NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: face view 1 46,5 Via integral transformer ZB4-BV3, 4 + ZB4-BV0p 11 e 11,5 11,5 e , ZB4-BW0ppp + ZB4-BW3pp + ZBE-ppp Via integral transformer ZB4-BW0pp + ZB4-BW3p Common face view 46 , connector terminals: 32 x 45 min. General: pages 1/2 to 1/7 Schneider Electric Characteristics , Dimensions Control and signalling units Ø 22 Harmony® style 4 Pushbuttons, switches and , return ZB4-BAp + ZB4-BZppp + ZBE-ppp ZB4-BLp + ZB4-BZppp ZB4-BPp + ZB4-BZppp Common face view ... | Original |
5 pages, |
ZB4BS944 ZB4BS54 BS944 BZ141 HARMONY SCHNEIDER ZB4-BS514 ZB4-BS844 ZB4-BS944 transformer min 4 pages BS834 ZB4-BV6 BS844 ZB4-BS54 datasheet abstract |
| Abstract: are center tapped and terminated when there is no auto transformer. See pages 3 & 4 for alternate , 3001 1000BASE-T 1000BASE-T ELECTRICAL CHARACTERISTICS @ 25°C Inductance: 350uH Min with 8mA DC Bias, 0°C - 70°C (each transformer) Rise time (10 - 90%): 2.5 nSec typical LED Forward Current: 5 mA , ) * Return Loss (dB MIN) Crosstalk Attenuation (dB MIN) CMRR (dB MIN) .100 MHz - .999 MHz 1.0 , 2 49 3 4 50 48 T2 T10 5 47 46 1 50 3 48 4 47 6 45 ... | Original |
6 pages, |
PCB MOUNT CURRENT TRANSFORMER GB3G04-2 GB3G04-1 GB3G04 GB3G01-2 GB3G01-1 GB3G01 1000BASE-T MAGNETIC MODULE Transpower Technologies 10/100/1000BASE-T 10/100/1000BASE-T abstract |
| Abstract: OUTPUT STAGE SWITCHING FREQUENCY GENERATOR TONE FREQUENCY GENERATOR 3 4 7 IN + , 5 2 3 C1 100 uF 4 R1 14 k f 2 = 0.725 f 1 -3- Total 5 Pages VOUT f , 26 V, RA = 14 k, Csw = 0.1 uF f sw -4- Total 5 Pages kHz 1.22 1.6 kHz 1.33 , 4 C1 100 uF R1 14 k Figure 3: Typical Application with Loudspeaker (no transformer , parallel operation of 4 devices. Integrated rectifier bridge with zener diodes to protect against ... | Original |
5 pages, |
bl1240 BL1240 BL1240 abstract |
| Abstract: transformer, with LED pilot light 230 V a 50/60 Hz primary, N/O + N/C contact 6 V secondary. BA 9s , stay put N/O + N/C contact 4 direction Joystick controllers D 2 direction A 0 B A , transformer Screw clamp terminals ZB5-AVp/AV3Dp(1)/AV5Dp(1) see page 2/21 Characteristics: pages 2/6 to 2/9 2/4 References: pages 2/10 to 2/47 Dimensions: pages 2/48 to 2/55 Schneider Electric , push ZB5-AW1p see page 2/29 Via integral transformer Screw clamp terminals ZB5-AW03/4/5/3D/5D ... | Original |
10 pages, |
IEC 60947-5-1 joystick as6 diode A600 XB5DSB datasheet abstract |
| Abstract: Control and signalling units Ø 22 General : pages 1/2 to 1/9 References : pages 1/14 to 1/53 Dimensions : pages 1/54 to 1/61 Harmony style 4 Pushbuttons, switches and pilot lights, with chromium , References : pages 1/14 to 1/53 Dimensions : pages 1/54 to 1/61 Harmony style 4 Pushbuttons, switches , 1/9 References : pages 1/14 to 1/53 Dimensions : pages 1/54 to 1/61 Harmony style 4 , with integral LED : Uimp = 4 Pilot light blocks with transformer : Uimp = 6 Electrical ... | Original |
4 pages, |
R300 A300 A600 B300 DC-13 EN 60947-5-1 IEC 60947-5-1 joystick Q600 947-1 IEC 269-1 IEC 947-1 datasheet abstract |
| Abstract: Emergency stop with N/C + N/O 2/10 Te Control and signalling units Ø 22 General : pages 2/2 to 2 , with integral LED : Uimp = 4 Pilot light blocks with transformer : Uimp = 6 Specific , Control and signalling units Ø 22 General : pages 2/2 to 2/9 References : pages 2/14 to 2/55 Dimensions : pages 2/56 to 2/63 Harmony style 5 Pushbuttons, switches and pilot lights, with double , Single N/O contact: 2.3 N N N Double contact, N/C + N/C : 3.4 Double contact, N/O + N/O : 5 ... | Original |
4 pages, |
947-1 R300 Q600 DC-13 B300 A600 A300 IEC 269-1 IEC-947-5-1 AC15 B300 datasheet abstract |
| Abstract: selected pressing the PAG button returns the instrument to the measurement pages. Transformer 5/5 20/5 , 600Hz Input impedance _4M½(min.) Operating temperature range , scales VIP96 VIP96 37Vrms 24mV 37.0V 0.5% FS + 0.5% Rdg 174Vrms 111mV 174V 0.3% FS + 0.3% Rdg 650Vrms 416mV 650V 0.3% FS + 0.3% Rdg Sensitivity and accuracy in current measurements Direct input with , Full scales 0.25A 1.16A 5.00A VIP96 VIP96 0.5% FS + 0.5% Rdg 0.3% FS + 0.3% Rdg 0.3% FS + 0.3% Rdg ... | Original |
4 pages, |
20 kva transformer VIP96 transformer 3000 kVA datasheet abstract |
| Abstract: failure, end of life, detecting base current of half-bridge and so on. 4. The BL8305A BL8305A have an internal , for ballast with few external components. http://www.belling.com.cn -1Total 8 Pages 8/28/2006 , 8 Pages 8/28/2006 BL8305A BL8305A BALLAST CONTROL IC BLOCK DIAGRAM LEAD ASSIGNMENTS & DEFINITION Pin# 1 2 3 Symbol VCC VDC Rpre 4 5 6 7 8 9 10 11 12 13 14 Rt Ct Cpre POff , detection input Window discriminator input Half-bridge output sense OUTPUT2 OUTPUT1 -3Total 8 Pages ... | Original |
8 pages, |
Ignition Transformer FR107 IN4148 IRF830 ignition mosfet BL8301 t8 ballast circuits 13005 ld1 BL8305A Window Discriminator SEC 13005 transistor 13005 13005 mosfet power supply IRF830 APPLICATION BL8305A abstract |
| Abstract: ? 2 ? 115uH 6 4 ? 5 Vsupply + 132Vdc ? CRT Deflection angle Neck , ) 4 15.6 ø1 16.5 max FLYBACK TRANSFORMER SPECIFICATION 1352.3029 D CUSTOMER CODE , 22030 ORSENIGO - Como - Italy Tel. +39 031 636111 - Telefax +39 031 632243 FLYBACK TRANSFORMER , M.Frasca G.Toscano DOCUMENTO N / document Nbr: W4.04 220 131 PAGINE MODIFICATE: changed pages , Withstanding voltage The transformer shall withstand a voltage of 1.5kV r.m.s. for 60 seconds between each ... | Original |
5 pages, |
HV transformer specification flyback transformer pin description 10 pin flyback transformer crt crt and eht transformer ohmmeter circuit diagram philips fbt flyback transformer HV HV transformer 5kv 12 pin flyback transformer flyback transformer diagram flyback transformer philips datasheet abstract |
| Abstract: ) -0.5, Vcc + 0.5 Vdc -65 to +150 ºC Supply Voltage (Pin 4) Storage Temperature Range , ://www.belling.com.cn -4- Total 11 Pages 8/15/2006 Wrote by 2006 BL34118 BL34118 ATTENUATOR CONTROL (TA = +25°C , Vcc Vcc 4 - - 10 - Total 11 Pages CD 3 AGC Vcc 100k 47uF Attenuator , amplifiers, which can be used to form a hybrid network in conjunction with an external coupling transformer , Ring (through a coupling transformer) for stand-alone operation, or it can be used in conjunction with ... | Original |
11 pages, |
BL34 1N4733 BL34119 bl34118 BL34118 BL34118 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| Insulated WDG #3 25 T 3 X 24 AWG FL3 FL4 Page 2 of 3 Forward Transformer Drawing: 19.5V Output windings open1 MHz (Min.) Leakage Inductance FL 1-2, with FL 3-4shorted 5 uH (Max.) TRANSFORMER CONSTRUCTION WINDING INSTRUCTIONS: FL1 FL2 FL3 FL4 Page 3 of 3 Forward Transformer Drawing: 19.5V Output (RD8 Page 1 of 3 Forward Transformer Drawing: 19.5V Output (RD8) 12/18/97 Transformer, ES8_FOR MATERIALS Wire: 26 AWG Triple Insulated [3] Magnet Wire: 24 AWG Triple Insulated [4] Tape: 3M 1298 or equiv. 6 mm www.datasheetarchive.com/download/84836357-689774ZC/designkit3.zip (DK3for1.PDF) |
Power-Integrations | 28/11/2000 | 123.23 Kb | ZIP | designkit3.zip |
| COMPACT_4.Normal TRANSFORMER FLAT COMPACT_4.Normal VOUT PGND FAULT HIPWR PGND SYNC ISENSE Gate VOUT PGND TRANSFORMER FLAT COMPACT_3 TRANSFORMER FLAT COMPACT_3.Normal TRANSFORMER FLAT COMPACT_4 TRANSFORMER FLAT COMPACT_4 TRANSFORMER FLAT COMPACT_4.Normal TRANSFORMER FLAT COMPACT_5 TRANSFORMER FLAT COMPACT_5 FLAT COMPACT_3 TRANSFORMER FLAT COMPACT_3 TRANSFORMER FLAT COMPACT_3 TRANSFORMER FLAT COMPACT_4 TRANSFORMER FLAT COMPACT_4 TRANSFORMER FLAT COMPACT_4 TRANSFORMER FLAT COMPACT_5 TRANSFORMER FLAT COMPACT_5 www.datasheetarchive.com/download/41339570-364635ZC/1226.zip (1226a.DSN) |
Linear | 22/09/2009 | 642.7 Kb | ZIP | 1226.zip |
| Power Integrations,Inc. DK6 (Margin Wound Transformer) Page 1 of 3 03/18/98 Transformer, T1 (Margin Wound Transformer) Electrical Specifications Electrical Strength 60Hz 1minute, from Pins 1-4 to Pins 5 MHz (Min.) Primary Leakage Inductance Pins 5-10 shorted 55uH 1 2 4 3 9,10 6,7 116T #35AWG 35AWG 35AWG 35AWG 14T #35AWGx2 6T #26AWG 26AWG 26AWG 26AWG x2 Power Integrations,Inc. DK6 (Margin Wound Transformer) Page 2 of 3 03/18/98 Transformer Bias Tape Margins Power Integrations,Inc. DK6 (Margin Wound Transformer) Page 3 of 3 03/18/98 Materials www.datasheetarchive.com/download/67620444-689777ZC/designkit6.zip (DK6Xfmr2.PDF) |
Power-Integrations | 28/11/2000 | 138.94 Kb | ZIP | designkit6.zip |
| voltage, etc). 2 - Enter TOPSwitch ("TOP412" or "TOP414") 3 - Select the Transformer Core 4 -LETTER SCALING = 73% for A4 - for single page print, set SCALING = 52% for US (Revision A) 3. Design Methodology - AN16 4. Readme_061699.txt - this file The TinySwitch Flyback Transformer Design Spreadsheet is provided as a single Excel 5.0 spreadsheet for designing flyback transformers operating in the continuous or discontinuous mode of operation. It has READ-ONLY attribute set www.datasheetarchive.com/files/power-integrations/piwebsite/linkedfiles/readme_dctodc_061699.txt |
Power-Integrations | 28/11/2000 | 2.49 Kb | TXT | readme_dctodc_061699.txt |
| Page 1 of 3 Flyback Transformer Drawing: 19.5V Output (RD8) 12/18/97 Transformer, ES8_FLY MATERIALS ,12 7,8 Page 2 of 3 Flyback Transformer Drawing: 19.5V Output (RD8) 12/18/97 Electrical Strength 60Hz 1 half) 6 3 1 7,8, 5 11,12 2 2 Page 3 of 3 Flyback Transformer Drawing: 19.5V Output (RD8) 12 2620, TDK BPQ26/20-1112CP BPQ26/20-1112CP BPQ26/20-1112CP BPQ26/20-1112CP or equiv. [3] Magnet Wire: 26 AWG Heavy Nyleze [4] Magnet Wire: 24 AWG Triple Insulated [5] Tape: 3M 1298 or equiv. 9.2 mm wide [6] Sleeving, Teflon, 24 AWG, 0.4mm wall thickness [7 www.datasheetarchive.com/download/84836357-689774ZC/designkit3.zip (DK3fly1.PDF) |
Power-Integrations | 28/11/2000 | 123.23 Kb | ZIP | designkit3.zip |
| -LETTER SCALING = 73% for A4 - for single page print, set SCALING = 52% for US . Design Methodology - AN25VA AN25VA AN25VA AN25VA.pdf (preliminary) 4. Readme_020700.txt - this file The TOPSwitch-FX Flyback Transformer Design Spreadsheet is provided as a single Excel 5.0/Win95 spreadsheet for designing flyback transformers operating in the continuous or discontinuous mode of operation. It has READ spreadsheet - The TOPSwitch-FX Flyback Transformer Design Spreadsheet, follows the www.datasheetarchive.com/files/power-integrations/piwebsite/linkedfiles/readme_041400.txt |
Power-Integrations | 28/11/2000 | 3.17 Kb | TXT | readme_041400.txt |
| , KP) 4 - Choose Transformer Core type 5 - Enter other transformer design parameters (L, NS) 6 -LETTER SCALING = 73% for A4 - for single page print, set SCALING = 52% for US .pdf (Revision A) 3. Design Methodology - AN25VA AN25VA AN25VA AN25VA.pdf (preliminary) 4. Readme_020700.txt - this file The TOPSwitch-FX Flyback Transformer Design Spreadsheet is provided as a single Excel 5.0/Win95 spreadsheet for designing flyback transformers operating in the continuous or discontinuous mode of operation www.datasheetarchive.com/files/power-integrations/piwebsite/linkedfiles/readme_020700.txt |
Power-Integrations | 28/11/2000 | 3.14 Kb | TXT | readme_020700.txt |
| -LETTER SCALING = 73% for A4 - for single page print, set SCALING = 52% for US -GX Flyback Transformer Design Spreadsheet is provided as a single Excel 5.0/Win95 spreadsheet for designing flyback transformers operating in the continuous or discontinuous mode of operation. It has READ spreadsheet - The TOPSwitch-GX Flyback Transformer Design Spreadsheet, follows the Variables" such as (VACMIN - min input AC voltage, FL - line frequency, etc). 2 - Choose the www.datasheetarchive.com/files/power-integrations/piwebsite/linkedfiles/readme_112000.txt |
Power-Integrations | 28/11/2000 | 3.04 Kb | TXT | readme_112000.txt |
| MAX845 MAX845 MAX845 MAX845 Isolated Transformer Driver for PCMCIA Applications QuickView Data Sheet: CONTAINS KEY INFORMATION FROM THE DATA SHEET FRONT PAGE. For complete information, in Adobe Acrobat -tapped transformer primary from a 5V or 3.3V DC power supply. The secondary can be wound to provide any isolated half the oscillator frequency (450kHz, min). These two signals drive the ground-referenced N Transformer Driver for Ultra-Thin 5V-us Transformers Isolated DC-to-DC Power Supply for PCMCIA www.datasheetarchive.com/files/maxim/0011/quick008.htm |
Maxim | 04/04/2001 | 6.27 Kb | HTM | quick008.htm |
| model is 25C - ESR and ESL of capacitors are zero. - Wire DCR and leakage inductances of transformer are - Deadtime Also GND pin of LM5030 LM5030 LM5030 LM5030 is internally tied to GND (node number 0) a. Transformer model includes the H It is an ideal transformer. All parasitic elements should be added additionally to make it a practical transformer model. b. To run the simulation, a simulation profile should be added first-> click 'New Simulation Profile' c. The simulation takes around 1~3min actual time per 1mSec simulation on a 1 www.datasheetarchive.com/download/61154908-920976ZC/snvm017.zip (LM5030.DSN) |
Texas Instruments | 17/01/2012 | 596 Kb | ZIP | snvm017.zip |