Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    0-10V SENSOR Search Results

    0-10V SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MRMS791B
    Murata Manufacturing Co Ltd Magnetic Sensor PDF
    MRUS74SD-001
    Murata Manufacturing Co Ltd Magnetic Sensor PDF
    MRUS74SK-001
    Murata Manufacturing Co Ltd Magnetic Sensor PDF
    MRMS591P
    Murata Manufacturing Co Ltd Magnetic Sensor PDF
    MRMS581P
    Murata Manufacturing Co Ltd Magnetic Sensor PDF

    0-10V SENSOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    0-5 v to 4-20 ma converter

    Abstract: LVDT Signal Conditioner 3B39 8504mA
    Contextual Info: Isolated Process Current Output 3B39 FEATURES Interfaces, isolates, & filters a 0 to +10V or -10V to +10V input signal and provides an isolated process current output across loads of 0 to 850Ω. Intended for high-accuracy process control and monitoring applications requiring total galvanic isolation.


    Original
    D05117-0-9/04 0-5 v to 4-20 ma converter LVDT Signal Conditioner 3B39 8504mA PDF

    gefran 230

    Abstract: din pn10 PVDF PT100 temperature sensor water "Humidity Sensor" DN15-1 pt100 ANSI pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet
    Contextual Info: TRANSMICOR T242 series high temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measuring range: 0 . 100 %rh, -30 . +140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V, 0 . 10V selectable with jumper ,


    Original
    Pt100 230VAC S6000 S6000, S6000: S6000 250mm 6A05511 500mm gefran 230 din pn10 PVDF PT100 temperature sensor water "Humidity Sensor" DN15-1 pt100 ANSI pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet PDF

    gefran 230

    Abstract: T241 gefran pt100 PT100 temperature PT100 temperature sensor gefran 250 "Humidity Sensor" Gefran 40 pt100 0-10V PT100 SENSOR
    Contextual Info: TRANSMICOR T241 series RELATIVE HUMIDITY TRANSMITTER FOR WALL MOUNTING Main characteristics • Measuring range: 0 . 100 %rh, -30 .+ 70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA, 0 . 20mA, 0 . 10V, 2 . 10V selectable with jumper ,


    Original
    Pt100 230VAC S6000 S6000, 1A04640, 31XXA 4/20mA, 0/20mA, 0/10V, 2/10V gefran 230 T241 gefran pt100 PT100 temperature PT100 temperature sensor gefran 250 "Humidity Sensor" Gefran 40 pt100 0-10V PT100 SENSOR PDF

    gefran 230

    Abstract: din pn10 gefran pt100 PT100 temperature "Humidity Sensor" pt100 datasheet PT100 SENSOR pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet
    Contextual Info: TRANSMICOR T242 series low temperature RELATIVE HUMIDITY TRANSMITTER DUCT VERSION Main characteristics • Measurement range: 0 . 100 %rh, -30.+85 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V, 0 . 10V selectable with jumper ,


    Original
    Pt100 230VAC S6000 S6000, 6A03130 S6000 6A08840 gefran 230 din pn10 gefran pt100 PT100 temperature "Humidity Sensor" pt100 datasheet PT100 SENSOR pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet PDF

    gefran 230

    Abstract: gefran pt100 PT100 temperature "Humidity Sensor" pt100 measurement pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet Pt100 transmitter 4...20 mA S6000
    Contextual Info: TRANSMICOR T243 series high temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE CABLEPROBE Main characteristics • Measuring range: 0 . 100 %rh, -30 . +140 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V 0 . 10V selectable with jumper ,


    Original
    Pt100 230VAC S6000 S6000, 1A04640, 11EXE 4/20mA, 0/20mA, 0/10V, 2/10V gefran 230 gefran pt100 PT100 temperature "Humidity Sensor" pt100 measurement pt100 sensor thin film PT-100 temperature sensor PT100 temperature sensor data sheet Pt100 transmitter 4...20 mA S6000 PDF

    Contextual Info: CX Dimming Option Card TITLE COMPLIANT CALIFORNIA CX Lighting Control Panels PROJECT INFORMATION 0-10V 24 DIM Project Name Catalog No. Date DIMMING The CX Dimming Option Card provides 0-10V dimming through any HBA CX Lighting Control Panel. This provides a low cost solution for lighting


    Original
    CX04/CX08 PDF

    gefran T220

    Abstract: PT100 4 wire temperature sensor T2202 transmicor T220 gefran pt100 T2201 Pt100 transmitter 4...20 mA pt100 temperature 3 wire PT100 3 wire temperature sensor PT100 2 wire temperature sensor
    Contextual Info: TRANSMICOR T220 SERIES RELATIVE HUMIDITY TRANSMITTER FOR HVAC Main characteristics • Measuring range: 0 . 98 %rh, -30 . +70 °C • Accuracy: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA 2 wire , 0 . 1V, 0 . 5V, 0 . 10V, 0 . 20mA (3 wire),


    Original
    Pt100 33VDC S6000 S6000, 1A04640, 4/20mA, 4/20mA gefran T220 PT100 4 wire temperature sensor T2202 transmicor T220 gefran pt100 T2201 Pt100 transmitter 4...20 mA pt100 temperature 3 wire PT100 3 wire temperature sensor PT100 2 wire temperature sensor PDF

    4 bis 20 mA stromquelle

    Abstract: programmierbare stromquelle Analog Microelectronics AM401 AM461 AN1013 DIL16 Spannungsregler
    Contextual Info: SPANNUNGS-VERSTÄRKER-IC AM401 PRINZIPIELLE FUNKTION Verstärkung und Wandlung von differentiellen und massebezogenen Signalen in einstellbare industrielle Spannungen 0.Vcc-5V, z.B. 0.5/10V usw. Variable Strom-/Spannungsquelle und integrierte Schutzfunktionen


    Original
    AM401 5/10V 400mV 5/10V AM401 AM461 AN1013 4 bis 20 mA stromquelle programmierbare stromquelle Analog Microelectronics AN1013 DIL16 Spannungsregler PDF

    cav424

    Abstract: AM400 4 bis 20 mA stromquelle VR10 MESSUMFORMER messverstarker
    Contextual Info: UNIVERSALES VERSTÄRKER–IC AM400 PRINZIPIELLE FUNKTION Verstärkung und Wandlung von differentiellen oder massebezogenen Eingangsspannungen in industrielle Standardstrom- 0/4.20mA oder Spannungssignale (z.B. 0.5/10V, 0,5.4,5V) VCC = 6…35V Eingangsspannung


    Original
    AM400 5/10V, 400mV 5/10V SSOP20 cav424 AM400 4 bis 20 mA stromquelle VR10 MESSUMFORMER messverstarker PDF

    AM401

    Abstract: circuit diagram "0-10V" industrial interface ANALOG MICROELECTRONICS circuit diagram of instrumentation amplifier converter ic voltage current Instrumentation Amplifier IC Power Analog Microelectronics variable voltage regulator AN1013 DIL16
    Contextual Info: INDUSTRIAL VOLTAGE AMPLIFIER IC AM401 PRINCIPLE FUNCTION Amplification and conversion of differential signals referenced to ground to adjustable industrial voltages 0.Vcc-5V, e.g. 0.5/10V etc. Variable current/voltage source and integrated protective circuitry


    Original
    AM401 5/10V 400mV 5/10V AM401: AN1013 AM401 circuit diagram "0-10V" industrial interface ANALOG MICROELECTRONICS circuit diagram of instrumentation amplifier converter ic voltage current Instrumentation Amplifier IC Power Analog Microelectronics variable voltage regulator DIL16 PDF

    Contextual Info: ypixxiyM 19-0381; Rev 0; 4/95 M ulti-Range ±10V, +5V, +10V, +5V , Single +5V, 12-Bit DAS w ith 8+4 Bus In te rfa c e Features 4 12-Bit Resolution, 1/2LSB Linearity ♦ Single +5V Operation ♦ Softw are-Selectable Input Ranges: ±10V, ±5V, OV to 10V, OV to 5V


    OCR Scan
    12-Bit 100ksps PDF

    ECG HEART BEAT SENSOR

    Abstract: FETAL HEART RATE MONITOR "Isolation Amplifier" ecg Model 284J fetal heartbeat transducer Fetal HEART BEAT monitor HEART BEAT SENSOR analog device 284J application note heart monitor
    Contextual Info: ANALOG DEVICES □ Economy, High Performance, Self Contained, Isolation Amplifier FEATURES Low Cost Low Nomlinearity: ±0.05% @ 10V pk-pk Output High Gain Stability: ±0.0075% /°C , ± 0 .0 0 i% /1 0 0 0 hours Isolated Power Supply: ± 8.5V dc @ ±5m A High CMR: IIO d B min with 5k£2 Imbalance


    OCR Scan
    4-20mA ECG HEART BEAT SENSOR FETAL HEART RATE MONITOR "Isolation Amplifier" ecg Model 284J fetal heartbeat transducer Fetal HEART BEAT monitor HEART BEAT SENSOR analog device 284J application note heart monitor PDF

    Contextual Info: discrete sensors photodarlington transistors OED-PT5063L40 Package Style Mmi T-5mm Leaded Black Resin ¿mMss of Safe Operation PC ’ t-opr (V Max (mW) Max Vtìèé 30 te (mA) @ EVf Min -40 m ~ + 85 (nA) Max 100 1 0 0 0 LX Vce (V) . Max — 100 (CEO @ 10V CEO


    OCR Scan
    OED-PT5063L40 Sfe1-B47-359-89D4 PDF

    STRAIN GAUGE

    Abstract: 0-200mV tare "strain gauge" 10VA V430 led digital panel amp volt meter isolated 4 to 20ma analog transmitter circuit visipak ohms meter panel
    Contextual Info: VISIPAKTM V434 Bridge/Strain Gauge Input, Digital Indicator Provides a Digital Display from Bridge & Strain Gauge mV Inputs Description Benefits Field Configurable Input Accepts 0-30mV, 0-200mV, + 15mV and +100mV Field Configurable Excitation Source 5V, 10V & 24VDC


    Original
    0-30mV, 0-200mV, 100mV 24VDC 004mA V434-0000 V434-1000 V434-2000 4-20mA V434-3000 STRAIN GAUGE 0-200mV tare "strain gauge" 10VA V430 led digital panel amp volt meter isolated 4 to 20ma analog transmitter circuit visipak ohms meter panel PDF

    gefran 230

    Abstract: gefran pt100 pt100 datasheet temperature transmitter pt100 2-10v PT100 temperature pt 100 sensor technical data PT100 4 wire temperature sensor pt100 sensor thin film sensor PT100 Pt100 transmitter 4...20 mA
    Contextual Info: TRANSMICOR T243 series low temperature RELATIVE HUMIDITY TRANSMITTER WITH REMOTE CABLE PROBE Main characteristics • Measuring range: 0 . 100 %rh, -30 . +85 °C • Précision: ± 2 %rh, ± 0,2 °C • Output signal: 4 . 20mA, 0 . 20mA, 2 . 10V


    Original
    Pt100 230VAC S6000 S6000, 1A04640, 133XA Pt100 24VAC, gefran 230 gefran pt100 pt100 datasheet temperature transmitter pt100 2-10v PT100 temperature pt 100 sensor technical data PT100 4 wire temperature sensor pt100 sensor thin film sensor PT100 Pt100 transmitter 4...20 mA PDF

    Leviton

    Abstract: EL7315A1019 SD4008-120 V2000FAMU avab Designer Series WPC-5721 ZP600FAM120 Occupancy Sensor LP-2800 LITHONIA LEQ
    Contextual Info: Advance Dimming Ballasts Control Compatibility Guide Advance Mark X Powerline and Mark VII® 0-10V Dimming Ballasts are Compatible with Controls from 30+ Manufacturers Occupancy Sensors Occupancy sensors automatically turn lights on/off or bring lights to


    Original
    EL-2010-AA-R01 Leviton EL7315A1019 SD4008-120 V2000FAMU avab Designer Series WPC-5721 ZP600FAM120 Occupancy Sensor LP-2800 LITHONIA LEQ PDF

    visipak

    Abstract: action instruments visipak 4-20ma DIGITAL CURRENT SOURCE V430-0000 V430-2000 V430 V430-3000 10VA 0-20mA 0.5V 4-20ma controller
    Contextual Info: VISIPAKTM V430 Analog Input, Rate Indicator/Totalizer/ Batch Controller Provides a Digital Display of Rate or Totalized Count from a DC Current or Voltage Input Description Benefits Field Configurable Input: 4-20mA, 1-5V, 0-5V, or 0-10V 6 Digit Display for Counts


    Original
    4-20mA, V430-0000 V430-1000 V430-2000 4-20mA V430-3000 115VAC 741-F 721-0695-00-F visipak action instruments visipak 4-20ma DIGITAL CURRENT SOURCE V430-0000 V430-2000 V430 V430-3000 10VA 0-20mA 0.5V 4-20ma controller PDF

    resistance to Current Converter 0-20mA

    Abstract: AD591 850il 4-20mA- 0-5 volt converter Voltage to Current Converter 0-20mA 3B13 AD592 3B14 220V AC to 5V DC transformer Voltage to Current Converter dual 4-20mA
    Contextual Info: 3B Series I/O Subsystems I_ I Input Module Selection Input Type/Span Voltage Output Current Output Nonisolated Modules Isolated Modules dc, ± lOmV, ± 50m V , ± lOOmV ±10V 4-20mA/0-20mA 3B10 3B30 dc, ± IV , ± 5V + 10V 4-20mA/0-20mA 3B10 3B31


    OCR Scan
    4-20mA/0-20mA 4-20mA, 0-20mA resistance to Current Converter 0-20mA AD591 850il 4-20mA- 0-5 volt converter Voltage to Current Converter 0-20mA 3B13 AD592 3B14 220V AC to 5V DC transformer Voltage to Current Converter dual 4-20mA PDF

    Contextual Info: AT42 Digital indicators 10.000 counts LED display RTD platinium sensor input Accuracy 1°C or 0.1°C Average value 2 set points Analog output 4-20mA or 0-10V Range -200°C to 450°C Meet the toughest requirements of electromagnetic compatibility standards EN 50081 and EN 50082


    Original
    4-20mA Q1060 PDF

    wieland cores PT100

    Abstract: signal conditioning circuit for pt100 4-20 mA rtd pt-100 amplifier circuit CORES-R100 signal conditioning circuit for pt100 wieland amplifer signal conditioning circuit pt100 PT100 DIN pt100 transistor PT100 temperature sensor 0-400
    Contextual Info: Temperature Measuring Amplifer for PT100 RTD’s with/without Alarm Output The narrow 19mm DIN rail mountable measuring amplifier, accepts a signal from a PT-100 sensor per DIN E C 751 and then linearizes, amplifies and adjusts it to a standard signal type e.g. 0.10V or


    OCR Scan
    PT100 PT-100 EN50081 wieland cores PT100 signal conditioning circuit for pt100 4-20 mA rtd pt-100 amplifier circuit CORES-R100 signal conditioning circuit for pt100 wieland amplifer signal conditioning circuit pt100 PT100 DIN pt100 transistor PT100 temperature sensor 0-400 PDF

    PCIR -A gefran

    Abstract: linear displacement sensor ic linear displacement transducer DIN EN 50035 gefran "Signal Conditioner" EN50035
    Contextual Info: PCIR SIGNAL CONDITIONER FOR LINEAR OR ROTATIVE DISPLACEMENT TRANSDUCERS Main features • • • • • • High impedance input >100 Mohm Voltage output 0.10V Linearity error < 0,02% full scale output Can be connected simultaneously to two transducers


    Original
    EN50035 EN50022 10Vdc 10Vdc. PCIR -A gefran linear displacement sensor ic linear displacement transducer DIN EN 50035 gefran "Signal Conditioner" PDF

    OPB9

    Contextual Info: 0 . OPTEK Product Bulletin OPB980 May 1993 Photologic Slotted Optical Switches Types OPB98Q, OPB99Q Series Features Absolute Maximum Ratings Ta = 25°C unless otherwise noted • • • • Supply Voltage, Vcc (Not to exceed 3 s e c .) . 10V


    OCR Scan
    OPB980 OPB98Q, OPB99Q 10OmW^ OPB9 PDF

    visipak

    Abstract: PT100 bridge example PT100 bridge design of a 4-20mA transmitter for a bridge type "environmental control system" EN50081-2 EN50082-2 pt100 active bridge 741 liquid point level sensor liquid level indicator instruments
    Contextual Info: VISIPAKTM V408 Universal Temperature/ Pressure/Process Indicator Provides a 5 Digit Display and Alarm Outputs from Thermocouple, RTD, Strain Gauge or DC Inputs Description Benefits Universal Field Configurable Input for TC, RTD, mV, bridge, 0-10V and 4-20mA Signals


    Original
    4-20mA 264VAC 741-F 721-0751-00-E visipak PT100 bridge example PT100 bridge design of a 4-20mA transmitter for a bridge type "environmental control system" EN50081-2 EN50082-2 pt100 active bridge 741 liquid point level sensor liquid level indicator instruments PDF

    IP710-DLX

    Abstract: 8-28VDC
    Contextual Info: Constant Voltage LED Dimmer E3X-D02FP - 315 MHz wireless w/ terminal block connections E9X-D02FL - 902 MHz wireless w/ flying lead connections NWO-D02FP - 0-10V controlled PWM dimmer no wireless capability Ultra Smooth LED Dimming •■ Architectural dimming


    Original
    E3X-D02FP E9X-D02FL NWO-D02FP ExX-D02Fy) E3X-D02FP- AHD0211F IP710-DLX 8-28VDC PDF