The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LT1111CJ8-12 Linear Technology SWITCHING REG +12V OUT
LTC1263IS8#TR Linear Technology IC CONV DC/DC FLASHMEM 12V 8SOIC
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C

12v center tap transformer Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
230v input to 12v output as step down transformer

Abstract:
Text: the transformer current can be approximated as: For a Full-Wave Center Tap 1.2 x 0.35 = 0.42 A or , a Full-Wave center tap application Secondary rating: 28 VCT @ 0.42 A Approx. transformer power , be seen that the transformer secondary voltage can be specified as 28VCT ( center tap ). For a bridge , . Transformer Secondary Current VREG REG C + VOUT DC Full-Wave center tap 1. VREG is , , 2nd Edition, 1989, McGraw Hill Technical Notes Therefore a center tap configuration is usually


Original
PDF
1999 - b-3067

Abstract:
Text: -61590 Universal ACE and the BUS-65149RT hybrid, the transformer center tap , pin 2, MUST NOT be grounded. The , (with the opposite signal polarity). If the transformer center tap is grounded, there is a strong , output stage, through one leg of the isolation transformer to the transformer center tap . It is important to realize that the high current path is through the transformer center tap and not through the , polarity signals. For the BU-61590 or BUS-65149, the transformer center tap must not be grounded. In


Original
PDF AN/B-27 MIL-STD-1553B 1-800-DDC-5757 A5976 b-3067 BUS-25679 BU-65620 ddc b-3067 HLP-6002 BU-61590 datasheet center tapped transformer BTTC B-3067 B-3067 TRANSFORMER 12v center tap transformer
EMCO F40

Abstract:
Text: 0 to +/-800V 12.5 mA <0.1% 0 to +/-1,000V 10 mA <0.1% OPTIONS Output Center Tap , . .20 (5.08) .45 (11.43) 3 1 .80 (20.32) 5 2 (+) Output 4 (-) Output Center tap , SILICONE 6.00" (152.40mm) MIN 1 (-) Input 3* (+) Output 4* (-) Output 5 Center tap , . These modules exhibit very low FEATURES Metal Case and Shielded Transformer result in: EMI/RFI, noise , required MTBF:>810k hours per Bellcore TR-332 quasi-sinewave oscillator, a fully enclosed transformer


Original
PDF Input/Output43) EMCO F40 12v center tap transformer 12v output center tap transformer 12v 500ma center tap transformer 4722a f10r F60 emco input and output center tap transformer Outgass E-959-93
Not Available

Abstract:
Text: . Return for Input AC/DC voltage. The transformer center tap must be connected to this pin. This pin is , MODULE ■■. ■■■■unit can be supplied either with a center tapped transformer secondary winding or a DC voltage. MTBF IN EXCESS OF 200.000 HOURS 2A OUTPUT CURRENT @ 5V ± 12V /0.125A , 11,25V derived by a transformer center tapped secondary. MODULE PROTECTIONS The module is , NOISE Two unregulated outputs (± 12V @ 125mA) useful for LED lamps or relay supply are also


OCR Scan
PDF GS-M51212 125mA) GS-M51212 12Vunr
12-0-12 center tap transformer

Abstract:
Text: through 240VAC -510 through -620: Center Tap Sec Output Voltage 10VAC through 120VAC or 2) GT-SUC , ) QUICK TERM. DUAL PRI DUAL SEC PCB MOUNT CENTER TAP MODEL NUMBER OUTPUT (VAC , N.A. SINGLE SEC QUICK TERM. CENTER TAP PCB MOUNT PCB MOUNT MODEL NUMBER OUTPUT , QUICK TERM. SINGLE PRI N.A. SINGLE PRI EURO. CENTER TAP PCB MOUNT MODEL NUMBER OUTPUT , · · · · · · · · · · QUICK TERM. CENTER TAP SINGLE SEC PCB MOUNT PCB MOUNT (LOW


Original
PDF 180VA, 120VAC/60Hz 230VAC/50Hz 120/240VAC, 50-60Hz 115VAC, 115/230VAC, 12-0-12 center tap transformer step down transformer 12-0-12 transformer EI lamination 12012 step down transformer 12-0-12 transformer step down 12012 transformer 12-0-12 center tap transformer 240v 12.6v step down transformer transformer 240V to 12V 1.25A 12-0-12 center tap step down transformer
1997 - 470uF capacitor

Abstract:
Text: +5V_A NC GND_A RXIN_A_L RXIN_A + 12V _A TXB_L TXB TXINH_B +5V_B NC GND_B RXIN_B_L RXIN_B + 12V _B TXOUT_L RXIN RXIN_L TXOUT_L RXIN RXIN_L Transformer Requirements: The NHI-15115 requires a transformer with a turns ratio of 1.25:1.00 for Direct Coupling, and a turns ratio of 1.66:1.00 for Transformer Coupling to the Mil-Std-1553 Bus. Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the isolation transformer must be grounded. TRANSFORMER COUPLED NHI


Original
PDF NHI-15115 NHI-15115 Mil-Std-1553 Q1553-3 470uF 470uF capacitor 12v center tap transformer 12v output center tap transformer technitrol 11
2013 - 4321F

Abstract:
Text: IN12: Data Pair Input 1. In a PoE system, IN12 connects to the center tap of the transformer connected , Input 2. In a PoE system, IN36 connects to the center tap of the transformer connected to pins 3 and 6 , system, IN45 connects to the center tap of the transformer connected to pins 4 and 5 on an RJ45 , to the center tap of the transformer connected to pins 7 and 8 on an RJ45 connector. EN: Enable , . –0.3V to OUTP + 12V TG12-IN12 to 12V


Original
PDF LT4321 RJ-45 LT4321 LTC4355 LTC4359 LTC4290/LTC4271 4321f com/LT4321 4321F LT432 TG12
1998 - 12v center tap transformer

Abstract:
Text: recommended. The center tap on the transceiver side of the isolation transformer must be grounded , TX TX Transmit TX_L TXINH Logic + 12V Data Bus Isolation Transformer TXOUT Coupler Box Direct , RXIN_B_L RXIN_B + 12V _B TXOUT_L RXIN RXIN_L TXOUT_L RXIN RXIN_L Transformer Requirements: The NHI , Mil-Std-1553 Products NHI-1503 Series + 12V Dual Transceivers Features/Applications: Very Low Standby , Screened to Mil-PRF-38534 Description: The NHI + 12V dual transceivers are available in 1.900" x .780"


Original
PDF Mil-Std-1553 NHI-1503 Mil-PRF-38534 Mil-Std-883 QML-38534 12v center tap transformer center tap transformer 18 0 18
1998 - Not Available

Abstract:
Text: Mil-Std-1553 Bus. Technitrol part number Q1553-2 or equivalent is recommended. The center tap on the , Mil-Std-1553 Products NHI-1503 Series + 12V Dual Transceivers Features/Applications: Description: Very Low Standby Power The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin , manchester to the coupling transformer when the TX and TX_L inputs are driven by complementary TTL digital , Mil-PRF-38534 +5V + 12V Data Bus TRANSMITTER TX TX TX_L Coupler Box TXOUT Shaping


Original
PDF Mil-Std-1553 NHI-1503 Mil-Std-883 QML-38534 Mil-PRF-38534
1998 - Not Available

Abstract:
Text: recommended. The center tap on the transceiver side of the isolation transformer must be grounded , TX TX Transmit TX_L TXINH Logic + 12V Data Bus Isolation Transformer TXOUT Coupler Box Direct , RXIN_B_L RXIN_B + 12V _B TXOUT_L RXIN RXIN_L TXOUT_L RXIN RXIN_L Transformer Requirements: The NHI , Mil-Std-1553 Products NHI-1502 Series + 12V Dual Transceivers Features/Applications: Very Low Standby , Screened to Mil-PRF-38534 Description: The NHI + 12V dual transceivers are available in 1.900" x .780"


Original
PDF Mil-Std-1553 NHI-1502 Mil-PRF-38534 Mil-Std-883 QML-38534
1998 - Not Available

Abstract:
Text: Mil-Std-1553 Bus. Technitrol part number Q1553-2 or equivalent is recommended. The center tap on the , Mil-Std-1553 Products NHI-1502 Series + 12V Dual Transceivers Features/Applications: Description: Very Low Standby Power The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin , manchester to the coupling transformer when the TX and TX_L inputs are driven by complementary TTL digital , Mil-PRF-38534 +5V + 12V Data Bus TRANSMITTER TX TX TX_L Coupler Box TXOUT Shaping


Original
PDF Mil-Std-1553 NHI-1502 Mil-Std-883 NHI-1502 QML-38534 Mil-PRF-38534
1997 - Not Available

Abstract:
Text: corresponding Technitrol part numbers Q1553-X are outlined in the table below. The center tap on the transceiver , Mil-Std-1553 Products Single Channel Hybrid Transceivers Features/Applications: Available for +15V, + 12V , transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides a , Logic +V Data Bus Isolation Transformer TXOUT Coupler Box Direct Or Transformer Shaping , Figure I: Block Diagram Single Channel Transceivers Transformer Requirements: The NHI-15XX series


Original
PDF Mil-Std-1553 Mil-PRF-38534 avai175 NHI-1508 Mil-Std-883 QML-38534
1997 - Not Available

Abstract:
Text: corresponding Technitrol part numbers Q1553-X are outlined in the table below. The center tap on the transceiver , Mil-Std-1553 Products Single Channel Hybrid Transceivers Features/Applications: Available for +15V, + 12V , transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides a , Logic +V Data Bus Isolation Transformer TXOUT Coupler Box Direct Or Transformer Shaping , Figure I: Block Diagram Single Channel Transceivers Transformer Requirements: The NHI-15XX series


Original
PDF Mil-Std-1553 Mil-PRF-38534 NHI-1508 Mil-Std-883 QML-38534
1997 - Not Available

Abstract:
Text: with industry standard decoders. + 12V Data Bus Isolation Transformer Coupler Box Direct Or , . Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the , Mil-Std-1553 Products NHI-1522 Series + 12V Dual Transceivers Features/Applications: Very Low Standby , The transmitters will output bi-phase manchester to the coupling transformer when the TX and TX_L , : The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin plug-in and flatpack packages


Original
PDF Mil-Std-1553 NHI-1522 Mil-Std-883 QML-38534 Mil-PRF-38534
Not Available

Abstract:
Text: in the table below. The center tap on the transceiver side of the isolation transformer must be , : Available for +15V, + 12V , and +5V Only Applications Very Low Standby Power Low Thermal Resistance Very Low , manchester to the coupling transformer when the TX and TX_L inputs are driven by complementary TTL digital , TRANSMITTER TX TX Transmit TX L TXINH Logic +v _JL Isolation Transformer TXOUT Data Bus W SA , Coupler Box Direct Or Transformer Shaping Network TXO UTL RECEIVER RX RX Receive RX L Logic


OCR Scan
PDF Mil-Std-1553 Mil-PRF-38534 NHI-1508 Mil-Std-883 QML-38534
1997 - NHI-1523

Abstract:
Text: with industry standard decoders. + 12V Data Bus Isolation Transformer Coupler Box Direct Or , . Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the , Mil-Std-1553 Products NHI-1523 Series + 12V Dual Transceivers Features/Applications: Very Low Standby , The transmitters will output bi-phase manchester to the coupling transformer when the TX and TX_L , : The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin plug-in and flatpack packages


Original
PDF Mil-Std-1553 NHI-1523 Mil-Std-883 QML-38534 Mil-PRF-38534
1997 - Not Available

Abstract:
Text: . Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the , Mil-Std-1553 Products NHI-1523 Series + 12V Dual Transceivers Features/Applications: Description: Very Low Standby Power The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin , manchester to the coupling transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides an independent transmitter inhibit TXINH for each channel. +5V + 12V


Original
PDF Mil-Std-1553 NHI-1523 Mil-Std-883 QML-38534 Mil-PRF-38534
1997 - Not Available

Abstract:
Text: . Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the , Mil-Std-1553 Products NHI-1522 Series + 12V Dual Transceivers Features/Applications: Description: Very Low Standby Power The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin , manchester to the coupling transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides an independent transmitter inhibit TXINH for each channel. +5V + 12V


Original
PDF Mil-Std-1553 NHI-1522 Mil-Std-883 QML-38534 Mil-PRF-38534
1997 - Not Available

Abstract:
Text: with industry standard decoders. + 12V Data Bus Isolation Transformer Coupler Box Direct Or , . Technitrol part number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the , Mil-Std-1553 Products NHI-1523 Series + 12V Dual Transceivers Features/Applications: Very Low Standby , The transmitters will output bi-phase manchester to the coupling transformer when the TX and TX_L , : The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin plug-in and flatpack packages


Original
PDF Mil-Std-1553 NHI-1523 Mil-Std-883 QML-38534 Mil-PRF-38534
1997 - Not Available

Abstract:
Text: . The center tap on the transceiver side of the isolation transformer must be grounded. TXA_L , + 12V Data Bus TRANSMITTER TX TX Isolation Transformer Coupler Box TXOUT Shaping , are available in both single and dual channel, + 12V and +15V power supply source, and packaged in , Isolated Channels The transmitters will output bi-phase manchester to the coupling transformer when the , each channel. Network TXOUT_L Logic Direct Or Transformer TXINH TXVOC RECEIVER RX


Original
PDF Mil-Std-1553/MacAir NHI-1540 Mil-Std-1553A/B, A3818, A4905, A5232, A5690 470uF NHI-1540
1997 - dc control eq

Abstract:
Text: + 12V Data Bus Isolation Transformer TXOUT Coupler Box Direct Or Transformer Shaping Network , number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the isolation , transceivers are available in both single and dual channel, + 12V and +15V power supply source, and packaged in , transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides an , 30 29 28 27 26 25 24 23 22 21 20 19 Function TXA_L TXA TXINH_A +5V_A NC GND_A RXIN_A_L RXIN_A + 12V


Original
PDF Mil-Std-1553/MacAir NHI-1540 Mil-Std-1553A/B, A3818, A4905, A5232, A5690 470uF dc control eq
1997 - NHI-1540

Abstract:
Text: . The center tap on the transceiver side of the isolation transformer must be grounded. TXA_L , + 12V Data Bus TRANSMITTER TX TX Isolation Transformer Coupler Box TXOUT Shaping , are available in both single and dual channel, + 12V and +15V power supply source, and packaged in , Isolated Channels The transmitters will output bi-phase manchester to the coupling transformer when the , each channel. Network TXOUT_L Logic Direct Or Transformer TXINH TXVOC RECEIVER RX


Original
PDF Mil-Std-1553/MacAir NHI-1540 Mil-Std-1553A/B, A3818, A4905, A5232, A5690 470uF NHI-1540
Not Available

Abstract:
Text: mode for compatibility with industry standard decoders. + 12V _ J t_ Isolation Transformer Coupler Box Direct Or Transformer Data Bus r> V W Shaping Network TXOUT L RECEIVER RX RX Receive , tap on the transceiver side of the isolation transformer must be grounded. TRANSFORM ER COUPLED NHI , 516-981-8888 Mil-Std-1553 Products NHI-1523 Series + 12V Dual Transceivers Features/Applications: · Very , TXOUT Description: The NHI + 12V dual transceivers are available in 1.900" x .780", 36 pin plug-in


OCR Scan
PDF Mil-Std-1553 NHI-1523 Mil-Std-883 QML-38534 Mil-PRF-38534
Not Available

Abstract:
Text: average voltage to T 1's center tap . 52 and S3 are operating 180° out of phase with each other and at , output are applied to Q 2's gate charging L3 and supplying center tap voltage to T3. At the same time, Q and Q drive Q3 and Q4 alternately through gate drive transform er T2. T3 transform ers T 3's center tap voltage and applies it to the output rectifiers. Once the +5V output reaches approxim ately 5V , pedance makes destruction of the switches unlikely even with a transform er flux imbalance. Transformer


OCR Scan
PDF MIC3833 MIC3833. 115VAC
1997 - NHI-1540

Abstract:
Text: + 12V Data Bus Isolation Transformer TXOUT Coupler Box Direct Or Transformer Shaping Network , number Q1553-3 or equivalent is recommended. The center tap on the transceiver side of the isolation , transceivers are available in both single and dual channel, + 12V and +15V power supply source, and packaged in , transformer when the TX and TX_L inputs are driven by complementary TTL digital data. The device provides an , 30 29 28 27 26 25 24 23 22 21 20 19 Function TXA_L TXA TXINH_A +5V_A NC GND_A RXIN_A_L RXIN_A + 12V


Original
PDF Mil-Std-1553/MacAir NHI-1540 Mil-Std-1553A/B, A3818, A4905, A5232, A5690 470uF
Supplyframe Tracking Pixel