23
Supplyframe Tracking Pixel