Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    .37 KW MOTOR Search Results

    .37 KW MOTOR Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    COMBOMOTOR
    Texas Instruments AMC1200 4kV peak Isolated Amplifier for Current Shunt Measurements Visit Texas Instruments

    .37 KW MOTOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    PKZM4-58

    Abstract: pkzm4 VDE 0660 IP 65
    Contextual Info: Type: PKZM4−58 Article No.: 222394 Ordering information Connection technique Screw terminals Motor rating AC−3 220 V 230 V 240 V P kW 17 Motor rating AC−3 380 V 400 V 415 V P kW 30 Motor rating AC−3 440 V P kW 37 Motor rating AC−3 500 V P kW 37 Motor rating AC−3 690 V


    Original
    PKZM4-58 D-53115 HPL-C2006GB-INT PKZM4-58 pkzm4 VDE 0660 IP 65 PDF

    PKZM4-63

    Abstract: Moeller PKZM4-63
    Contextual Info: Type: PKZM4−63 Article No.: 222413 Ordering information Connection technique Screw terminals Motor rating AC−3 220 V 230 V 240 V P kW 18.5 Motor rating AC−3 380 V 400 V 415 V P kW 34 Motor rating AC−3 440 V P kW 37 Motor rating AC−3 500 V P kW 45


    Original
    PKZM4-63 D-53115 HPL-C2006GB-INT PKZM4-63 Moeller PKZM4-63 PDF

    230V 5A OMRON Auxiliary RELAY

    Abstract: star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030
    Contextual Info: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 37 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    380/415V) omron247 J06E-EN-01A 230V 5A OMRON Auxiliary RELAY star delta wiring diagram with pneumatic timer 220-240v varistor 230V 5A OMRON RELAY NC Contacts J73KN-b-01 transformer winding formula 220v Ac to 110v Ac 3phase winding data 3.7 kw to 110 kw J7KN-14-10 AC415-440V timer omron J74KN-LG-9030 PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: feeder J74-WKR-B J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24
    Contextual Info: Motor Contactor J7KN • Range from 4 to 500 kW AC 3, 380/415 V • AC and DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting (35 mm DIN rail) upto 37 kW • Compliant to the global standards • Finger proof (BGV A2) • System contactors for Fuseless Load Feeders with integrated


    Original
    J74KN-C-RC J74KN-B-RC J74KN-LG-9030 J74KN-LG-11224 J74KN-LG-10404 J74KN-LG-11457 J74KN-P J74-WKR-B J74-WKR-C J74-WKSD-B 3phase winding data 3.7 kw to 110 kw feeder J7KN24 DOL reversing wiring diagram motor J7KNG-22-4 wiring diagram 3 phase dol compressor magnetic Contactor wiring diagrams J7KN14-01 J74KN-C-RC24 PDF

    ACS100-PAN

    Abstract: acs-chk-c abb acs 101 NPBA-02 PEC-98-0008 SACL22 NOCH-0070-6X NCAN-02 334 te 2395 acs 143
    Contextual Info: Technical Catalogue Instant ordering and advice Low power AC drives 0.12 kW - 37 kW Easy to pay, most credit cards accepted Fast delivery within hours Simple documentation easy to read Support line 2 year worldwide warranty ABB Automation 1 Nobody looks after you better. Every drive you buy comes with


    Original
    R0225 ACS100-PAN acs-chk-c abb acs 101 NPBA-02 PEC-98-0008 SACL22 NOCH-0070-6X NCAN-02 334 te 2395 acs 143 PDF

    rj12 rs485

    Abstract: 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM RJ12 to RS485 edr40 RJ12 connector
    Contextual Info: Prices as of April 16, 2014. Check Web site for most current prices. DURApulse AC Drives – Introduction DURApulse Drives Motor Rating Hp 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 kW .75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Single/Three-Phase Input 230V 4 4 4


    Original
    230VClass RS-485 SJ100-055HFU GS2-47P5 GS3-47P5 SJ100-075HFU GS2-4010 GS3-4010 eDR-95 rj12 rs485 10 HP CAPACITOR START SINGLE PHASE motor WIRING DIAGRAM RJ12 to RS485 edr40 RJ12 connector PDF

    pst44

    Abstract: PSTB720-600-70 PSTB470-600-70 PSTB570-600-70 PST250-600-70 PSTB370-600-70 1SFT98000-012C3 DNP21-FBP PST72-600-70 PSS25-400B
    Contextual Info: Mykstartere Type PSS Type PST/PSTB - New range Ny 1SFC132016F0201 Katalog 1SEC132001C2101, Juli 2003 PSS03 . PSS25 For normal starts Operator panels Application PSS25 The softstarter types PSS03 . PSS25 are compact solutions for small motors. It is easy to install and to adjust as access for connections and


    Original
    1SFC132016F0201 1SEC132001C2101, PSS03 PSS25 PSS25 PSS12 pst44 PSTB720-600-70 PSTB470-600-70 PSTB570-600-70 PST250-600-70 PSTB370-600-70 1SFT98000-012C3 DNP21-FBP PST72-600-70 PSS25-400B PDF

    LC1 D09 10

    Abstract: LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09
    Contextual Info: TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.


    Original
    D12pp kW/400 24503-EN LC1 D09 10 LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09 PDF

    194E-A125-1754

    Abstract: 194E-A250-1753 194E-B250-1753 194E 194E-E125-1753 DC22A 194ehe8g175 194E-A160-1753 194E-AB AC21A
    Contextual Info: IEC Load Switches Bulletin 194E 125 Amps to 315 Amps Features • • • • • • • • • • Description Bulletin 194E load switches are designed for use in North America as local motor isolation and for IEC disconnect switch applications outside of North America. Available in 3- and 4-pole versions with


    Original
    194Es 194E-HE-8A-8I-8G-8N) 194E-HE-13A-13I-13G-13N) G3515 194E-A125-1754 194E-A250-1753 194E-B250-1753 194E 194E-E125-1753 DC22A 194ehe8g175 194E-A160-1753 194E-AB AC21A PDF

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Contextual Info: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09 PDF

    bva04

    Abstract: D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09
    Contextual Info: TeSys enclosed starters Characteristics, references 2 2 D.O.L. starters for motor control 1 2.2 to 45 kW, with isolating device Characteristics Conforming to standards IEC 60947-4-1 and IEC 60439-1, VDE 0660-102, EN 60947 Ambient air temperature IP 659: LEp K


    Original
    D09907 D09F7A04. 24103-EN bva04 D656 tesys d contactors K065 D406 D806 M7230 IEC 60439-1 start return ac motors LE4-D09 PDF

    DIL00AM

    Abstract: DIL4M115 DIL3AM85 dil00m DIL4AM145 DIL00BM-10 DIL00M-10 DIL00M-G dil3m80 DIL2AM-G
    Contextual Info: I06_012-013_b_gb.fm Seite 12 Dienstag, 18. März 2003 1:27 13 6/12 Moeller HPL0211-2003/2004 3-pole Screw terminals DIL contactors 3-pole, 4-pole basic units Rated operational current AC-3 380 V 400 V Ie A Max. rating for three-phase motors, 50 – 60 Hz AC-3


    Original
    HPL0211-2003/2004 DIL3M80 24VDC) DIL3AM85 DIL4M115 230V50HZ) DIL4AM145 DIL00AM dil00m DIL00BM-10 DIL00M-10 DIL00M-G DIL2AM-G PDF

    LC2 contactor

    Abstract: LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150
    Contextual Info: References TeSys contactors 5 5 Reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 810369 3-pole reversing contactors for connection by screw clamp terminals or connectors


    Original
    24503-EN LC2 contactor LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150 PDF

    22-HIM-A3

    Abstract: AK-R2-360P500 22-HIM-C2S 20AC015A0AYNANC0 22A D4P0N104 Powerflex User Manual wireless 3-phase starter using rf technology wireless 3-phase motor starter using RF technology 20b-enc-1 22F-A4P2N103 140M-F8E-C45
    Contextual Info: SELECTION GUIDE POWERFLEX AC DRIVES THE INTELLIGENT MOTOR CONTROL SOLUTION FOR YOUR APPLICATION REQUIREMENTS AUTOMOTIVE BREWING BEVERAGE FOOD PACKAGING PHARMACEUTICAL PETROCHEMICAL WATER WASTEWATER MINING AGGREGATE CEMENT OIL & GAS PRINTING & PUBLISHING


    Original
    PFLEX-SG102E-EN-P PFLEX-SG102D-EN-P 22-HIM-A3 AK-R2-360P500 22-HIM-C2S 20AC015A0AYNANC0 22A D4P0N104 Powerflex User Manual wireless 3-phase starter using rf technology wireless 3-phase motor starter using RF technology 20b-enc-1 22F-A4P2N103 140M-F8E-C45 PDF

    LC1-D50A

    Abstract: LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12
    Contextual Info: Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility . so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify


    Original
    LC1-F630, F6304 LC1-F500 F5004 LC1-F400 F4004 LC1-D50A LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12 PDF

    siemens soft starter 3rw44

    Abstract: Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0
    Contextual Info: Siemens AG 2008 Dynamics Reinterpreted The Comprehensive Range of SIRIUS Soft Starters www.siemens.com/softstarter © Siemens AG 2008 The Ideal SIRIUS Soft Starter for All Applications Today, three-phase motors serve as the ultimate drive concept. Yet, for many


    Original
    E20001-A1040-P302-X-7600 21C/9315 siemens soft starter 3rw44 Sirius 3Rv siemens star delta starter 3RW44 siemens soft starter Sirius 3RW40 3RW4900-0KC00 star delta motor starter with siemens contactor 3RW444 3UF7940-0AA00-0 PDF

    50 KW dc motor

    Abstract: 3 Kw ac motor control 90 KW motor 15 kw series dc motor IEC 60947-3 MOELLER
    Contextual Info: Type: T5B−1−8210/I4 Article No.: 207432 With black thumb−grip and grey front plate Ordering information Design Surface mounting Description With 0 Off position No. of poles M 1 Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415


    Original
    T5B-1-8210/I4 T8-3-8342/. AC-21A D-53115 HPL-C2006GB-INT 50 KW dc motor 3 Kw ac motor control 90 KW motor 15 kw series dc motor IEC 60947-3 MOELLER PDF

    AC-21A

    Contextual Info: Type: P3−63/I4 Article No.: 207356 Ordering information Design Surface mounting Description Without auxiliary contacts Main conducting paths No. of poles M 3 Auxiliary contacts N/O Auxiliary contacts B Max. three−phase motor rating per set of 3 contacts 50−60 Hz AC−3 400/415


    Original
    P3-63/I4 AC-21A D-53115 HPL-C2006GB-INT PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Contextual Info: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v PDF

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Contextual Info: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor PDF

    2090-XXNFMF-Sxx

    Abstract: servo srm 102 2090-CDNFDMP-Sxx 2090-K6CK-D15M DIN748 SNS-60 8720SM 2090-K6CK 12v DC geared motor 12v 30 RPM DC geared motor
    Contextual Info: Technical Data 8720SM Motor Conversions Catalog Numbers 8720SM-005, 8720SM-007, 8720SM-011, 8720SM-015, 8720SM-018, 8720SM-022, 8720SM-030, 8720SM-037, 8720SM-045, 8720SM-055, 8720SM-063, 8720SM-075, 8720SM-093 Topic Page About This Publication 2 About Converting from 8720SM Motors


    Original
    8720SM 8720SM-005, 8720SM-007, 8720SM-011, 8720SM-015, 8720SM-018, 8720SM-022, 8720SM-030, 8720SM-037, 8720SM-045, 2090-XXNFMF-Sxx servo srm 102 2090-CDNFDMP-Sxx 2090-K6CK-D15M DIN748 SNS-60 2090-K6CK 12v DC geared motor 12v 30 RPM DC geared motor PDF

    star-delta starting motors

    Abstract: Moeller P1-32 moeller dol starters T5B-4-15682 T3-4-15682 p1-32 i2 svb moeller SDAINLM70 SDAINLM115 dol starter ip65 Moeller SDAINLM12
    Contextual Info: www.moeller.co.uk Enclosed Motor Starters & Isolators Short Form Catalogue A We keep power under control. 2 Enclosed motor starters and isolators Contents Contents Enclosed motor starters Direct-on-line – compact 3 4 Direct-on-line – insulated enclosures


    Original
    21-270GB star-delta starting motors Moeller P1-32 moeller dol starters T5B-4-15682 T3-4-15682 p1-32 i2 svb moeller SDAINLM70 SDAINLM115 dol starter ip65 Moeller SDAINLM12 PDF

    siemens sirius 3r

    Abstract: a/3RV10
    Contextual Info: 3RT10 Contactors for Switching Motors SIRIUS 3R Technical data s and u ratings of the contactors Contactor Size Type AC V Rated insulation voltage Conventional thermal current Free air and enclosed Maximum horsepower ratings s and u-approved values Ratings


    Original
    3RT10 siemens sirius 3r a/3RV10 PDF

    yaskawa ERF150WJ

    Abstract: ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ
    Contextual Info: Y203-EN2-02-Katalog.book Seite 289 Mittwoch, 24. Mai 2006 2:22 14 CIMR-L7Z Varispeed L7 Made to drive lifts • • • • • • • • • • • • • • • • • One model to control AC and PM motors. Silent operation with no current de-rating.


    Original
    Y203-EN2-02-Katalog EN81-1 I22E-EN-02 yaskawa ERF150WJ ERF 2030 45 KW 3-phase motor weight ERF-150WJ ERF150WJ PDF