The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
RH1034MW-1.2 Linear Technology Micropower Dual Reference
LTC1258CMS8 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 2.385 V, PDSO8, PLASTIC, MSOP-8, Voltage Reference
LT1019CN-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDIP, Voltage Reference
LT1019IS-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDSO, Voltage Reference
LT1021BIN-5 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 5 V, PDIP, Voltage Reference
LT1021CIN-10 Linear Technology IC 1-OUTPUT THREE TERM VOLTAGE REFERENCE, 10 V, PDIP, Voltage Reference

24v PED relay cross reference Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2N33

Abstract: No abstract text available
Text: /0.5V · Internal Bandgap Voltage and Current Reference Applications · Fuel Pump Driver · Relay , lo =600mA (-40°C to +25°C Ambient) . 24V Max. Positive Output Peak Pulse , Test Pin Reference SYM BO L Vcc V SAT TEST CONDITIONS VCc Reference to Vsw l0 = -400mA, Vsw = OV, Vcc = 16V Vsw = 0V (Switch ON) T a = +85°C, Vcc = 16V T a = +25°C,Vcc = 24V MIN 4 - TYP - MAX , 24V ,Vsw = 0V, l0 - RL = 40n, VSW=1V Vcc < O o = II 24V < -50 -50 - mA mA Min


OCR Scan
PDF CA3273 CA3273 2N33
I1N4001

Abstract: mosfet power hf 1kw HF 2N 24V 30A PED relay 24V EM- 546 motor ic5012 IC5010 24v PED relay cross reference irf540 mosfet control motor 1000-4T
Text: low-side switches Applications · · · · · · Lamp drivers Relay and solenoid drivers Heater switching , DIP Die MIC5010AJ V = 24V MIC5010AJB* MIC5010B Control Input o- ' AJB indicates units , . Reference for the current sense voltage on pin 5 and return for the gate clamp zener. Connect to the load , devices should not cross conduct (shoot-through) when switching. Cross conduction increases output device , at each input provide a 2 to 3^s dead tim e effectively elim inating 24V Applications Inform


OCR Scan
PDF MIC5010 MIC501X IC5010 I1N4001 mosfet power hf 1kw HF 2N 24V 30A PED relay 24V EM- 546 motor ic5012 24v PED relay cross reference irf540 mosfet control motor 1000-4T
1412D

Abstract: UDN2983A equivalent M54522P equivalent 1411d DARLINGTON SINK DRIVER TLP251 equivalent M54563P equivalent ULN2804A application relay driver ic ULN2804 td62304ap
Text: RESISTOR) OPERATE DIRECTLY WITH 6V-15V CMOS Cross Reference of Standard Transistor Array Cross , - UDN2981A UDN2982 UDN2982LW - - - 80/0.5 - Cross Reference of Standard Transistor Array (Part 1) Cross Reference of Standard Transistor Array (Part 1) Device ULN2001A ULS2001H , Cross Reference of Standard Transistor Array (Part 2) Cross Reference of Standard Transistor Array , /0.5 50/0.5 50/-0.5 35/0.35 60/-0.05 Cross Reference of Standard Transistor Array (vs


Original
PDF ULN2000 TD62xxx TD62Mxxx TB62xxx RS232C RS422 25degC) TD62445FN SSOP18-P-225-0 1412D UDN2983A equivalent M54522P equivalent 1411d DARLINGTON SINK DRIVER TLP251 equivalent M54563P equivalent ULN2804A application relay driver ic ULN2804 td62304ap
Not Available

Abstract: No abstract text available
Text: detection and LED indicator drive Relay drive output Battery and ringing feed to line Logic Interface , Input. Normally connected to Ring Relay . 5 IC Internal Connection. Leave open circuit. Use for , /transm it audio speech path, (referenced to 0V GND). 17 RD Relay D river Output. Open collector sinks current when RC high. Diode clamp 18 RGND Ground fo r Relay Drive Circuit. 19 RC Ring Control Input. Active high. 20 CD Clam ping Diode. Normally connected to relay positive


OCR Scan
PDF MH88500 ianuary1994 MH88500 20-Pin H88500 12Max b54T370
IMO SR2C

Abstract: emergency stop relay EMERGENCY OFF PUSH BUTTON VDE0113 emergency stop relay a1 EN954-1 T11-T12 VDE0113-1 EN60204-1 control relay A1 A2
Text: T14 T12 13 23 14 T21 24 only 24V Relay control and error monitoring incl. aux relay K1 K1 K2 only 24V Two channel safety guard monitoring with cross short circuit and ground , Emergency Stop Relay (type 4) SR2C continued Wiring connections Two channel emergency stop with cross , Relay control and error monitoring incl. aux relay K1 K1 K2 + only 24V T10 A2 One , Relay control and error monitoring incl. aux relay K1 K1 K2 only 24V A2 SR2C/03/03 T10


Original
PDF 24VDC 230VAC EN60204-1 EN60204-1, VDE0113-1, EN954-1 SR2C/03/03 IMO SR2C emergency stop relay EMERGENCY OFF PUSH BUTTON VDE0113 emergency stop relay a1 EN954-1 T11-T12 VDE0113-1 EN60204-1 control relay A1 A2
IMO SR2C

Abstract: 24vrelay EN60204 emergency stop relay a1 emergency stop relay EN954-1 EMERGENCY OFF PUSH BUTTON T11-T12 imo relay 1500VA
Text: Relay control and error monitoring incl. aux relay K1 K1 K2 only 24V A2 One channel emergency , 23 14 24 Emergency stop On A1 T11 T21 T12 T14 only 24V Relay control and error monitoring incl. aux relay K1 K1 K2 only 24V T10 A2 Two channel safety guard , only 24V Relay control and error monitoring incl. aux relay K1 K1 K2 only 24V A2 99 , Extremely compact universal emergency stop relay . Designed to be used in safety-circuits in


Original
PDF EN60204-1 24VDC 230VAC EN60204-1, VDE113-1, EN954-1 IMO SR2C 24vrelay EN60204 emergency stop relay a1 emergency stop relay EN954-1 EMERGENCY OFF PUSH BUTTON T11-T12 imo relay 1500VA
DC-13

Abstract: S11-S12 S1232
Text: applications Two-channel activation including Cross Monitoring Automatic or Manual Star Activation via , for generating a safetyorientied output signal (enable) via forced output relay contacts. 2 , to 2.5mm2 flexible with multicore cable ends 4. Input circuit Supply voltage: 24V AC/DC Tolerance: 24V AC/DC Rated frequency: Rated consumption: 24V AC/DC Duration of operation: Residual , /230V AC) max. 6/min (DC-13: 4A/ 24V DC) max. 60/min (DC-13: 2.5A/ 24V DC) Insulation voltage


Original
PDF S2NGS021 S11/S12) S21-S22) S33-S34) S11/S33 DC-13 S11-S12 S1232
S11-S12

Abstract: DC-13 S21-S22 S11S12
Text: tA1 tR 24V ~ 0V Reset A1 Two-channel E-stop without Cross Monitoring with manual , tR1. A reset of the safety relay can only be executed, if the short circuit has been removed. 24V , applications Equivalent or non-equivalent activation selectable Two-channel activation including Cross , safety actuators for generating a safetyorientied output signal (enable) via forced output relay contacts , Supply voltage: 24V AC/DC Tolerance: 24V AC/DC Rated frequency: Rated consumption: 24V AC/DC


Original
PDF S2LST030 S33-S35) S11-S12 DC-13 S21-S22 S11S12
S33-S34

Abstract: S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12
Text: Safety Gate applications Two-channel activation with Cross Monitoring and Synchronous Time Check , (enable) via forced output relay contacts. 2 non-delayed and 1 off-delayed enabling current path for , . Input circuit Supply voltage: 24V DC Tolerance: 24V DC Rated frequency: Rated consumption: 24V DC Duration of operation: Residual ripple bei DC: 5. Output circuit terminals A1-A2 -15% , (AC-15: 3A/230V AC) max. 6/min (DC-13: 4A/ 24V DC) max. 60/min (DC-13: 2.5A/ 24V DC) Insulation


Original
PDF S2NGR120 S11/S12) S21-S22) S33-S35) S33-S34 S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12
relay 24v

Abstract: normally closed normally open operation of relay S33-S34 S11-S12 230v dc 5a diode bridge S33-S35 emergency stop relay debouncing relay contact DATASHEET OF RELAY -5V, 230V INPUT 6A mcb
Text: Safety Gate applications Two-channel activation with Cross Monitoring and Synchronous Time Check , signal (enable) via forced output relay contacts. 2 non-delayed and 1 off-delayed enabling current path , multicore cable ends 4. Input circuit Supply voltage: 24V DC Tolerance: 24V DC Rated frequency: Rated consumption: 24V DC Duration of operation: Residual ripple bei DC: terminals A1-A2 -15% to , ): max. 6/min (AC-15: 4A/230V AC) max. 60/min (AC-15: 3A/230V AC) max. 6/min (DC-13: 4A/ 24V DC) max


Original
PDF S2NGR120 S11/S12) S21-S22) S33-S35) relay 24v normally closed normally open operation of relay S33-S34 S11-S12 230v dc 5a diode bridge S33-S35 emergency stop relay debouncing relay contact DATASHEET OF RELAY -5V, 230V INPUT 6A mcb
1RFP250

Abstract: ic HP 1003 WA
Text: drivers Relay and solenoid drivers Heater switching Power bus switching Motion control Half or full , . 6 Source Reference for the current sense voltage on pin 5 and return for the gate clamp zener , half-bridge driver. This topology presents an extra challenge since the two output devices should not cross conduct (shoot-through) when switching. Cross conduction increases output device power dissipa­ tion , provide a 2 to 3ns dead tim e effectively elim inating 24V 24V CR 2943-N A102A (GE) OFF


OCR Scan
PDF IL-STD-883 MIC5010 IC501X switch12 IC5010 1RFP250 ic HP 1003 WA
2010 - Relay schrack RU

Abstract: omron relay G2R-2 8 pin 12V DC relay finder 12V DC Panasonic RELAY Cross Reference AROMAT hjq-22f 700-HN122 RELAY PCB DPDT 12V 8 pin 700-HC24 700-HN154 RELAY PCB DPDT 12V
Text: sockets 7 Relay & Socket Cross Reference Guide Allen-Bradley IDEC Cutler-Hammer IDEC , ( reference values) Coil Voltage DC 6V AC 6V AC 12V DC 12V AC 24V DC 24V AC 120V DC 48V AC 240V DC , Relay Selection Guide Call (800) 262.IDEC www.IDEC.com/ relay RH Series - Compact Power Relays · Small industrial 10A GP relay · SPDT, DPDT, 3PDT, 4PDT contacts · Options: indicator LED , cadmium oxide (AgCdO) Contact Rating 10A Minimum Load ( reference values) Dimensions (w x d x h


Original
PDF AC12V AC24V AC120V AC240V DC12V DC24V DC48V DC110V AC110s 800-262-IDEC Relay schrack RU omron relay G2R-2 8 pin 12V DC relay finder 12V DC Panasonic RELAY Cross Reference AROMAT hjq-22f 700-HN122 RELAY PCB DPDT 12V 8 pin 700-HC24 700-HN154 RELAY PCB DPDT 12V
ossd output

Abstract: 24v 8 channel Relay driving 24V ac relays DSAE00636 S2NG021 S1232 S11-S12 S34-S35 s34 diode 24v relays
Text: safety relay can only be provided, if the e-stop switch has been unlocked again. 24V ~ 0V Reset , relay can only be executed, if the short circuit has been removed. 24V ~ 0V 13 23 24 31 , . A restart of the safety relay is disabled until both safety channels have been deenergized. 24V , Two-channel activation including Cross Monitoring and Synchronous Time Check Automatic or Manual Star , output relay contacts. Function: 2. Indicators Subject to alterations and errors Green LED U


Original
PDF S2NG021 S12-S35) S11/S33 ossd output 24v 8 channel Relay driving 24V ac relays DSAE00636 S2NG021 S1232 S11-S12 S34-S35 s34 diode 24v relays
S2NG021

Abstract: DC-13 S11-S12 3132is S1232
Text: relay can only be executed, if the short circuit has been removed. 24V ~ 0V 13 23 24 31 , Two-channel activation including Cross Monitoring and Synchronous Time Check Automatic or Manual Star , safety actuators for generating a safetyorientied output signal (enable) via forced output relay contacts , S11-S12 Safety channel 2 (CH2) cross monitoring: terminals S21-S22 (bridge S33-S31) without cross monitoring: terminals S33-S31 (bridge S21-S22) Synchronous time (CH1 before CH2): approx


Original
PDF S2NG021 S12-S35) S11/S33 S2NG021 DC-13 S11-S12 3132is S1232
1995 - 1492-IFM40

Abstract: 1492-IFM40F Allen-Bradley 1746-OW16 1492-IFM40F-2 1746-IB16 1746-OW16 1492-IFM40F-F24-2 1492-IFM20F-F24-2 1492-IFM40D24A-2 1492IFM40F2
Text: ModuleReady Cables IFM Specifications IFM Labels Reference Publications Page 2 2 3 3 4 4 5 5 6 , compact method of terminating and powering 24V AC/DC 3­wire devices. Fusible Modules Fusible , fuse indication. The 24V AC/DC or 120V AC blown fuse indicators reduce the troubleshooting time to , 24V AC/DC LEDs 24V AC/DC LEDs for Input Modules 120V AC LEDs 120V AC LEDs for Input Modules Fuse , Clips with 24V AC/DC Blown Fuse Indicators F120 5 x 20mm Fuse Clips with 120V AC Blown Fuse


Original
PDF Specifications10 1492-IFM40 1492-IFM40F Allen-Bradley 1746-OW16 1492-IFM40F-2 1746-IB16 1746-OW16 1492-IFM40F-F24-2 1492-IFM20F-F24-2 1492-IFM40D24A-2 1492IFM40F2
schematic diagram 230VAC to 24VDC POWER SUPPLY

Abstract: lg5925 schematic diagram emergency light emergency stop relay LG monitor circuit diagram dold bn 5983 LG5929 7824 7924 7824 lg monitor
Text: . Emergency Stop Relay Type LG 5925 safemaster LG 5925.48 with LG 5929.60 Extension modules + 24V ON , Relay Type LG 5925.48 Auxiliary Supply 24V ac/dc 3 23 13 23 K1 Information Required With , Emergency Stop Relay Type LG 5925 safemaster Features · Category 3 or 4 switch programmable , Electrical Engineering Typical Schematic Diagram LG 5925.48 Description Emergency Stop Relay LG , the front plate to enable the selection of : + 24V ON RESET A1 (+) S33 S34 13 23 33 LOGIC


Original
PDF 24VAC/DC 230VAC req33 schematic diagram 230VAC to 24VDC POWER SUPPLY lg5925 schematic diagram emergency light emergency stop relay LG monitor circuit diagram dold bn 5983 LG5929 7824 7924 7824 lg monitor
Relay 2 RT 5v matsushita

Abstract: Relay Matsushita Relay 2 RT 5v matsua Matsushita relay RT3S-24V Matsushita Electric Works relay Relay 2 RT matsushita RT3S-12V matsua relay cross reference Relay 12V 15 mA
Text: ratings (per PA relay ) Part No. RT3S-12V RT3S- 24V Input current (at rated input voltage, 20°C 68 , RT-3 (PA Relay type) SLIM, SPACE-SAVING RELAY TERMINAL FOR 4-POINT OUTPUT RT-3 UNIT RELAY (PA Relay type) FEATURES 1. Space-saving type (33 mm 1.299 inch wide) with four independent , . Relay installation and removal can be easily accomplished with the removal key accessory. 7. Includes , voltage 12 V DC 24 V DC 1 Form A × 4 Part No. RT3S-12V RT3S- 24V Packing quantity: Carton: 1


Original
PDF
RT3SP1-24V

Abstract: Relay 2 RT matsushita photomos relay 12V 40A Relay Relay Matsushita Matsushita relay relay 24v 30a relay dc 24V matsua 12V 200A Relay Relay 2 RT matsua
Text: easy confirmation of operation. 5. Incorporates a cross connection preventing diode. 6. Relay , . Output ratings (per relay , at 25°C 77°F) Part No. RT3SP1-12V RT3SP1- 24V RT3SP2-12V RT3SP2- 24V , -12V, RT3SP1- 24V , RT3SP2-12V AND RT3SP2- 24V CAN BE EQUIPPED WITH THE RELAYS BELOW (per relay , at 25°C 77°F, initial) Possible relays RT-3 unit relay Type RT3SP1-12V RT3SP1- 24V Power PhotoMOS Relay (DC only) RT3SP2-12V RT3SP2- 24V Power PhotoMOS Relay (AC/DC dual use) Output Part No. AQZ102


Original
PDF AQZ102) RT3SP1-24V Relay 2 RT matsushita photomos relay 12V 40A Relay Relay Matsushita Matsushita relay relay 24v 30a relay dc 24V matsua 12V 200A Relay Relay 2 RT matsua
2013 - OMRON G2V-2 12V relay

Abstract: spdt 6v 1a relay 5V SPDT relay OMRON G2V-2 6V relay relay 12V, 70A GS-SH-205T MATSUA compressor codes dry contact relay 220V 12V 40A Relay 12V 30A SPDT RELAY
Text: 8A 5mm, 2CO, 230V AC 24V DC From From £1.49 Page 683 See page 676 Low Profile Relay DPCO 1A Ultra-slim Relay SPDT 6A 12V DC, 1028Ω 24V DC From £2.08 £0.88 See page , 5V 12V 24V Operating temperature A reed relay range that is suitable for applications where , Reed relay 24V Reed relay Dropout voltage VDC 0.8 1 2 Coil resistance Ω 140 ±10% 500 , 671 Photomos Relays Surface Mount 24V DC SPCO subminiature automotive relay - SRMA Dual


Original
PDF 100mA OMRON G2V-2 12V relay spdt 6v 1a relay 5V SPDT relay OMRON G2V-2 6V relay relay 12V, 70A GS-SH-205T MATSUA compressor codes dry contact relay 220V 12V 40A Relay 12V 30A SPDT RELAY
Not Available

Abstract: No abstract text available
Text: 24V SLIC For PABX/Key Systems • W ide O pe ra ting B attery R ange (-21V to -44V) T he H , ) . (V c c - V B A | ) . Relay Drive , . Relay Driver Voltage (V r q ) . Positive Supply Voltage ( V , . 2.4V . 0.6V Transistor C o u n t , evaluation PC board in free air. Electrical Specifications Unless Otherwise Specified, V b a t = - 24V


OCR Scan
PDF HC5503 10ki2,
PILZ pze x4p

Abstract: pilz pze 7 PILZ pze 9 Pilz safety relay PZE 9 PILZ x4p PZEx4P PZE-X4P-C Pze x4p Pilz pze 5 pnoz 1
Text: Positive-guided relay outputs: ­ 4 safety contacts (N/O), instantaneous LED indicator for: ­ Switch status , reference for unit types Gertemerkmale Gertebild Unit description Contact expansion module for , circuit Base unit: PNOZ X safety relay Single-channel Dual-channel 24 V DC A1 PZE A2 0V Base unit: PNOZelog safety relay Driven via semiconductor outputs (24 VDC) O1 A1 0V A2 PZE L- Feedback loop Feedback loop Base unit: PNOZ X safety relay Base unit: PNOZelog


Original
PDF NSG-D-2-165-2010-08 PILZ pze x4p pilz pze 7 PILZ pze 9 Pilz safety relay PZE 9 PILZ x4p PZEx4P PZE-X4P-C Pze x4p Pilz pze 5 pnoz 1
L9350

Abstract: No abstract text available
Text: SUPPLY L9350 operates over the full battery voltage range, from 4.5V (cold cranking) up to 24V (jum p , < V, < 5.5V V 0 = 0V Vs = 24V V, < 0.8V l0 = 125mA Vs = 4.5V l0 = 225m A Vs = 14.4V l0 = 550m A Vs = , utput Zener Voltage Turn ON Delay Turn O FF Delay Turn On D elay W hile O utput is C lam ped R l = , OPEN 0. luF RELAY . VALVE COIL, SOLENOID V+ (5 -2 4 V ) 0 . lu F Hh T u in _ PWM MODULATED


OCR Scan
PDF L9350 100/A L9350
S2 Switch Normally close

Abstract: 6A mcb S13-S14
Text: Equivalent or non-equivalent activation selectable Two-channel activation including cross monitoring and , safety switching device with self-monitoring on each ONOFF cycle and forced output relay contacts , . Input circuit Supply voltage: 24V AC/DC Tolerance: 24V AC/DC Rated frequency: Rated consumption: 24V AC/DC Duration of operation: Residual ripple bei DC: 5. Output circuit terminals , /230V AC) max. 6/min (DC-13: 4A/ 24V DC) max. 60/min (DC-13: 2.5A/ 24V DC) Insulation voltage


Original
PDF S2NT030 S13/S14) S23/S24) S14/S35) S2 Switch Normally close 6A mcb S13-S14
wiring diagram for ge cr2943

Abstract: wiring diagram for ge cr2943na102a ic501 MIC5011AJ IRF540 mosfet MOSFET IRFp250 I
Text: IC5013 protected 8-pin driver. Applications · · · · Lamp drivers Relay and solenoid drivers Heater , 10OuF storage capacitor. A zener 24V CR2943-NA102A (GE) Industrial Switch 5-95 MIC5011 , Squarewave Figure 7. High-Voltage Bootstrapped Driver Cross conduction increases output device power , . Delay networks at each input provide a 2 to 3ns dead time effectively eliminating cross conduction. Two , two output devices should not cross conduct (shoot-through) when switching. Figure 8. Half-Bridge


OCR Scan
PDF MIC5011 MIL-STD-883 MIC501X MIC5011 IC5011 wiring diagram for ge cr2943 wiring diagram for ge cr2943na102a ic501 MIC5011AJ IRF540 mosfet MOSFET IRFp250 I
12V 150 ohms relay

Abstract: V23104-A1001-B101 AXICOM Relay V23104-A1003-B101 siemens relay dc 12v MT4C93801 C93823E tyco 24v relay AXICOM mt4 Relay 2-1462032-7
Text: numbers cross reference is as follows: Coil 5V 12V 24V MT4 Part No Old Siemens V23104 No , TYCO MT4 Relay Replacements MT4 / V23104 replacement Following the obsolescence of the MT4 Axicom relay at the end of 2005 it has now been decided due to market requirements to develop an alternative product. The MT4 relay (formerly also known as the Siemens V23104 series) was a unique product with no drop in replacement available from Tyco or other relay companies. The replacement solution is a PCB


Original
PDF V23104 MT4-C93801 RS422-6947) 14620al) 23deg 12V 150 ohms relay V23104-A1001-B101 AXICOM Relay V23104-A1003-B101 siemens relay dc 12v MT4C93801 C93823E tyco 24v relay AXICOM mt4 Relay 2-1462032-7
Supplyframe Tracking Pixel