The Datasheet Archive

Top Results (6)

Part Manufacturer Description Datasheet Download Buy Part
JRCW450U641-TZ ABB Critical Power JRW450U Orca Series; DC-DC Converter Power Module
KHHD002A5B41Z ABB Critical Power KHHD002A5B Hammerhead Series; DC-DC Converter Power Module
JRCW450U641-18Z ABB Critical Power JRW450U Orca Series; DC-DC Converter Power Module
JRCW450U64-35Z ABB Critical Power JRW450U Orca Series; DC-DC Converter Power Module
JRCW450U64-18Z ABB Critical Power JRW450U Orca Series; DC-DC Converter Power Module
JRCW450U641Z ABB Critical Power JRW450U Orca Series; DC-DC Converter Power Module

"Current to Voltage Converter" 4-20ma using LM358 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
voltage to 4-20mA 24v loop converter

Abstract: 17800 Voltage to Current Converter circuit 4-20mA
Text: 3 4 5 6 VOLTAGE CONVERTER SG9 CURRENT TO VOLTAGE CONVERTER +5V 1 TB1 1 + -V is not connected to meter ground on `-I' suffix models. 2 ­ TB2 1 2 4-20mA CURRENT LOOP POWER + ­ +V ­V POWER SUPPLY INPUT Figure 1. DMS-40PC-4/ 20S , maximum loop voltage drop is specified with a 20.0mA input current . +21.6 to +26.4Vdc at 60mA max , full-scale output of 19.4 to 20.4mA. When using transmitters whose outputs fall outside these ranges, try


Original
PDF DMS-40PC-4/20S 4-20mA DMS-40PC-4/20S 12Vdc 24Vdc DS-0402B voltage to 4-20mA 24v loop converter 17800 Voltage to Current Converter circuit 4-20mA
2008 - sg97

Abstract: No abstract text available
Text: REFERENCE CIRCUIT ON S1 1 2 3 4 5 6 S2 1 2 3 4 5 6 VOLTAGE CONVERTER 1 ON +5V SG9 +5V CURRENT TO VOLTAGE CONVERTER TB1 1 2 TB2 1 2 -V is not connected to meter ground on `-I' suffix models. + ­ + +V ­ ­V 4-20mA CURRENT LOOP POWER POWER SUPPLY INPUT Figure 1. DMS , , vibration-resistant, six-position DIP switches. To further enhance reliability, both power supply and current loop , . Current Loop Input Full Scale Input Range (1) Loop Burden (2) Voltage Drop (2) Overcurrent Protection


Original
PDF DMS-40PC-4/20S 4-20mA 32Vdc 20-turn, DMS-40PC-4/20S 0-1999bed DMS-40PC-420 sg97
2012 - PS-112

Abstract: No abstract text available
Text: CIRCUIT ON S1 1 2 3 4 5 6 S2 1 2 3 4 5 6 ON +5V VOLTAGE CONVERTER SG9 +5V CURRENT TO VOLTAGE CONVERTER TB1 1 2 TB2 1 2 -V is not connected to meter ground on `-I' suffix models. + ­ + +V ­ ­V For full details go to www.murata-ps.com/rohs 4-20mA CURRENT LOOP POWER POWER , switches. To further enhance reliability, both power supply and current loop connections are made via , transmitters having a low-level output of 3.7 to 4.3mA and a full-scale output of 19.4 to 20.4mA. When using


Original
PDF DMS-40PC-4/20S 4-20mA 32Vdc 20-turn, DMS-40PC-4/20S DMS-40PC-420 PS-112
2008 - "Current to Voltage Converter" 4-20ma

Abstract: isolated 4 to 20ma analog transmitter circuit Led digital panel meters schematic diagrams 4-20ma scheme 17800 4 digit up counter diagram Voltage to Current Converter circuit 4-20mA
Text: VOLTAGE CONVERTER SG9 +5V CURRENT TO VOLTAGE CONVERTER 1 TB1 -V is not connected to meter ground on `-I' suffix models. 1 + 2 ­ 1 2 + ­ +V 4-20mA CURRENT LOOP , setting #20 enabled. The maximum loop voltage drop is specified with a 20.0mA input current . (3 , configured for range #20 with 4mA adjusted ( using R3) to read "0000" ±1 count, and 20mA adjusted ( using R7 , that an offset voltage is applied to the A/D's LO input. This offset voltage is used to null the


Original
PDF DMS-40PC-4/20S 4-20mA DMS-40PC-4/20S 12Vdc 24Vdc DMS-40PC-420 "Current to Voltage Converter" 4-20ma isolated 4 to 20ma analog transmitter circuit Led digital panel meters schematic diagrams 4-20ma scheme 17800 4 digit up counter diagram Voltage to Current Converter circuit 4-20mA
2008 - "Current to Voltage Converter" 4-20ma

Abstract: DMS-20 24V 4.....20MA How to convert 4-20 ma two wire transmitter led display schematic transducer 4-20ma weight transducer 4-20ma DMS-20-CP DMS-20PC
Text: ­5V DC/DC CONVERTER TB1 + CURRENT TO VOLTAGE CONVERTER + ­ ­ LOOP INPUT , circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current range. Listed , close. Connections to the current loop are made via a reliable, two-position, screw-type terminal , 4mA input can be typically adjusted ( using R3, Zero/ Offset Adjust) to display any positive reading


Original
PDF DMS-20PC-4/20 4-20mA 20-turn DMS20pc-420 "Current to Voltage Converter" 4-20ma DMS-20 24V 4.....20MA How to convert 4-20 ma two wire transmitter led display schematic transducer 4-20ma weight transducer 4-20ma DMS-20-CP DMS-20PC
2008 - 4 digit lcd 4-20mA input

Abstract: DMS-20-CP DMS-20PC How to convert 4-20 ma two wire transmitter
Text: +5V 2 3 4 5 6 ­5V DC/DC CONVERTER TB1 + CURRENT TO VOLTAGE CONVERTER + ­ ­ LOOP INPUT For full details go to www.murata-ps.com/rohs www.murata-ps.com , the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current range. Listed impedance , close. Connections to the current loop are made via a reliable, two-position, screw-type terminal


Original
PDF DMS-20PC-4/20 4-20mA 20-turn, DMS20pc-420 4 digit lcd 4-20mA input DMS-20-CP DMS-20PC How to convert 4-20 ma two wire transmitter
2015 - Not Available

Abstract: No abstract text available
Text: /DC CONVERTER TB1 + – CURRENT TO VOLTAGE CONVERTER + For full details go to , -4/20 loop-powered meters employ active circuitry to convert the loop current into a voltage , the , . Additionally, the total maximum loop voltage drop is only 5V! Users no longer have to settle for , competitive meters, there are no jumpers or solder gaps to open or close. Connections to the current loop , the full 4- to -20mA current range. Listed impedance specification applies at 20mA. 2. 000 to


Original
PDF DMS-20PC-4/20 4-20mA 20-turn, DMS20PC-4/20
2009 - DMS-20-CP

Abstract: DMS-20PC "Current to Voltage Converter"
Text: TB1 + ­ CURRENT TO VOLTAGE CONVERTER + For full details go to www.murata-ps.com/rohs ­ , loop-powered meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to , voltage drop is only 5V! Users no longer have to settle for difficult-to-read LCD displays in , no jumpers or solder gaps to open or close. Connections to the current loop are made via a reliable


Original
PDF DMS-20PC-4/20 4-20mA 20-turn, DMS20pc-420 DMS-20-CP DMS-20PC "Current to Voltage Converter"
2009 - How to convert 4-20 ma two wire transmitter

Abstract: weight transducer 4-20ma DMS-20-CP DMS-20LCD digits lcd display
Text: CURRENT TO VOLTAGE CONVERTER For full details go to www.murata-ps.com/rohs + 2 ­ LOOP , loop-powered meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to , of different input-current/ output-reading combinations. And, connections to the current loop are , turns, and place SW1-SW6 to OFF. Voltage Drop ­ 1.8 2.0 Volts 2. Select DIP switch


Original
PDF DMS-20LCD-4/20 4-20mA 20-turn DMS20LCD-420 How to convert 4-20 ma two wire transmitter weight transducer 4-20ma DMS-20-CP DMS-20LCD digits lcd display
load sell transducer 4-20ma

Abstract: "Current to Voltage Converter" 4-20ma DIP SWITCH DMS 233 Isolated 4-20ma 0 to 300 volt digital meter data diagram transducer 4-20ma weight transducer 4-20ma weight transmitter diagram DMS-20-CP
Text: 4 5 6 ­5V DC/DC CONVERTER TB1 + ­ CURRENT TO VOLTAGE CONVERTER + Figure 1 , meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current , . Connections to the current loop are made via a reliable, two-position, screw-type terminal block. The DMS , , a 4mA input can be typically adjusted ( using R3, Zero/Offset Adjust) to display any positive


Original
PDF DMS-20PC-4/20 4-20mA load sell transducer 4-20ma "Current to Voltage Converter" 4-20ma DIP SWITCH DMS 233 Isolated 4-20ma 0 to 300 volt digital meter data diagram transducer 4-20ma weight transducer 4-20ma weight transmitter diagram DMS-20-CP
2011 - 4 to 20mA transmitter schematic

Abstract: DMS-20-CP DMS-20PC
Text: TB1 + ­ CURRENT TO VOLTAGE CONVERTER + For full details go to www.murata-ps.com/rohs ­ , loop-powered meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to , voltage drop is only 5V! Users no longer have to settle for difficult-to-read LCD displays in , no jumpers or solder gaps to open or close. Connections to the current loop are made via a reliable


Original
PDF DMS-20PC-4/20 4-20mA 20-turn, DMS20PC-4/20 4 to 20mA transmitter schematic DMS-20-CP DMS-20PC
4 digit lcd 4-20mA input

Abstract: weight transducer 4-20ma DMS-30-CP
Text: digit, LCD-display process monitor available. 4 T 2 3 4 5 6 2 3 4 5 6 DC/DC CONVERTER CURRENT TO VOLTAGE CONVERTER 100 « 4-20 mA Current Loop Input Figure 1. DMS-40LCD-4/20S Simplified Schematic , connections to the current loop are made via a reliable, screw-type terminal block. To further enhance , 19.4 to 20.4mA. When using a transmitter whose output falls outside these ranges and the desired , specified with the meter configured for range #20 with a 4mA input adjusted ( using R3) to read "0000" Â


OCR Scan
PDF DMS-40LCD-4/20S 4-20mA 190-0hm 20-turn DMS-40LCD-4/20S 190-0higny 4 digit lcd 4-20mA input weight transducer 4-20ma DMS-30-CP
2008 - "Current to Voltage Converter" 4-20ma

Abstract: precision 4-20ma current source weight transducer 4-20ma Voltage to Current Converter 4-20mA DIP SWITCH transducer 4-20ma schematic diagram lcd monitor How to convert 4-20 ma two wire transmitter Voltage to Current Converter circuit 4-20mA using 4.5 digit lcd display
Text: 2 3 4 5 6 ­5V DC/DC CONVERTER TB1 1 CURRENT TO VOLTAGE CONVERTER For full details go to www.murata-ps.com/rohs + 2 ­ LOOP INPUT www.murata-ps.com , combinations. And, connections to the current loop are made via a reliable, two-position, screw-type terminal , . Because DATEL's DMS-4/20 loop-powered meters employ active circuitry to convert the loop current into a , constant over the full 4- to -20mA current range. Listed impedance specification applies at 20mA


Original
PDF DMS-20LCD-4/20 4-20mA DMS20LCD-420 "Current to Voltage Converter" 4-20ma precision 4-20ma current source weight transducer 4-20ma Voltage to Current Converter 4-20mA DIP SWITCH transducer 4-20ma schematic diagram lcd monitor How to convert 4-20 ma two wire transmitter Voltage to Current Converter circuit 4-20mA using 4.5 digit lcd display
2009 - DMS-20PC

Abstract: weight transducer 4-20ma DMS-20-CP
Text: CIRCUIT ON DIP SWITCHES 1 +5V 2 3 4 5 6 ­5V DC/DC CONVERTER TB1 + CURRENT TO VOLTAGE CONVERTER + ­ ­ LOOP INPUT For full details go to www.murata-ps.com , loop-powered meters employ active circuitry to convert the loop current into a voltage , the meters' effective , voltage drop is only 5V! Users no longer have to settle for difficult-to-read LCD displays in , no jumpers or solder gaps to open or close. Connections to the current loop are made via a reliable


Original
PDF DMS-20PC-4/20 4-20mA 20-turn, DMS20pc-420 DMS-20PC weight transducer 4-20ma DMS-20-CP
Not Available

Abstract: No abstract text available
Text: 1 2 3 4 5 6 1 2 3 4 6 5 SG9 +5V CURRENT TO VOLTAGE CONVERTER TB1 + + ­ ­ TB2 *U2 is used on ­24RL model only 1 + 2 ­ 4-20mA CURRENT LOOP INPUT 1 2 + ­ +v ­v POWER SUPPLY INPUT Figure 1. DMS-40PC-4/20S Simplified , temperature due to the fact that an offset voltage is applied to the A/D's LO input. This offset voltage is used to null the voltage developed with a 4ma input. To function properly, the autozeroing feature


Original
PDF DMS-40PC-4/20S 4-20mA DMS-40PC-4/20S 12Vdc 24Vdc DS-0402A
voltage to 4-20mA 24v loop converter

Abstract: No abstract text available
Text: 1 2 3 4 5 6 1 2 3 4 6 5 SG9 +5V CURRENT TO VOLTAGE CONVERTER TB1 + + ­ ­ TB2 *U2 is used on ­24RL model only 1 + 2 ­ 4-20mA CURRENT LOOP INPUT 1 2 + ­ +v ­v POWER SUPPLY INPUT Figure 1. DMS-40PC-4/20S Simplified , . To further enhance reliability, both power supply and current loop connections are made via reliable , ( using R3) to read "0000" ±1 count, and 20mA adjusted ( using R7) to read "19000" ±2 counts


Original
PDF DMS-40PC-4/20S 4-20mA DMS-40PC-4/20S 12Vdc 24Vdc DS-0402A voltage to 4-20mA 24v loop converter
Digital Panel Meter up 413

Abstract: lcd voltmeters oms 450 DMS-20LCD DMS-20PC DMS-20-CP DMS-30-CP DMS-30PC DMS-20 DMS-20PC-1
Text: ESFTF m DC/DC CONVERTER a CURRENT TO VOLTAGE CONVERTER Figure 1. DMS-20PC-4/20S Simplified , range. Additionally, the total maximum loop voltage drop is only 5V! Users no longer have to settle for , competitive meters, there are no jumpers or solder gaps to open or close. Connections to the current loop are , . All operating power is derived directly from the loop current itself—no external power supply is , versatility practically eliminates the need to order more costly, long-lead-time, factory customized


OCR Scan
PDF DMS-20PC-4/20S 4-20mA 20-turn, DMS-20PC-4/20S Digital Panel Meter up 413 lcd voltmeters oms 450 DMS-20LCD DMS-20PC DMS-20-CP DMS-30-CP DMS-30PC DMS-20 DMS-20PC-1
DMS-20-CP

Abstract: DMS-20LCD 4 to 20mA transmitter schematic
Text: +5V 2 3 4 5 6 ­5V DC/DC CONVERTER TB1 1 CURRENT TO VOLTAGE CONVERTER , of different input-current/output-reading combinations. And, connections to the current loop are , ) Because DATEL's DMS-4/20 loop-powered meters employ active circuitry to convert the loop current into a , constant over the full 4- to -20mA current range. Listed impedance specification applies at 20mA. 1 , source is required! The simple 2-wire hookup allows the DMS-20LCD-4/20 Series to be connected anywhere


Original
PDF DMS-20LCD-4/20 4-20mA 20-turn DS-0400A DMS-20-CP DMS-20LCD 4 to 20mA transmitter schematic
2006 - "Current to Voltage Converter" 4-20ma

Abstract: 4 to 20mA transmitter schematic transducer 4-20ma weight transducer 4-20ma How to convert 4-20 ma two wire transmitter DIP SWITCH DMS-20LCD-4 lcd monitor display block diagram power DMS 233 weight transmitter diagram
Text: ­5V DC/DC CONVERTER TB1 1 CURRENT TO VOLTAGE CONVERTER + Figure 1. DMS-20LCD-4/20 , circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current range. Listed , / output-reading combinations. And, connections to the current loop are made via a reliable, two-position , three columns, a 4mA input can be typically adjusted ( using R3, Zero/Offset Adjust) to display any


Original
PDF DMS-20LCD-4/20 4-20mA 20-turn DMS20LCD-4/20 "Current to Voltage Converter" 4-20ma 4 to 20mA transmitter schematic transducer 4-20ma weight transducer 4-20ma How to convert 4-20 ma two wire transmitter DIP SWITCH DMS-20LCD-4 lcd monitor display block diagram power DMS 233 weight transmitter diagram
weight transducer 4-20ma

Abstract: DMS-20-CP DMS-20PC
Text: 4 5 6 ­5V DC/DC CONVERTER TB1 + ­ CURRENT TO VOLTAGE CONVERTER + Figure 1 , . Connections to the current loop are made via a reliable, two-position, screw-type terminal block. The DMS , ) Because DATEL's DMS-4/20 loop-powered meters employ active circuitry to convert the loop current into a , constant over the full 4- to -20mA current range. Listed impedance specification applies at 20mA. 1 , ( using R3, Zero/Offset Adjust) to display any positive reading between "000" and "800". The


Original
PDF DMS-20PC-4/20 4-20mA weight transducer 4-20ma DMS-20-CP DMS-20PC
DMS-20-CP

Abstract: DMS-20PC
Text: 4 5 6 ­5V DC/DC CONVERTER TB1 + ­ CURRENT TO VOLTAGE CONVERTER + Figure 1 , meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current , . Connections to the current loop are made via a reliable, two-position, screw-type terminal block. The DMS , , a 4mA input can be typically adjusted ( using R3, Zero/Offset Adjust) to display any positive


Original
PDF DMS-20PC-4/20 4-20mA DMS-20-CP DMS-20PC
0353D

Abstract: DMS-20-CP DMS-20PC
Text: 4 5 6 ­5V DC/DC CONVERTER TB1 + ­ CURRENT TO VOLTAGE CONVERTER + Figure 1 , meters employ active circuitry to convert the loop current into a voltage , the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4- to -20mA current , . Connections to the current loop are made via a reliable, two-position, screw-type terminal block. The DMS , , a 4mA input can be typically adjusted ( using R3, Zero/Offset Adjust) to display any positive


Original
PDF DMS-20PC-4/20 4-20mA DS-0353D 0353D DMS-20-CP DMS-20PC
Digital Panel Meter up 413

Abstract: lcd voltmeters oms 450 DMS-20LCD DMS-20PC DMS-20-CP DMS-30-CP DMS-20 200mV 12pin lcd meter DMS-20PC-1
Text: "1 CURRENT TO VOLTAGE CONVERTER LOOP INPUT Figure 1. DMS-20PC-4/20S Simplified Schematic DATEL , close. Connections to the current loop are made via a reliable, two-position, screw-type terminal block , Off 4. 000 to 300-500 Off Off On 5. 000 to 200-300 On On On © The DMS-20PC-4/20S, using any , , easy-to-read, bright red, LED display. All operating power is derived directly from the loop current , over the entire 4-20mA operating range. Additionally, the total maximum loop voltage drop is only 5V


OCR Scan
PDF DMS-20PC-4/20S 4-20mA 20-turn, DMS-20PC-4/20S Digital Panel Meter up 413 lcd voltmeters oms 450 DMS-20LCD DMS-20PC DMS-20-CP DMS-30-CP DMS-20 200mV 12pin lcd meter DMS-20PC-1
DMS-30-CP

Abstract: AY 3 8600
Text: 3 4 6 5 ­5V TB1 DC/DC CONVERTER CURRENT TO VOLTAGE CONVERTER + ­ 1 2 + ­ 4-20mA Current Loop Input Figure 1. DMS-40LCD-4/20S Simplified Schematic DATEL , , six-position DIP switches. The two connections to the current loop are made via a reliable, screw-type , temperature because an offset voltage is applied to the A/D's LO input. This offset is used to null the signal voltage developed with a 4ma input. In order for the A/D to display a steady "0000" ±1 digit, the


Original
PDF DMS-40LCD-4/20S 190-Ohm 20-turn DMS-40LCD-4/20S 190-Ohm 4-20mAata DS-0401 DMS-30-CP AY 3 8600
2008 - "Current to Voltage Converter" 4-20ma

Abstract: weight transducer 4-20ma DMS-30-CP 420S
Text: ­5V TB1 DC/DC CONVERTER + CURRENT TO VOLTAGE CONVERTER 1 Figure 1. DMS-40LCD-4/20S Simplified Schematic www.murata-ps.com 2 + For full details go to www.murata-ps.com/rohs , , six-position DIP switches. The two connections to the current loop are made via a reliable, screw-type , having a low-level output of 3.8 to 4.3mA and a full-scale output of 19.4 to 20.4mA. When using a , adjusted ( using R3) to read "0000" ±1 count, and a 20mA input adjusted ( using R7) to read "19000" ±2


Original
PDF DMS-40LCD-4/20S 190-Ohm 4-20mA DMS401LCD-420S "Current to Voltage Converter" 4-20ma weight transducer 4-20ma DMS-30-CP 420S
Supplyframe Tracking Pixel