500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LM3445-REF Texas Instruments 230 Vac Off-line Triac Dimmer Retrofit with 6 LEDs Reference Design visit Texas Instruments
PMP8014 Texas Instruments Triac dimmable Flyback LED Driver with PFC for A19 using TPS92314 visit Texas Instruments
PMP8012 Texas Instruments TPS92310 - 220VAC, 8W Isolated , Triac dimmable visit Texas Instruments
PMP6003 Texas Instruments TRIAC Dimmable 230V LED Lighting Driver Controller (32V@350mA) visit Texas Instruments
PMP6002 Texas Instruments TRIAC Dimmable 120V LED Lighting Driver Controller (32V@350mA) visit Texas Instruments
LM3497MM/NOPB Texas Instruments LM3497 Triac Dimmable Offline LED Driver 10-MSOP visit Texas Instruments Buy

triac with snubber

Catalog Datasheet MFG & Type PDF Document Tags

MDA920A4

Abstract: full wave controlled rectifier using RC triggering circuit heaters. With an ac voltage applied to the circuit, the gated thyristor (SCR, TRIAC, etc.) remains in its , logic circuits and microprocessors to easily control ac power with TRIAC drivers of both the , control applications. PHASE CONTROL WITH THYRISTORS The most common method of electronic ac power control , accomplishing phase control is shown in Figure 6.2. The electronic switch in this case is a triac (Q) which can be turned on by a small current pulse to its gate. The TRIAC turns off automatically when the current
Motorola
Original

BTB15-600B

Abstract: triac snubber calculation and the turn on dI/dt below 20 A/µs. Fig. 6: Triac turn on with snubber circuit. IT R C dIT , SNUBBERLESS triac with VDRM = 600 V and IGT = 50 mA; specifiedat 9 A/ms without snubber. (*) 15 Amps , driving an inductive load, triacs are designed with RC snubber. These commutation aid networks are badly , of application circuit with triac. LOAD MAINS INTRODUCTION: The triac is today the only , designed with a networkmade of a resistor R and a capacitorC, the SNUBBER circuit. This circuit improves
STMicroelectronics
Original

triac RC snubber

Abstract: z0103 equivalent AN437 Application note RC snubber circuit design for TRIACs Introduction When a TRIAC controls , reapplied voltage and ensure right TRIAC turn-off, designer usually used a snubber circuit connected in parallel with the TRIAC. This circuit can also be used to improve TRIAC immunity to fast transient , 1.1.2 Snubber circuit benefit at TRIAC turn-off . . . . . . . . . . . . . . . . . . . . . . . . . 3 , AN437 1 Snubber circuit functions and drawback 1.1 Turn-off improvement 1.1.1 TRIAC
STMicroelectronics
Original
triac RC snubber z0103 equivalent triac snubber RC snubber thyristor design RC snubber circuit triac with snubber

BTB15-600B

Abstract: triac snubber calculation and the turn on dI/dt below 20 A/µs. Fig. 6: Triac turn on with snubber circuit. IT R C dIT , SNUBBERLESS triac with VDRM = 600 V and IGT = 50 mA; specified at 9 A/ms without snubber. (*) 15 Amps , driving an inductive load, triacs are designed with RC snubber. These commutation aid networks are badly , of application circuit with triac. LOAD MAINS INTRODUCTION: The triac is today the only , designed with a network made of a resistor R and a capacitor C, the SNUBBER circuit. This circuit
STMicroelectronics
Original
BTB15-600B triac snubber calculation TRIAC application note AN vdrm rc snubber calculation TRIAC RCA TRIAC BTB15 600

Optocoupler MOC 3020

Abstract: optotriac moc3021 the load. w0 + Snubber With No C + + 2 E The voltage wave across the TRIAC has an , TRIAC and an inductor in series with the line. SNUBBER INDUCTOR D1 D2 120 VAC OR 240 VAC , highest possible temperature using thyristors with the lowest measured trigger current. TRIAC , voltage and dt snubber discharge current increase. The voltage wave has a 1-COS () shape with overshoot , Non-inductive Snubber Resistor for Four Quadrant Triggering. TRIAC Type Non-Sensitive Gate (IGT 10 mA
Motorola
Original
Optocoupler MOC 3020 optotriac moc3021 MOC3011 optocoupler motorola 5A optocoupler MOC ic moc 3021 triac MAC 120 G AN1048 MOC3011 MOC3021 EB-101 AN982

ic moc 3021

Abstract: transistor W2W requires the addition of a RC snubber across the TRIAC and an inductor in series with the line. THYRISTOR , series with the snubber capacitor reduces dI. It should not be more than five percent of the load dt , series with the snubber capacitor. It can be small because it does not need to carry the load current , current diverts through the snubber resistor causing a spike of theoretically infinite dV with magnitude , at the snubber natural frequency. They appear as a resistance in series with the load inductance and
ON Semiconductor
Original
transistor W2W RC snubber for 3 phase rectifier bridge 2N390 TRANSISTOR T50 thyristor MAC15 triac thyristor firing method for soft start AN1048/D

MAC15 triac

Abstract: "OPTIMUM SNUBBERS FOR POWER SEMICONDUCTORS" when the snubber resistor is small. C and L are related to one another by 02. dV scales linearly with , 10 µs Table 1. Minimum Non-inductive Snubber Resistor for Four Quadrant Triggering. TRIAC dI , Transient maximum allowed current. Inductance in series with the snubber capacitor reduces dI. It , sometimes serve this purpose. Alternatively, a separate inductor can be added in series with the snubber , rise at 800 V with the non­inductive resistor. The Snubber Capacitor A damping factor of 0.3
ON Semiconductor
Original
moc 3021 scr ldc 2000 rev.01 Snubber circuits theory, design and application U MOC3011 soft start MOC 3021 free

RC snubber ac motor

Abstract: HY 400 the addition of a RC snubber across the TRIAC and an inductor in series with the line. vent , . Minimum Non-inductive Snubber Resistor for Four Quadrant Triggering. TRIAC dI can be improved by , . Inductance in series with the snubber capacitor reduces dI. It should not be more than five percent of the , inductor can be added in series with the snubber capacitor. It can be small because it does not need to , voltage across the snubber capacitor. The resistor R1 supplies the trigger current of the power TRIAC. A
ON Semiconductor
Original
RC snubber ac motor HY 400 BTA08-8003W3G moc opto triac Why R-C Networks And Which One For Your Converter 2n6073 sum

RC snubber scr design inductive load

Abstract: triac RC snubber Figure 7. Simplifies TRIAC Circuit With Snubber This equation is derived from the governing , leads its current). This presents a unique problem with TRIAC circuits, in that there is a limitation , ." Figure 9 demonstrates the dampening effect of introducing a snubber circuit at the output of the TRIAC , Rsnb AC Line ZC - Csnb Trigger - Inductive Load with snubber Figure 9. Inductive Load With Snubber www.vishay.com 4 Vishay Semiconductors Instead of resorting to a snubber and
Vishay Semiconductors
Original
RC snubber scr design inductive load Gate turn off triac Triac load inductive RC inductive load thyristor design triac snubber design TRIAC inductive VO425X VO415X EN610004-4 IL420 IL410 IL421X

TRIAC inductive

Abstract: RC snubber dv/dt diode Figure 7. Simplifies TRIAC Circuit With Snubber This equation is derived from the governing , leads its current). This presents a unique problem with TRIAC circuits, in that there is a limitation , ." Figure 9 demonstrates the dampening effect of introducing a snubber circuit at the output of the TRIAC , Rsnb AC Line ZC - Csnb Trigger - Inductive Load with snubber Figure 9. Inductive Load With Snubber www.vishay.com 4 Vishay Semiconductors Instead of resorting to a snubber and
Vishay Semiconductors
Original
EN61000-4-4 RC snubber dv/dt diode RC snubber dv/dt across scr triac CIRCUIT phototriac RC snubber scr design TRIAC application note snubber IL411X

triac ZO 410 MF

Abstract: General Electric SCR Manual, Fifth Edition, 1972 triac, the suddenly reapplied voltage in conjunction with the remaining stored charge in the , dv/dt within tolerable levels is to use an RC snubber network in parallel with the main terminals of , a triac is designed to conduct load current in either direction. Structurally, all thyristors consist of several alternating layers of opposite P and N silicon, with the exact structure varying with , transistors or logic families, power control integrated circuits, by optoisolated triac drivers, programmable
ON Semiconductor
Original
triac ZO 410 MF General Electric SCR Manual, Fifth Edition, 1972 Westinghouse SCR handbook Triac motor speed control rca thyristor manual Acid Battery charger 48 volt circuit tl494 HBD855/D DL137/D

Westinghouse SCR handbook

Abstract: scr C106 . . 102 Cycle Control with Optically Isolated Triac Drivers . . . . . . . . . . . . . . . . . . . , to the second half of the triac, the suddenly reapplied voltage in conjunction with the remaining , keeping the commutating dv/dt within tolerable levels is to use an RC snubber network in parallel with , integrated circuits, by optoisolated triac drivers, programmable unijunction transistors (PUTs) and SIDACs , amps, with breakover voltages from 77 to 400 volts. NP Series Thyristor Surge Protector Devices (TSPD
ON Semiconductor
Original
scr C106 OPTO TRIAC moc 3041 ZO 103 TRIAC sine wave inverter tl494 circuit diagram thyristor driving circuit by using opto moc3022 1N4007 germanium diode

triac bta06

Abstract: TRIAC BTB 16 600 BW in parallel with the TRIAC is generally used (see Figure 13). This "snubber" is calculated to limit , . . . . . . . . . . . . . . . . . . . . . . . 4 1.3.1 1.3.2 1.4 2 TRIAC with resistive load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TRIAC with inductive load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TRIAC without snubber , limitation. Figure 4 represents the curve of the commutation behavior obtained with a standard 4 A TRIAC
STMicroelectronics
Original
triac bta06 TRIAC BTB 16 600 BW Z0405 equivalent OPTO TRIAC TRIAC BTA 16 600b TRIAC BTB 12.600 data sheet AN439

TRIAC BTB 16 600 BW

Abstract: TRIAC BTa 12 600 BW application note behavior of the triac under consideration. Figure 3 represents the results obtained with a standard 12A , applications it is always necessary to know the (di/dt)c of the circuit in order to choose a triac with a , increasing voltage, we generally use a resistive/capacitive network mounted in parallel with the triac. This , 0 0 t t Supply Voltage (A) (B) The use of a triac without a snubber network , commutation on an inductance load without a snubber network ­VCC R DIAC OPTO COUPLEUR (Photo Triac
STMicroelectronics
Original
TRIAC BTa 12 600 BW application note zero crossing opto diac BTA16-600b application motor control ac motor triac bta16 BTB16-600bw application motor control ac motor triac bta16 circuit diagram

DIAC Br100

Abstract: triac 216 lead to confusion with the triac on-state characteristic graph. Table 1 summarizes the different , snubber across the triac's main terminals is used to limit the rate of change of voltage (dV/dt) and, in , current. This can happen if the triac is triggered when blocking a high voltage and the snubber capacitor discharges too rapidly through the triac. The snubber consists of a mains-rated capacitor and a , hotspots and burn out the triac in the gate area when controlling loads with high inrush currents, such
Philips Semiconductors
Original
MSD301 MSD300 DIAC Br100 triac 216 MSD306 MSD308 diac with triac ac speed control diac triac control circuit motor 220 V

triac 216

Abstract: RC snubber dv/dt handbook the need for a protective snubber. The use of a Hi-Com triac greatly simplifies circuit design and , particular junction temperature. If a triac has to be operated in an inductive load circuit with a , Commutation with various loads For resistive loads, a triac's current is in phase with the line voltage , . Philips Semiconductors' 3-quadrant triac range includes the original Hi-Com types, with highest , - a three-quadrant triac FS013 - Understanding high-commutation triacs Philips Semiconductors
Philips Semiconductors
Original
RC snubber dv/dt handbook Triac slow on 3-phase motor triac scs thyristor parallel triac three phase triac control

Optocoupler MOC 3020

Abstract: Optocoupler triac 80a possibilities. Prevention requres the addition of a RC snubber across the TRIAC and an inductor in series with , the thyristor. These components along with the load inductance form a series CRL circuit. Snubber , sample from the four different TRIAC die sizes. Snubber operation relies on the charging of the , Transients Table 1. Minimum Non-inductive Snubber Resistor for Four Quadrant Triggering. TRIAC Type , section defines the SLOW maximum allowed current. dI dt Inductance in series with the snubber
Fairchild Semiconductor
Original
Optocoupler triac 80a HP 2200 optocoupler AN3008 Fairchild ac motor speed control circuit with triac and moc WESTINGHOUSE motor life line OPTO TRIAC moc AN-3008 AN300000

Application Note 35

Abstract: triac RC snubber Simplifies TRIAC Circuit with Snubber Max di/dt Max dV/dt This equation is derived from the , them (the inductive load's voltage leads its current). This presents a unique problem with TRIAC , time for the TRIAC to turn off. This is not something that is encountered with simple SCRs, where the , dV/dt seen by the TRIAC. This involves implementing an RC snubber circuit across the load, such as , Trigger - Fig. 12 - Inductive Load with Snubber APPLICATION NOTE Instead of resorting to a
Vishay Semiconductors
Original
Application Note 35 triac snubber ac motor how to test triac snubber application note rc snubber for electromagnetic relays SCR TRIAC

thyristor firing control circuit with optocoupler

Abstract: rc Snubber circuits theory, design and application on a common heatsink helps. A stable blocking condition for operation of a single triac with no , at the operating conditions. For example, if leakage doubles every 10°C, a triac operating with 2 , aided voltage sharing. The triac with the highest current gain in the pair is most likely to turn-on , require the addition of a series snubber inductor. The snubber must be designed for maximum dV with the , with non-storage oscilloscopes. This type of damage can be consequence of snubber design, transients
Motorola
Original
thyristor firing control circuit with optocoupler rc Snubber circuits theory, design and application thyristor applications OPTOCOUPLER for thyristor gate OPTOCOUPLER thyristor T106 thyristor AN1045 T106-6 MKP1V130

BTA16-600b application motor control

Abstract: TRIAC BTB 16 600 BW /capacitive network mounted in parallel with the triac. This "snubber" is calculated to limit the (dv/dt)c , switch with only one gate (fig. 1a). In considering the structure of a triac (fig. 1b), one notices , the triac under consideration. Figure 3 represents the results obtained with a standard 12 Amp , the circuit in order to choose a triac with a suitable critical (di/dt)c. This is the most important , of phase control 4/10 ® APPLICATION NOTE The use of a triac without a snubber network The
STMicroelectronics
Original
TRIAC BTB 12 600 B TRIAC BTa 16 600 BW application note BTA16-600B equivalent BTA16-600B heating control diagram BTB16-600BW motor speed control TRIAC BTB 08 AN439/0592
Showing first 20 results.