2009 - IEC-61754-7
Abstract: TIA-604 EIA-455-21A EIA-455-21 EIA-455 FOCIS 5 F12D5 F912D5-5MY F912D5-5M FX12D5-5M30Y
Text: * 12-fiber connector on each end of laser optimized OM3 fiber and OM4 fiber or OM1, OM2 or OS1 fiber , meet or exceed the requirements of TIA/EIA-568-B.3. The MTP* 12-fiber connector shall exceed the , uniform fiber height, low insertion loss and excellent return loss performance across the 12-fiber , * Cassettes 6 LC to MTP* ( 12-fiber ): FCXO-12-10Y 12 LC to 2 MTP* (24- fiber ): FCXO-24-10Y 6 SC to MTP* ( 12-fiber ): FCXO-12-3Y QuickNet TM 10Gig TM 50/125m OM3 and OM4 Pre-Terminated MTP* Cassettes 6 LC to MTP* ( 12-fiber
|
Original
|
PDF
|
12-fiber
TIA/EIA-568-B
TIA/EIA-455-21A
FBSP23
WW-FBSP23
IEC-61754-7
TIA-604
EIA-455-21A
EIA-455-21
EIA-455
FOCIS 5
F12D5
F912D5-5MY
F912D5-5M
FX12D5-5M30Y
|
2007 - IEC-61754-7
Abstract: FOCIS 5 FCE1U FX12D5-5M30Y
Text: * 12-fiber connector on each end of laser optimized OM3 fiber or OM1, OM2 or OS1 fiber . Jacketed cable , exceed the requirements of TIA/EIA-568-B.3. The MTP* 12-fiber connector shall exceed the requirements of , fiber height, low insertion loss and excellent return loss performance across the 12-fiber interface , MTP* ( 12-fiber ): FCXO-12-10Y 12 LC to 2 MTP* (24- fiber ): FCXO-24-10Y 6 SC to MTP* ( 12-fiber ): FCXO-12-3Y QUICKNET TM 10GIG TM 50/125µm OM3 Pre-Terminated MTP* Cassettes 6 LC to MTP* ( 12-fiber ): 12 LC to 2 MTP
|
Original
|
PDF
|
12-fiber
TIA/EIA-568-B
TIA/EIA-455-21A
FBSP23
WW-FBSP23
IEC-61754-7
FOCIS 5
FCE1U
FX12D5-5M30Y
|
2001 - FTC-SCS111
Abstract: FOA-INLC015 FOA-INFC10 FTC-CNSM02 FL2000 FOA-INSC05 FBA-SCZNF
Text: Cable Assemblies and Accessories Ripcord Ripcord Standard Wall (4- Fiber Shown) Soft Wall ( 12-Fiber , (blue) 12-fiber standard wall with 1.7 mm subunits 12-fiber soft wall with 900 µm buffered fiber 12-fiber , mm thick Buffered Fiber 900 µm Fiber Cable Assemblies and Accessories Soft Wall ( 12-Fiber , , 62.5/125 µm 12-fiber soft wall, 62.5/125 µm 6- fiber soft wall, 50/125 µm 12-fiber soft wall, 50/125 µm 6- fiber soft wall, 50/125 µm laser optimized to 300 m (aqua) 12-fiber soft wall, 50/125 µm laser
|
Original
|
PDF
|
102880AE
FTC-SCS111
FOA-INLC015
FOA-INFC10
FTC-CNSM02
FL2000
FOA-INSC05
FBA-SCZNF
|
VOL-H54L1
Abstract: b548 fiber patch panels Infinicor 600 corning fiber optic cables VOL-H52L1 Corning infinicor Corning Infinicor 600 50/125 fiber cable ofnr tm 1640
Text: (250) VOL-B512R1 Backbone 50/125 µm, 12-fiber Riser 76 (250) VOL-B524R1 Backbone 50/125 , ) VOL-B56L1 Backbone 50/125 µm, 6- fiber LSZH 500 (1640) VOL-B512L1 Backbone 50/125 µm, 12-fiber , (250) VOL-B512P1 Backbone 50/125 µm, 12-fiber Plenum 76 (250) VOL-B524P1 Backbone 50/125 , 6- fiber 7.8 / 5.2 150 lb. / 660 N 5.2 mm / 0.205 in. VOL-B512P1 12-fiber 7.2 / 4.8 150 lb. / 660 N 5.6 mm / 0.220 in. VOL-B512R1 12-fiber 8.4 / 5.6 150 lb. / 660 N 5.6
|
Original
|
PDF
|
VF-45TM
VF-45
VOL-H54L1
b548
fiber patch panels
Infinicor 600
corning fiber optic cables
VOL-H52L1
Corning infinicor
Corning Infinicor 600 50/125
fiber cable ofnr
tm 1640
|
2004 - CCH-CM24-05-93S
Abstract: HDH-CM24 024xsf-a8076d20 fiber HDH-CM12-57-93S FAN-BT25-12 HDH-CM24-05-93S CCH-CP24-E4 otdr 048XW4-CJ663D20 048XWF-CJ669D20
Text: , ceramic, 50 µm LOMMF UniCam Connector EliteTM Tool Kit UniCam MTP ® Connector, 50 µm LOMMF, 12-fiber black housing and aqua boot, no pins UniCam MTP Connector, 50 µm LOMMF, 12-fiber black housing and aqua boot , fiber counts) 2-24 fiber , SM (6, 12, 18, 24 std fiber counts) 12-fiber hybrid, 6 SM/6 Pretium 550, 50 µm , A959512S8800xxxF A959524S8800xxxF Plug & Play Systems Trunk Cable Photo LAN517 Description Trunk, 12-fiber , , 12-fiber , Pretium 300, 50 µm LOMMF CCH Plug & Play Module, 0.75 dB IL, LC/MTP ceramic, 24- fiber
|
Original
|
PDF
|
95-050-41-X
95-050-98-X
93-051-69-X
93-051-70-X
00xS88-31190-29
0xxS88-33190-29
12-fiber
LAN-603-EN
CCH-CM24-05-93S
HDH-CM24
024xsf-a8076d20 fiber
HDH-CM12-57-93S
FAN-BT25-12
HDH-CM24-05-93S
CCH-CP24-E4
otdr
048XW4-CJ663D20
048XWF-CJ669D20
|
2007 - Not Available
Abstract: No abstract text available
Text: * 12-fiber connector on each end of laser optimized OM3 fiber or OM1, OM2 or OS1 fiber . Jacketed cable , exceed the requirements of TIA/EIA-568-B.3. The MTP* 12-fiber connector shall exceed the requirements of , fiber height, low insertion loss and excellent return loss performance across the 12-fiber interface , MTP* ( 12-fiber ): FCXO-12-10Y 12 LC to 2 MTP* (24- fiber ): FCXO-24-10Y 6 SC to MTP* ( 12-fiber ): FCXO-12-3Y QUICKNET TM 10GIG TM 50/125µm OM3 Pre-Terminated MTP* Cassettes 6 LC to MTP* ( 12-fiber ): 12 LC to 2 MTP
|
Original
|
PDF
|
12-fiber
TIA/EIA-568-B
TIA/EIA-455-21A
FBSP23
WW-FBSP23
|
2285XQ
Abstract: 19XT-062T P2020A-C-125 Nec 2651a 3M Photodyne laser source MT 8223 photodyne 18xta 19XT-010J 3M Photodyne 1700-0850-T
Text: ) MULTI-FIBER STRIPPER TUBE GUIDE ( 12-FIBER BONDED) MULTI-FIBER STRIPPER TUBE GUIDE (12 FIBER AT&T ASR) MULTI-FIBER STRIPPER TUBE GUIDE ( 12-FIBER ENCAPSULATED) MULTI-FIBER STRIPPER TUBE GUIDE (10 FIBER BONDED , ASSY ( 12-FIBER AT&T ASR) MULTI-FIBER HOLDER ASSY ( 12-FIBER BONDED) MULTI-RBER HOLDER ASSY ( 12-FIBER , 3MTM Fiber Optics Cable Assemblies (Connectors, Couplings) Cable Assemblies (Connectors, Couplings , 8119 COUPLING ST SM 8412-TM 12 PORT PLATE ST 3MTM Fiber Optics Description COUPLING ST MULTIMODE
|
OCR Scan
|
PDF
|
125/UM
9/125UM,
OD-94
9/125UM
50/125UM
2285XQ
19XT-062T
P2020A-C-125
Nec 2651a
3M Photodyne laser source
MT 8223
photodyne 18xta
19XT-010J
3M Photodyne
1700-0850-T
|
2001 - FOA-INLC015
Abstract: FTC-SCS111 FBA-SCZNF
Text: ripcord Standard Wall (4- Fiber Shown) Soft Wall ( 12-Fiber Shown) Catalog Number FPM-0 _ / _ - , 900 µm buffered fiber 8- fiber reduced bend radius with 1.7 mm subunits 12-fiber standard wall with 1.7 mm subunits 12-fiber soft wall with 900 µm buffered fiber 12-fiber reduced bend radius with 1.7 mm , Cable Assemblies and Accessories Soft Wall ( 12-Fiber Shown) Catalog Number MFPM _ / _ - _ _ _ , µm 12-fiber soft wall, 62.5/125 µm 6- fiber soft wall, 50/125 µm 12-fiber soft wall, 50/125 µm 6- fiber
|
Original
|
PDF
|
102880AE
FOA-INLC015
FTC-SCS111
FBA-SCZNF
|
2013 - Not Available
Abstract: No abstract text available
Text: MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , RRP131324UPNM8S075F_NAFTA_AEN Page 3 | Revision date 2013-03-02 MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP , (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP (non-pinned), 24 Fiber , 75 ft Fiber
|
Original
|
PDF
|
12-fiber
RRP131324UPNM8S075F
RRP131324UPNM8S075F
|
2001 - WCH-04P
Abstract: pinless CONNECTOR WCH-12P WCH-02P Corning Infinicor 300 WCH-06P SIECOR Fiber Optic cable SM 98 Infinicor 600 CCH-01U
Text: : MTP-to-MTP Trunks consist of preconnectorized trunks with MTP ® 12-fiber connectors. This solution includes , Standard Fiber Count. 12 = 12-fiber 24 = 24- fiber 36 = 36- fiber 48 = 48- fiber 72 = 72- fiber 5 R K C Select , . 4 Select Standard Fiber Count. 12 = 12-fiber 24 = 24- fiber 36 = 36- fiber 48 = 48- fiber 72 = 72- fiber , is a 12-fiber connector with a footprint similar to Corning Cable Systems' SC Simplex connector. Like , connector type allows the user of a compact 12-fiber ribbon cable instead of bulkier simplex cable or
|
Original
|
PDF
|
|
2013 - Not Available
Abstract: No abstract text available
Text: MDU, RPDpass® Riser, Pull-Down, SM ZBL 12-fiber MTP® (non-pinned) to (2) 6- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL 12-fiber MTP® (non-pinned) to (2) 6- fiber MTP (non-pinned , MDU, RPDpass® Riser, Pull-Down, SM ZBL 12-fiber MTP® (non-pinned) to (2) 6- fiber MTP (non-pinned , , Pull-Down, SM ZBL 12-fiber MTP® (non-pinned) to (2) 6- fiber MTP (non-pinned), 12 Fiber , 100 ft , | Revision date 2013-03-02 MDU, RPDpass® Riser, Pull-Down, SM ZBL 12-fiber MTP® (non-pinned) to (2) 6- fiber
|
Original
|
PDF
|
12-fiber
RRP131312UPNM6S100F
RRP131312UPNM6S100F
|
2013 - Not Available
Abstract: No abstract text available
Text: MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , RRP131324UPNM8S100F_NAFTA_AEN Page 3 | Revision date 2013-03-02 MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP , (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP (non-pinned), 24 Fiber , 100 ft Fiber
|
Original
|
PDF
|
12-fiber
RRP131324UPNM8S100F
RRP131324UPNM8S100F
|
M50-TB01-C6NPW
Abstract: M62DX02C3NRO20 FS09-AR12-LRB M50-TB01 S09TB01CNPW VDX988S3FISC corning optical fiber cable patch cord PM15-U25 S37A7AS3FISC M9W811
Text: SINGLEMODE STOCK PATCHCORDS Fiber optic cable assemblies from Fiber Instrument Sales provide the highest , fiber . FIS 10 Gigabit assemblies are designed to run advanced applications, meet IEEE 802.3 , (slow or fast axis) Fiber Specifications, Cable Jacket (900µm buffer or 3.0mm), whether or not the , lengths. See page 31. Specify Fibercore Limited PM fiber or Corning PM Fiber . PART # DESCRIPTION S , Adapter Ceramic Sleeve 26 HIGH PERFORMANCE PATCHCORDS GGP FIBER PATCHCORDS FIS now exclusively
|
Original
|
PDF
|
S288M1FISC
S288M2FISC
S288M3FISC
S288M5FISC
S288M10FISC
D288M1FISC
D288M2FISC
D288M3FISC
D288M5FISC
D288M10FISC
M50-TB01-C6NPW
M62DX02C3NRO20
FS09-AR12-LRB
M50-TB01
S09TB01CNPW
VDX988S3FISC
corning optical fiber cable patch cord
PM15-U25
S37A7AS3FISC
M9W811
|
2001 - E2000 connector
Abstract: 96-fiber Fiber Optic Technical Training Manual FOA-INFC05 FIBER PATCH CORD P005 skkt26/16 FOA-INSC15 FTC-SCS111 FOA-INSC05
Text: soft wall 8- fiber soft wall 12-fiber standard wall 12-fiber soft wall 24- fiber thick wall , 12-fiber soft wall, 62.5/125 Ordering Examples MFPM-9/X-PB008M: Multifiber patch cord with SC , 150 meters Cable Type* A 12-fiber B 24- fiber C 36- fiber 2 48- fiber V 72- fiber L 96- fiber NA 12-fiber HA 24- fiber MA 36- fiber JA 48- fiber DS 72- fiber LA 96- fiber stranded stranded , .5® ultra polish Length (In meters) Example: 050 = 50 meters 125 = 125 meters Cable Type AB 12-fiber
|
Original
|
PDF
|
100300PR
E2000 connector
96-fiber
Fiber Optic Technical Training Manual
FOA-INFC05
FIBER PATCH CORD
P005
skkt26/16
FOA-INSC15
FTC-SCS111
FOA-INSC05
|
|
Not Available
Abstract: No abstract text available
Text: INTERCONNECT CABLES P a rt N u m b ers AMP Interconnect Cable from 1 to 4 fiber counts is available for all key fiber types and flammability requirements. All are designed to meet or exceed all , 62.5/125 fiber is compliant to ISO/IEC 11801:1995. F ib e r Type C a ble Type S in g le m o d e , â â 502987-4 502987-2 5 0 2 9 8 7 -1 4 Fiber 502988-4 502988-2 5 0 2 9 8 8 , Fiber (LSZH) 503016-1 502983-2 4 Fiber Low Smoke 503016-2 502983-4 DUALAN
|
OCR Scan
|
PDF
|
GR-409-CORE.
|
2004 - Not Available
Abstract: No abstract text available
Text: ribbon 1374887-X 8- fiber LIGHTRAY MPX (m) to LIGHTRAY MPX (f) assy., jacketed ribbon 1374892-X 12-fiber LIGHTRAY MPX (m) to LIGHTRAY MPX (m) assy., bare ribbon 1374743-X 12-fiber LIGHTRAY MPX (f) to LIGHTRAY MPX (f) assy., bare ribbon 1374601-X 12-fiber LIGHTRAY MPX (f) to LIGHTRAY MPX (f) assy., round cable 1278110-X 12-fiber LIGHTRAY MPX (m) assy. to (12) SC, 900µm buffered fibers 492514-X 12-fiber , ) pigtail assy., jacketed ribbon 1457645-X 12-fiber LIGHTRAY MPX (f) pigtail assy., bare ribbon 1374788
|
Original
|
PDF
|
|
GR-20-CORE
Abstract: AFL Telecommunications CP012 1C101 551001 Telcordia GR-20-CORE color GR-409-CORE OUTDOOR FIBRE OPTIC CABLE 6381 AFL optic
Text: · Indoor/Outdoor Plenum Tight Buffered Cable · Breakout Cable · RIBBON-Link® Cable fiber optic cable premise products P-1 AFL Telecommunications AFL-Link® brand of optical fiber cables , years of fiber optic cabling experience in developing its full line of premise tight-buffered cables , need to flounder with commonly stiff and inflexible high fiber count trunk cables. AFL , flexibility of equal fiber count distribution cables. For interconnect applications, we offer the broadest
|
Original
|
PDF
|
WR006
WP008
WE004
WR004
WP006
WP004
GR-20-CORE
AFL Telecommunications
CP012
1C101
551001
Telcordia GR-20-CORE color
GR-409-CORE
OUTDOOR FIBRE OPTIC CABLE
6381
AFL optic
|
2002 - FPM-07
Abstract: aramid yarn FOA-INLX07
Text: with 1.7 mm subunits 6- fiber soft wall 8- fiber soft wall 12-fiber standard wall with 1.7 mm subunits 12-fiber , meters Addendum Cable Type* A 12-fiber B 24- fiber C 36- fiber 2 48- fiber V 72- fiber L 96- fiber NA 12-fiber , Fiber Optic Patch Cords Singlemode With LX.5® Small-Form-Factor Connectors Addendum , 0 0 - 3 6 6 - 3 8 9 1 1 Fiber Optic Patch Cords Multimode With LX.5® Small-Form-Factor , 1238275 Fiber Size A B 50/125 62.5/125 Connector Type MLX5 LX.5®* MDLX LX.5® duplex* 7/02 ·
|
Original
|
PDF
|
FOA-INLX03
FOA-INLX05
FOA-INLX07
FOA-INLX10
FOA-INLX12
FOA-INLX15
FOA-INLX20
FOA-INALX03
FOA-INALX05
FOA-INALX07
FPM-07
aramid yarn
|
2002 - E2000 advantages
Abstract: fl1a FOA-INLX07
Text: with 1.7 mm subunits 6- fiber soft wall 8- fiber soft wall 12-fiber standard wall with 1.7 mm subunits 12-fiber , .5® ultra polish Length (In meters) Example: 020 = 50 meters 150 = 150 meters Cable Type* A 12-fiber B 24- fiber C 36- fiber 2 48- fiber V 72- fiber L 96- fiber NA 12-fiber HA 24- fiber MA 36- fiber JA 48- fiber , Fiber Optic Patch Cords Singlemode With LX.5® Small-Form-Factor Connectors Addendum , 0 0 - 3 6 6 - 3 8 9 1 1 Fiber Optic Patch Cords Multimode With LX.5® Small-Form-Factor
|
Original
|
PDF
|
FOA-INLX03
FOA-INLX05
FOA-INLX07
FOA-INLX10
FOA-INLX12
FOA-INLX15
FOA-INLX20
FOA-INALX03
FOA-INALX05
FOA-INALX07
E2000 advantages
fl1a
|
2013 - Not Available
Abstract: No abstract text available
Text: : Black Cable impact resistance, maximum: 5.88 N-m 12-fiber conduit and cable weight: 68.2448 kg/km , Count 02 = 2- fiber 04 = 4- fiber 08 = 8- fiber 12 = 12-fiber 8 â Length Blank = Length , Opti-Core® Dielectric Conduited Fiber Cable S P E C I F I C AT I O N S H E E T technical information Opti-Core® Dielectric Conduited Fiber (DCF) Cable is an integral part of the Panduit end-to-end fiber optic solution, designed to support today's data needs while meeting tomorrow's ever-advancing
|
Original
|
PDF
|
FBSP57--WW-ENG
|
2008 - FIBER PATCH CORD
Abstract: buffer 245 102117AE 311M
Text: ProAx® Fiber Connector Series ProAx® Quad Fiber (F4) Connectors Overview Broadcast and Entertainment Products ADC's ProAx® Quad Fiber (F4) connector is quickly becoming the industry-standard harsh , reduced bend radius fiber cable, a factory termination connector that can be assembled at the customer , ) 16 AWG Stranded Steel OD (mm) Type Quad Fiber Manufacturer F9A ADC F4CBL-F9A-BK N/A N/A 9.2 Quad Fiber F12A ADC F4CBL-F12A-BK N/A N/A 12 Cable reference
|
Original
|
PDF
|
IP-68
F4CBL-F12A-BK
EIA-FOTP-41A
EIA-FOTP-25B
EIA-FOTP-104A
EIA-FOTP-33A
102117AE
EIA-FOTP-37A
FIBER PATCH CORD
buffer 245
102117AE
311M
|
2013 - Not Available
Abstract: No abstract text available
Text: MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP , RRP131324UPNM8S025F_NAFTA_AEN Page 3 | Revision date 2013-03-02 MDU, RPDpass® Riser, Pull-Down, SM ZBL (2) 12-fiber MTP , (2) 12-fiber MTP® (non-pinned) to (3) 8- fiber MTP (non-pinned), 24 Fiber , 25 ft Fiber
|
Original
|
PDF
|
12-fiber
RRP131324UPNM8S025F
RRP131324UPNM8S025F
|
raychem catalog termination kit and splicing kit
Abstract: FLUKE 79 3 series DALLAS 2501 220V AC 12V DC regulated switching raychem JOINT procedure KIT BR 8050 D raychem high voltage cable termination kit FLUKE 79 manual APC back UPS RS 800 oz 8602 gn
Text: Weeks 4 Weeks NEW 2 YOU PRE-OWNED EQUIPMENT PROGRAM Fiber Instrument Sales, Inc. can save you money , Customer with Electronic and Hard Copies RS232 to USB Converter CERTIFY FIBER OPTIC INSTALLATIONS - , certification documents. TEST FIBER TO THE HOME - The tri-wavelength model, which can test at 1490 nm, can be used to troubleshoot and test your Fiber to the Home (FTTH) applications. OPTIMIZE QUICK-TERMINATION , press the Scan button on the OTDR. Slowly insert the fiber into the connector. The scan of the field
|
Original
|
PDF
|
MT9083A
18AWG
S-RG59ZIP500B
S-RG591KB
S-RG595000B
S-RG59ZIP1KB
RG59/U
75ohm
raychem catalog termination kit and splicing kit
FLUKE 79 3 series
DALLAS 2501
220V AC 12V DC regulated switching
raychem JOINT procedure KIT
BR 8050 D
raychem high voltage cable termination kit
FLUKE 79 manual
APC back UPS RS 800
oz 8602 gn
|
omron c200
Abstract: No abstract text available
Text: Fiber Sensors Best Selection Catalog OMRON's Fiber Sensors continue to support an increasing range of applications. This catalog brings you the latest information on our Fiber Units. E32-series Fiber Units Amplifier Units E3X-DA-S/-MDA Series E3X-NA Series Standard Models First, Our , sleeves). Models with sleeves Flexible, Pliable Fiber That Can Be Handled Like Wire We have developed a broad range of fibers to meet a wide variety of needs. Multicore (flexible) fiber is a new type
|
Original
|
PDF
|
E32-series
omron247
E353-E1-03
omron c200
|
lc om3
Abstract: 10GIGTM
Text: Part Number TM Part Description LC to LC simplex 12-fiber 10Gig TM 50/125µm OM3 Multimode Plenum Rated Trunk Cable Assembly with pulling eye on one end. LC to LC simplex 12-fiber 10Gig TM 50/125µm OM3 Multimode Plenum Rated Trunk Cable Assembly with pulling eye on one end. LC to LC simplex 12-fiber 10Gig TM , FSP52411F100A Part Description LC to LC simplex 12-fiber 50/125µm OM2 multimode plenum rated trunk cable assembly with pulling eye on one end. LC to LC simplex 12-fiber 50/125µm OM2 multimode plenum rated trunk
|
Original
|
PDF
|
TIA/EIA-568-B
TIA/EIA-568-C
UL1666
10Gig
FSP54811F200A
FSP91211F100A
FSP91211F150A
FSP91211F200A
FSP92411F100A
FSP92411F150A
lc om3
10GIGTM
|