500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT3439EFE Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TRPBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#TR Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3439EFE#PBF Linear Technology LT3439 - Slew Rate Controlled Ultralow Noise 1A Isolated DC/DC Transformer Driver; Package: TSSOP; Pins: 16; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2151IUJ-12#PBF Linear Technology LTC2151-12 - Single 12-Bit 210Msps ADCs; Package: QFN; Pins: 40; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LTC2153IUJ-12#PBF Linear Technology LTC2153-12 - 12-Bit 310Msps ADC; Package: QFN; Pins: 40; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

transformer from 230V AC to 28v

Catalog Datasheet MFG & Type PDF Document Tags

accessories

Abstract: 185E28 61-8-8240-2244 A.C. Secondary Voltage - Selection Guide Primary (VAC) 115/230V 50/60 Hz. 115V 60 Hz. 115V , Quick Tab -Transformer Locator Power: 2-44 Power Chokes: 45-54 Chokes Line: 55-68 , Power A.C. Secondary Voltage - Selection Guide Primary (VAC) 117/234V 50/60 Hz. 115V 60 Hz. 115V , /234V 50/60 Hz. 117/234V 50/60 Hz. 115V 60 Hz. 115/230V 50/60 Hz. 115V 60 Hz. 115/230V 50/60 Hz. 115V 50/60 Hz. 115/230V 50/60 Hz. 115V 60 Hz. 115V 60 Hz. 115/230V 50/60 Hz. 115/230V 50/60 Hz
Hammond Manufacturing
Original
accessories 185E28 6l6gc 230v to 12v step down transformer princeton speaker protection circuit ic schematic diagram inverter 12v to 115v 400 hz 115/230V

230v input to 12v output as step down transformer

Abstract: 12V DC to 230V AC inverters circuit diagram sealed transformers with power ratings from 0.6VA to 60VA that carry UL and VDE approvals. In addition to , every transformer requirement from our headquarters located in Aliso Viejo, California , ° ° ° ° ° Single or Dual Primary (115/230V) Designed to meet International Safety , designing a transformer that is custom tailored to fit your next project application. Zettler Magnetics , it takes to find solutions to our customers' specialized transformer applications. Whether you need
ZETTLER Electronics
Original
230v input to 12v output as step down transformer 12V DC to 230V AC inverters circuit diagram 230v to 12v center tap transformer 230v ac 5v adapter circuit schematic 230v to 12v ac step down transformer 230v 50 Hz CENTER TAP transformer

5548-03A

Abstract: 5045-03a and 28V. The unit is shipped from the factory set to 24V. To obtain 28V, customer must readjust the , Specifications (1) AC Input Voltage Rating DC Input Voltage Range AC100 - 230V, 50/60Hz (47 - 63Hz) AC90 , Current 35A MAX for E Series at nominal line (115/230V) cold start 30A MAX for F to J Series at nominal line (115/230V) cold start (3) DC Output Adjustment Range ± 10% MIN 24V output: 22.8V to , % MAX from no load to full rated load (6) Output Ripple and Noise 3/5 - 15V output 75mVp-p MAX
-
Original
P-A2-11242 AC180 DC230 5548-03A 5045-03a OVS-24H-UC OVS-15H ac 230v to dc230 tamura 24h PA211242 50/60H 132VAC DC115

MQBQ-270-28B

Abstract: ; Iout = 16A Vin = 230V to 400V Vin = 230V to 400V Bandwidth = 100kHz to 20MHz; see Figure 14 Vin = 270V; Iout = 7A Transformer turns ratio Iout = 0A to 14A Vin = 270V; Iout = 0 to 14A Vin = 270V , ; Cload=0µF Vin = 270V Vin = 230V to 400V See Note 4; Vin = 270 V Iout ≤ half load resistive 1, 1 , -270-28B Output: 28V Current: 14A Technical Specification 45 0.7 Vin = 230V 40 Vin = 230V 0.6 , -270-28B Output: 28V Current: 14A Technical Specification Figure 13: Output voltage response to step-change
Synqor
Original
MQBQ-270-28B Q-270 NAVSO-P3641-A MIL-HDBK-1547A P-3641A

SPW 078

Abstract: pst 39 transformer file a claim for damages. Discounts: Wabash Transformer offers liberal discounts to quantity , quotations from Wabash Transformer shall be valid for 30 days from the date of quotation. Inquiries for , '¢ www.wabashtransformer.com A wide range of designs to meet your requirements Wabash Transformer offers a wide range of , design a transformer as per your specific needs. Please refer to our nomenclature page no. 7 for , Table of Contents Product Description Class 2 CL UL5085-3 Transformer Lead Wires or
Wabash Transformer
Original
SPW 078 pst 39 transformer MT12/SPW 078 4-07-7016 spw -136 spw -055 transformer

15j 3kv

Abstract: 12J 3KV 28V. The unit is shipped from the factory set to 24V. To obtain 28V, customer must readjust the , . A. Electrical Specifications (1) AC Input Voltage Rating DC Input Voltage Range AC100 - 230V , to J Series at nominal line (115/230V) cold start (3) DC Output Adjustment Range ± 10% MIN 24V , Regulation ± 0.5% MAX from no load to full rated load (6) Output Ripple and Noise 3/5 - 15V output , .41 test method with no damage to power supply 22) Withstand Voltage AC 3KV (Input - Output), AC
Tamura
Original
15j 3kv 12J 3KV 5045-04A molex 230v to 75v 25w transformer OVS-24E-UC 230v ac to 32v dc without transformer
Abstract: . Note 4. OVS-24*-U has a dual rating of 24V and 28V. The unit is shipped from the factory set to 24V , AC100 - 230V, 50/60Hz (47 - 63Hz) AC90 - 264V -E Series AC90 - 132VAC / AC180 - 264V -F to J , MAX for F to J Series at nominal line (115/230V) cold start (3) DC Output Adjustment Range ± 10 , (5) Load Regulation ± 0.5% MAX from no load to full rated load (6) Output Ripple and Noise , Time 100msec MAX, from 10% to 90% of rated output voltage (10) Efficiency 70% MIN at nominal -
Original

EI - 33A TRANSFORMER

Abstract: ee20 10 transformer bobbin , linear transformer needs. With power ratings from 0.08VA to 175VA, fully encapsulated transformers, split , . . . . . . . . . . . 23 EI48 / 16.8 (AC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . , Overview With the addition of era's encapsulated 50/60Hz transformers to the existing line of Pulse open , dissipation achieved through vacuum encapsulation, resulting in more output power from a smaller, more compact , accuracy of each transformer guaranteed by stable and controlled manufacturing processes, allowing for
Pulse Engineering
Original
EI - 33A TRANSFORMER ee20 10 transformer bobbin EI38 08VA-0 A41-25-24A25 A41-43-24A26 A41-80-24A27 A41-130-24A28 A41-175-24A29

BC 2222

Abstract: ATP3 with ½VA Transformer. (Stock part) Ext. DC or AC Mains with 2VA Transformer. (To special order and , )(min) -50V @ 0mA -0.6V @ , www.axisten.co.uk Frequency to Voltage Converter ~ ATP3/1, ATP3/1M & ATP3/1M2 General Description Features · Easy to use · Max Full Scale: 100kHz @ 10V Out · Min Full Scale: 10Hz @ 10V Out · Matched to many Input Devices · Hysteresis on Inputs · One Capacitor to set Full Scale ·
Axis Ten Products
Original
BC 2222 ATP3 230v ac to 12v dc without transformer circuit BC 116 capacitor transformer 400Hz 115v 12v dc to 230v ac CIRCUITS CONVERTER 0708T 230/240V

DST4-36B26

Abstract: TRANSFORMERS Pulse offers power ratings from 1.1 VA to 175 VA, open frame transformers, with a wide variety of , transformer needs. This catalog serves as an overview for the Pulse Laminated Transformers product line , information. Low Profile Plug-In Print circuit mounting 1500 V, primary to secondary isolation Low , Dual bobbin, high (4000 V) primary to secondary isolation Non-concentric design Vacuum impregnated , mounting Dual bobbin; high (4000 V) primary to secondary isolation Non-concentric design Vacuum
Pulse Electronics
Original
DST4-36B26 LT2012 ST7-28B56 ST7-36B57 ST7-48B58 ST7-56B59 D-71083

how to convert 220v ac to 12v dc

Abstract: 12v dc to 230v ac CONVERTERS SIMPLE CIRCUITS called ``off-line'' because the DC voltage to the switch is developed right from the AC line The , feedback loop must have isolation in order for the DC output to be isolated from the AC line This is , used A power supply converting AC line voltage to DC power must perform the following functions at high efficiency and at low cost 1 Rectification Convert the incoming AC line voltage to DC voltage , military bus voltage of 28V to 5V to power TTL logic At time t(0) in Figure 4 the controller having
National Semiconductor
Original
how to convert 220v ac to 12v dc 12v dc to 230v ac CONVERTERS SIMPLE CIRCUITS convert 230V AC to 5V DC without transformer transformer winding formula 220v Ac to 12v Dc convert 230v ac to 5v dc without using transformer 500w two transistor forward converter

convert 230V AC to 5V DC without transformer

Abstract: how to convert 220v ac to 12v dc voltage to the switch is developed right from the AC line. The circuit also shows the feedback loop , order for the DC output to be isolated from the AC line. This is normally accomplished by a small , used. A power supply converting AC line voltage to DC power must perform the following functions at high efficiency and at low cost: 1. Rectification: Convert the incoming AC line voltage to DC , voltage of 28V to 5V to power TTL logic. At time t(o) in Figure 4, the controller, having sensed that
National Semiconductor
Original
AN-556 second order low pass filter advantage and disadvantages center tap transformer 230V AC to 5V DC using full-wave rectification circuit 220v to 48v switching regulator circuits push-pull converter 230V input

CB3600-DC

Abstract: t5a fuse supply Connection for power supplies from 48V AC to 230V AC MUST BE DISCONNECTED IN CASE OF 24V AC , supply C 55V AC power supply L and K D 110V AC power supply H E 230V AC power supply F I Power supply selectable from A to E Internal antenna S L-AC only G 18-28V AC power , without written authorization from IMET. This manual is subject to change with no further notice. Every , from using non-original accessories or spare parts. The same applies to any person or company involved
IMET
Original
CB3600-DC t5a fuse FS002 FS005 L250V 2002/96/CE

pt100 temperature sensor circuit diagram

Abstract: adjustable zero span circuit SUPPLY AC with transformer DC with switchmode SUPPLY VOLTAGE From 20 to 32 VDC From 20 to 28 VAC , (From 20 to 24V 110V 230V 400V (From 20 (From 99 (From 198 (From 342 C 32V) to 28V , PT100 sensor 0.75 mA - 100 to + 400 °C dipswitch programmable from - 100 to + 375 °C in steps off 25 , % pp < fs.± 0.01 % / % U supply < fs.± 0.02 % / °C Adjustable from zero to span setting Adjustable from limit to zero OUTPUT The output amplifier is protected against open- and short - circuit
Thiim
Original
pt100 temperature sensor circuit diagram adjustable zero span circuit pt100 amplifier circuit diagram PT100 Amplifier pt100 circuit diagram Pt100 3 wire EN50081 EN50082 EN60255 EN60688

24v in 5v 10A OUT

Abstract: 230v ac to 12v dc without transformer +15V -5V -15V 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed , -12V +5V +12V -12V -5V 4.75V to 5.50V 14.0V to 16.0V Fixed Fixed 4.75V to 5.50V 23.0V to , to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model Selection Chart 130 165 1 , MAP130 AC/DC Series Data Sheet Features · · · · · · · · Automatic 115/230 input , features include autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning
Power-One
Original
MAP130-1005 MAP130-1012 MAP130-1024 24v in 5v 10A OUT 230v ac to 12v dc without transformer 230 AC to 12V AC transformer 230 AC to 12V dc transformer IN 4001 diode 9V 1A Transformer specification

transformer from 230V AC to 9V ac 500ma

Abstract: 230v AC primary to 9v 500ma secondary transformer , linear transformer needs. With power ratings from 0.08VA to 175VA, fully encapsulated transformers, split , . . . . . . . . . . . 23 EI48 / 16.8 (AC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . , Overview With the addition of era's encapsulated 50/60Hz transformers to the existing line of Pulse open , dissipation achieved through vacuum encapsulation, resulting in more output power from a smaller, more compact , accuracy of each transformer guaranteed by stable and controlled manufacturing processes, allowing for
Pulse Engineering
Original
transformer from 230V AC to 9V ac 500ma 230v AC primary to 9v 500ma secondary transformer 230v ac to primary 15v 500ma secondary transformer transformer 230V 16V 350mA EI30 transformer 9v EI30 transformer LP40-60B29 LP40-150B13 LP40-300B14 LP56-45B30 LP56-100B15
Abstract: LOAD REGULATION 5V 12V/15V 24V/28V 4.75V to 5.50V 11.4V to 15.75V 22.5V to 30.0V 26A 12A , +12V -12V +12V 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed , to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V , stabilization. Time required for output voltage to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model , 8.50" x 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B Power-One
Original
412-59586-G MCD10115

230v ac to 12v dc without transformer circuit

Abstract: 230v ac to 12v dc without transformer circuit dia (NOTE 3) LINE REGULATION LOAD REGULATION 5V 12V/15V 24V/28V 4.75V to 5.50V 11.4V to , 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.5V Fixed , 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V 11.5V , stabilization. Time required for output voltage to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model , " U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering, power fail
Power-One
Original
230v ac to 12v dc without transformer circuit dia n channel 59A 250v Transformer 9v 1A MAP130-4002 transformer 230v to 12v 5A 50 Hz POWER ONE MAP130-4003

transformer from 230V AC to 28v

Abstract: MAP130 5V 12V/15V 24V/28V 4.75V to 5.50V 11.4V to 15.75V 22.5V to 30.0V 26A 12A/10A (Note 2 , 4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to , to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V , to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model Selection Chart 130 165 1 , 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering
Power-One
Original
transformer from 230V AC to 28v MAP130-4000

map130-4010

Abstract: MAP130 5V 12V/15V 24V/28V 4.75V to 5.50V 11.4V to 15.75V 22.5V to 30.0V 26A 12A/10A (Note 2 , +12V -12V +12V 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed , to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V , stabilization. Time required for output voltage to rise from 10% to 90%. 71 80 1.25 0.63 3.00 See Model , 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering
Power-One
Original
map130-4010
Showing first 20 results.