500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
XDS510 Texas Instruments XDS510 Class Emulators visit Texas Instruments
XDS560 Texas Instruments XDS560 Class High Speed Emulators visit Texas Instruments
ISL99201IRTDZ-TK Intersil Corporation Filterless High Efficiency 1.5W Class D Mono Amplifier; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL99201IRTAZ-T Intersil Corporation Filterless High Efficiency 1.5W Class D Mono Amplifier; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL99201IRTBZ-T Intersil Corporation Filterless High Efficiency 1.5W Class D Mono Amplifier; DFN8; Temp Range: -40° to 85°C visit Intersil Buy
ISL99201IRTAZ-TK Intersil Corporation Filterless High Efficiency 1.5W Class D Mono Amplifier; DFN8; Temp Range: -40° to 85°C visit Intersil Buy

ul 506 class 130

Catalog Datasheet MFG & Type PDF Document Tags

en 50022

Abstract: iec 61558 Teil 2-2; 2-4; 2-6, UL 506 *Kombifußplatte für Schraub- und Tragschienenmontage nach DIN 50022 , ; 2-6, DIN EN 61558-2-2: 2-4; 2-6, VDE 0570 Part 2-2; 2-4; 2-6, UL 506 *Dual purpose foot plate for , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 , cooling 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130
-
Original

ul 506 class 130

Abstract: Isolating Transformer 130 isolating transformer to IEC 61558-2-2; 2-4, DIN EN 61558-2-2; 2-4, VDE 0570 part 2-2; 2-4; 2-6, UL 506 , 300 VA 130 VA C-UL-US, ENEC 10 (VDE) IP 00 I by self-cooling 40 °C VDE=B, UL=105 min. 2500 V , Seite 1 ST 130/69/23* Errors and omissions excepted. Please note that product illustrations do , 130/69/23* Control-, safety isolating- and isolating transformer Errors and omissions excepted , voltage (ca. x factor) Efficiency Power VDE (DB cos phi=1) Power VDE (KB cos phi=0.5) Power UL
BLOCK Transformatoren-Elektronik
Original
Abstract: manufactured to comply with UL Standard 506,1561,1012, or 1062 and carry the applicable UL Listing Label , 506 XPTQ E 79947V1 50B8 B 3223 130 .0 5 0 -5 .0 N /A Air Cooled Ventilated & , Certified LOAD VOLTAGE How to overcurrent protect (OCP) 600 volt class transform ers and associated , Phase KVA Three Phase G e n e ra l P u rp o s e a n d B u c k -B o o s t 506 XPTQ E 79 9 4 7 V 1 50B8 B 3223 130 .0 5 0 -.1 5 0 N /A General Purpose Buck-Boost & DIT -
OCR Scan
ST-201992 R1978

Transformer Ip 100

Abstract: PHI05 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 Primärseitig ±15 V , 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±15 V primary tappings for the adaption of the , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 , 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130
-
Original
Transformer Ip 100 PHI05 Class 130 Class 130(B) transformer 4500v 175 va transformer

Class 130(B) transformer

Abstract: transformer 50 Hz . Trenntransformator nach IEC 61558-2-2; 2-4; 2 6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 , 61558-2-2, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±5 % primary tappings for the , 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 3600 V, 50 Hz 4500 V, 50 Hz 4500 V, 50 Hz 3600 V , °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130
-
Original
transformer 50 Hz VDE 0570 transformer 230 V 50 Hz ste 2500 6,3x0,8 A 7800

BV 048-5052.0 H

Abstract: ee20 transformer bobbin / 8.88 230 2. UL 1585, File E175197 6 / 13.30 230 1. UL 506, File E113449 Secondary (V , . UL 506, File E113449 Secondary (V / mA) 230 AGENCY APPROVALS Pin Ø 0,6 mm (Pin DIA , TRANSFORMERS Type EE20 / 10 - 0.50VA Primary (V) 1. UL 506, File E113449 Secondary (V / mA) 230 , . UL 1585, File E175197 6 / 83 230 1. UL 506, File E113449 Secondary (V / mA) 230 , Class 2/3 V DE Part Number 230 3. EN61558 8.50 9 / 111 230 2. UL 1585, File
Pulse Engineering
Original
BV 048-5052.0 H ee20 transformer bobbin WT 5072 EI type bobbin transformer UI30 030-7274.0 LT2007 08VA-0 15D-71083
Abstract: n UL 506, File E73539 UL Recognized Class B UL 1446, File E80130 CSA 22.2#66, File LR68051-2 n TUV, EN61558 Figure A VA 25 43 80 130 175 VA 25 43 80 130 175 Figure B WT , 1.625 FIG A A B B B UL Class B, CSA, and TUV certified Part No. Chassis Mount A41 , -43-230A43 A41-80-230A44 A41-130-230A45 A41-175-230A46 (Size) VA 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 80 130 175 25 43 Pulse Specialty Components
Original
A41-25-10A1 A41-43-10A2 A41-80-10A3 A41-130-10A4 A41-175-10A5 A41-25-12A7

DST4-36B26

Abstract: , 506, File E73539 n UL Recognized Class B n UL 1446, File E179499 n CSA 22.2#66, File LR68051-2 n , -10B33 LP230-25B21 LP230-50B22 AGENCY APPROVALS n UL, 506, File E73539 n UL 1446, File E179499 n CSA , Transformers Low Frequency, Open-Style Laminated, Chassis-Tran Series AGENCY APPROVALS n UL, 506, File E73539 n UL 1446, File E179499 n CSA 22.2#66, File LR68051-2 n UL Recognized Class B Channel frame , Laminated, International High Power Series AGENCY APPROVALS n UL, 506, File E73539 n UL Recognized
Pulse Electronics
Original
DST4-36B26 LT2012 ST7-28B56 ST7-36B57 ST7-48B58 ST7-56B59 D-71083

1750VA

Abstract: isolating transformer to IEC 61558-2-2; 2-4, DIN EN 61558-2-2; 2-4, VDE 0570 part 2-2; 2-4; 2-6, UL 506 , 10900 VA 1750 VA C-UL-US, ENEC 10 (VDE) IP 00 I by self-cooling 40 °C VDE=B, UL=130 min. 2500 V , voltage (ca. x factor) Efficiency Power VDE (DB cos phi=1) Power VDE (KB cos phi=0.5) Power UL Standards and security Approvals Protection index Safety class (prepared) Cooling method Ambient temperature max. Class of Insulation System Test voltage Mechanical data Type Terminals Fixing method
BLOCK Transformatoren-Elektronik
Original
1750VA
Abstract: isolating transformer to IEC 61558-2-2; 2-4, DIN EN 61558-2-2; 2-4, VDE 0570 part 2-2; 2-4; 2-6, UL 506 , 12400 VA 2180 VA C-UL-US, ENEC 10 (VDE) IP 00 I by self-cooling 40 °C VDE=B, UL=130 min. 2500 V , voltage (ca. x factor) Efficiency Power VDE (DB cos phi=1) Power VDE (KB cos phi=0.5) Power UL Standards and security Approvals Protection index Safety class (prepared) Cooling method Ambient temperature max. Class of Insulation System Test voltage Mechanical data Type Terminals Fixing method BLOCK Transformatoren-Elektronik
Original
Abstract: isolating transformer to IEC 61558-2-2; 2-4, DIN EN 61558-2-2; 2-4, VDE 0570 part 2-2; 2-4; 2-6, UL 506 , voltage (ca. x factor) Efficiency Power VDE (DB cos phi=1) Power VDE (KB cos phi=0.5) Power UL Standards and security Approvals Protection index Safety class (prepared) Cooling method Ambient temperature max. Class of Insulation System Test voltage Mechanical data Type Terminals Fixing method , 110 VA 63 VA C-UL-US, ENEC 10 (VDE) IP 00 I by self-cooling 40 °C VDE=B, UL=105 min. 2500 V BLOCK Transformatoren-Elektronik
Original
Abstract: isolating transformer to IEC 61558-2-2; 2-4, DIN EN 61558-2-2; 2-4, VDE 0570 part 2-2; 2-4; 2-6, UL 506 , 4400 VA 1400 VA C-UL-US, ENEC 10 (VDE) IP 00 I by self-cooling 40 °C VDE=B, UL=130 min. 2500 V , voltage (ca. x factor) Efficiency Power VDE (DB cos phi=1) Power VDE (KB cos phi=0.5) Power UL Standards and security Approvals Protection index Safety class (prepared) Cooling method Ambient temperature max. Class of Insulation System Test voltage Mechanical data Type Terminals Fixing method BLOCK Transformatoren-Elektronik
Original

A0100

Abstract: Drop Operating Temperature Range Ambient Temperature Range EN132400 300 VRMS 130 VRMS 3000 VDC for 2s 5000 volts , assembly and crimping up to 80% and installation. The products meet all applicable requirements of UL and EN. Patents Pending PRODUCT SPECIFICATIONS Electrical Current Rating UL 1977, UL1283 , Force Contact Retention UL 1977 Materials Insulator & Cable Clamp Contacts & Ground Plate Capacitor PBT
Anderson Power Products
Original
A0100 3-5846S1 3-5846S2 AFC065-PC/4AWG AFC065-PC/6AWG AFC065-PC/M25 AFC065-PC/M16

7168-m

Abstract: ] 7,8 max. 600V ( UL ) Betriebsbedingungen / Operating conditions Umgebungstemperatur Ambient temperature Temperaturklasse VDE Class ISO °C VDE [ °C ] -10.+40 F Temperaturklasse UL Class ISO °C UL Class 130 Kühlungsart Type of cooling Luftgeschwindigkeit Wind speed , / Signs VDE 0570 / EN 61 558 Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506
BLOCK Transformatoren-Elektronik
Original
7168-m M165-35S

M165-35S

Abstract: 690V ] 26,2 max. 600V ( UL ) Betriebsbedingungen / Operating conditions Umgebungstemperatur Ambient temperature Temperaturklasse VDE Class ISO °C VDE [ °C ] -10.+40 F Temperaturklasse UL Class ISO °C UL Class 130 Kühlungsart Type of cooling Luftgeschwindigkeit Wind speed , / Signs VDE 0570 / EN 61 558 Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506
BLOCK Transformatoren-Elektronik
Original
690V

7168-m

Abstract: M165-35S ] 10,9 max. 600V ( UL ) Betriebsbedingungen / Operating conditions Umgebungstemperatur Ambient temperature Temperaturklasse VDE Class ISO °C VDE [ °C ] -10.+40 F Temperaturklasse UL Class ISO °C UL Class 130 Kühlungsart Type of cooling Luftgeschwindigkeit Wind speed , / Signs VDE 0570 / EN 61 558 Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506
BLOCK Transformatoren-Elektronik
Original

7168-m

Abstract: M165-35S . 600V ( UL ) Betriebsbedingungen / Operating conditions Umgebungstemperatur Ambient temperature Temperaturklasse VDE Class ISO °C VDE [ °C ] -10.+40 B Temperaturklasse UL Class ISO °C UL Class 130 Kühlungsart Type of cooling Luftgeschwindigkeit Wind speed Betriebsart , 0570 / EN 61 558 Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506 ; CSA 22.2
BLOCK Transformatoren-Elektronik
Original
din 7168 41308 class 8 date sheet air core reactor

M165-35S

Abstract: 7168-m ] 4,4 max. 600V ( UL ) Betriebsbedingungen / Operating conditions Umgebungstemperatur Ambient temperature Temperaturklasse VDE Class ISO °C VDE [ °C ] -10.+40 F Temperaturklasse UL Class ISO °C UL Class 130 Kühlungsart Type of cooling Luftgeschwindigkeit Wind speed , / Signs VDE 0570 / EN 61 558 Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506
BLOCK Transformatoren-Elektronik
Original

Class 130(B) transformer

Abstract: Class 130 nach IEC 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 Teil 2-2; 2-4; 2-6, UL 506 , 61558-2-2; 2-4; 2-6, DIN EN 61558-2-2; 2-4; 2-6, VDE 0570 part 2-2; 2-4; 2-6, UL 506 ±15 V primary , 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 VDE=B, UL=130 4500 V, 50 Hz 4500 V, 50 Hz , Selbstkühlung self cooling 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C VDE=B, UL=130
-
Original
transformer 230 V 50 Hz 70 V clamp current transformer 61558 630VA TS-35 ul 506 class 130

M165-35S

Abstract: 7168-m Class ISO °C VDE [ °C ] -10.+40 B Temperaturklasse UL Class ISO °C UL Class 130 , Teil 1 VDE 0570 / EN 61 558 Teil 20 cUL approbiert / approved ( UL 506 ; CSA 22.2 ) Weitere , ] 3-8 Prüfspannung Test voltage [ m ] [ kV ] 84 max. 600V ( UL ) 4
BLOCK Transformatoren-Elektronik
Original
Showing first 20 results.