The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
LM134H-6 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LM134H-3 Linear Technology Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, ROUND, THROUGH HOLE MOUNT, METAL CAN, TO-46, 3 PIN
LTC2997IDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C
LTC2997CDCB#PBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: 0°C to 70°C
LTC2997HDCB#PBF-ES Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature: High
LTC2997IDCB#TRMPBF Linear Technology LTC2997 - Remote/Internal Temperature Sensor; Package: DFN; Pins: 6; Temperature Range: -40°C to 85°C

11730A power sensor cable Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
Digital Panel Meter PM 128

Abstract: Digital Panel Meter PM 129 8484a 8900C E4416A 8481D 11730A power sensor cable 11730A E4418B E4418A
Text: E9326A The E9320 power sensors must be used with an E9288A, B or C sensor cable and only operate with , Supplies rear-panel sensor input ( power reference calibrator is on rear panel) Opt 004 Deletes the 11730A , 003 Moves Reference Oscillator from Front to Rear Panel Opt 004 Deletes the 11730A Power Sensor , Power Meter C-Size VXI Opt 004 Delete Sensor Cable Opt 915 Service Support Kit Opt 916 Additional , Product Note, Choosing the Right Power Meter and Sensor , p/n 5968-7150E Ordering Information E4416A


Original
PDF 01SEC027 E4416A E9320 RS-232/422 E4417A E932X UG-599/U Digital Panel Meter PM 128 Digital Panel Meter PM 129 8484a 8900C 8481D 11730A power sensor cable 11730A E4418B E4418A
2012 - Not Available

Abstract: No abstract text available
Text: sensor cables 11730A Power sensor cable : 1.5 m/5 ft 11730B Power sensor cable : 3.0 m/10 ft 11730C Power sensor cable : 6.1 m/20 ft 11730D Power sensor cable : 15.2 m/50 ft 11730E Power sensor cable : 30.5 m/100 ft Other accessories 34131A Transit case 34141A Soft , front and one rear USB port, VGA Power cord N191xA-106 Power sensor cable , 1.5 m (5 ft) (One , to +44 dBm (100 pW to 25 W, depending on the attached power sensor ) • Measurement speed: Up to


Original
PDF N1913A N1914A E4418B/19B 5990-4019EN
2014 - Not Available

Abstract: No abstract text available
Text: sensor Power sensor cable , 1.5 m (5 ft) (One per N1913A, two per N1914A) N1913/ 4A-C02 Front , service plan for N1913A/N1914A 3 months for standard-shipped accessories Power sensor cables 11730A Power sensor cable : 1.5 m/5 ft 11730B Power sensor cable : 3.0 m/10 ft 11730C Power sensor cable : 6.1 m/20 ft 11730D Power sensor cable : 15.2 m/50 ft 11730E Power sensor cable : 30.5 m , €“70 dBm to +44 dBm (100 pW to 25 W, depending on the attached power sensor ) • Measurement speed


Original
PDF N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN
2014 - Not Available

Abstract: No abstract text available
Text: sensor cables 11730A Power sensor cable : 1.5 m/5 ft 11730B Power sensor cable : 3.0 m/10 ft 11730C Power sensor cable : 6.1 m/20 ft 11730D Power sensor cable : 15.2 m/50 ft 11730E Power sensor cable : 30.5 m/100 ft Other accessories 34131A Transit case 34141A Soft , cord N1913/ 4A-C01 Front calibrator, front sensor Power sensor cable , 1.5 m (5 ft) (One per , €“70 dBm to +44 dBm (100 pW to 25 W, depending on the attached power sensor ) • Measurement speed


Original
PDF N1913A N1914A E4418B/19B BP-3-1-13) 5990-4019EN
2014 - Not Available

Abstract: No abstract text available
Text: be configured for the measurement 11730A Power sensor cable Require 3 to connect each of , . Figure 1. A demonstration of power accuracy; power sensor measurement vs. N5247A PNA-X R1 receiver < 0.1 , Thermocouple power sensor Required to calibrate power over the 10 MHz to 50 GHz band 11921F 1.0 mm (f , 50 GHz to 75 GHz V-band power sensor Required to calibrate power over the 50 GHz to 75 GHz band , W8486A 75 GHz to 110 GHz W-band power sensor Required to calibrate power over the 75 GHz to 110


Original
PDF N5251A N5227A N5261A N5262A BP-01-15-14) 5989-7620EN
2014 - 11730A power sensor cable

Abstract: N1913A/201 11730A B908 Applications
Text: —¦ Power sensor cable (1.5 meter (5 ft) 11730A ), one per N1913A and two per N1914A ◦ Power cord (plug , software • Supplied accessories: ◦ Power sensor cable (1.5 meter (5 ft) E9288A), one per E4416A and , Delete power sensor cable N1913/ 4A-101 Single/dual-channel average power meter N1913/ 4A-201 , ◦ 10 meters (31 ft) E9288C • 11730A -F power sensor cables (refer to the compatibility section , €¢ E441xA CW power sensors (10 MHz to 26.5 GHz, sensor dependent) • E9300 average power sensors (9 kHz


Original
PDF 5965-6382E) E9320 5980-1469E) N1913A N1914A BP-01-15-14) 5990-4173EN 11730A power sensor cable N1913A/201 11730A B908 Applications
1998 - 11730A

Abstract: HP8481H 8481B 8481H apc-7 connector 11730B japanese diode manual HPE1416A 8485A E1416A
Text: Ordering Information Description Power Meter C-size VXI Delete Cable Additional Service Manual Additional User Manual 3 Yr. Retn. to HP to 1 Yr. OnSite Warr. 5-ft (1.5 m) Power Sensor Cable 10-ft (3.0 m) Power Sensor Cable 20-ft (6.1 m) Power Sensor Cable 50-ft (15.2 m) Power Sensor Cable 100-ft (30.5 m) Power Sensor Cable 200-ft (61.0 m) Power Sensor Cable High-power Thermocouple Power Sensor , : Power reference: 100 kHz to 50 GHz, 75 GHz to 110 GHz sensor dependent ­70 to + 44 dBm (100 pW to


Original
PDF E1416A E1416A 8482B 8482B 8481H 8481H 8482H 8482H 11730A HP8481H 8481B apc-7 connector 11730B japanese diode manual HPE1416A 8485A
2001 - 437B

Abstract: No abstract text available
Text: 1 Yr. OnSite Warr. 5-ft (1.5 m) Power Sensor Cable 10-ft (3.0 m) Power Sensor Cable 20-ft (6.1 m) Power Sensor Cable 50-ft (15.2 m) Power Sensor Cable 100-ft (30.5 m) Power Sensor Cable 200-ft (61.0 m) Power Sensor Cable High-power Thermocouple Power Sensor Mil Std 45662A Calibration , representation of measured RMS power for rectangular pulses Sensor tables: Allows entry and storage of up , . General Frequency: Power range: 100 kHz to 110 GHz sensor dependent –70 to + 44 dBm (100 pW to 25


Original
PDF E1416A E1416A 5564E 437B
2014 - Not Available

Abstract: No abstract text available
Text: separately. 11730A : 5-foot (1.5 m) power sensor and SNS noise source cable (included as a default option with every SNS) 11730B: 10-foot (3.0m) power sensor and SNS noise source cable 11730C: 20-foot (6.1m) power sensor and SNS noise source cable A good quality adaptor must be used to connect the SNS Series , requires a compatible cable and adaptor to enable their use. The 11730A is selected as a default option , accurately and reliably. This noise source comes with an APC 3.5 (m) connector. 3 Accurate noise power


Original
PDF N4000A, N4001A, N4002A N4000A N4001A cal48 BP-09-27-13) 5988-0081EN
2002 - ISO calibration certificate formats

Abstract: E441xA-A6J 11730B IEC-625 e9288A E9300 E9322A E9323A E9325A E9326A
Text: and E9300 power sensors: 11730A Power sensor and SNS noise source cable , length 5 ft (1.5 m , ) approximate 8.0 kg (17.6 lbs) approximate Ordering information Accessories supplied Power sensor cable , Programming Guide) Power sensor cables E441xA-004 Delete power sensor cable For operation with the E9320 power sensors: Power sensor cable , length 5 ft (1.5 m) Power sensor cable , length 10 ft (3 m) Power sensor cable , length 31 ft (10 m) E9288A E9288B E9288C E4417A Note: The E9288A, B, and C


Original
PDF E4416A/E4417A E9320 5980-1469E ISO calibration certificate formats E441xA-A6J 11730B IEC-625 e9288A E9300 E9322A E9323A E9325A E9326A
2008 - ISO calibration certificate formats

Abstract: E4417A E441xA-908 ieee-488 gpib 5965-6630E 8251 programming application e9288A R-50C-001 IEC-625 E9321A
Text: information Accessories supplied Power sensor cable E9288A 1.5 meter (5 ft). One per E4416A, two per , English Programming Guide) Power sensor cables E441xA-004 Delete power sensor cable For operation with the E9320 power sensors: E9288A Power sensor cable , length 5 ft (1.5 m) E9288B Power sensor cable , length 10 ft (3 m) E9288C Power sensor cable , length 31 ft (10 m) Note: The E9288A, B , sensor and SNS noise source cable , length 5 ft (1.5 m) 11730B Power sensor and SNS noise source cable


Original
PDF E4416A/E4417A E9320 125/minute 14/minute 5980-1469E ISO calibration certificate formats E4417A E441xA-908 ieee-488 gpib 5965-6630E 8251 programming application e9288A R-50C-001 IEC-625 E9321A
2009 - Not Available

Abstract: No abstract text available
Text: sensors: 11730A Power sensor and SNS noise source cable , length 5 ft (1.5 m) 11730B Power sensor and , sensor cable E9288A 1.5 meter (5 ft). One per E4416A, two Power sensor cables per E4417A Power , -1-1994 certificate of calibration supplied as standard. E441xA-004 Delete power sensor cable For operation with the E9320 power sensors: E9288A Power sensor cable , length 5 ft (1.5 m) E9288B Power sensor cable , length 10 ft (3 m) E9288C Power sensor cable , length 31 ft (10 m) Note: The E9288A, B, and C


Original
PDF E4416A/E4417A E9320 E9320 E9300 N8480 5980-1469E
2002 - 8485A

Abstract: e4412a service manual 8481A E4418B E4413A e4412a Diode Datasheet 1N4007 11730A 8482B R8486A
Text: 72/23/EEC Accessories supplied Power sensor cable 11730A : E4418B has one 1.5 meter (5 ft) sensor cable . E4419B has two 1.5 meter (5 ft) sensor cables. Power cord: One 2.4 meter (7.5 ft) cable , all ranges. Cables Option E441xB-004: Delete power sensor cable Additional cables 11730A : Power sensor and SNS noise source cable , length 1.5 meters (5 ft) 11730B: Power sensor and SNS noise source cable , length 3 meters (10 ft) 11730C: Power sensor and SNS noise source cable , length 6.1


Original
PDF E4418B E4419B 5965-6382E 8485A e4412a service manual 8481A E4413A e4412a Diode Datasheet 1N4007 11730A 8482B R8486A
2002 - 5952-8255

Abstract: N4001A 11730A Agilent 8710-1764 11730A power sensor cable 5988-0081EN R-50C-001 11730B N4000A NFA 16
Text: cables are also available as separate items. 11730A : 5-foot (1.5 m) power sensor and SNS noise source cable (supplied with NFA) 11730B: 10-foot (3.0m) power sensor and SNS noise source cable 11730C: 20-foot (6.1m) power sensor and SNS noise source cable A good quality adaptor must be used to connect the SNS , Accurate noise power The output of a noise source, usually given in terms of Excess Noise Ratio (ENR , source. The reflections cause uncertainty in the noise power emerging from the source. The measured


Original
PDF N4000A, N4001A, N4002A N4000A N4001A 5988-0081EN 5952-8255 N4001A 11730A Agilent 8710-1764 11730A power sensor cable 5988-0081EN R-50C-001 11730B N4000A NFA 16
2009 - Not Available

Abstract: No abstract text available
Text: -004: Delete power sensor cable from standard inclusion with power meter 11730A : Power sensor and SNS noise source cable , length 1.5 meters (5 ft) 11730B: Power sensor and SNS noise source cable , length 3 meters (10 ft) 11730C: Power sensor and SNS noise source cable , length 6.1 meters (20 ft) 11730D: Power , meter Standard-shipped accessories Power sensor cable : E4418B has one 1.5-meter (5-ft) sensor cable . E4419B has two 1.5-meter (5-ft) sensor cables. Power cord: One 2.4-meter (7.5-ft) cable . Power plug


Original
PDF E4418B/E4419B E4418B/9B cdma2000Â 480A/B/H, 5965-6382E
2009 - E4418B

Abstract: E4419 E4419B V8486A E4412A E441xB-915 700PW E4413A ISO calibration certificate formats W8486A
Text: . Service options Cables Warranty and Calibration3 Option E441xB-004: Delete power sensor cable from standard inclusion with power meter 11730A : Power sensor and SNS noise source cable , length 1.5 meters (5 ft) 11730B: Power sensor and SNS noise source cable , length 3 meters (10 ft) 11730C: Power sensor and SNS noise source cable , length 6.1 meters (20 ft) 11730D: Power sensor cable , length 15.2 meters (50 ft) 11730E: Power sensor cable , length 30.5 meters (100 ft) 11730F: Power sensor cable


Original
PDF E4418B/E4419B E4418B/9B cdma2000® 480A/B/H, N8480A/B/H, R/Q8486A, N8486AR/AQ 5965-6382E E4418B E4419 E4419B V8486A E4412A E441xB-915 700PW E4413A ISO calibration certificate formats W8486A
2009 - N8481A

Abstract: N1917C Diode Sensors N8480 W8486A n8487A E4410 E9301B agilent CFT 455 n-type connector male
Text: dynamic range, the N8480 Series offers you the widest thermocouple sensor power range in the industry , in two groups: 2 The power meter and sensor meet its specifications when: · Stored for a , at least 30 minutes. · The power meter and power sensor are within their recommended calibration , CFT. Frequency and Dynamic Power Range Sensor Option Sensor Model Frequency Range , Damage Level Sensor Model Damage Level (Average Power ) Damage Level (Peak Power ) +25 dBm 15


Original
PDF N8480 N1911A/12A) E4416A/17A) N1913A/14A, E4418B/19B) 5989-9333EN N8481A N1917C Diode Sensors W8486A n8487A E4410 E9301B agilent CFT 455 n-type connector male
2012 - Not Available

Abstract: No abstract text available
Text: CFT is not available for the N8488A power sensor . Accurate, repeatable measurements Here’s how , thermocouple sensor power range in the industry. System integration can be difficult, but not with the , power meter and power sensor meet their specifications when: Characteristic information is , operating temperature range and turned on for at least 30 minutes • The power meter and power sensor , N8480 Series sensors except Option CFT. Frequency and dynamic power range Sensor option Sensor


Original
PDF N8480 N8488A) N1911A/12A) E4416A/17A) N1913A/14A, E4418B/19B) N8488A 5989-9333EN
2009 - 11708a

Abstract: N1913A E9300B N191xA-908 Diode Sensors 11730A W8486A u2000 N8481A N8481
Text: -109 N1913A-200 N1914A-200 Power sensor cables Warranty: 11730A 11730D Other accessories , noise: Frequency range: For example: Power range: Single sensor dynamic range: 1 mW Power , range Sensor dynamic range N1913A/14A EPM Series power meters performance characteristics , (Options): Sensor cal tables: Line power Limits: Preset default values: Input voltage range , Documentation 9 E-Series power sensor specifications E-Series CW power sensor specifications Widest


Original
PDF N1913A N1914A N1914A N1913A/14A CDMA2000 11a/b/g 5990-4019EN 11708a E9300B N191xA-908 Diode Sensors 11730A W8486A u2000 N8481A N8481
AD0912UB-A7

Abstract: AD0812HB-C71GP AD2512HB-BV7 AD4512LX-D03 AB7505HX-HB3 AD0812XB-D91GP AD0612XB AD0812HB ad6505 AD0912
Text: VOLTAGE RANGE START-UP VOLTAGE RATED CURRENT RATED POWER RATED SPEED AIR FLOW STATIC AIR PRESSURE NOISE , 'ON '. 4 - 5 Input Power : Input Power shall be measured after 3 minutes of continuous rotation at , . 5.4 Avoid the damage, check the correct voltage and proper polarity before connecting with power . 5.5


OCR Scan
PDF AD0912UB-A73GL 49/22i AD0912UB-A7 AD0812HB-C71GP AD2512HB-BV7 AD4512LX-D03 AB7505HX-HB3 AD0812XB-D91GP AD0612XB AD0812HB ad6505 AD0912
6Bs smd transistor

Abstract: e 156176 smd code 6Bs HDC-HE-16SS crimp tools kit 163356 163063 RSV 1.6 ZE 36 6BS SMD pcb connectors 163953
Text: easy-to-use latch larger cable space knock-resistant coating Quality to ISO 9001 The cost-effective , . Qty. HDC-DW-MOD 168820 1 For removal of ConCept modules from insert holders. Cable glands, Brass IP 54 with gripping jaw Cable glands, plastic IP 68 L L PG PG L1 L1 , 29-K68 PG 29 VG 36-K68 PG 36 VG 42-K68 PG 42 VG 48-K68 PG 48 all sizes in mm Cable glands , VG 36-Exe SW VG 42-Exe SW VG 48-Exe SW all sizes in mm Cable glands, metal Type KV 11


Original
PDF 24/RS DC-200 6Bs smd transistor e 156176 smd code 6Bs HDC-HE-16SS crimp tools kit 163356 163063 RSV 1.6 ZE 36 6BS SMD pcb connectors 163953
2013 - Not Available

Abstract: No abstract text available
Text: No file text available


Original
PDF 1000uF 7343H)
RG2012P-472-B-T5

Abstract: RG2012P-681-B-T5 rg2012p RG2012P-105-B-T5 RG2012P-22 RG2012P-242-B-T5 RG2012P-243-B-T5
Text: No file text available


Original
PDF RG2012PB-KIT RG2012PB RG2012P-101-B-T5 RG2012P-102-B-T5 RG2012P-103-B-T5 RG2012P-104-B-T5 RG2012P-105-B-T5 RG2012P-111-B-T5 RG2012P-112-B-T5 RG2012P-113-B-T5 RG2012P-472-B-T5 RG2012P-681-B-T5 rg2012p RG2012P-105-B-T5 RG2012P-22 RG2012P-242-B-T5 RG2012P-243-B-T5
2011 - ta035tcm105

Abstract: TA006TCM226 TA010TCM475 TA020TCM475 TA025TCM TA025TCM106
Text: No file text available


Original
PDF TA050TCM225 TA050TCM335 TA050TCM475 TA050TCM685 TA050TCM106 TA050TCM156 TA050TCM226 ta035tcm105 TA006TCM226 TA010TCM475 TA020TCM475 TA025TCM TA025TCM106
2008 - Not Available

Abstract: No abstract text available
Text: No file text available


Original
PDF
Supplyframe Tracking Pixel