The Datasheet Archive

78+los Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
1996 - 7824 n3

Abstract: UC 3854 digital power ATM25 PE-67588 TLA-6M102 4-12PHY PHA50
Text: .32 .33 3.2 TC . 3.2.1 LOS .33 3.2.2 NRZI .33 3.2.3 .34 3.2.4 4B5B .34 3.2.5 , .41 3.5 CPU.42 3.5.1 .43 3.5.2 .44 3.6 .45 3.7 .45 3.7.1 LOS .45 3.7.2 HEC 4B5B , .52 4.2.2 CMR.53 4.2.3 PHY PICR.54 4.2.4 PHY PIMR.56 4.2.5 DCCOU.57 4.2.6 LOS LOSERR.58 4.2.7 LOS LOSMSK.59 10 4.2.8 PMD 1 LBPMDT.60 4.2.9 PMD 2 LBPMDU.61 4.2.10ATM LBATM , Rx 32 3 3.2TC 3.2.1 LOS Loss Of Signal 3.7.1LOS 3.2.2 NRZI NRZ


Original
PDF PD98408 T20TM S11409JJ3V0UM00 NEASCOT-T20 24NEC 7824 n3 UC 3854 digital power ATM25 PE-67588 TLA-6M102 4-12PHY PHA50
2014 - Not Available

Abstract: No abstract text available
Text: Sencilla personalización Todos los instrumentos de la CombiSeries pueden funcionar con la , el rango de medición y la unidad, la atenuación, los valores de alarma, los valores de ajuste de los relés, el diseño de la pantalla y realizar otros ajustes. Con respecto al transmisor de , competencia de Baumer adquirida a lo largo de muchos años en el ámbito de los instrumentos de medición de , ideal para la utilización en los procesos CIP y SIP, para monitorizar las concentraciones en líquidos


Original
PDF CH-8501 ES-08021
1999 - TI-30X

Abstract: No abstract text available
Text: ¿Cuál es mi puntaje? -Estadística de 1 variable Conceptos generales Los estudiantes usan los , cálculo del promedio a los estudiantes Actividad Presente el siguiente problema a los estudiantes: Usted y un amigo compiten en un concurso. El que obtiene el mayor promedio en los exámenes de matemáticas en un trimestre gana. Sus puntajes son 98, 89, 78, 98 y 100. Los puntajes de su amigo son 89, 89, 97, 90 y 100. ¿Quién es el ganador? Procedimiento 1. Indique a los estudiantes que calculen el


Original
PDF TI-30X TI-30X
1997 - Not Available

Abstract: No abstract text available
Text: signal levels and consecutive pulse period conditions. With reference to declaring the LOS Condition, it , consecutive pulse intervals, where ìí 1 ëèè, a LOS must be declared.î In discussing clearing the LOS , tolerance range, either LOS or clear from LOS is acceptable. However, the transceiver must declare LOS if the signal level falls below Q dB. The receiver must clear the LOS Condition above P dB if the , falls below 20 dB, the LXT304A1 begins to count consecutive bit times and declares LOS after


Original
PDF
2006 - Not Available

Abstract: No abstract text available
Text: detect - Hysteresis Wavelength of Operation Electrical Differential Output Voltage Output LOS Voltage - Low Output LOS Voltage - High Symbol Sens Pin Pa Pd Min Typ Max -34 -10 -47 1.0 1100 0.6 0 2.0 -34 , TX Txdisable Mod_def(2) Mod_def(1) Mod_def(0) Rate select RX Los VeeR VeeR 1 2 3 4 5 6 7 8 9 10 , - SFP module depend on customer's PHY To I2C Bus Vcc3.3V 10K Los Of Signal , LOS RX GND RX GND Description Transmitter Ground Transmitter Fault Indication Transmitter Disable


Original
PDF SPS-33120W-CXX0 SPS-33120W-CXX0
2004 - Not Available

Abstract: No abstract text available
Text: detect - Hysteresis Wavelength of Operation Electrical Differential Output Voltage Output LOS Voltage - Low Output LOS Voltage - High Symbol Sens Pin Pa Pd Min Typ Max -34 -10 -47 1.0 1100 0.6 0 2.0 -34 , Txdisable Mod_def(2) Mod_def(1) Mod_def(0) Rate select RX Los VeeR VeeR 1 2 3 4 5 6 7 8 9 10 VeeT TDTD , - SFP module depend on customer's PHY To I2C Bus Vcc3.3V 10K Los Of Signal , LOS RX GND RX GND Description Transmitter Ground Transmitter Fault Indication Transmitter Disable


Original
PDF SFF-8472 IEC-60825 SPS-33120W-CXX0 SPS-33120W-CXX0
4B5B

Abstract: PE-67588 TLA-6M102 PTC TDK rj45 Magnetics
Text: S14838JJ1V0IF00 1 .11 Q.1 UTP/STP .11 Q.2 LOS .11 Q.3 µ PD98408 .12 Q , PD98408UM2.2 Q.2 LOS A.2 µ PD98408 LOS LOS 224 µs LOS LOSERRLOS LSn = 0LOS µ , LOS µ PD98408UM3.1.3 Q.4 µ PD98408 X_8 SIN X_8 A.4 SIN 32 MHz TCLOCK24 34 X_8 µ


Original
PDF PD98408Q NEASCOT-T20 S14838JJ1V0IF00 S14838JJ1V0IF00 FAX044548-7900 4B5B PE-67588 TLA-6M102 PTC TDK rj45 Magnetics
PILZ PNOZ m1p

Abstract: PILZ PNOZ mc3p PILZ PNOZ X1 PILZ pnoz m1p error reset PILZ PNOZmulti configurator 9 pilz pnoz 1 pnoz m1p PILZ pnoz m1p error Profibus pilz PNOZ EXAMPLE CONEXION
Text: los valores indicados en la sección "Datos técnicos". · Durante el transporte, almacenaje y , alimentación durante los trabajos de mantenimiento. Es estrictamente necesario que observe las indicaciones , información de entrada de los esclavos y escribe cíclicamente la información de salida a los esclavos , Functiebeschrijving Modo de trabajo: Los datos a transmitir mediante el PROFIBUS-DP se seleccionan y configuran , : Los LEDs indican el estado del módulo de ampliación PNOZ mc3p en el PROFIBUS-DP. Funzioni: I LED


Original
PDF
1999 - LIBROS ELECTRONICA

Abstract: virge conversiones LIBROS us79 TI-30X M270 F0123456789 teclado Matematicas para maestros
Text: Jay Garrison Acerca de los autores Gary Hanson y Aletha Paskett son profesores de matemáticas del , la evaluación de la aptitud de los ejemplos en la sección Cómo usar la calculadora TI-30X ÖS de esta guía. Aviso importante sobre el material didáctico En relación con los programas y materiales , -30X ÖS pueden arrojar resultados distintos a los descritos en estos materiales. Autorización para , los sistemas de almacenamiento o recuperación de información. Puede enviar sus preguntas a la


Original
PDF TI-30X TI-30X TI-30XII 30XII/TG/2L1/B LIBROS ELECTRONICA virge conversiones LIBROS us79 M270 F0123456789 teclado Matematicas para maestros
2001 - GVIF

Abstract: GVIF cable 18bit TTL 40 pins lcd to 15 pins vga 30 pin xga lcd connector to vga connector QFP080-P-1414 CXB1452Q CXB1451Q 2SK303 QFP Package 80 lead
Text: ) RED0 (2) RED0 (1) VCCT RED0 (0) VEET 80 pin QFP (Plastic) LOS REFRQP SDATAP , switch LOS 50 TTL out Los of signal SDATAP/N 52, 53 Rx Serial input REFRQP/N , circuit SFTCLK, LOS (b') TTL output equivalent circuit REDxx, GRNxx, BLUxx, H/V sync, CNTLx VCCA , µs CLOCK mode deassert time TDclk 50 µs LOS signal assert time TAlos 0.8 µs LOS signal deassert time TDlos 0.1 µs ­5­ CXB1452Q VCCA/G/T TTLout Cprobe


Original
PDF CXB1452Q 18bit 80pin PANEFP080-P-1414 42/COPPER QFP-80P-L03 QFP080-P-1414 GVIF GVIF cable 18bit TTL 40 pins lcd to 15 pins vga 30 pin xga lcd connector to vga connector QFP080-P-1414 CXB1452Q CXB1451Q 2SK303 QFP Package 80 lead
1999 - XRT84V24

Abstract: XRT84V24IV-160 XRT84V24IV-208 E1 frame
Text: Alarms · Detects LOF, COFA and LOS conditions · Each Framer Contains a 512 bit Elastic Store Buffer · , REV. 1.0.1 FIGURE 2. P IN OUT OF THE XRT84V24 IN THE 160 PIN PQFP PACKAGE LOS _0 TxPOS_0 TxNEG_0 TxLineClk_0 RxPOS_0 RxNEG_0 RxLineClk_0 LOS _1 GND TxPOS_1 TxNEG_1 TxLineClk_1 RxPOS_1 RxNEG , _0_SDO VDD RxLineClk_2 RxNEG_2 RxPOS_2 TxLineClk_2 TxNEG_2 TxPOS_2 GND LOS _2 RxLineClk_3 RxNEG_3 RxPOS_3 TxLineClk_3 TxNEG_3 TxPOS_3 LOS _3 NC 160 Lead PQFP 120 119 118 117 116 115 114


Original
PDF XRT84V24 XRT84V24 XRT84V24IV-160 XRT84V24IV-208 E1 frame
1998 - Not Available

Abstract: No abstract text available
Text: Customer Education Services Class Schedule: North America 1998 through June 1999 DEC. 8-9 JAN. 6-7 7-8 20-21 FEB. 8-9 3-4 FPGA Tools Courses (2 days) LOCATIONS Huntsville, AL Phoenix, AZ San Jose, CA - Xilinx, Inc. Los Angeles, CA Irvine, CA San Diego, CA Toronto, Ontario, Canada Orlando, FL Boston, MA Raleigh, NC Fairfield, NJ Long Island, NY Houston, TX Dallas, TX , Courses (1 day) LOCATIONS Huntsville, AL Phoenix, AZ San Jose, CA Irvine, CA Los Angeles, CA San Diego


Original
PDF
2001 - GVIF connector

Abstract: GVIF
Text: ) LOS GRN1 (4) GRN1 (2) RED1 (4) RED1 (3) RED1 (2) BLU1 (0) BLU1 (1) VCCT , ) GRN0 (5 to 0) BLU0 (5 to 0) HSYNC VSYNC CNTL (3 to 0) PANEL (1, 0) CKMODE LOS SDATAP/N REFRQP/N 72 14 , Clock mode select switch Los of signal Serial input Refclk request TTL out TTL out TTL out TTL out , VCCT 3k VCCT TTL-OUT TTL-OUT VEET VEET (b) TTL output equivalent circuit SFTCLK, LOS VCCA , CLOCK mode deassert time LOS signal assert time LOS signal deassert time Torc Tofc Tord Tord TAclk


Original
PDF CXB1452Q 18bit 80pin QFP-80P-L03 QFP080-P-1414 42/COPPER GVIF connector GVIF
2004 - LCP-1250A4FSM

Abstract: LCP-1250B4QSM EN-60825-2 LCP-1250A4FS LCP-1250Axxx
Text: or up to 220m in 62.5/125um MMF The post-amplifier of the LCP-1250xxxxx also includes a LOS LCP , Output Voltage VDR LOS Output Voltage-High VLOSH LOS Output Voltage-Low VLOSL Output Data Rise/Fall , Wavelength 850 nm LOS - De-Asserted (Avg.) PD -17 dBm LOS - asserted (Avg.) PA -30 dBm , Select LOS VeeR VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Module Definition 2 Module , interface for serial ID 4) LOS (Loss of Signal) is an open collector/drain output, which should be


Original
PDF LCP-1250xxxxx LCP-1250A4FSM LCP-1250B4QSM LCP-1250B4LSM LCP-1250D4MSM LCP-1250D4WSM LCP-1250D4RSM LCP-1250B4QSM 0625GBd 100-SM-LC-L LCP-1250A4FSM EN-60825-2 LCP-1250A4FS LCP-1250Axxx
2002 - ao6418

Abstract: 24 port liu 6 PORT LIU E2 liu TVSS logos/INTEL DB2 LXT3108 M68302 M68360 MPC860
Text: . 60 13.3.1 Loss Of Signal ( LOS ). 60 13.3.1.1 Operation of USER LOS with Amplitude Detection . 62 13.3.1.2 Operation of USER LOS with Marks Density Detection. 62 13.3.2 Alarm , . 53 LOS Criteria for Intel® LXT3108 LIU . 61 LOS Register Configurations


Original
PDF LXT3108 LXT3108 ao6418 24 port liu 6 PORT LIU E2 liu TVSS logos/INTEL DB2 M68302 M68360 MPC860
2005 - scp6f14

Abstract: sumitomo sfp SCP6* SFP
Text: Interface AC coupled for DATA, LVTTL for Tx Disable and open collector output for LOS and Tx Fault. Circuit , RD- 100 LOS Temperature Supply voltage Tx bias current Tx output power Rx received power , 13 12 11 MOD-DEF(1) VccR 6 7 8 9 10 MOD-DEF(0) VeeR NUC RD+ LOS RDVeeR VeeR VeeR 17 18 19 20 , 1 6 MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of signal indication 9 VeeR , of two wire serial interface for serial ID. LOS RD LOS is an open collector output that shall be


Original
PDF TS-S05D013A 1250Mbps) SCP6F14-GL-# SCP6F74-GL-# SCP6F94-GL-# 1310nm, 1550nm, SCP6F14, SCP6F74 scp6f14 sumitomo sfp SCP6* SFP
2006 - ieee802.3 rise time fall time

Abstract: scp6f14 electronic eye automatic alarm sumitomo sfp
Text: Interface AC coupled for DATA, LVTTL for Tx Disable and open collector output for LOS and Tx Fault. Circuit , RD- 100 LOS Temperature Supply voltage Tx bias current Tx output power Rx received power , 13 12 11 MOD-DEF(1) VccR 6 7 8 9 10 MOD-DEF(0) VeeR NUC RD+ LOS RDVeeR VeeR VeeR 17 18 19 20 , 1 6 MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of signal indication 9 VeeR , of two wire serial interface for serial ID. LOS RD LOS is an open collector output that shall be


Original
PDF TS-S05D013E 1250Mbps) SCP6F14-GL-# SCP6F64-GL-# SCP6F74-GL-# SCP6F94-GL-# 1310nm, 1550nm, ieee802.3 rise time fall time scp6f14 electronic eye automatic alarm sumitomo sfp
1997 - CXB1452Q

Abstract: GVIF cable CXB1452 ttl to vga connector 18bit digital ttl rgb to analog vga 1PPC VGA decoder circuit QFP080-P-1414 CXB1451Q 2SK303
Text: ) RED0 (2) RED0 (1) VCCT RED0 (0) VEET 80 pin QFP (Plastic) LOS REFRQP SDATAP , switch LOS 50 TTL out Los of signal SDATAP/N 52, 53 Rx Serial input REFRQP/N , circuit REDxx, GRNxx, BLUxx, H/V sync, CNTLx (b) TTL output equivalent circuit SFTCLK, LOS VCCA , µs CLOCK mode deassert time TDclk 50 µs LOS signal assert time TAlos 0.8 µs LOS signal deassert time TDlos 0.1 µs ­5­ CXB1452Q VCCA/G/T TTLout Cprobe


Original
PDF CXB1452Q 18bit 80pin 65Mb/s 10dB/ 50MHz 100kHz 00MHz CXB1452Q GVIF cable CXB1452 ttl to vga connector 18bit digital ttl rgb to analog vga 1PPC VGA decoder circuit QFP080-P-1414 CXB1451Q 2SK303
SCP6G94

Abstract: SCP6G74 scp6g14 SCP6G74-GL SCP6G94-GL SFP finisar 80km SCP6G SCP6G14/SCP6G74/SCP6G94-GL sumitomo sfp TS-S08D003G
Text: for DATA, LVTTL for Tx Disable and open collector output for LOS and Tx Fault. Circuit ground is , 10k LOS Diagnostic Monitor Vcc 4.7k to 10k MOD- DEF (0) EEPROM MOD- DEF (1) MOD , 15 VeeR 6 14 MOD-DEF(0) 7 NUC 8 Towards ASIC LOS RD+ 12 VeeR , MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of signal indication 9 VeeR , data line of two wire serial interface for serial ID. LOS LOS is an open collector output that


Original
PDF TS-S08D003G 1250Mbps) SCP6G14-GL-# 1310nm, SCP6G74-GL-# 1550nm, SCP6G94-GL-# SCP6G14/SCP6G74/SCP6G94-GL) SCP6G94 SCP6G74 scp6g14 SCP6G74-GL SCP6G94-GL SFP finisar 80km SCP6G SCP6G14/SCP6G74/SCP6G94-GL sumitomo sfp TS-S08D003G
2006 - Not Available

Abstract: No abstract text available
Text: for LOS and TxFault. Circuit ground is internally isolated from frame ground. Distance <10km (SMF) *1 , Amplifier RD- 100 LOS Temperature Supply voltage Tx bias current Tx output power Rx received power , (2) VccT 16 15 14 13 12 11 MOD-DEF(1) VccR 6 7 8 9 10 MOD-DEF(0) VeeR NUC RD+ LOS RDVeeR VeeR VeeR 17 , Module definition 1 6 MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of signal , is the data line of two wire serial interface for serial ID. LOS RD LOS is an open collector output


Original
PDF TS-S06D149A SCP6F46-GL- 52Mb/s 08Mb/s 5/1250/2125Mbps SCP6F46-GL)
2008 - SCP6G94

Abstract: SCP6G74-GL SCP6G14/SCP6G74/SCP6G94-GL
Text: for DATA, LVTTL for Tx Disable and open collector output for LOS and Tx Fault. Circuit ground is , 4.7k to 10kΩ LOS Diagnostic Monitor Vcc 4.7k to 10kΩ MOD- DEF (0) EEPROM MOD , ASIC LOS RD+ 12 VeeR 9 11 VeeR 10 13 RD- VeeR Figure 3. Pin , MOD-DEF1 Module definition 1 6 MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of , serial ID. MOD-DEF2 is the data line of two wire serial interface for serial ID. LOS LOS is an open


Original
PDF TS-S08D003D 1250Mbps) SCP6G14-GL-# 1310nm, SCP6G74-GL-# 1550nm, SCP6G94-GL-# SCP6G94 SCP6G74-GL SCP6G14/SCP6G74/SCP6G94-GL
2008 - sumitomo sfp gbe

Abstract: SCP6F44 E240442 10kohm resistor sumitomo electrical sfp ieee802.3 document electronic eye automatic alarm section38 scp6f44-gl e2404
Text: interface AC coupled for DATA, LVTTL for TxDisable and open collector output for LOS and TxFault. Circuit , 10k Receiver PD RD+ Pre Amplifier Post Amplifier RD- 100 LOS Temperature , 10 MOD-DEF(0) VeeR NUC RD+ LOS RDVeeR VeeR VeeR 17 18 19 20 Towards Bezel 5 Towards ASIC , definition 0 7 NUC No user connection 8 LOS Loss of signal indication 9 VeeR Receiver ground 10 VeeR Receiver , ID. LOS RD LOS is an open collector output that shall be pulled up with a 4.7k to 10kohm resistor


Original
PDF TS-S04D175I SCP6F44-GL- 52Mb/s 08Mb/s SCP6F44-GL) sumitomo sfp gbe SCP6F44 E240442 10kohm resistor sumitomo electrical sfp ieee802.3 document electronic eye automatic alarm section38 scp6f44-gl e2404
2005 - GR-1244-CORE

Abstract: GR-253-CORE IPC-SM-782 Si5318
Text: VDD GND Biasing & Supply Regulation FXDDELAY CLKIN+ CLKIN­ VALTIME LOS CAL_ACTV 2 ÷ , (C L K IN ­ ) 0 V tLOS Figure 3. Transitionless Period on CLKIN for Detecting a LOS Condition , Transitionless Period Required on CLKIN for Detecting a LOS Condition. INFRQSEL[2:0] = 001 INFRQSEL[2:0] = , Recovery Time for Clearing an LOS Condition VALTIME = 0 VALTIME = 1 tVAL Figure 3 4 Measured from when a valid reference clock is applied until the LOS flag clears 8 /fo_155 8 /fo_155 8


Original
PDF Si5318 GR-253-CORE OC-48 Si5318 GR-1244-CORE IPC-SM-782
2009 - SCP6G44-GL-xWx

Abstract: SCP6G44 SCP6G44-GL 6F45 sumitomo sfp sumitomo electrical sfp ATMEL Damp heat AT AT24C01A SCP6G sumitomo sfp gbe
Text: TxDisable and open collector output for LOS and TxFault. Circuit ground is internally isolated from frame , (2) MOD-DEF(1) VccR 15 VeeR 6 14 MOD-DEF(0) 7 NUC 8 LOS RD+ 11 , MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of signal indication 9 VeeR , . MOD-DEF2 is the data line of two wire serial interface for serial ID. LOS LOS is an open collector , Tx Disable. 4. For LOS and TxFault. ! Warning ! Use the product with the rated voltage


Original
PDF TS-S07D086D SCP6G44-GL-xWx 52Mb/s 08Mb/s SCP6G44-GL) SCP6G44-GL-xWx SCP6G44 SCP6G44-GL 6F45 sumitomo sfp sumitomo electrical sfp ATMEL Damp heat AT AT24C01A SCP6G sumitomo sfp gbe
2008 - SCP6G44-GL-xWx

Abstract: SCP6G44 SCP6G44-GL
Text: for DATA, LVTTL for TxDisable and open collector output for LOS and TxFault. Circuit ground is , NUC 8 LOS RD+ 11 VeeR VeeR Figure 3. Function 12 VeeR 9 10 13 RD , MOD-DEF1 Module definition 1 6 MOD-DEF0 Module definition 0 7 NUC No user connection 8 LOS Loss of , ID. LOS LOS is an open collector output that shall be pulled up with a 4.7k to 10kohm resistor , . 2. peak value 3. For MOD-DEF (1:2) and Tx Disable. 4. For LOS and TxFault. ! Warning !


Original
PDF TS-S07D086C SCP6G44-GL-xWx 52Mb/s 08Mb/s SCP6G44-GL) SCP6G44-GL-xWx SCP6G44 SCP6G44-GL
Supplyframe Tracking Pixel