The Datasheet Archive

Top Results (6)

Part ECAD Model Manufacturer Description Datasheet Download Buy Part
APXW005 APXW005 ECAD Model ABB Critical Power ProLynx DC-DC Converter, Input Range: 12 or 24V (9-36Vin), Vout: 3 - 18 V (programmable), Iout: 2.5 - 5.0A, Efficiency: 96%
APXW003 APXW003 ECAD Model ABB Critical Power ProLynx DC-DC Converter, Input Range: 12 or 24V (9-36Vin), Vout: 3 - 18 V (programmable), Iout: 1.5 - 3.0A, Efficiency: 97%
AXB070X43 AXB070X43 ECAD Model ABB Critical Power Austin Lynx 24V:Non-isolated Power Module
AXB050X43-SRZ AXB050X43-SRZ ECAD Model ABB Critical Power Austin Lynx 24V:Non-isolated Power Module
AXB050X43-SR AXB050X43-SR ECAD Model ABB Critical Power Austin Lynx 24V:Non-isolated Power Module
AXB030X43-SR AXB030X43-SR ECAD Model ABB Critical Power Austin Lynx 24V:Non-isolated Power Module

12/24 v dc-dc converter schematic Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
2001 - K2202

Abstract: 82724a 82721K
Text: insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Output 3 Uo nom [ V ] 3.3 3.3 3.3 5 5 5 12 12 12 15 15 15 +5 +5 +5 +12 +12 +12 +15 +15 +15 +5 +5 +5 +5 , +1800 +1800 +1800 +1400 +1400 +1400 +4000 +4000 +4000 +3500 +3500 +3500 Uo nom [ V ] ­5 ­5 ­5 ­12 ­12


Original
PDF 25-Series K2202 82724a 82721K
2000 - auo 002

Abstract: No abstract text available
Text: DC-DC converter output circuit SELV circuit Earthed SELV circuit Mains Basic 250 V AC Earthed SELV , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Type Survey and Key Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [A] 3.3 3.3 3.3 5 5 5 12 12 , IMR 40 Series Output 2 Uo nom Io nom [ V ] [A] ­5 ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 +12 +12 +12 +12 +12 , Output 3 Uo nom Io nom [ V ] [A] ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5


Original
PDF 40-Series auo 002
2002 - auo 002

Abstract: No abstract text available
Text: circuit 2 Operational insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Type Survey and Key Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [A] 3.3 3.3 3.3 5 5 5 12 12


Original
PDF 40-Series auo 002
2001 - MTBF SIEMENS

Abstract: 400512
Text: DC-DC converter output circuit SELV circuit Earthed SELV circuit Mains Basic 250 V AC Earthed SELV , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Output 3 Uo nom [ V ] 3.3 3.3 3.3 5 5 5 12 12 12 15 15 15 24 24 24 +5 +5 +5 +12 +12 +12 +15 +15 +15 +5 , +6 +6 +6 +6 +6 +6 +6 Uo nom [ V ] ­5 ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 +12 +12 +12 +12 +12 +15 +15 +15 , Uo nom [ V ] ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 Io nom [A] ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5 ­0.5


Original
PDF 40-Series MTBF SIEMENS 400512
2000 - Not Available

Abstract: No abstract text available
Text: converter Mains Basic ≤250 V AC Result Minimum required safety status of the front end output , the DC-DC converter output circuit ≤60 V Minimum required grade of isolation, to be , Operational insulation, provided by the DC-DC converter >60 V Double or reinforced Hazardous voltage , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL’s purpose, the fuse , -Series Input voltage range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test


Original
PDF 40-Series
2002 - Battery charger 24 volt

Abstract: auo 002
Text: to the input of the converter . Table 4: Input filter components Input voltage 12, 24, 48 V DC C1 4.7 , Operational insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input


Original
PDF 40-Series Battery charger 24 volt auo 002
2000 - auo 15"

Abstract: auo 002 82721K
Text: insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Type Survey and Key Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [mA] 3.3 3.3 3.3 5 5 5 12 12 , +3500 +3500 Output 2 Uo nom Io nom [ V ] [mA] ­5 ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 +12 +12 +12 +15 +15 +15


Original
PDF 25-Series auo 15" auo 002 82721K
1999 - melcher dc imr

Abstract: auo 002 MTBF SIEMENS
Text: insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , to output electric strength test 1500 V DC Single, dual or triple output · Input voltage range 2 :1 · , nom [ V ] [A] 3.3 3.3 3.3 5 5 5 12 12 12 15 15 15 24 24 24 +5 +5 +5 +12 +12 +12 +15 +15 +15 +5 +5 +5 +5 +5 +5 +5 +5 1 DC-DC Converters <40 Watt Benign Environment Output 2 Uo nom Io nom [ V ] [A


Original
PDF 40-Series melcher dc imr auo 002 MTBF SIEMENS
1999 - melcher k 4000 converter

Abstract: auo 002
Text: insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , to output electric strength test 1500 V DC Single, dual or triple output · Input voltage range 2 :1 · , [ V ] [mA] 3.3 3.3 3.3 5 5 5 12 12 12 15 15 15 +5 +5 +5 +12 +12 +12 +15 +15 +15 +5 +5 +5 +5 +5 +5 6500 , +1400 +4000 +4000 +4000 +3500 +3500 +3500 Output 2 Uo nom Io nom [ V ] [mA] ­5 ­5 ­5 ­12 ­12 ­12 ­15 ­15


Original
PDF 25-Series melcher k 4000 converter auo 002
2002 - 8 pin diagram 25032

Abstract: No abstract text available
Text: the input of the converter . Table 4: Input filter components Input voltage 12 V DC 24 V DC 48 V DC 1 , output circuit 2 Functional insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V , non-earthed input conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). , output voltage to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be , range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage IMR


Original
PDF 25-Series 8 pin diagram 25032
melcher am 3000 converter

Abstract: 40family
Text: of the converter . Table 4: Input filter com ponents Iripüt ÿôliàiÉjô 12, 24, 48 V DC Fig. 4 Input , converter Earthed output circuit2 >60 V Double or reinforced <60 V >60 V Hazardous voltage secondary , output electric strength test 1500 V DC Single, dual or triple output IMR 40-Family 2 .7 6 " , Type Key and Product Marking Type Key 24 IMR 40 - 12 12 -2 Nominal input voltage in v o lt , for output 1 in v o lt . 05.24 Nominal output voltage for output 2 in v o lt


OCR Scan
PDF IMR40-Fomily 40-Family 97/IN melcher am 3000 converter 40family
melcher dc imr

Abstract: No abstract text available
Text: the input of the converter . Table 4: Input filter com ponents Input voltage 12 V DC 24 V DC 48 V DC , input of the DC-DC converter (see fig. Schematic safety concept). For UL's purpose, the fuse needs to be , output electric strength test 1500 V DC Single, dual or triple output IMR 25 , Converters <40 W Benign Environment 24 IMR 25 - 12 12 -2 Nominal input voltage in v o lt , output 1 in v o lt. 05. 15 Nominal output voltage for output 2 in v o lt


OCR Scan
PDF 25-FomHy 25-Family 97/IN melcher dc imr
2001 - DC-DC Converters 5 imp 6-1515

Abstract: No abstract text available
Text: 60 V Minimum required safety status of the front end output circuit DC-DC converter Measures to , able to limit the output voltage to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety , end Battery DC-DC converter 10004 Suppressor diode SELV + ~ ­ Fig. 5 Schematic , up to 72 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input voltage 5 V ±10% · Input filter built-in · Short-circuit proof · No derating · Low cost IMP 6


Original
PDF
2001 - TICOMEL

Abstract: No abstract text available
Text: converter Earthed output circuit 2 >60 V Double or reinforced 60 V >60 V Hazardous voltage secondary , range up to 72 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , 5 5 12 12 6 6 12 12 6 6 12 12 5 5 6 6 12 12 6 6 12 12 Input voltage U i min.U i max [ V DC] 10.36 , Type designation Option U o nom [ V ] 3.3 3.3 3.3 3.3 5 5 5 5 12 12 12 12 15 15 15 15 +5 +5 +12 +12 , 400 800 800 500 500 250 250 500 500 200 200 400 400 U o nom [ V ] ­5 ­5 ­12 ­12 ­12 ­12 ­15 ­15 ­15


Original
PDF
1999 - MELCHER THE POWER PARTNERS 24 imp 6-05-7

Abstract: MELCHER 24 IMP 6-05-7
Text: , provided by the DC-DC converter Earthed output circuit 2 fuse 3 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , Input to output electric strength test 1500 V DC Single or dual output · Input voltage 5 V ±10% · Input , Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [mA] 5 5 5 12 12 12 15 15 15 +5 +5 +5 +12 +12 , Output 2 Uo nom Io nom [ V ] [mA] ­5 ­5 ­5 ­12 ­12 ­12 ­15 ­15 ­15 ­500 ­500 ­500 ­250 ­250 ­250 ­200 ­200


Original
PDF
2000 - Siemens B

Abstract: battery charger schematic Ticomel auo 002
Text: circuit 2 Operational insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , range up to 72 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input , Survey and Key Data Table 1: Type survey Output 1 U o nom I o nom [ V ] [mA] 3.3 3.3 3.3 3.3 5 5 5 5 12


Original
PDF
2001 - Not Available

Abstract: No abstract text available
Text: circuit 2 Operational insulation, provided by the DC-DC converter Earthed output circuit 2 fuse 3 >60 V , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , up to 72 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input voltage 5 V ±10% · Input filter built-in · High efficiency up to 81% · Short-circuit proof · No derating ·


Original
PDF
2000 - Not Available

Abstract: No abstract text available
Text: , provided by the DC-DC converter Earthed output circuit 2 fuse 3 >60 V Double or reinforced 60 V >60 V , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , up to 72 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage · Input voltage 5 V ±10% · Input filter built-in · High efficiency up to 81% · Short-circuit proof · No derating · , . Type Survey and Key Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [mA] 5 5 5 12 12 12 15 15 15


Original
PDF
2001 - BW 6122

Abstract: No abstract text available
Text: converter . C1 C2 L1 Ci Vi­ 07028 Vi+ Fig. 3 Input filter arrangement for 12, 24 and 40 V DC types , Operational insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , up to 72 V DC 1 output up to 30 V DC 500 V DC I/O electric strengh test voltage · Input voltage range


Original
PDF
1999 - Melcher converter s 1000

Abstract: MELCHER THE POWER PARTNERS Battery charger 48 volt circuit diagram TICOMEL
Text: : Technical Information: Safety. DC-DC converter Maximum DC output voltage from the front end 1 60 V Minimum , non-earthed input conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). , voltage to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be , to output electric strength test 1500 V DC Single or dual output · Input voltage range up to 4:1 · , 1: Type survey Output 1 U o nom I o nom [ V ] [mA] 3.3 3.3 5 5 12 12 15 15 +5 +5 +12 +12 +15 +15 1500


Original
PDF
2000 - Not Available

Abstract: No abstract text available
Text: safety status of the output circuit Safety status of the DC-DC converter output circuit ≤60 V , Input voltage range up to 5.5 V DC 1 or 2 outputs up to 30 V DC 1500 V DC I/O electric strength test voltage • Input voltage 5 V DC ±10% • High efficiency up to 58% • Short-circuit proof • No , , e.g. telephone systems components, industrial controllers and small appliances from a 5 V DC voltage , Survey and Key Data Table 1: Type survey Output 1 Uo nom Io nom [ V ] [mA] 5 200 Output 2 Uo


Original
PDF
2000 - A2202-N1

Abstract: No abstract text available
Text: Single output converter block diagram Attention: Ci = 4.7 µF/100 V must be added in any application. Co , non-earthed input conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). , voltage to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be , up to 72 V DC 1 output up to 30 V DC 500 V DC I/O electric strengh test voltage · Input voltage range , Table 1: Type survey Output Uo nom Io nom [ V ] [mA] 3.3 5 12 15 ±5 ±12 ±15 1 2 Output power


Original
PDF
2000 - 03035

Abstract: BW 6122
Text: converter . C1 C2 L1 Ci Vi­ 07028 Vi+ Fig. 3 Input filter arrangement for 12, 24 and 40 V DC types , DC-DC converter output circuit SELV circuit Earthed SELV circuit Mains Basic 250 V AC Earthed SELV , up to 72 V DC 1 output up to 30 V DC 500 V DC I/O electric strengh test voltage · Input voltage range , Survey and Key Data Table 1: Type survey Output Uo nom Io nom [ V ] [mA] 3.3 5 12 15 ±5 ±12 ±15 1500 1000 , 68 67 70 70 Input voltage range Ui min.Ui max Ui min.Ui max 18.36 V DC 20.60 V DC 24 IMR


Original
PDF
2001 - BW 6122

Abstract: 48 volt Battery charger circuit
Text: Operational insulation, provided by the DC-DC converter Earthed output circuit 2 >60 V Double or reinforced , conductor directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL , to SELV (<60 V ) until the input fuse blows (see fig.: Schematic safety concept). Has to be insulated , up to 72 V DC 1 output up to 30 V DC 500 V DC I/O electric strengh test voltage · Input voltage range , Table 1: Type survey Output Uo nom Io nom [ V ] [mA] 3.3 5 12 15 ±5 ±12 ±15 1500 1000 500 400 ±500 ±250


Original
PDF
1999 - BW 6122

Abstract: melcher dc imr Melcher Melcher M 1000 Melcher AM 1000 Melcher converter s 1000 MELCHER THE POWER PARTNERS power supply 1000 watt
Text: converter Mains Basic 250 V AC Result Minimum required safety status of the front end output , the DC-DC converter output circuit 60 V Minimum required grade of isolation, to be provided , Operational insulation, provided by the DC-DC converter >60 V Double or reinforced Hazardous voltage , the input of the DC-DC converter (see fig.: Schematic safety concept). For UL's purpose, the fuse , connection + DC-DC converter Suppressor diode SELV ­ Earth connection Fig. 6 Schematic


Original
PDF
Supplyframe Tracking Pixel