The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
TPS2661EVM TPS2661EVM ECAD Model Texas Instruments TPS2661x current loop protector evaluation module Visit Texas Instruments
BQ27741YZFR-G1 BQ27741YZFR-G1 ECAD Model Texas Instruments Pack-Side Impedance Track(tm) Fuel (Gas) Gauge with Integrated Protector 15-DSBGA -40 to 85 Visit Texas Instruments
BQ771807DPJT BQ771807DPJT ECAD Model Texas Instruments Family 2-5S Overvoltage Protector with Internal Delay Timer 8-WSON -40 to 85 Visit Texas Instruments Buy
BQ29706DSET BQ29706DSET ECAD Model Texas Instruments Li-Ion/Li Polymer Advanced Single-Cell Battery protector IC 6-WSON -40 to 85 Visit Texas Instruments Buy
UCC3911DPTR UCC3911DPTR ECAD Model Texas Instruments Lithium-Ion Battery Protector 16-SOIC -20 to 70 Visit Texas Instruments
BQ7790400PWR BQ7790400PWR ECAD Model Texas Instruments 3-4S Low-Power Protector 20-TSSOP -40 to 85 Visit Texas Instruments Buy

125ew-r protector Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
rj11 jack

Abstract: 2377-45-HS 2378-35-HS 7004C 85122-T-IDC
Text: Features Accepts POTS lines & coaxial protector Subscriber lockable with Telco override , for a maximum of two POTS lines and one 1740-xx coax protector . The 7004C features convenient cable , Number Designator Number of Twisted Pairs 0 = None 1 = One 2 = Two Station Protector Options D 1 = , -BC) Balance-Sensitive DSL (UL, cUL) K= 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R


Original
PDF E53117) 7004C 1740-xx gene5122-IDC) 85122-T4* 85122-IDC rj11 jack 2377-45-HS 2378-35-HS 85122-T-IDC
adsl splitter circuit diagram

Abstract: rj11 jack 2377-45-HS 2378-35-HS
Text: Station Protector Options D1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) U3 = 455HS-MSP (2377-45 , ) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R (2375-01) Dual Gas Tube (UL, cUL, RUS) L = 356M , (4-post sealed switching jacks). Example 7005-01-EFP-P1 To add lines, use station protector + 85122 , Device Installation Diagrams POTS SPLITTER (ON TOP) PROTECTOR (ON BOTTOM) MOUNTING POST PROTECTOR


Original
PDF E53117) 85122-T4* 85122-IDC 85122-B 85122-T-IDC* adsl splitter circuit diagram rj11 jack 2377-45-HS 2378-35-HS
Tii355M

Abstract: 125ew 708X 2377-45-HS 2378-35-HS 2378-35-BC
Text: upgrading kits. The installer simply needs to add the Station Protector and connect the internal wiring , ) MM (INCHES) Number of Protectors 01 = One Protector 02 = Two Protectors Protector Options D1 , -BC) Balance-Sensitive DSL Systems B= C= L= M= T= O= 125EW (2374-01) Sealed Gas Tube (UL, Bellcore) 125EW- R


Original
PDF RJ-11 E53117) 155HS-MSP 2378-35-HS) 155HS-BC 2378-35-BC) 125EW 125EW-R J130S Tii355M Tii355M 125ew 708X 2377-45-HS 2378-35-HS 2378-35-BC
3610a2

Abstract: ADSL splitter Y splitter rj11 jack 2377-45-HS 2378-35-HS TR BC
Text: Number of Twisted Pairs 1 = One 3 = Three 5 = Five 2 = Two 4 = Four 6 = Six Station Protector , -BC) Balance-Sensitive DSL (UL, cUL) K= 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R , To add lines, use station protector + 85122 Standard Jack (Not available with DSL configurations , SPLITTER (ON TOP) STATION PROTECTOR 85122-T4 POTS MODULE PROTECTOR (ON BOTTOM) GROUND


Original
PDF E53117) 85122-T 85122-T4* 85122-IDC 85122-T-IDC* 85122-B 3610a2 ADSL splitter Y splitter rj11 jack 2377-45-HS 2378-35-HS TR BC
adsl splitter circuit diagram

Abstract: phone and modem splitter circuit diagram VDSL splitter adsl dual pot splitter circuit diagram vdsl splitter circuit diagram M 7004 125EW-R (2375-01) Dual Gas Tube 7004 ADSL splitter circuit 125ew-r protector
Text: 4 = Four Station Protector Options D1 =455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) Z1 = 455HS , Gas Tube (UL, cUL, Telcordia) 125EW- R (2375-01) Dual Gas Tube (UL, cUL, RUS) 356M (2377-01) Balanced Gas Tube (UL, cUL, RUS) J130S (2380-27-01) Solid State Protector (UL, cUL) Tii355M No Station , , use station protector + 85122 Standard Jack (Not available with DSL configurations) 85122 , . 7004 Series - Network Interface Device Installation Diagrams MOUNTING POST STATION PROTECTOR


Original
PDF E53117) 85122-T 85122-T4* 85122-IDC 85122-T-IDC* 85122-B adsl splitter circuit diagram phone and modem splitter circuit diagram VDSL splitter adsl dual pot splitter circuit diagram vdsl splitter circuit diagram M 7004 125EW-R (2375-01) Dual Gas Tube 7004 ADSL splitter circuit 125ew-r protector
2007 - adsl splitter circuit diagram

Abstract: adsl dual pot splitter circuit diagram rj11 jack vdsl splitter circuit diagram 2377-45-HS 2378-35-HS 2377-35-G
Text: T E L O S B O Station Protector Options D1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL , Back-Up-Gap (UL, cUL) B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R (2375-01) Dual Gas , add lines, use station protector + 85122 Standard Jack (Not available with DSL configurations , ) PROTECTOR (ON BOTTOM) MOUNTING POST PROTECTOR POTS SPLITTER MOUNTING POST E T E L O S B


Original
PDF E53117) 85122-T4* 85122-IDC 85122-B 85122-T-IDC* adsl splitter circuit diagram adsl dual pot splitter circuit diagram rj11 jack vdsl splitter circuit diagram 2377-45-HS 2378-35-HS 2377-35-G
adsl splitter circuit diagram

Abstract: adsl dual pot splitter circuit diagram 3610A ADSL splitter rj11 jack vdsl splitter circuit diagram 2377-45-HS 2378-35-HS splitter vdsl
Text: Protector 4 = Two 1740-xx Coax Protectors Number of Twisted Pairs 1 = One 2 = Two 4 = Four 3 = Three Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) U 3 = 455HS , -G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R (2375-01) Dual Gas Tube (UL, cUL , No options (standard 85122 jack) Coax Protector Type 2 = 1740-15 (150 V±20 % DC Breakdown @ 100 V


Original
PDF E53117) 85122-T4* 85122-IDC 85122-T-IDC* 85122-B adsl splitter circuit diagram adsl dual pot splitter circuit diagram 3610A ADSL splitter rj11 jack vdsl splitter circuit diagram 2377-45-HS 2378-35-HS splitter vdsl
2374-01

Abstract: 2375-01 125EW-R 125EW PE-80 10-32 UNF 2A
Text: -EW/EW-R Series ­ Sealed Gas Tube Station Protector Bourns® 125-EW/-EW-R Series type station protectors , protector element for each line consists of a heavy-duty-rated, two-element gas tube, an external backup gap , protector housings and network interface devices. Characteristics Test Methods per IEEE C62.31, UL 497 , . -55 to +85 °C * NOTE: Either protector module will comply with both specifications. The only , specific applications. 125-EW/EW-R Series ­ Sealed Gas Tube Station Protector How To Order Model 125


Original
PDF E53117) 125-EW/EW-R 125-EW/-EW-R 2374-01 2375-01 125EW-R 125EW PE-80 10-32 UNF 2A
Tii355M

Abstract: 125ew 2377-45-HS 2378-35-HS 7004C 85122-T-IDC 125ew protector
Text: Features Accepts POTS lines & Coaxial Protector Manufactured from high-impact resistant , for a maximum of two POTS lines and one 1740-xx coax protector . The 7004C features convenient cable , Number Designator Number of Twisted Pairs 0 = None 1 = One 2 = Two Station Protector Options D1 = , -BC) Balance-Sensitive DSL (UL, cUL) B= C= L= M= T= O= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) 125EW- R , ) Solid State Protector (UL, cUL) Tii355M No Station Protectors *For DSL systems requiring capacitive


Original
PDF E53117) 7004C 1740-xx 85122-T4* 85122-IDC 85122-T-IDC* Tii355M 125ew 2377-45-HS 2378-35-HS 85122-T-IDC 125ew protector
2010 - QMP11A5

Abstract: 391SVSR2 455BC adsl2 modem D5036 s76A 351SVSR2 type 139 screw terminal can style 7090-01-DF BURN TUBE ss CONDUIT ACCESSORIES
Text: process. The plug-in protectors and connection products through patented Multi-Stage Protector (MSP , protector footprints, the of surge protection and connection products for Telco central office, outside , . The Bourns® MSP® Protector Advantage Multi-Stage Protection 2430-41-G-MSP The Best of Two , (BUG), thereby eliminating BUGrelated contamination within the protector as a potential cause of , fast, resettable sneak-current protection new generation of surge protector designed to be with


Original
PDF CG-391 7032-25-ECO 7004-01-WIS-P1-I 2430-41-G-MSP 2378-35-HS 2377-45-HS 2377-45-HS-IDC 2420-31-G 3610A2 2377-35-G-IDC QMP11A5 391SVSR2 455BC adsl2 modem D5036 s76A 351SVSR2 type 139 screw terminal can style 7090-01-DF BURN TUBE ss CONDUIT ACCESSORIES
2378-35-BC

Abstract: 2377-45-HS 2378-35-HS 125EW 125EW-R 7070
Text: Bourns Digi.Guard MSP® Protectors. All protector modules are easily field replaceable. Product , Number Designator Number of Lines 06, 12, 25, 50, 100 Station Protector Options D1 = 455HS , Systems B = C= L = M= T = O= R = 125EW (2374-01) Sealed Gas Tube (UL, Bellcore) 125EW- R (2375-01 , ) Solid State Protector (UL) Tii355M No Station Protectors Binding posts only/no protectors Reliable


Original
PDF E53117) 2378-35-BC 2377-45-HS 2378-35-HS 125EW 125EW-R 7070
2006 - ADSL2 splitter bourns

Abstract: 3610A
Text: VDSL POTS Splitter and Station Protector Two large grommet service and subscriber wire ports , Line (only option with DSL) 02 = Two Lines Station Protector Options D1 = 455HS-MSP (2377-45 , 125EW (2374-01) Sealed Gas Tube (UL, Bellcore) C = 125EW- R (2375-01) Sealed Gas Tube (REA, UL, CSA) L =


Original
PDF E53117) 85122-T4 ADSL2 splitter bourns 3610A
adsl splitter circuit diagram

Abstract: ADSL2 Modem circuit diagram 455HS 125ew adsl dual pot splitter circuit diagram Wiring Diagram logo 2377-45-HS 2378-35-HS 7040 Tii355M
Text: per UL 497 & 1863 ® (File: E53117, E116756) 7040 Series ­ Station Protector Enclosure The Model 7040 Series Station Protector is designed to protect telecommunication network services from , /VDSL POTS Splitter and one Station Protector . The 7040 features a versatile, weather resistant , Two Lines DIMENSIONS: Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL , = 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No


Original
PDF E53117, E116756) 3610A2 3610A2-IDC adsl splitter circuit diagram ADSL2 Modem circuit diagram 455HS 125ew adsl dual pot splitter circuit diagram Wiring Diagram logo 2377-45-HS 2378-35-HS 7040 Tii355M
2007 - 125ew-r protector

Abstract: 125ew 2377 708X 2377-45-HS 2378-35-HS
Text: kits. The installer simply needs to add the Station Protector and connect the internal wiring when , High 167.6 (6.6) Wide 88.9 (3.5) DIMENSIONS: Number of Protectors 01 = One Protector 02 = Two Protectors Deep 50.8 (2.0) MM (INCHES) Protector Options D 1 = 455HS-MSP (2377-45 , -BC) Balance-Sensitive DSL (UL, cUL) K= 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R


Original
PDF RJ-11 E53117) 125EW-R Tii355M 125ew-r protector 125ew 2377 708X 2377-45-HS 2378-35-HS
7032

Abstract: plywood rj11 jack 2377-45-HS 2378-35-HS 85122-T-IDC
Text: Number Designator Number of Lines 06, 12, 25, 50, 100 Station Protector Options D 1 = 455HS , -BC) Balance-Sensitive DSL (UL, cUL) K = 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R , DSL Lines 03, 06, 12, 25, 50 To add lines, use station protector + upgrade kit 85003 (old style) or


Original
PDF E53117) 85122-T4* 85122-IDC 85122-B 85122-T-IDC* 5111-A 7032-xx-xAx 85111-B 7032-xx-xBx 5111-A 7032 plywood rj11 jack 2377-45-HS 2378-35-HS 85122-T-IDC
3610A

Abstract: ADSL splitter dsl modem 2380-27-01 125EW 125EW-R 2377-45-HS 2378-35-HS 13610A 2378-35-BC
Text: Number of Twisted Pairs 1 = One 3 = Three 5 = Five 2 = Two 4 = Four 6 = Six Station Protector , -BC) Balance-Sensitive DSL (UL, cUL) B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R (2375-01) Dual , ) Solid State Protector (UL, cUL) T = Tii355M O = No Station Protectors (Not available with DSL , station protector + 85122 Standard Jack (Not available with DSL configurations) 85122-T4 Sealed , TOP) STATION PROTECTOR 85122-T4 POTS MODULE PROTECTOR (ON BOTTOM) GROUND TERMINAL


Original
PDF E53117) 85122-T 85122-T4* 85122-IDC 85122-T-IDC* 85122-B 3610A ADSL splitter dsl modem 2380-27-01 125EW 125EW-R 2377-45-HS 2378-35-HS 13610A 2378-35-BC
7032

Abstract: plywood 125EW 125EW-R 2377-45-HS 2378-35-HS 85122-T-IDC 3610A TR BC
Text: XX Model Number Designator Number of Lines 06, 12, 25, 50, 100 Station Protector Options D1 = , -BC) Balance-Sensitive DSL Systems B= C= L= M= T= O= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) 125EW- R , ) Solid State Protector (UL, cUL) Tii355M No Station Protectors (Not available with DSL configurations , , 06, 12, 25, 50 To add lines, use station protector + upgrade kit 85003 (old style) or: 85122


Original
PDF E53117) 85122-T4* 85122-IDC 85122-T-IDC* 85122-B 7032 plywood 125EW 125EW-R 2377-45-HS 2378-35-HS 85122-T-IDC 3610A TR BC
adsl splitter circuit diagram

Abstract: ADSL splitter adsl dual pot splitter circuit diagram rj11 jack Y splitter 2377-45-HS 2378-35-HS binding post RJ11 7091
Text: XX Model Number Designator Number of Coax Protectors 0 = None 3 = One 1740-xx Coax Protector , Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) U 3 = 455HS-MSP (2377-45 , Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R (2375-01) Dual Gas Tube (UL, cUL, RUS) L= 356M , Protector Type 2 = 1740-15 (150 V±20 % DC Breakdown @ 100 V/Sec) 3 = 1740-23 (230 V±20 % DC Breakdown @


Original
PDF E53117) 85122-T4* 85122-IDC 85122-IDC* 85122-B adsl splitter circuit diagram ADSL splitter adsl dual pot splitter circuit diagram rj11 jack Y splitter 2377-45-HS 2378-35-HS binding post RJ11 7091
7004

Abstract: adsl splitter circuit diagram ADSL2 Modem circuit diagram adsl dual pot splitter circuit diagram phone and modem splitter circuit diagram rj11 jack RJ11 p2 RJ11 WIRING diagram VDSL2 Modem circuit diagram 2377-45-HS
Text: Two 4 = Four Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) U 3 = , (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R (2375-01) Dual Gas Tube , ) 3670-01 BalUn Module R1 = (1) 3660 Equalization Module To add lines, use station protector + 85122 , . 7004 Series - Network Interface Device Installation Diagrams MOUNTING POST STATION PROTECTOR


Original
PDF E53117) knock22-T 85122-T4* 85122-IDC 85122-T-IDC* 85122-B 7004 adsl splitter circuit diagram ADSL2 Modem circuit diagram adsl dual pot splitter circuit diagram phone and modem splitter circuit diagram rj11 jack RJ11 p2 RJ11 WIRING diagram VDSL2 Modem circuit diagram 2377-45-HS
3610A2-IDC

Abstract: dsl modem ADSL2 splitter ADSL2 splitter bourns rj11 jack RJ11 jack dimension RJ11 p2 2377-45-HS 2378-35-HS 85122-T-IDC
Text: Number of Twisted Pairs 1 = One 3 = Three 5 = Five 2 = Two 4 = Four 6 = Six Station Protector , -BC) Balance-Sensitive DSL (UL, cUL) K= 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B= 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C= 125EW- R , Equalization Modules To add lines, use station protector + 85122 Standard Jack (Not available with DSL , Device POTS Splitter Installation MOUNTING POST POTS SPLITTER (ON TOP) STATION PROTECTOR


Original
PDF E53117) 85122-T 85122-T4* 85122-IDC 85122-T-IDC* 85122-B 3610A2-IDC dsl modem ADSL2 splitter ADSL2 splitter bourns rj11 jack RJ11 jack dimension RJ11 p2 2377-45-HS 2378-35-HS 85122-T-IDC
2002 - RJ11 y splitter

Abstract: 709132 85122-T4 125EW 2377-45-HS 2378-35-HS binding post RJ11
Text: Number of Coax Lines 0 = None 3 = Includes One 1740 Coax Protector 4 = Includes Two 1740 Coax , Protector Options D1 = 455HS-MSP (2377-45-HS) Broadband Voice/Data Services Z1 = 455HS-BC* (2377-45 , -BC) Balance-Sensitive DSL Systems B = 125EW (2374-01) Sealed Gas Tube (UL, Bellcore) C = 125EW- R (2375-01) Sealed Gas , Options Coax Protector Type 2 = 1740-15 (150V±20% DC Breakdown @ 100V/Sec) 3 = 1740-23 (230V±20% DC , Protector Options D, Z, E or Y only. 7090 NIDs ordered with either 3610A or 3630A will include Special


Original
PDF E53117) 7091-32-XFX-A2 7091-33-XFX-A1 7091-41-XXX 7091-42-XXX 7091-44-XXX 7091-41-XFX-A1 7091-42-XFX-A1 7091-42-XFX-A2 RJ11 y splitter 709132 85122-T4 125EW 2377-45-HS 2378-35-HS binding post RJ11
125ew

Abstract: 125EW-R 2377-45-HS 2378-35-HS 125ew-r protector
Text: Bourns Digi.Guard MSP® Protectors. All protector modules are easily field replaceable. Product , of Lines 06, 12, 25, 50, 100 Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL , 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R (2375-01) Dual Gas


Original
PDF E53117) 125ew 125EW-R 2377-45-HS 2378-35-HS 125ew-r protector
c k 7101 switch

Abstract: 2377-45-HS 2378-35-HS RJ11 jack 3.5 mm ADSL2 splitter bourns 455HS-BC
Text: Twelve 50 = Fifty Station Protector Options D 1 = 455HS-MSP (2377-45-HS) Voice/Data/DSL (UL,cUL) U 3 , 356G (2377-35-G) Balanced GDT, No Back-Up-Gap (UL, cUL) R 3 = 356G (2377-35-G-IDC) Balanced GDT, No Back-Up-Gap (UL, cUL) B = 125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia) C = 125EW- R (2375-01) Dual Gas


Original
PDF 18-gauge E53117) 3610A2, 3610A2-IDC, 7101-12-DCO-P12 c k 7101 switch 2377-45-HS 2378-35-HS RJ11 jack 3.5 mm ADSL2 splitter bourns 455HS-BC
2008 - 455BC

Abstract: 2377-45-HS bourns 4020-01 2430-41-G 4010-01 455BC-MSP 7040-02-D 2410-39-G-MSP 2022-60A MSP 2410
Text: products. Responsiveness to the voice of our customers Protector (MSP®) devices are available in 5-pins, is the cornerstone of our business philosophy at Bourns. industry standard station protector , ) Series of station 2 The Bourns® MSP® Protector Advantage Multi-Stage Protection 2430-41 , Back Up Gap (BUG), thereby eliminating BUGrelated contamination within the protector as a potential , Protector Options D1 - 455HS-MSP (2377-45-HS) Voice / DSL / Data (UL, cUL) U3 - 455HS-MSP (2377-45


Original
PDF 7091-32-DF2 7004-01-WIS-P1-I 7032-25-ECO 7004-01-EF-P1 2378-35-HS 2430-41-G-MSP 2377-45-HS 2377-45-HS-IDC 2420-31-G 3610A2 455BC 2377-45-HS bourns 4020-01 2430-41-G 4010-01 455BC-MSP 7040-02-D 2410-39-G-MSP 2022-60A MSP 2410
Not Available

Abstract: No abstract text available
Text: Latchup-Proof Construction Single Channel Protector in an SOT-23 Package ADG465 FUNCTIONAL BLOCK DIAGRAM , single channel protector in an SOT-23 pack­ age. The channel protector is placed in series with the , channel protector consists of an n-channel M O SFE T , a p-channel M O SFET and an n-channel M O SFET, connected in series. The channel protector behaves like a series resistor dur­ ing normal operation, i.e , Dual Supply1 (V jjs+ IS V .V ssrr-IS V , GND = P a ra m e te r OV, unless otherwise noted) FAULT


OCR Scan
PDF OT-23 ADG465 ADG465
Supplyframe Tracking Pixel