Abstract: D5967 D5967 15V 0 230V 400V PRI S A FE TY ISOLATING TRANSFORMER IEC / BS EN 61558-2-6 CL1 IPOO 5 0 /6 0 H Z 504-313 10-5967 50VA ^ ^ 1 A 24V 0 24V C SEC CONNECTION DETAILS FOR 400V INPUT: NEUTRAL TO PRI 0 & LIVE TO 400V FOR 415V INPUT: NEUTRAL TO PRI 15V & LIVE TO 400V FOR 230V FOR 245V INPUT: NEUTRAL TO PRI 0 S LIVE TO 230V INPUT: NEUTRAL TO PRI 15V & LIVE TO 230V OUTPUT IS 2 4 -0 -2 4 V CENTRE TAPPED OUTPUT OR FOR 0-4BV OUTPUT CONNECT TO (LH) 24V & (RH) 24V ACROSS FU LL ... OCR Scan
datasheet

1 pages,
65.29 Kb

transformer centre tapped RH -24V D5967 Transformer 230V 24V transformer 400V 230v to 15v transformer 230V -15V TRANSFORMER D5967 abstract
datasheet frame
Abstract: RoHS Compliant 2.56:1 Impedance Ratio Center Tapped Transformer 5-65 MHz Features · · · · , Impedance Ratio Center Tapped Transformer 5-65 MHz MABA-007902-CF38A0 MABA-007902-CF38A0 V1P Electrical Specifications , :1 Impedance Ratio Center Tapped Transformer 5-65 MHz MABA-007902-CF38A0 MABA-007902-CF38A0 V1P Typical , Description M/A-COM's MABA-007902-CF38A0 MABA-007902-CF38A0 is a 2.56:1 RF flux coupled step up transformer in a low cost , Pin Configuration Pin No. Function 1 Secondary Dot 2 Centre Tap 3 Secondary 4 ... Original
datasheet

3 pages,
69.18 Kb

center tap transformer centre tapped Transformer M513 MABA-007902-CF38A0 MABA-007902-CF38TB MABAES0017 SM-138 transformer centre tap primary center tapped power transformer transformer centre tapped center tap transformer 18 0 18 center tapped transformer MABAES0017 abstract
datasheet frame
Abstract: 40Hz and 25Hz. Centre tapped primaries suit balanced microphone applications. Type Height , E187B E187B 250 3.6:1+1 3 k 250 Miniature Encapsulated Audio Input Transformer Part Number Z1604 Z1604 , ) Fixing Centre B18A001F B18A001F 2W 43 36 33 190 52x4BA P74A001F P74A001F 5W 50 41 36 ... Original
datasheet

2 pages,
77.98 Kb

Z1604 60Hz2 71x2 audio transformers Z1604 B18A001F E187A E187B transformer centre tapped 100v audio amplifier X187A datasheet abstract
datasheet frame
Abstract: DAGNALL ELECTRONICS LIMITED Shuttleworth Road, Elms Industrial Estate, Bedford. MK41 0EP UK TEL +44(0)1234 330077 FAX +44(0)1234 330088 E-mail sales@dagnall.co.uk Iss 1 28/08/03 1 of 2 P R O D U C T D A T A S H E E T 1.2VA PCB MOUNTED ENCAPSULATED TRANSFORMER Manufactured to BS415 BS415 Class 2, VDE0550 VDE0550 Class 2 and IEC742 IEC742 Class 2. Single 240V primary. Centre tapped Secondaries total rating 1.2VA. Rugged Encapsulated Construction. Suitable for flow soldering. 4.4kV Isolation Primary ... Original
datasheet

2 pages,
338 Kb

VDE055 transformer 240v to 15v Dagnall Electronics transformer 6-0-6v dagnall transformer 15-0-15v dagnall transformer 240v transformer 240v A 12V IEC742 d3602 bs415 transformer 240V to 12-0-12v D3604 datasheet abstract
datasheet frame
Abstract: heated valves by the use of a small centre tapped resistance across the filament terminals. In common , COSSOR P.T.4I 4-VOLT I AMP. DIRECTLY HEATED PENTODE The P.T. 41 is a directly heated pentode valve capable of delivering a volume of undistorted output sufficient for all domestic purposes ; at the same time the sensitivity is sufficiently high to permit it to be fully loaded by a detector with transformer coupling. It is very similar to the M.P./Pen., but may have advantages in certain receivers by ... OCR Scan
datasheet

1 pages,
46.72 Kb

datasheet abstract
datasheet frame
Abstract: applications Transformer meets IEC950 IEC950 insulation requirements V DE Frequency range from 20kHz to 200kHz Electrical Specifications @ 25°C - Operating Temperature -40°C to 130°C Part Number Transformer with , Number Part Number Transformer Schem. Inductor without with 1T Figure Primary Primary 1C 1C , resistance, the inductor scale factor is Vout = 1 volt per amp. for center tapped units terminating , 20 amps for all parts listed above. Mechanicals Schematics Inductor Transformer 1 6 3 ... Original
datasheet

1 pages,
78.54 Kb

PE-64488 PE-64517 PE-63586 pe 63587 pe63619 PE-64519 PE-63588 PE-63618 transformer 12 v center tapped PE-51686 PE-64518 PE-51719 PE-63617 PE-63587 IEC950 IEC950 abstract
datasheet frame
Abstract: RoHS Compliant 2.56:1 Impedance Ratio Center Tapped Transformer 5-65 MHz Features · · · · , Compliant 2.56:1 Impedance Ratio Center Tapped Transformer 5-65 MHz MABA-007902-CF38A0 MABA-007902-CF38A0 V1P , notice. RoHS Compliant 2.56:1 Impedance Ratio Center Tapped Transformer 5-65 MHz , Description M/A-COM's MABA-007902-CF38A0 MABA-007902-CF38A0 is a 2.56:1 RF flux coupled step up transformer in a low cost , Pin Configuration Pin No. Function 1 Secondary Dot 2 Centre Tap 3 Secondary 4 ... Original
datasheet

3 pages,
58.75 Kb

SM-138 MABAES0017 MABA-007902-CF38TB MABA-007902-CF38A0 M513 centre tapped transformer center tapped transformer MABAES0017 abstract
datasheet frame
Abstract: centre tapped transformer in an identical manner to the more common method of push-pull. ,- Anode to Anode Load Transformer ratio- \i- ' Minimum Speaker Impedance. The recommended value of anode to , In the table overleaf. The intervalve transformer ratio will depend on the type of detector valve , L.2I/DD are used as detector amplifiers the transformer ratios should be I : 2 and I : 4 respectively. , filter must be connected across the primary of the output transformer. A suitable value of resistance is ... OCR Scan
datasheet

2 pages,
127.09 Kb

speaker with screen radio output transformer matching transformer P A speaker centre tapped Transformer datasheet abstract
datasheet frame
Abstract: output the 250 (¿F capacitors should be used. A centre tapped inductor, or a transformer, may be used , resistors, Rl(j, R17, have their anodes connected to an output transformer, details of which are given , components common in television receivers. A tapped resistor caters for various AC and DC mains voltages. The , increase in the input signal required. The output transformer Ref. C2203 C2203, for the ultra linear circuit, is provided with a tap on each half-primary at one fifth of the turns, measured from the centre tap. Two small ... OCR Scan
datasheet

16 pages,
846.88 Kb

twin-t inductor STC marconi marconi company motor operated valve RECTIFIER GI 12v dc to 220 ac transformer FULL WAVE RECTIFIER CIRCUITS 220 AC rm5 electrolytic capacitor KT55 barretter partridge transformer datasheet abstract
datasheet frame
Abstract: balanced-unbalanced operation. The centre tapped secondary transformer in 3c is a balanced 2 signal splitter which , N Fig 3b ­ Conventional Transformer Fig 3c ­ Centre Tapped Secondary Higher permeability (· , magnetic material. From Faradays' law it can be shown that, for an ideal transformer, the voltage per turn , Figure 3 below shows the simplest configurations. The autotransformer in 3a has a tapped continuous winding and provides a DC short between input and output. Figure 3b shows a more conventional transformer ... Original
datasheet

14 pages,
883.39 Kb

brown boveri novel matching systems Boveri 300w amplifier 30mhz storm COAXIAL CABLE RF transformer turn ratio impedance matching transformer uhf 1kw amplifier transistors 5287 H C 5287 equivalent 300w rf amplifier uhf transistor c 5287 transformers 325 339 datasheet abstract
datasheet frame

Datasheet Content (non pdf)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2014): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
Heater secondary voltage: 6· 3V AC centre- tapped (3· 15-0-3· 15V Description: A mains transformer for high power valve circuits centre-tapped heater secondaries.The transformer is intended for mounting on top of a chassis where one side of continuous heavy duty use, one channel per transformer (monoblock) is advised.
www.datasheetarchive.com/files/maplin/products/06/4/72prodd.htm
Maplin 28/02/2002 11.08 Kb HTM 72prodd.htm
Example 7.6 Rectifier with single-phase centre tapped transformer * Primary is modelled as a voltage source of 120V peak at 60Hz with * zero offset voltage VP 1 0 SIN(0 120 60Hz) * Primary winding is assumed to have a very high resistance: R1 = 10Meg R1 1 0 10GOHM 10GOHM 10GOHM 10GOHM * Secondary winding is assumed to be a voltage controlled voltage source * with a voltage gain of 0.1. E1 2 3 1 0 0.1 E2 3 0 1 0 0.1 C1 4 3 50UF RL 4 3 500 * Diode D1 with model name DIODE D1 2 4 DIODE D2 0 4 DIODE
www.datasheetarchive.com/files/spicemodels/misc/modelos/fullwave.cir
Spice Models 18/04/2010 0.82 Kb CIR fullwave.cir
(7.3V off load, centre tapped) * Lsec73a 9 27 111mH Rsec73a 27 10 0.15 Rsec73b 10 28 0.15 Lsec73b * * Trace Elliot Velocette 12R Mains Transformer * Part no. 73 TRAN 15W VG2 * * [1] Brown -. || .- Purple [5] * ) || ( * 120V ) || ( 28V * ) || .- Purple [6] * [2] Blue -. || .- Red [7] * || ( * [3] Brown -. || ( * ) || ( 313V * 120V ) || ( * ) || .- Black [8] * [4] Blue -.
www.datasheetarchive.com/files/spicemodels/misc/spice_model_cd/mixed part list/transformers/tracevg2.lib
Spice Models 29/07/2012 1.08 Kb LIB tracevg2.lib
8 75.5 * * Secondary 7.3v offload centre tapped) * Lsec73a 9 27 111m Files\AnaSoft\SuperSpice\system\Transformers.ssm] [Transformer] * main circuit V_ssi_pin3 \AnaSoft\SuperSpice\system\Transformers.ssm] [Transformer] * * (c) Kevin Aylward 2002 - All rights reserved *This is a nominl/typical iron core transformer *H array is in A/M B array is in Tesla *Length \AnaSoft\SuperSpice\system\Transformers.ssm] [Transformer] * * (c) Kevin Aylward 2002 - All rights
www.datasheetarchive.com/files/spicemodels/misc/models/transformers.lib
Spice Models 27/08/2003 20.07 Kb LIB transformers.lib
drive, output stage through a centre tapped transformer to facilitate power supply switching directly drive the primary side of a center tapped transformer. The receive path contains a The center tap of the primary side of the transformer is connected to a supply that can be center tap of the transformer. Input bias current 3 15 m A Measured at pin PAIP/PAIN. 59 dB dB dB dB dB Measured at the line impedance. The 4 to 1 transformer must have
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/7442.htm
STMicroelectronics 07/12/2000 39.97 Kb HTM 7442.htm
for system reliability. Input caps can affect also the system efficiency. The transformer could be a single secondary wind - ing with four diodes for rectification or centre tapped with two diodes only MAINS TRANSFORMER POWER SUPPLY, WITH OUTPUT ADJUSTABLE FROM 0V TO 24V . Fig A1 shows a power supply including mains transformer, working at 50Hz 220Vac or 60Hz 110Vac, bridge rectifier and filtering efficiency of 93-95%, the mains transformer has to be designed around 200VA 200VA 200VA 200VA. A low voltage secondary pfc
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5410.htm
STMicroelectronics 20/10/2000 38.57 Kb HTM 5410.htm
reliability. Input caps can affect also the system efficiency. The transformer could be a single secondary wind - ing with four diodes for rectification or centre tapped with two diodes only, but higher reverse 15/20 APPLICATION IDEAS MAINS TRANSFORMER POWER SUPPLY, with output adjustable from 0V to 24V. Fig A1 shows a power supply including mains transformer, working at 50Hz 220Vac or 60Hz 110Vac, bridge transformer has to be designed around 200VA 200VA 200VA 200VA. A low voltage secondary pfc can reduce the VA need close to the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5410-v2.htm
STMicroelectronics 14/06/1999 33.63 Kb HTM 5410-v2.htm
reliability. Input caps can affect also the system efficiency. The transformer could be a single secondary wind - ing with four diodes for rectification or centre tapped with two diodes only, but higher reverse 15/20 APPLICATION IDEAS MAINS TRANSFORMER POWER SUPPLY, with output adjustable from 0V to 24V. Fig A1 shows a power supply including mains transformer, working at 50Hz 220Vac or 60Hz 110Vac, bridge transformer has to be designed around 200VA 200VA 200VA 200VA. A low voltage secondary pfc can reduce the VA need close to the
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5410-v1.htm
STMicroelectronics 02/04/1999 33.67 Kb HTM 5410-v1.htm
efficiency. The transformer could be a single secondary wind - ing with four diodes for rectification or centre tapped with two diodes only, but higher reverse voltage. Considering a max output power close to 100W, equivalent system efficiency of 93-95%, the mains transformer has to be designed around Phase Bode plot open loop AN938 AN938 AN938 AN938 APPLICATION NOTE 15/20 APPLICATION IDEAS MAINS TRANSFORMER transformer, working at 50Hz 220Vac or 60Hz 110Vac, bridge rectifier and filtering capacitor; the output
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/5410-v3.htm
STMicroelectronics 03/10/2000 36.38 Kb HTM 5410-v3.htm
#FILE = E2KCOMM.TXT 'EDWin 2000 Common Strings Eng' 991 ~ ~ #branch 992 ~ ~ % ( to Cancel) 993 ~ ~ &Help 994 ~ ~ &Abort 995 ~ ~ &Absolute 996 ~ ~ &AC Sweep 997 ~ ~ &Accept 998 ~ ~ &Active layers 999 ~ ~ &Add 9910 ~ ~ &All 9911 ~ ~ &Auto 9912 ~ ~ &Block edit 9913 ~ ~ &Board datum 9914 ~ ~ &Break 9915 ~ ~ &Cancel 9916 ~ ~ &Centre 9917 ~ ~ &Close 9918 ~ ~ &Color 9919 ~ ~ &Colors 9920 ~ ~ &Common-units 9921 ~ ~ &Comp side 9922 ~ ~ &Components 9923 ~ ~ &Continue 9924
www.datasheetarchive.com/files/kaleidoscope/cad/visionics_edwinxp140/country/polish/e2klocal.txt
Kaleidoscope 10/05/2004 373.4 Kb TXT e2klocal.txt