4-20 mA converter modbus rs485 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
M54020 circutor

Abstract: m50730 M54410 M54020 M51B11 M51231 CVM-BD-RED-C420-H profibus vs. modbus M50790 LM50-TCP
Text: Converter of RS-232 / 485 to Ethernet modbus Description }} Converter of the RS-232 or RS-485 network , .5 CVM Power analyzers yy Connections: Ethernet, RS-232, RS-485 , Radio Protocols: Modbus TCP , }} TCP2RS: Converter RS232-RS485 / Ethernet ( Modbus /TCP): M54032 }} LM50-TCP: Alarm / Impulse Central , /4.20 mA ) * Digital inputs COMMUNICATIONS FEATURES RS-232 RS-485 * Ethernet , }} Optional energy consumption and generation billing (up to 9 rates) }} RS-485 Modbus /RTU Communications


Original
PDF M54040 RS-232 M54050 RS-232/485 RS-485 RS-232 M54032 M54020 M90231 M5-31 M54020 circutor m50730 M54410 M54020 M51B11 M51231 CVM-BD-RED-C420-H profibus vs. modbus M50790 LM50-TCP
4-20 mA converter modbus rs485

Abstract: Z-SG - Strain gauge converter analogue input MODBUS converter strain gauge strain gauge and load cells rs232 PM001600 rs485 modbus connection rs232-rs485 converter RS485 MODBUS baud rate converter
Text: gauge converter / RS485 Modbus INPUT: 6-wire bridge connections, lowest value 87 suitable for 1.4 loadcells (350 ) or 1.8 loadcells (1000 K ) OUTPUT: N.1 channel current 0.20, 4.20 mA or voltage 0.10 , SPECIFICATIONS Z-SG - Strain gauge converter / RS485 Modbus ORDER CODES Code Description Model Z-SG Software Strain gauge converter / RS485 Modbus Z-NET Configuration sw downloading from www.seneca.it , PORT RS485 - Modbus RTU RS232 Load cell (strain gauge) Z-SG Seneca


Original
PDF RS485 RS232 RS485 RS485- RS232 4-20 mA converter modbus rs485 Z-SG - Strain gauge converter analogue input MODBUS converter strain gauge strain gauge and load cells rs232 PM001600 rs485 modbus connection rs232-rs485 converter RS485 MODBUS baud rate converter
2002 - RJ12 to RS485

Abstract: No abstract text available
Text: ) RS-485 (OMEGA® Serial Protocol and MODBUS Serial Protocol) iDRN Output: 0 to 10 V @ 10 mA max; 0 , ߜ DRX Series Provide RS-485 Output (ASCII Serial Protocol and MODBUS Serial Protocol) ߜ Free , -wire (half duplex) RS-485 (OMEGA® Serial Protocol and Modbus Serial Protocol) iDRN Output: 0 to 10 V @ 10 , iDRX Series: 2-wire (half duplex) RS-485 /iDRN Series: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA , ASCII® Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485


Original
PDF RS-485 RS-485 DB9-RJ12 C-12B RJ12 to RS485
2013 - kd 2060 transistor

Abstract: saia factory 124
Text: ) Interface 1 x RS-485 with MODBUS slave (option) Galvanic isolation supply/input/output/ RS-485 , (option) 4 x relay or 8 x OC (option) 1 x analog (option) Interface Bargraph 1 x RS-485 MODBUS , ) RS-485 Modbus communication, Ethernet measured values logging 15 minute power logging , Separators supply/output/input - input/output RS485 Modbus Slave - - - - 85.253 V , , P12O Interface RS-485 Modbus Ethernet 10/100 Base-T (option) Galvanic isolation RS-485


Original
PDF rs-485 kd 2060 transistor saia factory 124
2002 - DIN111

Abstract: No abstract text available
Text: output RS-232/485 converter RS-485 repeater Each unit is supplied with a compete operator's manual , Basic Unit ߜ Complete Sensor to RS-485 Interface ߜ 500V RMS Analog Input Isolation ߜ 15 , Filter ߜ Requires +5VDC Supply ߜ Transient Suppression on RS-485 Communications Lines ߜ Screw , transmit via RS-485 to a master unit which may be a computer or other processor-based equipment. The , conditioning, scaling, linearization and conversion to either linearized ASCII data values or Modbus RTU


Original
PDF DIN-100 RS-485 15-Bit RS-485 /-60mV excitation/RS-485 /-120mV DIN111
2002 - Not Available

Abstract: No abstract text available
Text: duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol) iDRN Output: 0 to 10 V@10 mA max , $ Software Selectable Input Ranges iDRX-ACV: 0 to 400 mV to 0 to 400 Vac iDRX-ACC: 0 to 10 mA , mA through 0 to 5 A ac; AC Voltage ranges from 0 to 400 mV to 0 to 400 Vac. ANALOG or DIGITAL , respectively and transmit via RS-485 Serial Communications. ANALOG OUTPUT MODEL The Analog Output models can be configured for outputs of 0 to 10 Vdc, 4 to 20 mA or 0 to 20 mA with the free configuration


Original
PDF 14-Bit acce-20 RS-485 DB9-RJ12
DB9-RJ12

Abstract: RS485 to Ethernet Converter 4-20 mA converter modbus rs485 magnetic pickup Magnetic pickup proximity
Text: Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port , RS-485 (NEWPORT® Serial Protocol The Optional EIS-2B iServer module can and MODBUS Serial Protocol) connect up to thirty-two (32) iDRX iDRN Output: 0 to 10 V @ 10 mA RS-485 Signal Conditioners to an max , Closure and Open Collector Input Types RS-485 Output 1800 V Isolation Free Setup and Configuration , iDRX-FP uses digital RS-485 Serial Communication. ANALOG OUTPUT MODEL The output of iDRN-FP can be user


Original
PDF RS-485 RS-232 DB9-RJ12 RS485 to Ethernet Converter 4-20 mA converter modbus rs485 magnetic pickup Magnetic pickup proximity
PS-1050

Abstract: VISHAY VT 300 WEIGHT INDICATOR Digital Weighing Scale Circuit ph meter circuit apr 9600 rs 485 cable modbus Weighing scale indicator circuit 4-20 mA converter modbus rs485 Weighing scale circuit Digital Weighing Scale block
Text: in RS-232, RS-422, or RS485 format with Modbus RTU protocol. Up to 32 PS-1050's can be connected point-to-point using the RS-485 serial output. · Storage Tank, Bin, and Hopper Weighing · Silo and , Protocols ASCII, Modbus RTU Maximum Cable Length 50 feet RS-232, 3200 feet for RS-422 and RS-485 , Selectable 0-10 Vdc or 4-20 mA Isolated Analog Output · Peak Hold Functions for Dynamic/Historic , Filtering · Serial Communication and Modbus RTU Protocol DESCRIPTION PS-1050 Digital/Analog


Original
PDF PS-1050 10-Point PS-1050 08-Apr-05 VISHAY VT 300 WEIGHT INDICATOR Digital Weighing Scale Circuit ph meter circuit apr 9600 rs 485 cable modbus Weighing scale indicator circuit 4-20 mA converter modbus rs485 Weighing scale circuit Digital Weighing Scale block
Vishay nobel AST 3p

Abstract: ast 3p AST 3P, Transmitter Vishay nobel AST 3 4-20 mA converter modbus rs485 Vishay nobel AST-3P lcd 3901 Vishay nobel 3s
Text: AST 3P Vishay Nobel Transmitter FEATURES · Analog output ± 10 VDC, 0-20 or 4-20 mA · Serial communications: RS-485 , MODBUS RTU protocol · Internal resolution > 8000000 counts · Relay outputs · Compact , instruments in the Vishay Nobel programme and can communicate via standard RS-485 / MODBUS RTU protocol with a , COMMUNICATION INTERFACE Interface RS-485 (two-wires or four-wires), isolated 500V Protocol MODBUS RTU or , patented A/D converter , of high resolution and stability, serves as the heart of the transmitter. This


Original
PDF RS-485, 08-Apr-05 Vishay nobel AST 3p ast 3p AST 3P, Transmitter Vishay nobel AST 3 4-20 mA converter modbus rs485 Vishay nobel AST-3P lcd 3901 Vishay nobel 3s
2002 - Not Available

Abstract: No abstract text available
Text: Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port , scale iDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS Serial Protocol , , Contact Closure and Open Collector Input Types ߜ RS-485 Output ߜ 1800 V Isolation ߜ Free Setup and , signal. The iDRX-FP uses digital RS-485 Serial Communication. ANALOG OUTPUT MODEL The output of iDRN-FP can be user set for 0 to 10 V, 4 to 20 mA or 0 to 20 mA . Scaling and configuration is done with


Original
PDF RS-485 DB9-RJ12
2002 - Not Available

Abstract: No abstract text available
Text: open RS-485 with digital input, 0 or 5V RS-485 with modbus protocol RS-485 with modbus protocol with digital input switch closed RS-485 with modbus protocol with digital input switch open RS-485 with , , including RS-232 and RS-485 digital communications, three contact/digital input modes, four transducer , A @120 Vac, 3 A @ 240 Vac, N.O. (Output 2) Current: 0-20 mA ; 4-20 mA , 500 ohm max. (Suffix F1, F2); 0-20 mA ; 4-20 mA , 1000 ohm max. (Suffix FH1, FH2) Voltage: 20 Vdc pulse Solid State Relay


Original
PDF CN8240 CN8260 CN8201-R1 RS-232/485 CN8200 CN8592-DC1-DC2-24LV, CN8241 CN8242 CN8261 CN8262
Weighing scale circuit

Abstract: PS-1045 Digital Weighing Scale Circuit Digital Weighing Scale rs 485 cable modbus weighing scale calibration 4-20 mA converter modbus rs485 tactile push button switch datasheet V/PS-1040 proview
Text: -232, RS-422, or RS485 format with Modbus RTU protocol. Up to 32 transmitters can be connected point-to-point using the RS485 serial output. · Storage Tank, Bin, and Hopper Weighing Vishay Transducers , Standard Protocols ASCII, Modbus RTU Maximum Cable Length 50 feet RS-232, 3200 feet for RS-422 and RS-485 , Point Load Cell Linearization · Selectable 0-10 Vdc or 4-20 mA Isolated Analog Output · Peak Hold , Communication and Modbus RTU Protocol · Display (PS-1045) and Blind (PS-1040) Versions DESCRIPTION PS


Original
PDF PS-1040/45 PS-1045) PS-1040) PS-1040/45 08-Apr-05 Weighing scale circuit PS-1045 Digital Weighing Scale Circuit Digital Weighing Scale rs 485 cable modbus weighing scale calibration 4-20 mA converter modbus rs485 tactile push button switch datasheet V/PS-1040 proview
2002 - Not Available

Abstract: No abstract text available
Text: RS-485 communication link using either a simple, straightforward ASCII® Serial Protocol or MODBUS , °C (-328 to 1562°F) iDRX Output: 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS , output that is proportional to the input signal. The iDRX-RTD uses digital RS-485 communications. ANALOG OUTPUT MODEL The output of the iDRN-RTD can be user set for 0 to10 V, 4 to 20 mA or 0 to 20 mA , mA , 100°C = 20 mA NEWPORT manufactures many types of RTD probes. Refer to our website


Original
PDF RS-485 PT100, RS-485 DB9-RJ12
2002 - Not Available

Abstract: No abstract text available
Text: : 2-wire (half duplex) RS-485 (NEWPORT® Serial Protocol and MODBUS SERIAL Protocol) iDRN Output: 0 , output that is proportional to the input signal. The iDRX-TC uses a digital RS-485 communication link. ANALOG OUTPUT MODEL The output of iDRN-TC can be user set for 0 to10 V, 4 to 20 mA or 0 to 20 mA , DIGITAL OUTPUT MODEL The iDRX-TC is a digital signal conditioner which communicates over an RS-485 communication link using either a simple, straightforward ASCII® Serial Protocol or MODBUS Serial Protocol


Original
PDF RS-485 DB9-RJ12
Vishay nobel

Abstract: 4-20Ma TO PROFIBUS CONVERTER analogue input MODBUS converter nobel 420 converter modbus to profibus vishay nobel gate 3s 4-20 mA converter modbus rs485 nobel software vishay nobel gate 3s converter rs485 to profibus
Text: WST 3 Vishay Nobel Transducers Transmitter FEATURES · Analog output ± 10 VDC, ± 20 mA , 0-20 or 4-20 mA · Serial communication: RS-485 , MODBUS RTU protocol · Fieldbus interface: Profibus DP , Vishay Nobel instruments and communicate via standard RS-485 / MODBUS RTU protocol with a common process , COMMUNICATION INTERFACE Interface RS-485 (two-wires or four-wires), isolated 500V Protocol MODBUS RTU or , unique and patented A/D converter , of high resolution and stability, serves as the heart of the


Original
PDF RS-485, 08-Apr-05 Vishay nobel 4-20Ma TO PROFIBUS CONVERTER analogue input MODBUS converter nobel 420 converter modbus to profibus vishay nobel gate 3s 4-20 mA converter modbus rs485 nobel software vishay nobel gate 3s converter rs485 to profibus
PGC5000

Abstract: PGC5000 MODBUS CONNECTION 4-20 mA converter modbus rs485 PGC-5000 abb PGC5000 PGC5000A 5 zone alarm system PGC5000C PGC5000B PGC-5000c
Text: : Isolated 4-20 mA , 0-300 Ohms or 300-600 Ohms Measured and calculated component concentrations Max 16 , concentrations Max 16 AI modules dual (2) packages: Isolated 4-20 mA Read 3rd party AO values for , Ethernet connections: Redundant IS analyzer network communication Single channel MODBUS TCP/IP and serial RTU: Serial RTU includes a Selectable RS-232 or RS-485 DCS connection Includes single Ethernet connection for analyzer networking Redundant MODBUS TCP/IP and serial RTU: Serial RTU


Original
PDF PGC5000 PGC5000A PGC5000B PGC5000C 9AKK105123 PGC5000 MODBUS CONNECTION 4-20 mA converter modbus rs485 PGC-5000 abb PGC5000 5 zone alarm system PGC-5000c
2000 - Not Available

Abstract: No abstract text available
Text: Command RS-485 Modbus Binary (option) BAUD Rates 9600, 4800, 2400, 1200, 300 Parity 8 Bits No parity , operation and ticket printing. An optional ModBus interface provides cost effective connectivity to programmable logic controllers via the RS-485 serial port. Available in panel mount format, the AN3080 comes , just a few keystrokes. Parameters include: Weighing, System, Ticket, Digital Input, Setpoints, Modbus , -232 ports and one RS-485 port are standard on the Series for EDP communications and printer functions. The


Original
PDF AN3080 AN3080 R761/EN45501,
2012 - modbus pinout

Abstract: No abstract text available
Text: Serial Line Specification V1.0 (2002) 247 Modbus addresses. Up to 32 devices on an RS485 line with no , 4-20 mA & Serial Data Output Transmitter for DC Voltage or Current Signals LAUREL ELECTRONICS , ±300V and ±600V voltage input ranges ±2, ±20, ±200 mA and ±5A current input ranges All input ranges user selectable and factory calibrated 4-20 mA or 0-10V transmitter output, jumper selectable, isolated Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span RS232 or RS485


Original
PDF RS232 RS485 CBL04 RS-232 CBL02 3183-G modbus pinout
2014 - Not Available

Abstract: No abstract text available
Text: RS485 2 wire half duplex Baud rate: (selectable) 9,600 19,200 Protocol: Modbus RTU , , analogue output or Modbus Communications. The modules are easily installed, without the need for , Dual Relay Output Module Analogue Output Module ModBus Communication Module 262-300 262-30T , impedance: Accuracy: Thermal drift: Excitation output: 0-10 mA D.C. 0-20 mA D.C. 4-20 mA D.C. 47Ω 0.05% of full scale 100 ppm/°C 24V D.C. ±5% @ 50 mA max energy.te.com 2 TE Connectivity


Original
PDF 262-30T 62-30A 96x48mm E75911SP CI-EPP-2187-1/14
numeric ups 600

Abstract: resistance to Current Converter 0-20mA crompton* 262 RH -005c RELAY IEC 584-1 dual output transformer with input 24v analogue input MODBUS converter PT100 rtd 262-30T 262-RLY
Text: , analogue output or Modbus Communications. The modules are easily installed, without the need for , 262-ALG Temperature Indication A.C. Voltage and Current Control 262-30A ModBus , drift: Excitation output: 0-10 mA D.C. 0-20 mA D.C. 4-20 mA D.C. 47 0.05% of full scale 100 ppm/°C 24V D.C. ±5% @ 50 mA max 262-30A True RMS A.C. Voltage and Current Meter + + 0 - 10 , modules. The modules offer relay setpoints, analogue output or ModBus communications, which are easily


Original
PDF 262-30T 62-30A 96x48mm RS485 262-MOD numeric ups 600 resistance to Current Converter 0-20mA crompton* 262 RH -005c RELAY IEC 584-1 dual output transformer with input 24v analogue input MODBUS converter PT100 rtd 262-RLY
RS485 to Ethernet Converter

Abstract: entrelec link ABB rs-232 pin configuration schematic of RS 485 modbus R2300 entrelec type C switches 1SNA 115 413 R0100 R2700 R2000 R0200
Text: ( converter ) or amplify the signal (Repeater) using an ILPH. Type of connection RS232 RS422 RS485 CL , to Ethernet. TCP RS-232 RS-485 Example : Protocol conversion : Modbus is one of the , Modbus / RTU 1 N07001 060209 1SNC 116 001 C0202 · · RS232 RS422 / RS485 · · · , Range" ILPH RS 232 - 485 / Ethernet Isolated RS232 or/and RS485 to Ethernet converter Triple galvanic , from the standard RS232 or RS485 , to the Ethernet open products or the Optical Fiber. Ethernet


Original
PDF RS232 RS485, F-69685 C0202 RS485 to Ethernet Converter entrelec link ABB rs-232 pin configuration schematic of RS 485 modbus R2300 entrelec type C switches 1SNA 115 413 R0100 R2700 R2000 R0200
2008 - 900-TC16

Abstract: 900-TC8RGTZ25 900-TC16RGTU25 900-TC32 900-TC16VGTZ25 900-TC32RPZ25 schneider Pt100 sensor Platinum Resistance Temperature sensor 900-TC16ACGTZ25 PL II thermocouple
Text: Conversion Cable 900-CPOEM1 Interface Converter (RS-232/USB to RS-485 ) Model Converts personal , ) BCC or with ModBus CRC-16 Flow Control Not available 900-TC8 RS-485 /RS-232C 900 , 0 to 20 mA DC 4 to 20 mA DC Load: 600 max. RS-485 SD 9 19 10 20 Auxiliary , . Typically, an RS-232 to RS-485 converter such as the Cat. No. 900-CONVZ25 (see page 9-215) will be required , Converter Page 23 Bulletin 900 900BuilderLiteTM Software Page 26 Bulletin 900 900BuilderTM


Original
PDF 900-TC 900-TC 900-CONV 900BuilderLiteTM 900BuilderTM 900-TC8 900-TC16 900-TC32. 900-TC8RGTZ25 900-TC16RGTU25 900-TC32 900-TC16VGTZ25 900-TC32RPZ25 schneider Pt100 sensor Platinum Resistance Temperature sensor 900-TC16ACGTZ25 PL II thermocouple
2012 - hcf 4553

Abstract: 4-20Ma TO PROFIBUS CONVERTER transformer less power supply 110vdc output Z01207 wiring flowmeters converter diagram 110vdc to 24vdc 240 110 voltage converter converter rs485 modbus profibus 110VDC motor magnetic flow meter circuit diagram
Text: signal (4-20 mA ), it is fieldbus which digitizes all signals. Flowmeters support PROFIBUS-PA. * Modbus is , (opt.) Physical layer : RS485 Protocol : Modbus Mode : RTU Baudrate : 4800, 9600, 19200bps Data length , communication 3 Current output + Modbus ( RS485 ) communication 1 2 3 E Power supply(Note2) 100Vac-240Vac 50/60Hz , and in which low-level signals proportional to flow rates are obtained; and a converter , which , disturbances. Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type


Original
PDF 4-20mAdc ISO9001 ISO14001 hcf 4553 4-20Ma TO PROFIBUS CONVERTER transformer less power supply 110vdc output Z01207 wiring flowmeters converter diagram 110vdc to 24vdc 240 110 voltage converter converter rs485 modbus profibus 110VDC motor magnetic flow meter circuit diagram
VISHAY VT 300 WEIGHT INDICATOR

Abstract: vishay VT300 weight VISHAY VT 200 WEIGHT INDICATOR Digital Weighing Scale VISHAY VT 400 WEIGHT INDICATOR VT300 INDICATOR rs485 modbus connection Tedea-Huntleigh* rs232 modbus RS485 BLH load cell
Text: ; 4­20 mA - - 5 Basic IP20 RS485 ; MODBus ; 4­20 mA ; 0­10 V - - 5 Basic IP20 RS485 ; MODBus ; 4­20 mA ; 0­10 V; Profibus (option) - - 2 Products Features , level serial communication is available in RS-232, or RS-485 format with Modbus RTU or Profibus , serial communication is available in RS-232, or RS-485 format with Modbus RTU or Profibus protocol. Up , NTEP 10,000 Optional RS232 Option RS485 2 OIML 10,000 NTEP 10,000 - RS232 Option


Original
PDF SE-691 NO-0582 FI-02420 VTR-PL0021-0505 VISHAY VT 300 WEIGHT INDICATOR vishay VT300 weight VISHAY VT 200 WEIGHT INDICATOR Digital Weighing Scale VISHAY VT 400 WEIGHT INDICATOR VT300 INDICATOR rs485 modbus connection Tedea-Huntleigh* rs232 modbus RS485 BLH load cell
RCM2250

Abstract: modbus BL2600 sample CODE RS 485 communicate with BL2600 RCM3720 RCM3000 rs485 modbus connection bl2600 SBC MASTER AND SLAVE MODBUS SAMPLE CODE RCM3700 modbus protocol
Text: and serial gateway RS-485 BL2600 Modbus serial slave While you are running sample programs , Ethernet hub as shown in Figure 1. Finish by making a serial RS-485 connection of the Modbus slave to the , Modbus Protocol (Serial and TCP) for Rabbit-Based Systems 1. Introduction As defined by the Modbus Organization, Inc., " Modbus is an application-layer messaging protocol that provides client/server communication among boards connected on different types of buses or networks. Modbus is the de


Original
PDF BL2600 BL26xx RCM2250 modbus sample CODE RS 485 communicate with BL2600 RCM3720 RCM3000 rs485 modbus connection bl2600 SBC MASTER AND SLAVE MODBUS SAMPLE CODE RCM3700 modbus protocol